940 resultados para correlation coefficient analysis
Resumo:
Aim: To assess the bone mineral density on conventional and digitized images, comparing whether different parameters of digitization and storage change these values. Methods: Twenty radiographs were taken from five partially dentulous dry mandibles with an aluminum 7-mm stepwedge placed on the superior edge of the film. After processing, the films were digitized with a resolution of 600 and 2,400 d.p.i. and saved as TIFF and JPEG files. On every conventional and digitized image, circular regions of interest were selected for densitometry and radiographic contrast analysis. Results: Pearson's correlation coefficient showed a significant and strong mean gray values association between digitized and conventional images, differing from radiographic contrast that did not show a significant association. ANOVA did not reveal a statistically significant difference in bone density and radiographic contrast among the four digitized image groups, but the conventional image contrast was significantly lower. Conclusions: Bone mineral density did not differ in both conventional and digitized images. The parameters of image compression and resolution, tested in this study, did not change the results of densitometry and digitization process increased the radiographic contrast.
Resumo:
Cognitive changes in normal aging can be similar to the alterations that take place in the initial stages of a dementia process. Longitudinal studies can provide a better understanding of this progression. Objectives: To evaluate the cognitive and functional evolution of community-dwelling individuals without dementia through a three-year longitudinal study. Methods: 168 individuals were evaluated in 2006. Three years later in 2009, 73 of these subjects were reevaluated as regards cognition and functionality using the Mini Mental State Examination (MMSE), Brief Cognitive Battery (BCB) and the Pfeffer Functional Activities Questionnaire. The statistical analysis included descriptive measurements, the Wilcoxon's test for intra-group comparison, and the Spearman's correlation coefficient test for comparing cognitive and functionality scores. Results: After three years, the Wilcoxon's test showed a discreet yet significant cognitive decline (MMSE: -0.7 points; p=0.02; Z= -2.29; and global score on the BCB: +3.6 points; p=0.02; Z= -2.29), in addition to functional decline (Pfeffer: +0.7 points; p= 0.001; Z= -3.38). Conclusions: After three years of follow-up we observed a discreet yet significant functional and cognitive decline in the subjects. Longitudinal cognitive screening represents an important strategy in the early identification of changes from normal conditions to a dementia process.
Resumo:
The aim of this study was to analyze the evolution of natural honey production in Brazil, as well as the Brazilian performance in the international markets and their own consumption behavior of natural honey in the domestic market. For this study, we used descriptive analysis of time series information, data production and export of natural honey understood, respectively, for the periods 1999 to 2010. To analyze the correlation between the series of apparent consumption per capita (variable X) and the international price data (variable Y), we used the statistical analysis of the correlation coefficient of Pearson (CP). Main results revealed that the Brazilian production of natural honey has more than doubled in the last decade, while the Northeast region was the largest contributor to this performance. This increase in the production was mainly directed towards supplying the international market, which currently consumes more than half of Brazilian production. It is true that the change in the international market price has a direct effect on domestic supply, but the Brazilian domestic market has potential for increasing effective consumer who deserves to be better exploited; it implies to pay attention to the supply of quality natural honey, quantity and regularity.
Resumo:
Background: Metabolic and morphological changes associated with excessive abdominal fat, after the introduction of Antiretroviral Therapy, increase the risk of cardiovascular disease in people living with HIV/AIDS(PLWHA). Accurate methods for body composition analysis are expensive and the use of anthropometric indices is an alternative. However the investigations about this subject in PLWHA are rare, making this research very important for clinical purpose and to advance scientific knowledge. The aim of this study is to correlate results of anthropometric indices of evaluation of body fat distribution with the results obtained by Dual-energy X-Ray Absorptiometry(DEXA) , in people living with HIV/AIDS. Methods. The sample was of 67 PLWHA(39 male and 28 female), aged 43.6+7.9 years. Body mass index, conicity index, waist/hip ratio, waist/height ratio and waist/thigh were calculated. Separated by sex, each index/ratio was plotted in a scatter chart with linear regression fit and their respective Pearson correlation coefficients. Analyses were performed using Prism statistical program and significance was set at 5%. Results: The waist/height ratio presented the highest correlation coefficient, for both male (r=0.80, p<0.001) and female (r=0.87, p <001), while the lowest were in the waist/thigh also for both: male group (r=0.58, p<0.001) and female group (r=0.03, p=0.86). The other indices also showed significant positive correlation with DEXA. Conclusion: Anthropometric indices, especially waist/height ratio may be a good alternative way to be used for evaluating the distribution of fat in the abdominal region of adults living with HIV/ADIS. © 2012 Segatto et al.; licensee BioMed Central Ltd.
Resumo:
A voltammetric method for the determination of ethyl acetate in ethanol fuel using a Fe3+/Nafion®-coated glassy carbon electrode (GCE) is proposed. The ethyl acetate present in the ethanol fuel was previously converted to acetohydroxamic acid via pretreatment with hydroxylamine chloride. The acetohydroxamic acid promptly reacted with the iron (III) present in the film, producing iron (III) acetohydroxamate, which presents a well-defined voltammetric peak current at -0.02 V. Optimization of the voltammetric parameters for the cyclic, linear sweep, square wave, and differential pulse modalities was carried out for this chemically-modified electrode. Square wave voltammetry afforded the best response for acetohydroxamic acid detection. The analytical curve for this species was linear from 9 to 100 μmol L 1 according to the following equation: ip (μA) = 0.27 + 2.55Cacetohydroxamic acid (μmol L 1), with linear correlation coefficient equal to 0.993. The technique presented limit of detection equal to 5.3 μmol L 1 and quantification limit of 17.6 μmol L 1. The proposed method was compared to the official method of ethyl acetate analysis (Gas Chromatography), and a satisfactory correlation was found between these techniques. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd.
Resumo:
Food base excess (BE, mEq/kg) can be calculated from the diet macroelements, together with either the sulfur amino acids methionine and cysteine (BEaa) or total sulfur (BEs) concentrations. The present study compared the use of sulfur or methionine and cysteine for calculating the food BE (experiment 1) and investigated the influence of food BE on blood gas analysis and the urine pH of cats, and proposes a prediction equation to estimate the urine pH of cats fed kibble diets based on the calculated food BE (experiments 2 and 3). In experiment 1, nine healthy, adult cats were used in a change-over design and fed with nine commercial dry cat foods. The cats were housed in metabolism cages over seven days for adaptation and three days for total urine collection. All of the urine produced over 24h was pooled by cat and diet. The cats' acid-base status was assessed through blood gas analysis after 10 days of diet consumption. A mean difference of -115mEq/kg between BEs and BEaa was observed, which could be explained by a greater concentration of sulfur in the whole diet than in methionine and cysteine. Urine pH presented a stronger correlation with food BEs (R2=0.95; P<0.001) than with food BEaa (R2=0.86; P<0.001). Experiment 2 included 30 kibble diets, and each diet was tested in six cats. The food BEs varied between -180 and +307mEq/kg, and the urine pH of the cats varied between 5.60 and 7.74. A significant correlation was found between the measured urine pH and the food BEs (urinary pH=6.269+[0.0036×BEs]+[0.000003×BEs2]; R2=0.91; P<0.001). In experiment 3, eight kibble diets were tested (food BEs between -187mEq/kg and +381mEq/kg) to validate the equation proposed in experiment 2 and to compare the obtained results with previously published formulae. The results of the proposed formula presented a high concordance correlation coefficient (0.942) and high accuracy (0.979) with the measured values, and the estimates of urine pH did not differ from the values obtained in cats (P>0.05). The cats' venous blood pH, bicarbonate, and blood BE were correlated with food BEs (P<0.001); the consumption of diets with low food BEs induced a reduction in these parameters. In conclusion, food macroelement composition has a strong influence on cats' acid-base equilibrium and food BEs calculation is a useful tool to formulate and balance kibble diets for felines. © 2013 Elsevier B.V.
Resumo:
Due to an increased awareness and significant environmental pressures from various stakeholders, companies have begun to realize the significance of incorporating green practices into their daily activities. This paper proposes a framework using Fuzzy TOPSIS to select green suppliers for a Brazilian electronics company; our framework is built on the criteria of green supply chain management (GSCM) practices. An empirical analysis is made, and the data are collected from a set of 12 available suppliers. We use a fuzzy TOPSIS approach to rank the suppliers, and the results of the proposed framework are compared with the ranks obtained by both the geometric mean and the graded mean methods of fuzzy TOPSIS methodology. Then a Spearman rank correlation coefficient is used to find the statistical difference between the ranks obtained by the three methods. Finally, a sensitivity analysis has been performed to examine the influence of the preferences given by the decision makers for the chosen GSCM practices on the selection of green suppliers. Results indicate that the four dominant criteria are Commitment of senior management to GSCM; Product designs that reduce, reuse, recycle, or reclaim materials, components, or energy; Compliance with legal environmental requirements and auditing programs; and Product designs that avoid or reduce toxic or hazardous material use. © 2013 Elsevier B.V. All rights reserved.
Resumo:
Background Apathy is a frequent neuropsychiatric condition in neurodegenerative disorders, depression, and often in mild cognitive impairment. The Apathy Inventory (AI) is a reliable instrument for improving the accuracy of the apathy diagnosis. The aim was to establish the validity of the Apathy Inventory for the Brazilian community. Methods We established the concurrent validity, internal consistency, inter-rater reliability, and the sensitivity and specificity of AI for the Brazilian community in a cohort of 175 individuals with Alzheimer's disease, Parkinson's disease, depression, mild cognitive impairment, and healthy controls. The three dimensions of the AI (emotional blunting, lack of initiative, and lack of interest) were compared with the Apathy domain of the Neuropsychiatric Inventory-Clinician rating scale (NPI-C) in an independent scheme. Results The analyses demonstrated high correlation coefficients in AI's individual dimensions and in AI-total score (F = 0.965). Concerning the NPI-C/Apathy domain, intra-class correlation coefficients were also high (F = 0.977). Concurrent validity was high according to both raters on AI dimensions × NPI-C/Apathy domain and regarding total score (rater 1: rho = 0.956 vs. rater 2: rho = 0.970). The internal consistency of the AI was also high concerning the AI's individual dimensions and total score (rater 1: 0.945 vs. rater 2: 0.958). Conclusion We observed high internal consistency, high concurrent validity, and inter-rater reliability of the Apathy Inventory. In addition, we found that its sensitivity and specificity were high. We suggest that the Brazilian version of the Apathy Inventory would be an appropriate instrument to identify the apathy syndrome in Brazilian patients. © 2012 John Wiley & Sons, Ltd.
Resumo:
This work presents the first study and development of an electronic tongue analysis system for the monitoring of nitrogen stable species: nitrate, nitrite and ammonium in water. The electronic tongue was composed of an array of 15 potentiometric poly(vinyl chloride) membrane sensors sensitive to cations and anions plus an artificial neural network (ANN) response model. The building of the ANN model was performed in a medium containing sodium, potassium, and chloride as interfering ions, thus simulating real environmental samples. The correlation coefficient in the cross-validation of nitrate, nitrite and ammonium was satisfactory in the three cases with values higher than 0.92. Finally, the utility of the proposed system is shown in the monitoring of the photoelectrocatalytic treatment of nitrate. © 2013 Elsevier B.V.
Resumo:
The Poincaré plot for heart rate variability analysis is a technique considered geometrical and non-linear, that can be used to assess the dynamics of heart rate variability by a representation of the values of each pair of R-R intervals into a simplified phase space that describes the system's evolution. The aim of the present study was to verify if there is some correlation between SD1, SD2 and SD1/SD2 ratio and heart rate variability nonlinear indexes either in disease or healthy conditions. 114 patients with arterial coronary disease and 65 healthy subjects underwent 30. minute heart rate registration, in supine position and the analyzed indexes were as follows: SD1, SD2, SD1/SD2, Sample Entropy, Lyapunov Exponent, Hurst Exponent, Correlation Dimension, Detrended Fluctuation Analysis, SDNN, RMSSD, LF, HF and LF/HF ratio. Correlation coefficients between SD1, SD2 and SD1/SD2 indexes and the other variables were tested by the Spearman rank correlation test and a regression analysis. We verified high correlation between SD1/SD2 index and HE and DFA (α1) in both groups, suggesting that this ratio can be used as a surrogate variable. © 2013 Elsevier B.V.
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Validação do glicosímetro portátil para avaliação, prescrição e monitoramento do treinamento aeróbio
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)