967 resultados para bioanalytical method validation
Resumo:
Reporter genes are routinely used in every laboratory for molecular and cellular biology for studying heterologous gene expression and general cellular biological mechanisms, such as transfection processes. Although well characterized and broadly implemented, reporter genes present serious limitations, either by involving time-consuming procedures or by presenting possible side effects on the expression of the heterologous gene or even in the general cellular metabolism. Fourier transform mid-infrared (FT-MIR) spectroscopy was evaluated to simultaneously analyze in a rapid (minutes) and high-throughput mode (using 96-wells microplates), the transfection efficiency, and the effect of the transfection process on the host cell biochemical composition and metabolism. Semi-adherent HEK and adherent AGS cell lines, transfected with the plasmid pVAX-GFP using Lipofectamine, were used as model systems. Good partial least squares (PLS) models were built to estimate the transfection efficiency, either considering each cell line independently (R 2 ≥ 0.92; RMSECV ≤ 2 %) or simultaneously considering both cell lines (R 2 = 0.90; RMSECV = 2 %). Additionally, the effect of the transfection process on the HEK cell biochemical and metabolic features could be evaluated directly from the FT-IR spectra. Due to the high sensitivity of the technique, it was also possible to discriminate the effect of the transfection process from the transfection reagent on KEK cells, e.g., by the analysis of spectral biomarkers and biochemical and metabolic features. The present results are far beyond what any reporter gene assay or other specific probe can offer for these purposes.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores – Sistemas Digitais e Percepcionais pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica
Resumo:
The moisture content in concrete structures has an important influence in their behavior and performance. Several vali-dated numerical approaches adopt the governing equation for relative humidity fields proposed in Model Code 1990/2010. Nevertheless there is no integrative study which addresses the choice of parameters for the simulation of the humidity diffusion phenomenon, particularly in concern to the range of parameters forwarded by Model Code 1990/2010. A software based on a Finite Difference Method Algorithm (1D and axisymmetric cases) is used to perform sensitivity analyses on the main parameters in a normal strength concrete. Then, based on the conclusions of the sensi-tivity analyses, experimental results from nine different concrete compositions are analyzed. The software is used to identify the main material parameters that better fit the experimental data. In general, the model was able to satisfactory fit the experimental results and new correlations were proposed, particularly focusing on the boundary transfer coeffi-cient.
Resumo:
The present paper focuses on a damage identification method based on the use of the second order spectral properties of the nodal response processes. The explicit dependence on the frequency content of the outputs power spectral densities makes them suitable for damage detection and localization. The well-known case study of the Z24 Bridge in Switzerland is chosen to apply and further investigate this technique with the aim of validating its reliability. Numerical simulations of the dynamic response of the structure subjected to different types of excitation are carried out to assess the variability of the spectrum-driven method with respect to both type and position of the excitation sources. The simulated data obtained from random vibrations, impulse, ramp and shaking forces, allowed to build the power spectrum matrix from which the main eigenparameters of reference and damage scenarios are extracted. Afterwards, complex eigenvectors and real eigenvalues are properly weighed and combined and a damage index based on the difference between spectral modes is computed to pinpoint the damage. Finally, a group of vibration-based damage identification methods are selected from the literature to compare the results obtained and to evaluate the performance of the spectral index.
Resumo:
We elaborated an alternative culture method, which we denominated PKO (initials in tribute of respect to Petroff, Kudoh and Ogawa), for isolating Mycobacterium tuberculosis from sputum for diagnosis of pulmonary tuberculosis (TB), and to compare its performance with the Swab and Petroff methods. For the technique validation, sputum samples from patients suspected of pulmonary TB cases were examined by acid-fast microscopy (direct and concentrated smear), PKO, Swab and Petroff methods. We found that Petroff and PKO methods have parity in the effectiveness of M. tuberculosis isolation. However, by the PKO method, 65% of isolated strains were detected in a period of £15 days, while by the Petroff method the best detection was in an interval of 16-29 days (71%). In positive smear samples, the average time of PKO isolation is only superior to the one related for Bactec 460TB. In conclusion, the exclusion of the neutralization stage of pH in the PKO reduces the manipulation of the samples, diminishes the execution time of the culture according to the Petroff method and facilitates the qualification of professionals involved in the laboratorial diagnosis of Tuberculosis.
Resumo:
OBJECTIVE: This work was designed to validate the Portuguese version of the Contemplation Ladder, whose purpose is to assess the motivational phase to quit smoking among tobacco users using a telephone service. METHOD: A cross-sectional study was conducted in a nationwide drug use information hotline. In order to assess the convergent validation, the correlation between the Contemplation Ladder and the URICA Scale was calculated, which was previously validated. RESULTS: The study included 271 tobacco users. Statistically significant correlations were found between the Contemplation Ladder scores and the scores of the URICA precontemplation (r=-0.16; p<0.01), action (r=0.15; p<0.01) and maintenance (r=0.18; p<0.01) subscales. The correlation between the URICA Scale compound score and the Contemplation Ladder was also significant (r=0.31; p<0.01). CONCLUSION: The results of our study suggest that the Contemplation Ladder can be an efficient substitute for the URICA scale (whose application lasts at least 20 minutes), without submitting the interviewee to a heavy load of questions. The study presented evidences of convergent validity for the Contemplation Ladder when applied via telephone in tobacco users.
Resumo:
OBJECTIVES: To describe the process of translation and linguistic and cultural validation of the Evidence Based Practice Questionnaire for the Portuguese context: Questionário de Eficácia Clínica e Prática Baseada em Evidências (QECPBE). METHOD: A methodological and cross-sectional study was developed. The translation and back translation was performed according to traditional standards. Principal Components Analysis with orthogonal rotation according to the Varimax method was used to verify the QECPBE's psychometric characteristics, followed by confirmatory factor analysis. Internal consistency was determined by Cronbach's alpha. Data were collected between December 2013 and February 2014. RESULTS: 358 nurses delivering care in a hospital facility in North of Portugal participated in the study. QECPBE contains 20 items and three subscales: Practice (α=0.74); Attitudes (α=0.75); Knowledge/Skills and Competencies (α=0.95), presenting an overall internal consistency of α=0.74. The tested model explained 55.86% of the variance and presented good fit: χ2(167)=520.009; p = 0.0001; χ2df=3.114; CFI=0.908; GFI=0.865; PCFI=0.798; PGFI=0.678; RMSEA=0.077 (CI90%=0.07-0.08). CONCLUSION: confirmatory factor analysis revealed the questionnaire is valid and appropriate to be used in the studied context.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
BACKGROUND: Adequate pain assessment is critical for evaluating the efficacy of analgesic treatment in clinical practice and during the development of new therapies. Yet the currently used scores of global pain intensity fail to reflect the diversity of pain manifestations and the complexity of underlying biological mechanisms. We have developed a tool for a standardized assessment of pain-related symptoms and signs that differentiates pain phenotypes independent of etiology. METHODS AND FINDINGS: Using a structured interview (16 questions) and a standardized bedside examination (23 tests), we prospectively assessed symptoms and signs in 130 patients with peripheral neuropathic pain caused by diabetic polyneuropathy, postherpetic neuralgia, or radicular low back pain (LBP), and in 57 patients with non-neuropathic (axial) LBP. A hierarchical cluster analysis revealed distinct association patterns of symptoms and signs (pain subtypes) that characterized six subgroups of patients with neuropathic pain and two subgroups of patients with non-neuropathic pain. Using a classification tree analysis, we identified the most discriminatory assessment items for the identification of pain subtypes. We combined these six interview questions and ten physical tests in a pain assessment tool that we named Standardized Evaluation of Pain (StEP). We validated StEP for the distinction between radicular and axial LBP in an independent group of 137 patients. StEP identified patients with radicular pain with high sensitivity (92%; 95% confidence interval [CI] 83%-97%) and specificity (97%; 95% CI 89%-100%). The diagnostic accuracy of StEP exceeded that of a dedicated screening tool for neuropathic pain and spinal magnetic resonance imaging. In addition, we were able to reproduce subtypes of radicular and axial LBP, underscoring the utility of StEP for discerning distinct constellations of symptoms and signs. CONCLUSIONS: We present a novel method of identifying pain subtypes that we believe reflect underlying pain mechanisms. We demonstrate that this new approach to pain assessment helps separate radicular from axial back pain. Beyond diagnostic utility, a standardized differentiation of pain subtypes that is independent of disease etiology may offer a unique opportunity to improve targeted analgesic treatment.
Resumo:
To further validate the doubly labeled water method for measurement of CO2 production and energy expenditure in humans, we compared it with near-continuous respiratory gas exchange in nine healthy young adult males. Subjects were housed in a respiratory chamber for 4 days. Each received 2H2(18)O at either a low (n = 6) or a moderate (n = 3) isotope dose. Low and moderate doses produced initial 2H enrichments of 5 and 10 X 10(-3) atom percent excess, respectively, and initial 18O enrichments of 2 and 2.5 X 10(-2) atom percent excess, respectively. Total body water was calculated from isotope dilution in saliva collected at 4 and 5 h after the dose. CO2 production was calculated by the two-point method using the isotopic enrichments of urines collected just before each subject entered and left the chamber. Isotope enrichments relative to predose samples were measured by isotope ratio mass spectrometry. At low isotope dose, doubly labeled water overestimated average daily energy expenditure by 8 +/- 9% (SD) (range -7 to 22%). At moderate dose the difference was reduced to +4 +/- 5% (range 0-9%). The isotope elimination curves for 2H and 18O from serial urines collected from one of the subjects showed expected diurnal variations but were otherwise quite smooth. The overestimate may be due to approximations in the corrections for isotope fractionation and isotope dilution. An alternative approach to the corrections is presented that reduces the overestimate to 1%.
Resumo:
L'objectif de l'étude présentée est d'adapter et de valider une version française de la Stigma Scale (King, 2007) auprès d'une population de personnes souffrant de troubles psychiques. Dans une première phase, la stabilité temporelle (fidélité test-retest), la cohérence interne et la validité convergente de l'instrument original à 28 items traduit en français ont été évaluées auprès d'un échantillon de 183 patients. Les résultats d'analyses factorielles confirmatoires ne nous ont pas permis de confirmer la structure originale de l'instrument. Nous avons donc proposé, sur la base des résultats d'une analyse factorielle exploratoire, une version courte de l'échelle de stigmatisation (9 items) qui conserve la structure en trois facteurs du modèle original. Dans une deuxième phase, nous avons examiné les qualités psychométriques et validé cette version abrégée de l'échelle de stigmatisation auprès d'un second échantillon de 234 patients. Les indices d'ajustements de notre analyse factorielle confirmatoire confirme la structure en trois facteurs de la version abrégée de la Stigma Scale. Les résultats suggèrent que la version française abrégée de l'échelle de stigmatisation constitue un instrument utile, fiable et valide dans l'autoévaluation de la stigmatisation perçue par des personnes souffrant de troubles psychiques. - Aim People suffering from mental illness are exposed to stigma. However, only few tools are available to assess stigmatization as perceived from the patient's perspective. The aim of this study is to adapt and validate a French version of the Stigma Scale (King, 2007). This self-report questionnaire has a three-factor structure: discrimination, disclosure and positive aspects of mental illness. Discrimination subscale refers to perceived negative reactions by others. Disclosure subscale refers mainly to managing disclosure to avoid discrimination and finally positive aspects subscale taps into how patients are becoming more accepting, more understanding toward their illness. Method In the first step, internal consistency, convergent validity and test-retest reliability of the French adaptation of the 28-item scale have been assessed on a sample of 183 patients. Results of confirmatory factor analyses (CFA) did not confirm the hypothesized structure. In light of the failed attempts to validate the original version, an alternative 9-item short-form version of the Stigma Scale, maintaining the integrity of the original model, was developed based on results of exploratory factor analyses in the first sample and cross- validated in a new sample of 234 patients. Results Results of CFA did not confirm that the data fitted well to the three-factor model of the 28-item Stigma Scale (χ2/άί=2.02, GFI=0.77, AGFI=0.73, RMSEA=0.07, CFI=0.77 et NNFI=0.75). Cronbach's α are excellent for discrimination (0.84) and disclosure (0.83) subscales but poor for potential positive aspects (0.46). External validity is satisfactory. Overall Stigma Scale total score is negatively correlated with score on Rosenberg's Self-Esteem Scale (r = -0.49), and each sub-scale is significantly correlated with a visual analogue scale that refers to the specific aspect of stigma (0.43 < |r| < 0.60). Intraclass correlation coefficients between 0.68 and 0.89 indicate good test- retest reliability. Results of CFA demonstrate that the items chosen for the short version of the Stigma Scale have the expected fit properties fa2/df=1.02, GFI=0.98, AGFI=0.98, RMSEA=0.01, CFI=1.0 et NNFI=1.0). Considering the small number (3 items) of items in each subscales of the short version of the Stigma Scale, a coefficients for the discrimination (0.57), disclosure (0.80) and potential positive aspects subscales (0.62) are considered as good. Conclusion Our results suggest that the 9-item French short-version of the Stigma Scale is a useful, reliable and valid self-report questionnaire to assess perceived stigmatization in people suffering from mental illness. The time of completion is really short and questions are well understood and accepted by the patients.
Resumo:
BACKGROUND: Hepcidin, a 25 amino acid peptide, plays an important role in iron homeostasis. Some hepcidin truncated peptides have antibiotic effects. RESULTS: A new analytical method for hepcidin determination in human plasma using LC-HRMS operating in full-scan acquisition mode has been validated. The extraction consists of protein precipitation and a drying reconstitution step; a 2.1 x 50 mm (idxL) C18 analytical column was used. Detection specificity, stability, accuracy, precision and recoveries were determined. The LOQ/LOD were 0.25/0.1 nM, respectively. More than 600 injections of plasma extracts were performed, allowing evaluation of the assay robustness. Hepcidin-20, hepcidin-22 and a new isoform, hepcidin-24, were detected in patients. CONCLUSION: The data underscore the usefulness of LC-HRMS for in-depth investigations related to hepcidin levels and pathways.
Resumo:
BACKGROUND: Major depression, although frequent in primary care, is commonly hidden behind multiple physical complaints that are often the first and only reason for patient consultation. Major depression can be screened by two validated questions that are easier to use in primary care than the full DSM-IV criteria. A third question, called the "help" question, improves the specificity without apparently decreasing the sensitivity of this screening procedure. We validated the abbreviated screening procedure for major depression with and without the "help" question in primary care patients managed for a physical complaint. METHODS: This diagnostic accuracy study used data from a cohort study called SODA (for SOmatisation Depression Anxiety ) conducted by 24 general practitioners (GPs) in western Switzerland that included patients over 18 years of age with at least one physical complaint at index consultation. Major depression was identified with the full Patient Health Questionnaire. GPs were asked to screen patients for major depression with the three screening questions one year after inclusion. RESULTS: Out of 937 patients with at least one physical complaint, 751 were eligible one year after index consultation. Major depression was diagnosed in 69/724 (9.5%) patients. The sensitivity and specificity of the two-question method alone were 91.3% (95% confidence interval 81.4-96.4%) and 65.0% (95% confidence interval 61.2-68.6%), respectively. Adding the "help" question decreased the sensitivity (59.4% ; 95% confidence interval 47.0-70.9%) but improved the specificity (88.2% ; 95% confidence interval 85.4-90.5%) of the three-question method. CONCLUSIONS: The use of two screening questions for major depression was associated with high sensitivity and low specificity in primary care patients presenting a physical complaint. Adding the "help" question improved the specificity but clearly decreased the sensitivity; when using the "help" question; four out of ten patients with depression will be missed, compared to only one out of ten with the two-question method. Therefore, the "help" question is not useful as a screening question, but may help discussing management strategies.