980 resultados para bead-based assay


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A colorimetric method has been developed and optimized to measure L-malic acid in samples of fruit juices and wine. This method is based on oxidation of the analyte, catalyzed by malate dehydrogenase (MDH) from dry baker's yeast, and in combination with the reduction of a tetrazolium salt (MTT: 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide). In the present study, the method exhibited sensitivity in the range of 500-4000 mu M of L-malic acid in the reaction cuvette, with the lower detection limit of 6.7-10(-2) g/L, the upper limit of 53.6.10(-2) g/L and a maximum standard deviation of only 2.5 % for the analyzed samples. The MDH activity from baker's yeast was also optimized, the enzyme showed a high stability at pH=8.0-9.0 and the activity was maintained completely at temperatures up to 40 degrees C for 1 hour. The results show that the colorimetric method using enzymatic preparations from dry baker's yeast is a simple and low-cost method with possibility of wide application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel material for electrochemical biosensing based on rigid conducting gold nanocomposite (nano-AuGEC) is presented. Islands of chemisorbing material (gold nanoparticles) surrounded by nonreactive, rigid, and conducting graphite epoxy composite are thus achieved to avoid the stringent control of surface coverage parameters required during immobilization of thiolated oligos in continuous gold surfaces. The spatial resolution of the immobilized thiolated DNA was easily controlled by merely varying the percentage of gold nanoparticles in the composition of the composite. As low as 9 fmol (60 pM) of synthetic DNA were detected in hybridization experiments when using a thiolated probe. Moreover, for the first time a double tagging PCR strategy was performed with a thiolated primer for the detection of Salmonella sp., one of the most important foodborne pathogens affecting food safety. Ibis assay was performed by double-labeling the amplicon during the PCR with a -DIG and -SH set of labeled primers. The thiolated end allows the immobilization of the amplicon on the nano-AuGEC electrode, while digoxigenin allows the electrochemical detection with the antiDIG-HRP reporter in the femtomole range. Rigid conducting gold nanocomposite represents a good material for the improved and oriented immobilization of biomolecules with excellent transducing properties for the construction of a wide range of electrochemical biosensors such as immunosensors, genosensors, and enzymosensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective-To develop and apply the liquid-phase blocking sandwich ELISA (BLOCKING-ELISA) for the quantification of antibodies against foot-and-mouth disease virus (FMDV) strains O-1 Campos, A(24) Cruzeiro, and C-3 Indaial.Design-Antibody quantification.Sample Population-158 water buffalo from various premises of São Paulo Stale-Brazil. The sera were collected either from systemically vaccinated or nonvaccinated animals.Procedure-The basic reagents of BLOCKING-ELISA (capture and detector antibodies, virus antigens, and conjugate) were prepared and the reaction was optimized and standardized to quantify water buffalo antibodies against FMDV. An alternative procedure based on mathematical interpolation was adopted to estimate more precisely the antibody 50% competition liters in the BLOCKING-ELISA. These titers were compared with the virus-neutralization test (VNT) titers to determine the correlation between these techniques. The percentages of agreement, cutoff points, and reproducibility also were determined.Results-The antibody liters obtained in the BLOCKING-ELISA had high positive correlation coefficients with VNT, reaching values of 0.90 for O-1 Campos and C-3 Indaial, and 0.82 for the A(24) Cruzeiro (P < 0.0005). The cutoff points obtained by use of the copositivity and conegativity curves allowed determination of high levels of agreement between BLOCKLNG-ELISA and VNT antibody titers against the 3 FMDV strains analyzed.Conclusions-The results characterized by high cor relation coefficients, levels of agreement, and reproducibility indicate that the BLOCKING-ELISA may replace the conventional VNT for detection and quantification of antibodies from water buffalo sera to FMDV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two experiments were carried out to evaluate a larval development assay for the detection of anthelmintic resistance in O. circumcincta. In Experiment I, the dose responses to levamisole (LEV), thiabendazole (TBZ) and ivermectin (IVM) of 8 isolates of O. circumcincta were measured 34 days after infection (DAI). Four of these isolates were shown to be resistant to 1 or more anthelmintics. With 2 exceptions, all isolates considered to be resistant had higher LD50 values than the susceptible isolates for that anthelmintic. One exception was isolate RM8, which was considered to be resistant to all 3 anthelmintics based on faecal egg count reduction tests in goats, but the LD50 value for LEV did not differ from that for the susceptible isolates. The other exception was an isolate considered to be susceptible to TBZ which had a relatively high LD50 value. In an unrelated trial that was prompted by this finding, this isolate was confirmed to be benzimidazole-resistant. Isolate RM8 and an isolate susceptible to all 3 anthelmintics (SK2) were used in the second experiment, which was conducted to monitor changes in the LD50 values of LEV, TBZ and IVM over time following a single infection of 35 000 infective larvae in young sheep. Faecal samples were collected weekly from 24 to 115 DAI. With all 3 anthelmintics, the LD50 values increased with time to a peak around 50-60 DAI, and then declined to levels similar to those observed soon after patency. This trend was consistent for both isolates. The highest mean LD50 values for isolates SK2 for IVM and TBZ and RM8 for IVM and RM8, respectively, were 1.7 and 1.8 times, and 2.2 and 2.9 times higher than the initial mean LD50 values. There was a clear distinction in LD50 values between isolates at each sampling day for both IVM and TBZ. However, as a consequence of the changes in LD50 values with time, the peak LD50 values of IVM for isolate SK2 were higher than the minimum LD50 values of isolate RM8. As there was no apparent difference in LEV efficacy between these 2 isolates, the data were pooled. The highest mean LD50 value was 2.3 times higher than the initial LD50 value. (C) 1997 Australian Society for Parasitology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow-cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III). The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2-210 μmol l-1 H2O2 with a LD of 1.8 μmol l-1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10-5 mol l-1 and 6.8×10-5 mol l-1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 μg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved. Copyright © Taylor & Francis Group, LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ceftriaxone sodium is a cephalosporin with broad-spectrum antimicrobial activity and belongs to the third generation of cephalosporins. Regarding the quality control of medicines, a validated microbiological assay for the determination of ceftriaxone sodium in powder for injectable solution has not been reported yet. This paper reports the development and validation of a simple, accurate and reproducible agar diffusion method to quantify ceftriaxone sodium in powder for injectable solution. The assay is based on the inhibitory effect of ceftriaxone sodium on the strain of Bacillus subtilis ATCC 9371 IAL 1027 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.999) in the selected range of 15.0-60.0 μg/mL, precise with a relative standard deviation (RSD) of repeatability intraday = 1.40%, accurate (100.46%) and robust with a RSD lower than 1.28%. The results demonstrated the validity of the proposed bioassay, which allows reliable ceftriaxone sodium quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2012 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)