990 resultados para barium enema


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Total rectocolectomy and ileal pouch-anal anastomosis is the choice surgical procedure for patients with ulcerative colitis. In cases of Crohn's disease post-operative diagnosis, it can be followed by pouch failure. AIM: To evaluate ileal pouch-anal anastomosis long-term outcome in patients with Crohn's disease. METHODS: Between February 1983 and March 2007, 151 patients were submitted to ileal pouch-anal anastomosis by Campinas State University Colorectal Unit, Campinas, SP, Brazil, 76 had pre-operative ulcerative colitis diagnosis and 11 had post-operative Crohn's disease diagnosis. Crohn's disease diagnosis was made by histopathological biopsies in nine cases, being one in surgical specimen, two cases in rectal stump, small bowel in two cases, ileal pouch in three and in perianal abscess in one of them. The median age was 30.6 years and eight (72.7%) were female. RESULTS: All patients had previous ulcerative colitis diagnosis and in five cases emergency colectomy was done by toxic megacolon. The mean time until of Crohn's disease diagnosis was 30.6 (6-80) months after ileal pouch-anal anastomosis. Ileostomy closure was possible in 10 cases except in one that had ileal pouch fistula, perianal disease and small bowel involvement. In the long-term follow-up, three patients had perineal fistulas and one had also a pouch-vaginal fistula. All of them were submitted to a new ileostomy and one had the pouch excised. Another patient presented pouch-vaginal fistula which was successfully treated by mucosal flap. Three patients had small bowel involvement and three others, pouch involvement. All improved with medical treatment. Presently, the mean follow-up is 76.5 months and all patients are in clinical remission, and four have fecal diversion. The remaining patients have good functional results with 6-10 bowel movements/day. CONCLUSION: Crohn's disease diagnosis after ileal pouch-anal anastomosis for ulcerative colitis may be usual and later complications such fistulas and stenosis are common. However, when left in situ ileal pouch is associated with good function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By mid 2003, the Brazilian people accompanied astonished, in the press, the news about the death of more than 20 persons due to ingestion of a pharmaceutical product containing a suspension of barium sulfate (Celobar®) commonly used as a radiological contrast. Analysis of the product indicated the presence of barium carbonate (about 13% weight/weight) which reacts easily with the hydrochloric acid in the stomach liberating barium ions, a severe poison. In this article, we briefly discuss the possible economic, personal and technical causes that led to this disaster.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context. NGC 6522 has been the first metal-poor globular cluster identified in the bulge by Baade. Despite its importance, very few high-resolution abundance analyses of stars in this cluster are available. The bulge metal-poor clusters may be important tracers of the early chemical enrichment of the Galaxy. Aims. The main purpose of this study is to determine metallicity and elemental ratios in individual stars of NGC 6522. Methods. High-resolution spectra of 8 giants of the bulge's globular cluster NGC 6522 were obtained at the 8m VLT UT2-Kueyen telescope with the FLAMES+GIRAFFE spectrograph. Multiband V, I, J, K(s) photometry was used to derive effective temperatures as reference values. Spectroscopic parameters were derived from Fe I and Fe II lines, and adopted for the derivation of abundance ratios. Results. The present analysis provides a metallicity [Fe/H] = -1.0 +/- 0.2. The alpha-elements oxygen, magnesium and silicon show [O/Fe] = +0.4 +/- 0.3, [Mg/Fe] = [Si/Fe] = +0.25 +/- 0.15, whereas calcium and titanium show shallower ratios of [Ca/Fe] = [Ti/Fe] = +0.15 +/- 0.15. The neutron-capture r-process element europium appears to be overabundant by [Eu/Fe] = +0.4 +/- 0.4. The neutron-capture s-elements lanthanum and barium are enhanced by [La/Fe] = +0.35 +/- 0.2 and [Ba/Fe] = +0.5 +/- 0.5. The large internal errors, indicating the large star-to-star variation in the barium and europium abundances, are also discussed. Conclusions. The moderate metallicity combined to a blue horizontal branch (BHB), are characteristics similar to those of HP 1 and NGC 6558, pointing to a population of very old globular clusters in the Galactic bulge. Also, the abundance ratios in NGC 6522 resemble those in HP 1 and NGC 6558. The ultimate conclusion is that the bulge is old, and went through an early prompt chemical enrichment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structural, dielectric, and vibrational properties of pure and rare earth (RE)-doped Ba(0.77) Ca(0.23)TiO(3) (BCT23; RE = Nd, Sm, Pr, Yb) ceramics obtained via solid-state reaction were investigated. The pure and RE-doped BCT23 ceramics sintered at 1450 degrees C in air for 4 h showed a dense microstructure in all ceramics. The use of RE ions as dopants introduced lattice-parameter changes that manifested in the reduction of the volume of the unit cell. RE-doped BCT23 samples exhibit a more homogenous microstructure due to the absence of a Ti-rich phase in the grain boundaries as demonstrated by scanning electron microscopy imaging. The incorporation of REs led to perturbations of the local symmetry of TiO(6) octahedra and the creation of a new Raman mode. The results of Raman scattering measurements indicated that the Curie temperature of the ferroelectric phase transition depends on the RE ion and ion content, with the Curie temperature shifting toward lower values as the RE content increases, with the exception of Yb(3+) doping, which did not affect the ferroelectric phase transition temperature. The phase transition behavior is explained using the standard soft mode model. Electronic paramagnetic resonance measurements showed the existence of Ti vacancies in the structure of RE-doped BCT23. Defects are created via charge compensation mechanisms due to the incorporation of elements with a different valence state relative to the ions of the pure BCT23 host. It is concluded that the Ti vacancies are responsible for the activation of the Raman mode at 840 cm(-1), which is in agreement with lattice dynamics calculations. (c) 2011 American Institute of Physics. [doi:10.1063/1.3594710]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ti K-edge x-ray absorption near-edge spectroscopy (XANES) and Raman scattering were used to study the solid solution effects on the structural and vibrational properties of Pb(1-x)Ba(x)Zr(0.65)Ti(0.35)O(3) with 0.0 < x < 0.40. Compared with x-ray diffraction techniques, which indicates that the average crystal symmetry changes with the substitution of Pb by Ba ions or with temperature variations for samples with x=0.00, 0.10, and 0.20, local structural probes such as XANES and Raman scattering results demonstrate that at local level, the symmetry changes are much less prominent. Theoretical XANES spectra calculation corroborate with the interpretation of the XANES experimental data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Time-resolved Z-scan measurements were performed in a Nd(3+)-doped Sr(0.61)Ba(0.39)Nb(2)O(6) laser crystal through ferroelectric phase transition. Both the differences in electronic polarizability (Delta alpha(p)) and cross section (Delta sigma) of the neodymium ions have been found to be strongly modified in the surroundings of the transition temperature. This observed unusual behavior is concluded to be caused by the remarkable influence that the structural changes associated to the ferro-to-paraelectric phase transition has on the 4f -> 5d transition probabilities. The maximum polarizability change value Delta alpha(p)=1.2x10(-25) cm(3) obtained at room temperature is the largest ever measured for a Nd(3+)-doped transparent material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dielectric and Raman scattering experiments were performed on polycrystalline Pb(1-x)Ba(x)TiO(3) thin films (x=0.40 and 0.60) as a function of temperature. The dielectric study on single phase compositions revealed that a diffuse-type phase transition occurred upon transformation of the cubic paraelectric to the tetragonal ferroelectric phase in all thin films, which showed a broadening of the dielectric peak. Diffusivity was found to increase with increasing barium contents in the composition range under study. In addition, the temperature dependence of Raman scattering spectra was investigated through the ferroelectric phase transition. The temperature dependence of the phonon frequencies was used to characterize the phase transitions. Raman modes persisted above the tetragonal to cubic phase transition temperature, although all optical modes should be Raman inactive. The origin of these modes was interpreted as a breakdown of the local cubic symmetry by chemical disorder. The lack of a well-defined transition temperature and the presence of broadbands in some temperature intervals above the paraferroelectric phase transition temperature suggest a diffuse-type phase transition. (C) 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection (FI) micelle-mediated separation/preconcentration procedure for the determination of lead and cadmium by flame atomic absorption spectrometry (FAAS) has been proposed. The analytes reacted with 1-(2-thiazolylazo)-2-naphthol (TAN) to form hydrophobic chelates, which were extracted into the micelles of 0.05% (w/v) Triton X-114 in a solution buffered at pH 8.4. In the preconcentration stage, the micellar solution was continuously injected into a flow system with four mini-columns packed with cotton, glass wool. or TNT compresses for phase separation. The analytes-containing micelles were eluted from the mini-columns by a stream of 3 mol L(-1) HCl solution and the analytes were determined by FAAS. Chemical and flow variables affecting the preconcentration of the analytes were studied. For 15 mL. of preconcentrated solution, the enhancement factors varied between 15.1 and 20.3, the limits of detection were approximately 4.5 and 0.75 mu g L(-1) for lead and cadmium, respectively. For a solution containing 100 and 10 mu g L(-1) of lead and cadmium, respectively, the R.S.D. values varied from 1.6 to 3.2% (n = 7). The accuracy of the preconcentration system was evaluated by recovery measurements on spiked water samples. The method was susceptible to matrix effects, but these interferences were minimized by adding barium ions as masking agent in the sample solutions, and recoveries from spiked sample varied in the range of 95.1-107.3%. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selenium (Se) intake is generally from food, whose Se content depends on soil Se and plant accumulation. For humans, adequate Se intake is essential for several selenoenzymes. In the Lower Tapajos region of the Brazilian Amazon, Se status is elevated with large inter-community variability. Se intake in this region, where Hg exposure is among the highest in the world, may be important to counteract mercury (Hg) toxicity. The present study was conducted in 2006 with 155 persons from four communities of the Lower Tapajos. The objectives were: i) to evaluate Se content in their typical diet and drinking water; ii) to compare food Se concentrations with respect to geographic location; and iii) to examine the contribution of consumption of different food items to blood Se. More than 400 local foods and 40 drinking water samples were collected. Participants responded to an interview-administered food frequency questionnaire and provided blood samples. Food, water and blood Se levels were assessed by ICP-MS. Since Brazil nuts may also contain significant levels of barium (Ba) and strontium (Sr), these elements were likewise analyzed in nuts. The highest Se concentrations were found in Brazil nuts, but concentrations were highly variable (median: 13.9 mu g/g; range: 0.4-158.4 mu g/g). Chicken, game meat, eggs and beef also contained considerable levels of Se, with median concentrations from 0.3 to 1.4 mu g/g. There was no particular geographic distribution of food Se. Se concentration in drinking water was very low (<1.4 mu g/L). Blood Se covered a (103-1500 mu g/L), and was positively related to regular consumption of Brazil nuts, domestic chicken and game meat. Brazil nuts were found to contain highly variable and often very high concentrations of Ba (88.0 mu g/g, 1.9-1437 mu g/g) and Sr (38.7 mu g/g, 3.3-173 mu g/g). Further studies should address multiple nutrient/toxic interactions in the diet and related effects on health. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vomiting after feeding is a symptom of gastroesophageal reflux (GER) and of eosinophilic esophagitis (EE), which are considered to be a cause of infant feeding disorder. The objective of the present study was to evaluate swallowing in children with feeding disorder manifested by vomiting after feeding. Using clinical and videofluoroscopic methods we studied the swallowing of 37 children with vomiting after feeding (mean age = 15.4 months), and of 15 healthy children (mean age = 20.5 months). In the videofluoroscopic examination the children swallowed a free volume of milk and 5 ml of mashed banana, both mixed with barium sulfate. We evaluated five swallows of liquid and five swallows of paste. The videofluoroscopic examination was recorded at 60 frames/s. Patients had difficulty during feeding, pneumonia, respiratory distress, otitis, and irritability more frequently than controls. During feeding, children with vomiting, choke were irritable, and refused food more frequently than controls, and during the videofluoroscopic examination the patients had more backward movement of the head than controls for both the liquid and paste boluses. There was no difference in the timing of oral swallowing transit, pharyngeal swallowing transit, or pharyngeal clearance between patients and controls. We conclude that children with vomiting after feeding may have difficulties in accepting feeding, although they have no alteration of oral and pharyngeal phases of swallowing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are data suggesting that women swallow liquids at a lower flow rate and ingest smaller volumes in each swallow than men. Our objective in this work was to compare swallowing in asymptomatic men and women by videofluoroscopy. We studied 18 men [age = 33-77 years, mean = 61 (10) years] and 12 women [age = 29-72 years, mean = 53 (15) years] who swallowed in duplicate 5 and 10 ml of liquid and paste barium boluses. None of the volunteers had dysphagia, neurologic diseases, or oral, pharyngeal, or esophageal diseases. The videofluoroscopic examination showed that for the 5-ml bolus, women had a longer oropharyngeal transit [liquid: men, 0.63 (0.21) s, women, 0.88 (0.39) s; paste: men, 0.64 (0.35) s, women, 0.94 (0.58) s], longer oral transit [liquid: men, 0.41 (0.21) s, women, 0.59 (0.35) s; paste: men, 0.39 (0.28) s, women, 0.59 (0.42) s], and longer pharyngeal clearance [liquid: men, 0.36 (0.11) s, women, 0.45 (0.16) s; paste: men, 0.42 (0.25) s, women, 0.56 (0.27) s] compared with men (p < 0.05). We conclude that there are differences in swallowing between men and women, with women having a longer oropharyngeal transit than men for a 5-ml bolus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. The role of inorganic content on physical properties of resin composites is well known. However, its influence on polymerization stress development has not been established. The aim of this investigation was to evaluate the influence of inorganic fraction on polymerization stress and its determinants, namely, volumetric shrinkage, elastic modulus and degree of conversion. Methods. Eight experimental composites containing 1:1 BisGMA (bisphenylglycidyl dimethacrylate): TEGDMA (triethylene glycol dimethacrylate) (in mol) and barium glass at increasing concentrations from 25 to 60 vol.% (5% increments) were tested. Stress was determined in a universal test machine using acrylic as bonding substrate. Nominal polymerization stress was obtained diving the maximum load by the cross-surface area. Shrinkage was measured using a water picnometer. Elastic modulus was obtained by three-point flexural test. Degree of conversion was determined by FT-Raman spectroscopy. Results. Polymerization stress and shrinkage showed inverse relationships with filler content (R(2) = 0.965 and R(2) = 0.966, respectively). Elastic modulus presented a direct correlation with inorganic content (R(2) = 0.984). Degree of conversion did not vary significantly. Polymerization stress showed a strong direct correlation with shrinkage (R(2) = 0.982) and inverse with elastic modulus (R(2) = 0.966). Significance. High inorganic contents were associated with low polymerization stress values, which can be explained by the reduced volumetric shrinkage presented by heavily filled composites. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To investigate the contributions of BisGMA:TEGDMA and filler content on polymerization stress, along with the influence of variables associated with stress development, namely, degree of conversion, reaction rate, shrinkage, elastic modulus and loss tangent for a series of experimental dental composites. Methods. Twenty formulations with BisGMA: TEGDMA ratios of 3: 7, 4: 6, 5: 5, 6: 4 and 7: 3 and barium glass filler levels of 40, 50, 60 or 70 wt% were studied. Polymerization stress was determined in a tensilometer, inserting the composite between acrylic rods fixed to clamps of a universal test machine and dividing the maximum load recorded by the rods cross-sectional area. Conversion and reaction rate were determined by infra-red spectroscopy. Shrinkage was measured by mercury dilatometer. Modulus was obtained by three-point bending. Loss tangent was determined by dynamic nanoindentation. Regression analyses were performed to estimate the effect of organic and inorganic contents on each studied variable, while a stepwise forward regression identified significant variables for polymerization stress. Results. All variables showed dependence on inorganic concentration and monomeric content. The resin matrix showed a stronger influence on polymerization stress, conversion and reaction rate, whereas filler fraction showed a stronger influence on shrinkage, modulus and loss tangent. Shrinkage and conversion were significantly related to polymerization stress. Significance. Both the inorganic filler concentration and monomeric content affect polymerization stress, but the stronger influence of the resin matrix suggests that it may be possible to reduce stress by modifying resin composition without sacrificing filler content. The main challenge is to develop formulations with low shrinkage without sacrificing degree of conversion. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the radiopacity of Portland cement associated with the following radiopacifying agents: bismuth oxide, zinc oxide, lead oxide, bismuth subnitrate, bismuth carbonate, barium sulfate, iodoform, calcium tungstate, and zirconium oxide. A ratio of 20% radiopacifier and 80% white Portland cement by weight was used for analysis. Pure Portland cement and dentin served as controls. Cement/radiopacifier and dentin disc-shaped specimens were fabricated, and radiopacity testing was performed according to the ISO 6876/2001 standard for dental root sealing materials. Using Insight occlusal films, the specimens were radiographed near to a graduated aluminum stepwedge varying from 2 to 16 mm in thickness. The radiographs were digitized and radiopacity compared with the aluminum stepwedge using Digora software (Orion Corporation Soredex, Helsinki, Finland). The radiographic density data were converted into mmAl and analyzed statistically by analysis of variance and Tukey-Kramer test (alpha = 0.05). The radiopacity of pure Portland cement was significantly lower (p < 0.05) than that of dentin, whereas all cement/radiopacifier mixtures were significantly more radiopaque than dentin and Portland cement alone (p < 0.05). Portland cement/bismuth oxide and Portland cement/lead oxide presented the highest radiopacity values and differed significantly from the other materials (p < 0.05), whereas Portland cement/zinc oxide presented the lowest radiopacity values of all mixtures (p < 0.05). All tested substances presented higher radiopacity than that of dentin and may potentially be added to the Portland cement as radiopacifying agents. However, the possible interference of the radiopacifiers with the setting chemistry, biocompatibility, and physical properties of the Portland cement should be further investigated before any clinical recommendation can be done. (J Endod 2009,35:737-740)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To evaluate the effect of two additives, aldehyde or diketone, on the wear, roughness and hardness of bis-GMA-based composites/copolymers containing TEGDMA, propoxylated bis-GMA (CH(3)bis-GMA) or propoxylated fluorinated bis-GMA (CF(3)bis-GMA). Methods. Fifteen experimental composites and 15 corresponding copolymers were prepared combining bis-GMA and TEGDMA, CH3bis-GMA or CF3bis-GMA, with aldehyde (24mol% and 32 mol%) or diketone (24 mol% and 32 mol%) totaling 30 groups. For composites, hybrid treated filler (barium aluminosilicate glass/pyrogenic silica; 60 wt%) was added to monomer mixtures. Photopolymerization was affected by 0.2 wt% each of camphorquinone and N,N-dimethyl-p-toluidine. Wear (W) test was conducted in a toothbrushing abrasion machine (n = 6) and quantified using a profilometer. Surface roughness (R) changes, before and after abrasion test, were determined using a rugosimeter. Microhardness (H) measurements were performed for dry and wet samples using a Knoop microindenter (n = 6). Data were analyzed by one-way ANOVA and Tukey`s test (alpha = 0.05). Results. Incorporation of additives led to improved W and H values for bis-GMA/TEGDMA and bis-GMA/CH(3)bis-GMA systems. Additives had no significant effect on the W and H changes of bis-GMA/CF(3)bis-GMA. With regard to R changes, additives produced decreased values for bis-GMA/CH3bis-GMA and bis-GMA/CF3bis-GMA composites. Bis-GMA/TEGDMA and bis-GMA/CH(3)bis-GMA copolymers with additives became smoother after abrasion test. Significance. The findings correlate with additives ability to improve degree of conversion of some composites/copolymers thereby enhancing mechanical properties. Published by Elsevier Ltd on behalf of Academy of Dental Materials