984 resultados para apêndice atrial esquerdo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of intranasal administration of increasing doses of synthetic human natriuretic peptide (4-28 hANP) were studied in six healthy volunteers. The peptide was administered as a nasal spray at doses of 50, 100, 200, and 500 micrograms in ascending order at 48-h intervals. Vehicle was administered by the same route randomly between any two of the doses. Intranasal hANP administration had no effect on either blood pressure, heart rate (HR), or hematocrit. Diuresis did not change consistently, whereas natriuresis tended to rise with vehicle as well as with hANP administration. This was attributed to the infusion of isotonic saline during the experiment. There was no significant increase in plasma ANP levels after intranasal administration of any of the different doses. Thus, no evidence that the atrial natriuretic peptide tested (4-28 hANP) can cross the nasal mucosal barrier was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial septal defect (ASD) typically is asymptomatic in infancy and early childhood and elective defect closure usually is performed at an age between 4 - 6 years. Severe pulmonary hypertension (PHT) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PHT complicating an isolated ASD and requiring early surgical correction in the fi rst year of life. 355 pediatric patients underwent treatment for an isolated ASD either surgically or by catheter intervention during a 10 year period (1996 - 2006) at two tertiary referral centers. 297 patients had secundum ASD and 58 primum ASD with mild to moderate mitral regurgitation. 8 infants were found with isolated ASD (six with secundum and two with primum ASD) associated with signifi cant PHT, accounting for 2.2% of all ASD patients in our centers. These 8 infants had invasively measured pulmonary artery pressures between 50 and 100% of systemic pressure. Median size of the ASD at the time of surgery was 14mm (7 - 20). They were operated in the fi rst year of life and had complicated postoperative courses requiring specifi c treatment for PHT for up to 16 weeks (median 12) postoperatively. Compared to ASD patients without PHT these infants had prolonged postoperative ICU stay of 5 - 9 days (median 8) and prolonged perioperative overall hospital stay of 8 - 32 days (median 15). Ultimate outcome in all 8 infants was good with persistent normalization of pulmonary pressures during mid-term follow-up of between 8 to 60 months (median 28). All other ASD patients had normal pulmonary pressures and mean age at defect closure was higher being 6.2 years for secundum ASD and 3.2 years for primum ASD. In conclusion, ASD is rarely associated with signifi cant PHT in infancy but then requires early surgery to normalize the prognosis of the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial septal defects (ASDs) are typically asymptomatic in infancy and early childhood, and elective defect closure is usually performed at ages of 4 to 6 years. Severe pulmonary hypertension (PH) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PH complicating an isolated ASD and requiring early surgical correction. During a 10-year period (1996 to 2006), 355 pediatric patients underwent treatment for isolated ASDs either surgically or by catheter intervention at 2 tertiary referral centers. Two hundred ninety-seven patients had secundum ASDs, and 58 had primum ASDs with mild to moderate mitral regurgitation. Eight infants were found with isolated ASDs (6 with secundum ASDs and 2 with primum ASDs) associated with significant PH, accounting for 2.2% of all patients with ASDs at the centers. These 8 infants had invasively measured pulmonary artery pressures of 50% to 100% of systemic pressure. They were operated in the first year of life and had complicated postoperative courses requiring specific treatment for PH for up to 16 weeks postoperatively. The ultimate outcomes in all 8 infants were good, with persistent normalization of pulmonary pressures during midterm follow-up of up to 60 months (median 28). All other patients with ASDs had normal pulmonary pressures, and the mean age at defect closure was significantly older, at 6.2 years for secundum ASDs and 3.2 years for primum ASDs. In conclusion, ASDs were rarely associated with significant PH in infancy but then required early surgery and were associated with excellent midterm outcomes in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is the most common cardiac arrhythmia. The risk of thromboembolic events is important, and at that time, there is no definite treatment for AF. Oral anticoagulation also represents a hemorrhagic risk factor. Ninety percent of atrial thrombi are located within the left atrial appendage. The percutaneous closure of this left atrial appendage with a device has been shown to decrease thromboembolic events even after interruption of oral anticoagulation as compared to warfarin in a recent randomized study. Recent data support this innovative technique as a reasonable alternative to long term anticoagulation in patients at high risk of bleeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: A shortening of the atrial refractory period has been considered as the main mechanism for the increased risk of atrial fibrillation in hyperthyroidism. However, other important factors may be involved. OBJECTIVE: Our objective was to determine the activity of abnormal supraventricular electrical depolarizations in response to elevated thyroid hormones in patients without structural heart disease. PATIENTS AND DESIGN: Twenty-eight patients (25 females, three males, mean age 43+/-11 yr) with newly diagnosed and untreated hyperthyroidism were enrolled in a prospective trial after exclusion of heart disease. Patients were followed up for 16 +/- 6 months and studied at baseline and 6 months after normalization of serum TSH levels. MAIN OUTCOME MEASURES: The incidence of abnormal premature supraventricular depolarizations (SVPD) and the number of episodes of supraventricular tachycardia was defined as primary outcome measurements before the start of the study. In addition, heart rate oscillations (turbulence) after premature depolarizations and heart rate variability were compared at baseline and follow-up. RESULTS: SVPDs decreased from 59 +/- 29 to 21 +/- 8 per 24 h (P = 0.003), very early SVPDs (so called P on T) decreased from 36 +/- 24 to 3 +/- 1 per 24 h (P < 0.0001), respectively, and nonsustained supraventricular tachycardias decreased from 22 +/- 11 to 0.5 +/- 0.2 per 24 h (P = 0.01) after normalization of serum thyrotropin levels. The hyperthyroid phase was characterized by an increased heart rate (93 +/- 14 vs. 79 +/- 8 beats/min, P < 0.0001) and a decreased turbulence slope (3.6 vs. 9.2, P = 0.003), consistent with decreased vagal tone. This was confirmed by a significant decrease of heart rate variability. CONCLUSION: Hyperthyroidism is associated with an increased supraventricular ectopic activity in patients with normal hearts. The activation of these arrhythmogenic foci by elevated thyroid hormones may be an important causal link between hyperthyroidism and atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS: This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION: Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial arrhythmias (AAs) are a common complication in adult patients with congenital heart disease. We sought to compare the lifetime prevalence of AAs in patients with right- versus left-sided congenital cardiac lesions and their effect on the prognosis. A congenital heart disease diagnosis was assigned using the International Disease Classification, Ninth Revision, diagnostic codes in the administrative databases of Quebec, from 1983 to 2005. Patients with AAs were those diagnosed with an International Disease Classification, Ninth Revision, code for atrial fibrillation or intra-atrial reentry tachycardia. To ensure that the diagnosis of AA was new, a washout period of 5 years after entry into the database was used, a period during which the patient could not have received an International Disease Classification, Ninth Revision, code for AA. The cumulative lifetime risk of AA was estimated using the Practical Incidence Estimators method. The hazard ratios (HRs) for mortality, morbidity, and cardiac interventions were compared between those with right- and left-sided lesions after adjustment for age, gender, disease severity, and cardiac risk factors. In a population of 71,467 patients, 7,756 adults developed AAs (isolated right-sided, 2,229; isolated left-sided, 1,725). The lifetime risk of developing AAs was significantly greater in patients with right- sided than in patients with left-sided lesions (61.0% vs 55.4%, p <0.001). The HR for mortality and the development of stroke or heart failure was similar in both groups (HR 0.96, 95% confidence interval [CI] 0.86 to 1.09; HR 0.94, 95% CI 0.80 to 1.09; and HR 1.10, 95% CI 0.98 to 1.23, respectively). However, the rates of cardiac catheterization (HR 0.63, 95% CI 0.55 to 0.72), cardiac surgery (HR 0.40, 95% CI 0.36 to 0.45), and arrhythmia surgery (HR 0.77, 95% CI 0.6 to 0.98) were significantly less for patients with right-sided lesions. In conclusion, patients with right-sided lesions had a greater lifetime burden of AAs. However, their morbidity and mortality were no less than those with left-sided lesions, although the rate of intervention was substantially different.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: We recently observed in a chronic ovine model that a shortening of action potential duration (APD) as assessed by the activation recovery interval (ARI) may be a mechanism whereby pacing-induced atrial tachycardia (PIAT) facilitates atrial fibrillation (AF), mediated by a return to 1:1 atrial capture after the effective refractory period has been reached. The aim of the present study is to evaluate the effect of long term intermittent burst pacing on ARI before induction of AF.Methods: We specifically developed a chronic ovine model of PIAT using two pacemakers (PM) each with a right atrial (RA) lead separated by ∼2cm. The 1st PM (Vitatron T70) was used to record a broadband unipolar RA EGM (800 Hz, 0.4 Hz high pass filter). The 2nd was used to deliver PIAT during electrophysiological protocols at decremental pacing CL (400 beats, from 400 to 110ms) and long term intermittent RA burst pacing to promote electrical remodeling (5s of burst followed by 2s of sinus rhythm) until onset of sustained AF. ARI was defined as the time difference between the peak of the atrial repolarization wave and the first atrial depolarization. The mean ARIs of paired sequences (before and after remodeling), each consisting of 20 beats were compared.Results: As shown in the figure, ARIs (n=4 sheep, 46 recordings) decreased post remodeling compared to baseline (86±19 vs 103±12 ms, p<0.05). There was no difference in atrial structure as assessed by light microscopy between control and remodeled sheep.Conclusions: Using standard pacemaker technology, atrial ARIs as a surrogate of APDs were successfully measured in vivo during the electrical remodeling process leading to AF. The facilitation of AF by PIAT mimicking salvos from pulmonary veins is heralded by a significant shortening of ARI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Atrial natriuretic peptide (ANP) is a secretory hormone displaying diuretic, natriuretic, and vasorelaxant activities. Recently, its lipolytic activity has been reported. Since the expression of ANP in adipose tissue has not been documented, we used real-time reverse transcriptase polymerase chain reaction (RT-PCR) to investigate the expression of ANP in human adipose tissue and preadipocytes. RESEARCH METHODS AND PROCEDURES: RNA was extracted from the human adipose tissue of severely obese premenopausal women as well as from human preadipocytes. For human preadipocytes, two cell systems were investigated: the human preadipose immortalized (Chub-S7) cells, a well-characterized human preadipose cell line, and primary preadipocytes derived from the stromal vascular fraction of the human adipose tissue. We measured the mRNA of ANP, of corin (a transmembrane serine protease involved in the conversion of pro-ANP to ANP) and of uncoupling protein 2 (UCP2; a control gene known to be ubiquitously expressed). The expression of ANP was also investigated using immunofluorescence and radioimmunoassay in Chub-S7 cells and human primary preadipocytes in culture. RESULTS: Our results indicate that ANP and corin are expressed at the mRNA level in human adipose tissue and preadipocytes. Immunofluorescence experiments demonstrated that pro-ANP was expressed in Chub-S7 cells. In addition, ANP secretion could be measured in Chub-S7 cells and human primary preadipocytes in culture. Rosiglitazone, a selective peroxisome proliferator-activated receptor type gamma (PPAR-gamma) agonist promoting adipocyte differentiation, was found to modulate both ANP expression and secretion in preadipocytes. DISCUSSION: Our findings suggest the existence of an autocrine/paracrine system for ANP in the human adipose tissue whose implications in lipolysis and cardiovascular function need to be further explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two doses of synthetic atrial natriuretic peptide (0.5 and 5.0 micrograms/min) and its vehicle were infused intravenously for 4 hours in eight salt-loaded normal volunteers, and the effect on blood pressure, heart rate, renal hemodynamics, solute excretion, and secretion of vasoactive hormones was studied. The 0.5 micrograms/min infusion did not alter blood pressure or heart rate, whereas the 5.0 micrograms/min infusion significantly reduced the mean pressure by 20/9 mm Hg after 2.5 to 3 hours and increased the heart rate slightly. Inulin clearance was not significantly changed, but the mean p-aminohippurate clearance fell by 13 and 32% with the lower and higher doses, respectively. Urinary excretion of sodium and chloride increased slightly with the lower dose. With the higher dose, a marked increase in urinary excretion of sodium, chloride, and calcium was observed, reaching a peak during the second hour of the infusion. Potassium and phosphate excretion did not change significantly. A brisk increase in urine flow rate and fractional water excretion was seen only during the first hour of the high-dose infusion. Signs and symptoms of hypotension were observed in two subjects. No change in plasma renin activity, angiotensin II, or aldosterone was observed during either infusion, but a marked increase occurred after discontinuation of the high-dose infusion. In conclusion, the 5 micrograms/min infusion induced a transient diuretic effect, delayed maximal natriuretic activity, and a late fall in blood pressure, with no change in inulin clearance but a dose-related decrease in p-aminohippurate clearance. Despite large amounts of sodium excreted and blood pressure reduction, no counterregulatory changes were observed in the renin-angiotensin-aldosterone system or plasma vasopressin levels during the infusion.

Relevância:

20.00% 20.00%

Publicador: