952 resultados para angular correlation coefficient
Resumo:
PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.
Resumo:
This study was carried out to assess the genetic variability of ten "cagaita" tree (Eugenia dysenterica) populations in Southeastern Goiás. Fifty-four randomly amplified polymorphic DNA (RAPD) loci were used to characterize the population genetic variability, using the analysis of molecular variance (AMOVA). A phiST value of 0.2703 was obtained, showing that 27.03% and 72.97% of the genetic variability is present among and within populations, respectively. The Pearson correlation coefficient (r) among the genetic distances matrix (1 - Jaccard similarity index) and the geographic distances were estimated, and a strong positive correlation was detected. Results suggest that these populations are differentiating through a stochastic process, with restricted and geographic distribution dependent gene flow.
Resumo:
BACKGROUND: To compare morphological gross tumor volumes (GTVs), defined as pre- and postoperative gadolinium enhancement on T1-weighted magnetic resonance imaging to biological tumor volumes (BTVs), defined by the uptake of (18)F fluoroethyltyrosine (FET) for the radiotherapy planning of high-grade glioma, using a dedicated positron emission tomography (PET)-CT scanner equipped with three triangulation lasers for patient positioning. METHODS: Nineteen patients with malignant glioma were included into a prospective protocol using FET PET-CT for radiotherapy planning. To be eligible, patients had to present with residual disease after surgery. Planning was performed using the clinical target volume (CTV = GTV union or logical sum BTV) and planning target volume (PTV = CTV + 20 mm). First, the interrater reliability for BTV delineation was assessed among three observers. Second, the BTV and GTV were quantified and compared. Finally, the geometrical relationships between GTV and BTV were assessed. RESULTS: Interrater agreement for BTV delineation was excellent (intraclass correlation coefficient 0.9). Although, BTVs and GTVs were not significantly different (p = 0.9), CTVs (mean 57.8 +/- 30.4 cm(3)) were significantly larger than BTVs (mean 42.1 +/- 24.4 cm(3); p < 0.01) or GTVs (mean 38.7 +/- 25.7 cm(3); p < 0.01). In 13 (68%) and 6 (32%) of 19 patients, FET uptake extended >or= 10 and 20 mm from the margin of the gadolinium enhancement. CONCLUSION: Using FET, the interrater reliability had excellent agreement for BTV delineation. With FET PET-CT planning, the size and geometrical location of GTVs and BTVs differed in a majority of patients.
Resumo:
The major objective of this research project was to use thermal analysis techniques in conjunction with x-ray analysis methods to identify and explain chemical reactions that promote aggregate related deterioration in portland cement concrete. Twenty-two different carbonate aggregate samples were subjected to a chemical testing scheme that included: • bulk chemistry (major, minor and selected trace elements) • bulk mineralogy (minor phases concentrated by acid extraction) • solid-solution in the major carbonate phases • crystallite size determinations for the major carbonate phases • a salt treatment study to evaluate the impact of deicer salts Test results from these different studies were then compared to information that had been obtained using thermogravimetric analysis techniques. Since many of the limestones and dolomites that were used in the study had extensive field service records it was possible to correlate many of the variables with service life. The results of this study have indicated that thermogravimetric analysis can play an important role in categorizing carbonate aggregates. In fact, with modern automated thermal analysis systems it should be possible to utilize such methods on a quality control basis. Strong correlations were found between several of the variables that were monitored in this study. In fact, several of the variables exhibited significant correlations to concrete service life. When the full data set was utilized (n = 18), the significant correlations to service life can be summarized as follows ( a = 5% level): • Correlation coefficient, r, = -0.73 for premature TG loss versus service life. • Correlation coefficient, r, = 0.74 for relative crystallite size versus service life. • Correlation coefficient, r, = 0.53 for ASTM C666 durability factor versus service life. • Correlation coefficient, r, = -0.52 for acid-insoluble residue versus service life. Separation of the carbonate aggregates into their mineralogical categories (i.e., calcites and dolomites) tended to increase the correlation coefficients for some specific variables (r sometimes approached 0.90); however, the reliability of such correlations was questionable because of the small number of samples that were present in this study.
Resumo:
Simulated-annealing-based conditional simulations provide a flexible means of quantitatively integrating diverse types of subsurface data. Although such techniques are being increasingly used in hydrocarbon reservoir characterization studies, their potential in environmental, engineering and hydrological investigations is still largely unexploited. Here, we introduce a novel simulated annealing (SA) algorithm geared towards the integration of high-resolution geophysical and hydrological data which, compared to more conventional approaches, provides significant advancements in the way that large-scale structural information in the geophysical data is accounted for. Model perturbations in the annealing procedure are made by drawing from a probability distribution for the target parameter conditioned to the geophysical data. This is the only place where geophysical information is utilized in our algorithm, which is in marked contrast to other approaches where model perturbations are made through the swapping of values in the simulation grid and agreement with soft data is enforced through a correlation coefficient constraint. Another major feature of our algorithm is the way in which available geostatistical information is utilized. Instead of constraining realizations to match a parametric target covariance model over a wide range of spatial lags, we constrain the realizations only at smaller lags where the available geophysical data cannot provide enough information. Thus we allow the larger-scale subsurface features resolved by the geophysical data to have much more due control on the output realizations. Further, since the only component of the SA objective function required in our approach is a covariance constraint at small lags, our method has improved convergence and computational efficiency over more traditional methods. Here, we present the results of applying our algorithm to the integration of porosity log and tomographic crosshole georadar data to generate stochastic realizations of the local-scale porosity structure. Our procedure is first tested on a synthetic data set, and then applied to data collected at the Boise Hydrogeophysical Research Site.
Resumo:
The objective of this work was to determine soybean resistance inheritance to Heterodera glycines Ichinohe (soybean cyst nematode - SCN) races 3 and 9, as well as to evaluate the efficiency of direct and indirect selection in a soybean population of 112 recombinant inbred lines (RIL) derived from the resistant cultivar Hartwig. The experiment was conducted in a completely randomized design, in Londrina, PR, Brazil. The estimated narrow-sense heritabilities for resistance to races 3 and 9 were 80.67 and 77.97%. The genetic correlation coefficient (r g = 0.17; p<0.01) shows that some genetic components of resistance to these two races are inherited together. The greatest genetic gain by indirect selection was obtained to race 9, selecting to race 3 due to simpler inheritance of resistance to race 9 and not because these two races share common resistance genes. The resistance of cultivar Hartwig to races 3 and 9 is determined by 4 and 2 genes, respectively. One of these genes confers resistance to both races, explaining a fraction of the significant genetic correlation found between resistance to these SCN races. The inheritance pattern described indicates that selection for resistance to SCN must be performed for each race individually.
Resumo:
The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces.
Resumo:
BACKGROUND: Controversy exists regarding the usefulness of troponin testing for the risk stratification of patients with acute pulmonary embolism (PE). We conducted an updated systematic review and a metaanalysis of troponin-based risk stratification of normotensive patients with acute symptomatic PE. The sources of our data were publications listed in Medline and Embase from 1980 through April 2008 and a review of cited references in those publications. METHODS: We included all studies that estimated the relation between troponin levels and the incidence of all-cause mortality in normotensive patients with acute symptomatic PE. Two reviewers independently abstracted data and assessed study quality. From the literature search, 596 publications were screened. Nine studies that consisted of 1,366 normotensive patients with acute symptomatic PE were deemed eligible. Pooled results showed that elevated troponin levels were associated with a 4.26-fold increased odds of overall mortality (95% CI, 2.13 to 8.50; heterogeneity chi(2) = 12.64; degrees of freedom = 8; p = 0.125). Summary receiver operating characteristic curve analysis showed a relationship between the sensitivity and specificity of troponin levels to predict overall mortality (Spearman rank correlation coefficient = 0.68; p = 0.046). Pooled likelihood ratios (LRs) were not extreme (negative LR, 0.59 [95% CI, 0.39 to 0.88]; positive LR, 2.26 [95% CI, 1.66 to 3.07]). The Begg rank correlation method did not detect evidence of publication bias. CONCLUSIONS: The results of this metaanalysis indicate that elevated troponin levels do not adequately discern normotensive patients with acute symptomatic PE who are at high risk for death from those who are at low risk for death.
Resumo:
Aim: Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, notably because of lack of validated tools, in accordance with recognized psychometric criteria. The Spinal Function Sort (SFS), developed according to actual standards, was only validated in English. The aim of this study is to translate, adapt and validate the French and German version of the SFS.Method and material: The translation and cross-cultural adaptation were performed following the methodology proposed by the American Association of Orthopedist Surgeon. A total of 344 patients, presenting varied back complaints (especially degenerative and traumatic), took part in this study in a tertiary French- (n=87; mean age 44y; 17 women) and German-speaking (n=257; mean age 41y; 53 women) center. Test-retest reliability was quantified using the intraclass correlation coefficient (ICC) and construct validity was assessed by estimating the Pearson's correlation with the SF-36 physical and mental scales, the Visual Analogue Scale for Pain Intensity (VAS), and subscales of the Hospital Anxiety and Depression Scale (HADS).Results: Respectively for the French and German version, ICC were 0.98 and 0.94. Correlations 0.63 and 0.67 with the SF-36 Physical Functioning subscale; 0.60 and 0.52 with the SF-36 Physical Summary Scale ; -0.33 and -0.51 with the VAS ; -0.08 and 0.25 with the SF-36 Mental Health scale; 0.01 and 0.28 with the SF-36 Mental Summary Scale; -0.26 and -0.42 with the HADS depression; -0.17 and -0.45 with the HADS anxiety.Discussion: For both the French and German version of the SFS, the reliability was excellent. Convergent construct validity with SF-36 physical scales is good, moderated with the VAS. We find out a low correlation with SF-36 mental scales (divergent construct validity). We find out a low correlation with HADS subscales in the French version, and a moderate one in the German version. Selection bias, chronicity of the complaints, as well as cultural differences could explain these results. In conclusion, both the French and German version of the SFS are valid and reliable for evaluation of perceived functional capacity for patients with back complaints.
Resumo:
Background: Thus far, the correlation of noninvasive markers with endoscopic activity in ulcerative colitis (UC) according to the modified Baron Index is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), blood leukocytes, and the Lichtiger Index (clinical score). Methods: UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically in an independent fashion. Fecal and blood samples were analyzed in UC patients and controls. Results: We enrolled 228 UC patients and 52 controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), and leukocytes (r = 0.401). FC was the only marker discriminating between different grades of endoscopic activity (grade 0, 20}11 mg/g; grade 1, 44}34 mg/g; grade 2, 111}74 mg/g; grade 3, 330}332 mg/g; grade 4, 659}319 mg/g; P = 0.0018 for discriminating grade 0 vs. 1 and P < 0.001 for discriminating all other grades). FC had the highest overall accuracy (91%) to detect endoscopically active disease (modified Baron Index _2), followed by the Lichtiger Index of _4 (77%), CRP larger than 5 mg/L (69%) and blood leukocytosis (58%). Conclusions: FC better correlated with the endoscopic disease activity than clinical activity, CRP, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.
Resumo:
We tested the performance of transcutaneous oxygen monitoring (TcPO2) and pulse oximetry (tcSaO2) in detecting hypoxia in critically ill neonatal and pediatric patients. In 54 patients (178 data sets) with a mean age of 2.4 years (range 1 to 19 years), arterial saturation (SaO2) ranged from 9.5 to 100%, and arterial oxygen tension (PaO2) from 16.4 to 128 mmHg. Linear correlation analysis of pulse oximetry vs measured SaO2 revealed an r value of 0.95 (p less than 0.001) with an equation of y = 21.1 + 0.749x, while PaO2 vs tcPO2 showed a correlation coefficient of r = 0.95 (p less than 0.001) with an equation of y = -1.04 + 0.876x. The mean difference between measured SaO2 and tcSaO2 was -2.74 +/- 7.69% (range +14 to - 29%) and the mean difference between PaO2 and tcPO2 was +7.43 +/- 8.57 mmHg (range -14 to +49 mmHg). Pulse oximetry was reliable at values above 65%, but was inaccurate and overestimated the arterial SaO2 at lower values. TcPO2 tended to underestimate the arterial value with increasing PaO2. Pulse oximetry had the best sensitivity to specificity ratio for hypoxia between 65 and 90% SaO2; for tcPO2 the best results were obtained between 35 and 55 mmHg PaO2.
Resumo:
The stop-loss reinsurance is one of the most important reinsurance contracts in the insurance market. From the insurer point of view, it presents an interesting property: it is optimal if the criterion of minimizing the variance of the cost of the insurer is used. The aim of the paper is to contribute to the analysis of the stop-loss contract in one period from the point of view of the insurer and the reinsurer. Firstly, the influence of the parameters of the reinsurance contract on the correlation coefficient between the cost of the insurer and the cost of the reinsurer is studied. Secondly, the optimal stop-loss contract is obtained if the criterion used is the maximization of the joint survival probability of the insurer and the reinsurer in one period.
Resumo:
OBJECTIVES: The purpose of this study was to compare myocardial blood flow (MBF) and myocardial flow reserve (MFR) estimates from rubidium-82 positron emission tomography ((82)Rb PET) data using 10 software packages (SPs) based on 8 tracer kinetic models. BACKGROUND: It is unknown how MBF and MFR values from existing SPs agree for (82)Rb PET. METHODS: Rest and stress (82)Rb PET scans of 48 patients with suspected or known coronary artery disease were analyzed in 10 centers. Each center used 1 of 10 SPs to analyze global and regional MBF using the different kinetic models implemented. Values were considered to agree if they simultaneously had an intraclass correlation coefficient >0.75 and a difference <20% of the median across all programs. RESULTS: The most common model evaluated was the Ottawa Heart Institute 1-tissue compartment model (OHI-1-TCM). MBF values from 7 of 8 SPs implementing this model agreed best. Values from 2 other models (alternative 1-TCM and Axially distributed) also agreed well, with occasional differences. The MBF results from other models (e.g., 2-TCM and retention) were less in agreement with values from OHI-1-TCM. CONCLUSIONS: SPs using the most common kinetic model-OHI-1-TCM-provided consistent results in measuring global and regional MBF values, suggesting that they may be used interchangeably to process data acquired with a common imaging protocol.
Resumo:
PURPOSE: The primary objective of this study was to describe the frequency of behaviors observed during rest, a non-nociceptive procedure, and a nociceptive procedure in brain-injured intensive care unit (ICU) patients with different levels of consciousness (LOC). Second, it examined the inter-rater reliability and discriminant and concurrent validity of the behavioral checklist used. METHODS: The non-nociceptive procedure involved calling the patient and shaking his/her shoulder. The nociceptive procedure involved turning the patient. The frequency of behaviors was recorded using a behavioral checklist. RESULTS: Patients with absence of movement, or stereotyped flexion or extension responses to a nociceptive stimulus displayed more behaviors during turning (median 5.5, range 0-14) than patients with localized responses (median 4, range 0-10) or able to self-report their pain (median 4, range 0-10). Face flushing, clenched teeth, clenched fist, and tremor were more frequent in patients with absence of movement, or stereotyped responses to a nociceptive stimulus. The reliability of the checklist was supported by a high intra-class correlation coefficient (0.77-0.92), and the internal consistency was acceptable in all three groups (KR 20, 0.71-0.85). Discriminant validity was supported as significantly more behaviors were observed during nociceptive stimulation than at rest. Concurrent validity was confirmed as checklist scores were correlated to the patients' self-reports of pain (r s = 0.53; 95 % CI 0.21-0.75). CONCLUSION: Brain-injured patients reacted significantly more during a nociceptive stimulus and the number of observed behaviors was higher in patients with a stereotyped response.
Resumo:
BACKGROUND AND PURPOSE: The ASTRAL score was recently introduced as a prognostic tool for acute ischemic stroke. It predicts 3-month outcome reliably in both the derivation and the validation European cohorts. We aimed to validate the ASTRAL score in a Chinese stroke population and moreover to explore its prognostic value to predict 12-month outcome. METHODS: We applied the ASTRAL score to acute ischemic stroke patients admitted to 132 study sites of the China National Stroke Registry. Unfavorable outcome was assessed as a modified Rankin Scale score >2 at 3 and 12 months. Areas under the curve were calculated to quantify the prognostic value. Calibration was assessed by comparing predicted and observed probability of unfavorable outcome using Pearson correlation coefficient. RESULTS: Among 3755 patients, 1473 (39.7%) had 3-month unfavorable outcome. Areas under the curve for 3 and 12 months were 0.82 and 0.81, respectively. There was high correlation between observed and expected probability of unfavorable 3- and 12-month outcome (Pearson correlation coefficient: 0.964 and 0.963, respectively). CONCLUSIONS: ASTRAL score is a reliable tool to predict unfavorable outcome at 3 and 12 months after acute ischemic stroke in the Chinese population. It is a useful tool that can be readily applied in clinical practice to risk-stratify acute stroke patients.