940 resultados para anaerobic wastewater treatment


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increasing volume of urban sewage nowadays generates considerable amount of sludge to be disposed of. One environmentally adequate destination could be the application of treated and stabilized sludge (biosolids) to forest plantations as fertilizer and soil conditioner. The purpose of this study was to analyze the feasibility of applying sewage sludge, evaluating its effects on native tree seedlings. The species evaluated were aroeira-pimenteira (Schinus terebinthifolia Raddi), cabreuva-vermelha (Myroxy-Ion peruiferum L. f.), pau-de-viola (Cytarexyllum myrianthum Cham), unha-de-vaca (Bauhinia forficata Link), which are usually planted in forest restoration. Seedlings were cultivated in pots, containing a volume of 4 dm(3) of soil, within a greenhouse. The study was developed in the proximity of Campinas, SP, Brazil, and installed in November, 2003. The design was entirely randomized including seven treatments: control; mineral fertilization; and different doses of sewage sludge (biosolids) complemented with potassium, due to the low concentration of this element in the sludge produced by the wastewater treatment plant of Barueri (Metropolitan region of Sao Paulo city). The results showed that the application of different dosages of biosolids promoted different responses in stem height and biomass production. The treatment with 20 g/dm(3) of dry sewage sludge promoted both the highest growth and the highest seedling biomass production, compared to the control treatment. All native tree species treated with the highest dosage of sewage sludge showed a growth similar to that of mineral fertilization. The seedlings of aroeira-pimenteira, pau-de-viola, and unha-de-vaca, all typical species of the initial succession in natural forest ecosystems, grew and produced more biomass than cabreuva-vermelha, a typical species of the final forest succession.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Activated sludge flocculation was modelled using population balances. The model followed the dynamics of activated sludge flocculation providing a good approximation of the change in mean floe size with time. Increasing the average velocity gradient decreased the final floe size. The breakage rate coefficient and collision efficiency also varied with the average velocity gradient. A power law relationship was found for the increase in breakage rate coefficient with increasing average velocity gradient. Further investigation will be conducted to determine the relationship between the collision efficiency and particle size to provide a better approximation of dynamic changes in the floe size distribution during flocculation. (C) 2002 Published by Elsevier Science B.V.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A molecular approach was used to investigate a recently described candidate division of the domain Bacteria, TM7, currently known only from environmental 16S ribosomal DNA sequence data, A number of TM7-specific primers and probes were designed and evaluated. Fluorescence in situ hybridization (FISH) of a laboratory scale bioreactor using two independent TM7-specific probes revealed a conspicuous sheathed-filament morphotype, fortuitously enriched in the reactor. Morphologically, the filament matched the description of the Eikelboom morphotype 0041-0675 widely associated with bulking problems in activated-sludge wastewater treatment systems. Transmission electron microscopy of the bioreactor sludge demonstrated that the sheathed-filament morphotype had a typical gram-positive cell envelope ultrastructure. Therefore, TM7 is only the third bacterial lineage recognized to have gram-positive representatives. TM7-specific FISH analysis of two full-scale wastewater treatment plant sludges, including the one used to seed the laboratory scale reactor, indicated the presence of a number of morphotypes, including sheathed filaments. TM7-specific PCR clone libraries prepared from the two full-scale sludges yielded 23 novel TM7 sequences. Three subdivisions could be defined based on these data and publicly available sequences. Environmental sequence data and TM7-specific FISH analysis indicate that members of the TM7 division are present in a variety of terrestrial, aquatic, and clinical habitats. A highly atypical base substitution (Escherichia coli position 912; C to U) for bacterial 16S rRNAs was present in almost all TM7 sequences, suggesting that TM7 bacteria, like Archaea, may be streptomycin resistant at the ribosome level.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with the existing infrastructure, and which will be of a sufficiently high standard to meet not only the requirements of imposed environmental legislation but also BP's environmental objectives. A number of challenges were faced when considering the upgrade, particularly; cost constraints and limited plot space, highly variable wastewater, toxicity issues, and limited available hydraulic head. Sequencing Batch Reactor (SBR) Technology was chosen for the lagoon upgrade based on the following; SBR technology allowed a retro-fit of the existing earthen lagoon without the need for any additional substantial concrete structures, a dual lagoon system allowed partial treatment of wastewaters during construction, SBRs give substantial process flexibility, SBRs have the ability to easily modify process parameters without any physical modifications, and significant cost benefits. This paper presents the background to this application, an outline of laboratory studies carried out on the wastewater and details the full scale design issues and methods for providing a cost effective, efficient treatment system using the existing lagoon system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In Part 1 of this paper a methodology for back-to-back testing of simulation software was described. Residuals with error-dependent geometric properties were generated. A set of potential coding errors was enumerated, along with a corresponding set of feature matrices, which describe the geometric properties imposed on the residuals by each of the errors. In this part of the paper, an algorithm is developed to isolate the coding errors present by analysing the residuals. A set of errors is isolated when the subspace spanned by their combined feature matrices corresponds to that of the residuals. Individual feature matrices are compared to the residuals and classified as 'definite', 'possible' or 'impossible'. The status of 'possible' errors is resolved using a dynamic subset testing algorithm. To demonstrate and validate the testing methodology presented in Part 1 and the isolation algorithm presented in Part 2, a case study is presented using a model for biological wastewater treatment. Both single and simultaneous errors that are deliberately introduced into the simulation code are correctly detected and isolated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a comprehensive study of sludge floc characteristics and their impact on compressibility and settleability of activated sludge in full scale wastewater treatment processes. The sludge flocs were characterised by morphological (floc size distribution, fractal dimension, filament index), physical (flocculating ability, viscosity, hydrophobicity and surface charge) and chemical (polymeric constituents and metal content) parameters. Compressibility and settleability were defined in terms of the sludge volume index (SVI) and zone settling velocity (ZSV). The floc morphological and physical properties had important influence on the sludge compressibility and settleability. Sludges containing large flocs and high quantities of filaments, corresponding to lower values of fractal dimension (D-f), demonstrated poor compressibility and settleability. Sludge flocs with high flocculating ability had lower SVI and higher ZSV, whereas high values of hydrophobicity, negative surface charge and viscosity of the sludge flocs correlated to high SVI and low ZSV. The quantity of the polymeric compounds protein. humic substances and carbohydrate in the sludge and the extracted extracellular polymeric substances (EPS) had significant positive correlations with SVI. The ZSV was quantitatively independent of the polymeric constituents. High concentrations of the extracted EPS were related to poor compressibility and settleability. The cationic ions Ca, Mg, Al and Fe in the sludge improved significantly the sludge compressibility and settleability. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper examines the influence of the chemical constituents of activated sludge and extracted extracellular polymeric substances (EPS) on the surface properties, hydrophobicity, surface charge (SC) and flocculating ability (FA) of activated sludge floes. Activated sludge samples from 7 different full-scale wastewater treatment plants were examined. Protein and humic substances were found to be the dominant polymeric compounds in the activated sludges and the extracted EPS, and they significantly affected the FA and surface properties, hydrophobicity and SC, of the sludge floes. The polymeric compounds proteins, humic substances and carbohydrates in the sludge floes and the extracted EPS contributed to the negative SC, but correlated negatively to the hydrophobicity of sludge floes. The quantity of protein and carbohydrate within the sludge and the extracted EPS was correlated positively to the FA of the sludge floes, while increased amounts of humic substances resulted in lower FA. In contrast, increased amounts of total extracted EPS had a negative correlation to FA. The results reveal that the quality and quantity of the polymeric compounds within the sludge floes is more informative, with respect to understanding the mechanisms involved in flocculation, than if only the extracted EPS are considered. This is an important finding as it indicates that extracting EPS may be insufficient to characterise the EPS. This is due to the low extraction efficiency and difficulties involved in the separation of EPS from other organic compounds. Correlations were observed between the surface properties and FA of the sludge floes., This confirms that the surface properties of the, sludge flocs play an important role in the bioflocculation process but that also other interactions like polymer entanglement are important. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The integrated control of nitrate recirculation and external carbon addition in a predenitrification biological wastewater treatment system is studied. The proposed control structure consists of four feedback control loops, which manipulate the nitrate recirculation and the carbon dosage flows in a highly coordinated manner such that the consumption of external carbon is minimised while the nitrate discharge limits (based on both grab and composite samples) are met. The control system requires the measurement of the nitrate concentrations at the end of both the anoxic and the aerobic zones. Distinct from ordinary control systems, which typically minimise the variation in the controlled variables, the proposed control system essentially maximises the diurnal variation of the effluent nitrate concentration and through this maximises the use of influent COD for denitrification, thus minimising the requirement for external carbon source. Simulation studies using a commonly accepted simulation benchmark show that the controlled system consistently achieves the designated effluent quality with minimum costs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biological nitrogen removal via nitrite pathway in wastewater treatment is very important especially in the cost of aeration and as an electron donor for denitrification. Wastewater nitrification and nitrite accumulations were carried out in a biofilm reactor. The biofilm reactor showed almost complete nitrification and most of the oxidized ammonium was present as nitrite at the ammonium load of 1.2 kg N/m3/d. Nitrite accumulation was achieved by the selective inhibition of nitrite oxidizers by free ammonia and oxygen limitation. Nitrite oxidation activity was recovered as soon as the inhibition factor was removed. Fluorescence in situ hybridization studies of the nitrite accumulating biofilm system have shown that genus Nitrosomonas which is specifically hybridized with probe NSM 156 was the dominant nitrifying bacteria while Nitrospira was less abundant than those of normal nitrification systems. Further FISH analysis showed that the combinations of Nitrosomonas and Nitrospira cells were identified as important populations of nitrifying bacteria in an autotrophic nitrifying biofilm system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Most of the wastewater treatment systems in small rural communities of the Cova da Beira region (Portugal) consist of constructed wetlands (CW) with horizontal subsurface flow (HSSF). It is believed that those systems allow the compliance of discharge standards as well as the production of final effluents with suitability for reuse. Results obtained in a nine-month campaign in an HSSF bed pointed out that COD and TSS removal were lower than expected. A discrete sampling also showed that removal of TC, FC and HE was not enough to fulfill international irrigation goals. However, the bed had a very good response to variation of incoming nitrogen loads presenting high removal of nitrogen forms. A good correlation between mass load and mass removal rate was observed for BOD5, COD, TN, NH4-N, TP and TSS, which shows a satisfactory response of the bed to the variable incoming loads. The entrance of excessive loads of organic matter and solids contributed for the decrease of the effective volume for pollutant uptake and therefore, may have negatively influenced the treatment capability. Primary treatment should be improved in order to decrease the variation of incoming organic and solid loads and to improve the removal of COD, solids and pathogenic. The final effluent presented good physical-chemical quality to be reused for irrigation, which is the most likely application in the area.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A água é um bem essencial ao ser humano. Nos dias de hoje é de extrema importância fazer chegar este bem às populações, um papel que no nosso país é desempenhado pelos municípios, por empresas municipais e por empresas concessionadas. Este relatório, enquadrado no âmbito do trabalho final de mestrado em Engenharia Civil, especialização em Hidráulica, no Instituto Superior de Engenharia de Lisboa, cujo título é “Conservação, Manutenção e Construção de Património Estratégico das Águas de Santarém”, relata a experiência de estágio do autor do presente relatório na A.S. – Empresa das Águas de Santarém – EM, S.A. O relatório aborda as temáticas do abastecimento de água, do tratamento de águas residuais, da construção de sistemas de saneamento e estações de tratamento de águas residuais, da reparação de equipamentos da empresa e do consumo de energia dos equipamentos da empresa. São descritas as actividades desenvolvidas pelo autor, que incluem o acompanhamento activo em visitas a obras de construção e manutenção de património, a monitorização e controlo de perdas de água, bem como a actualização em suporte informático do cadastro dos equipamentos pertencentes à A.S., com a criação de fichas de equipamento individuais e de um suporte informático para registo e consulta comparativa de consumos energéticos. Esta experiência de estágio permitiu ao autor um contacto com a realidade de uma empresa em toda a diversidade das actividades anteriormente nomeadas, que será descrita objectivamente nos capítulos do presente documento. O estágio foi claramente enriquecedor para o autor, fornecendo-lhe formação objectiva e a preparação necessária para a sua integração no mercado de trabalho nesta área específica da Engenharia Civil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A presente tese teve por base a identificação e resolução de um problema existente no tratamento de efluentes provenientes dos processos de tratamento de superfícies por galvanoplastia, na OGMA – Indústria Aeronáutica de Portugal S.A.. Observou-se a ocorrência, esporádica, de crómio hexavalente, (Cr (VI)), em valor superior ao valor limite de emissão (VLE). Os resultados foram monitorizados e os dados recolhidos no decorrer da actividade de tratamento de efluentes, durante o período de, aproximadamente, 5 anos (2006 a 2011). A recolha de resultados decorreu no âmbito da actividade profissional da mestranda, que, para além da responsabilidade técnica dos processos de galvanoplastia na empresa, é também responsável pelo suporte técnico ao processo de tratamento de efluentes resultantes da actividade de tratamento de superficies por processos de galvanoplastia. A empresa OGMA – Indústria Aeronáutica de Portugal S.A., é uma empresa de actividade aeronáutica dedicada à Fabricação e Manutenção de aeronaves, nomeadamente a prestação de serviços de Manutenção, Revisão e Modernização de, Aeronaves, Motores e Componentes, bem como Fabricação e Montagem de Aeroestruturas. Integrada na OGMA, S.A. encontra-se a área de tratamentos electroquímicos, onde são realizados processos de tratamento de materiais metálicos por electrodeposição, deposição química e conversão química. Desta actividade resulta uma quantidade considerável de efluentes líquidos que necessitam de tratamento adequado previamente à sua descarga em cursos de água. Devido ao tipo de contaminantes que estes efluentes possuem, o tratamento dos mesmos é realizado em várias etapas, passando pela oxidação de cianetos, a redução de cromatos e a neutralização. Posteriormente segue-se uma sedimentação e a remoção de lamas. De modo a garantir um controlo dos parâmetros de descarga dos efluentes tratados, de acordo com a legislação ambiental em vigor, o efluente obtido é analisado periodicamente em laboratório acreditado. Na perspectiva de solucionar o problema em questão, procedeu-se à realização de ensaios experimentais utilizando os efluentes provenientes dos tanques de reacção da redução de cromatos e da oxidação de cianetos da linha com cádmio, com especial incidência na variação dos intervalos de pH recomendados para cada uma das fases do tratamento de efluentes, e observação do comportamento das misturas em termos de presença de Cr (VI), quando sujeitos a variações de pH. Após análise dos dados disponíveis e realização de todos os ensaios, conclui-se que, o processo de oxidação de cianeto da linha com cádmio e o processo de redução de cromatos na mesma linha estão a funcionar adequadamente. Concluiu-se que o reaparecimento de Cr (VI) ocorre devido à existência de hipoclorito de sódio, em excesso, no tanque de oxidação de cianeto que, quando passa para o tanque de neutralização e entra em contacto com o efluente proveniente do tanque de redução de cromatos, oxida parte do crómio trivalente, (Cr (III)), existente, a Cr (VI). Para impedir a ocorrência deste fenómeno separou-se todo o efluente contendo crómio que passou a ser tratado na linha de tratamento de efluentes isenta de cádmio, não entrando assim em contacto com o efluente que contém hipoclorito não reagido, evitando a oxidação do Cr (III) a Cr (VI).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reclaimed water from small wastewater treatment facilities in the rural areas of the Beira Interior region (Portugal) may constitute an alternative water source for aquifer recharge. A 21-month monitoring period in a constructed wetland treatment system has shown that 21,500 m(3) year(-1) of treated wastewater (reclaimed water) could be used for aquifer recharge. A GIS-based multi-criteria analysis was performed, combining ten thematic maps and economic, environmental and technical criteria, in order to produce a suitability map for the location of sites for reclaimed water infiltration. The areas chosen for aquifer recharge with infiltration basins are mainly composed of anthrosol with more than 1 m deep and fine sand texture, which allows an average infiltration velocity of up to 1 m d(-1). These characteristics will provide a final polishing treatment of the reclaimed water after infiltration (soil aquifer treatment (SAT)), suitable for the removal of the residual load (trace organics, nutrients, heavy metals and pathogens). The risk of groundwater contamination is low since the water table in the anthrosol areas ranges from 10 m to 50 m. Oil the other hand, these depths allow a guaranteed unsaturated area suitable for SAT. An area of 13,944 ha was selected for study, but only 1607 ha are suitable for reclaimed water infiltration. Approximately 1280 m(2) were considered enough to set up 4 infiltration basins to work in flooding and drying cycles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente relatório enquadra-se no âmbito do trabalho final de Mestrado do curso de Engenharia Civil, área de especialização de Hidráulica, pelo Instituto Superior de Engenharia de Lisboa, sobre a temática de construção de ETAR’s. O estágio decorreu na empresa COBENG Construtora, Lda., e teve como fim a prestação de serviços para a SIMARSUL – Sistema Integrado Multimunicipal de Águas Residuais da Península de Setúbal, S.A. O objectivo baseou-se no acompanhamento e participação de todo o processo construtivo deste tipo de estruturas com vista a proporcionar um bom sistema hidráulico na ETAR da herdade do Montado. A obra consistiu na remodelação e implantação de uma nova fase de tratamento (Tratamento Terciário por microtamisagem e raios UV) na ETAR existente que por razões diversas foi sendo incapaz de responder da melhor forma às solicitações impostas, pela população servida, no tratamento das águas residuais. Ao longo dos trabalhos foram encontradas diversas condicionantes e dificuldades, comuns neste tipo de estruturas, e que foram sendo ultrapassadas com o planeamento atempado desses trabalhos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A deposição de resíduos sólidos urbanos (RSU) em aterros sanitários (AS) tem uma dimensão que necessita de uma atenção especial por parte da sociedade. Deste acto podem resultar situações gravosas para o meio ambiente se não forem tomadas as medidas correctas. Um dos pontos que necessita de uma particular atenção é o tratamento das águas lixiviantes dos aterros sanitários, uma vez que estas apresentam geralmente cargas altamente poluentes. O presente trabalho apresenta a estrutura de um aterro sanitário, definindo os seus princípios de funcionamento, bem como as principais características a ter em consideração para a sua concepção e construção. É ainda abordada a composição dos resíduos sólidos produzidos em Portugal de acordo com (1) e as características quantitativas e qualitativas do lixiviado produzido por um AS. São apresentados os sistemas tratamento convencionais, biológicos e físico-químicos, mais utilizados em Portugal para o tratamento de águas lixiviantes, relacionando as problemáticas e as limitações associadas a cada um deles. É ainda apresentado o tratamento combinado de águas lixiviantes com águas residuais e a recirculação de lixiviado no sistema de tratamento, assim como algumas das vantagens associadas a estas práticas. Tendo por base, uma situação real, avalia-se um caso de estudo, que visa a avaliação do funcionamento da estação de pré-tratamento das águas lixiviantes produzidas no aterro sanitário do ecoparque de Palmela, tendo em consideração o facto de este tratamento ser realizado em combinação com o tratamento de águas residuais urbanas. A avaliação do funcionamento da estação de pré-tratamento de águas lixiviantes (EPTAL) é realizada de acordo com os dados fornecidos nos relatórios elaborados pela empresa LUSÁGUA, que apresentam os valores das cargas poluentes medidos à entrada e saída da EPTAL, verificando com estes dados se os valores limite de emissão medidos à saída da EPTAL são respeitados. São ainda propostas algumas alterações baseadas em pareceres técnicos que acompanham os relatórios elaborados pela LUSÁGUA e um estudo elaborada pela ECOserviços em Fevereiro de 2010 onde se obtêm eficiências de etapas de tratamentos com base em testes laboratoriais e testes realizados na própria EPTAL.