943 resultados para X rays.
Resumo:
Preliminary studies on the long-term effects of prenatal and early postnatal irradiation on the immune response to arsonate were performed using A/J mice. Pregnant mice were irradiated (0·5 Gy, X-rays) or sham-irradiated on a single occasion during gestation (between day 5 and 18 post-conception). Alternatively, newborn mice received the same treatment between day 2 and 7 after birth. Mice were immunized with keyhole limpet haemocyanin-arsonate (KLH-Ars) in adjuvant from 2 months after birth. The levels of specific antibodies to arsonate (anti-Ars) were measured by radioimmunoassay. In addition, the Ars-related cross-reactive idiotype (CRIA) was measured by the haemagglutination technique. In the primary response the titre of anti-Ars was reduced in animals that had been irradiated between day 12 and 15 of gestation. In the second response, in contrast, they had increased levels of anti-Ars. After immunization with KLH-Ars, high levels of CRIA were observed in all groups. However, in mice irradiated 18-20 days after conception the level of CRIA was often much higher than the level of anti-Ars, indicating that a large proportion of the CRIA-positive molecules were not specific for Ars. Thus, in this particular case, some specificity of the immune response was lost after irradiation. The expression of recurrent idiotypes may be a sensitive indicator of immunological perturbations after irradiation. © 1988 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
Resumo:
We have determined resonant strengths of the KLn (2 less than or equal to n less than or equal to 5) resonances for helium-like Ti ions and (3 less than or equal to n less than or equal to 5) resonances for helium-like Fe ions. The results were obtained using the Tokyo electron beam ion trap. Characteristic X-rays from both dielectronic recombination and radiative recombination were detected as the electron beam energy was scanned through the resonances. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Dielectronic recombination (DR) has been studied in highly charged He-like Ti ions using an electron beam ion trap. X-rays emitted from radiative recombination (RR) and DR were observed as the electron beam energy was scanned through the resonances. Differential DR resonant strengths were determined by normalizing the DR x-ray intensity to the RR intensity using theoretical RR cross sections. KLn (2 less than or equal to n less than or equal to 5) resonant strengths were determined for He-like Ti ions. The differential resonant strengths were calibrated without reference to any theoretical DR calculations while the electron energy scale was derived with reference to the well-known energy for ionization of the He-like and H-like ions from the ground state. Calibration in this way facilitates a more exacting comparison between theory and experiment than has been reported previously. To facilitate this comparison, total and differential theoretical resonance strengths were calculated. These calculations were found to be in good agreement with the measured results.
Resumo:
Decay dynamics of dielectronic recombination (DR) processes of H-like titanium ions was investigated with an electron beam ion trap. In the DR of H-like ions a K-shell vacancy is available even after the decay of the doubly excited state produced by the recombination. Therefore secondary X-ray emission is possible. An observed X-ray spectrum of DR obtained in the present experiment was well reproduced theoretically by taking into account the secondary X-rays. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The two-electron QED contributions to the ground-state binding energy of Kr34+ ions have been determined in two independent experiments performed with electron beam ion traps (EBIT) in Heidelberg (HD) and Tokyo (BT, Belfast-Tokyo collaboration). X rays arising from radiative recombination (RR) of free electrons to the ground state of initially bare Kr36+ and hydrogenlike Kr35+ ions were observed as a function of the interacting electron energy. The K edge absorption by thin Eu and W foils provided fixed photon energy references used to measure the difference in binding energy Delta E-2e between the H- and He-like Kr ions (Kr35+ and Kr34+, respectively). The two values agree well, yielding a final result of Delta E-2e=641.8 +/- 1.7 eV, confirming recent results of rigorous QED calculations. This accuracy is just of the order required to access screened radiative QED contributions.
Resumo:
Aim. This paper is a presentation of a study protocol to establish the prevalence of orthopaedic problems (hip dislocation, pelvic obliquity, spinal deformity and contractures) and their impact on pain, function, participation and health in a population of children and young people with severe cerebral palsy.
Background. Cerebral palsy is the commonest cause of motor impairment in childhood and is associated with life-long disability. An estimated 30% of people with cerebral palsy have severe forms and are non-ambulant. Although the underlying neurological damage is not amenable to correction, many health services are dedicated to providing therapeutic and adaptive support to help people with the condition reach their potential.
Method. A cross-sectional survey of children and young people, aged 4–25 years with severe, non-ambulant cerebral palsy as defined using the Gross Motor Function Classification System (Levels IV and V). Study participants will be identified from a pre-existing, geographically defined case register and recruited via a healthcare professional known to them. Two assessments will be undertaken: one involving parents/carers at home and using questionnaires; the other involving the child/young person ideally in one of three settings and including X-rays if clinically indicated.
Discussion. This study will contribute to our knowledge of the history and epidemiology of orthopaedic problems in children and young people with cerebral palsy and how these problems accumulate and impact on participation, health and well-being. The study will also identify unmet need and make recommendations for good practice in relation to the orthopaedic care and management for people with severe cerebral palsy
Resumo:
The use of microbeam approaches has been a major advance in probing the relevance of bystander and adaptive responses in cell and tissue models. Our own studies at the Gray Cancer Institute have used both a charged particle microbeam, producing protons and helium ions and a soft X-ray microprobe, delivering focused carbon-K, aluminium-K and titanium-K soft X-rays. Using these techniques we have been able to build up a comprehensive picture of the underlying differences between bystander responses and direct effects in cell and tissue-like models. What is now clear is that bystander dose-response relationships, the underlying mechanisms of action and the targets involved are not the same as those observed for direct irradiation of DNA in the nucleus. Our recent studies have shown bystander responses even when radiation is deposited away from the nucleus in cytoplasmic targets. Also the interaction between bystander and adaptive responses may be a complex one related to dose, number of cells targeted and time interval.
Resumo:
Delivering sufficient dose to tumours while sparing surrounding tissue is one of the primary challenges of radiotherapy, and in common practice this is typically achieved by using highly penetrating MV photon beams and spatially shaping dose. However, there has been a recent increase in interest in the possibility of using contrast agents with high atomic number to enhance the dose deposited in tumours when used in conjunction with kV x-rays, which see a significant increase in absorption due to the heavy element's high-photoelectric cross-section at such energies. Unfortunately, the introduction of such contrast agents significantly complicates the comparison of different source types for treatment efficacy, as the dose deposited now depends very strongly on the exact composition of the spectrum, making traditional metrics such as beam quality less valuable. To address this, a 'figure of merit' is proposed, which yields a value which enables the direct comparison of different source types for tumours at different depths inside a patient. This figure of merit is evaluated for a 15 MV LINAC source and two 150 kVp sources (both of which make use of a tungsten target, one with conventional aluminium filtration, while the other uses a more aggressive thorium filter) through analytical methods as well as numerical models, considering tissue treated with a realistic concentration and uptake ratio of gold nanoparticle contrast agents (10 mg ml(-1) concentration in 'tumour' volume, 10: 1 uptake ratio). Finally, a test case of human neck phantom is considered with a similar contrast agent to compare the abstract figure to a more realistic treatment situation. Good agreement was found both between the different approaches to calculate the figure of merit, and between the figure of merit and the effectiveness in a more realistic patient scenario. Together, these observations suggest that there is the potential for contrast-enhanced kilovoltage radiation to be a useful therapeutic tool for a number of classes of tumour on dosimetric considerations alone, and they point to the need for further research in this area.
Resumo:
Recent advances in the development of 2D microstrip detectors open up new possibilities for hard x-ray spectroscopy, in particular for polarization studies. These detectors make ideal Compton polarimeters, which enable us to study precisely the polarization of hard x-rays. Here, we present recent results from measurements of Radiative Electron Capture into the K-shell of highly-charged uranium ions. The experiments were performed with a novel 2D Si(Li) Compton polarimeter at the Experimental Storage Ring at GSI. Stored and cooled beams of U91+ and U92+ ions, with kinetic energies of 43 MeV/u and 96 MeV/u respectively, were crossed with a hydrogen gasjet. The preliminary data analysis shows x-rays from the K-REC process, emitted perpendicularly to the ion beam, to be strongly linearly polarized.
Resumo:
We have measured the two-electron contribution of the ground state energy of helium-like argon ions using an electron beam ion trap (EBIT). A two-dimensional map was measured showing the intensity of x-rays from the trap passing through a krypton-filled absorption cell. The independent axes of this map were electron beam energy and x-ray energy. From this map, we deduced the two-electron contribution of the ground state of helium-like argon. This experimentally determined Value (312.4 +/- 9.5 eV) was found to be in good agreement with our calculated values (about 303.35 eV) and previous calculations of the same quantity. Based on these measurements, we have shown that a ten-day absorption spectroscopy run with a super-EBIT should be sufficient to provide a new benchmark value for the two-electron contribution to the ground state of helium-like krypton. Such a measurement would then constitute a test of quantum electrodynamics to second order.
Resumo:
Laser-driven coherent extreme-ultraviolet (XUV) sources provide pulses lasting a few hundred attoseconds(1,2), enabling real-time access to dynamic changes of the electronic structure of matter(3,4), the fastest processes outside the atomic nucleus. These pulses, however, are typically rather weak. Exploiting the ultrahigh brilliance of accelerator-based XUV sources(5) and the unique time structure of their laser-based counterparts would open intriguing opportunities in ultrafast X-ray and high-field science, extending powerful nonlinear optical and pump-probe techniques towards X-ray frequencies, and paving the way towards unequalled radiation intensities. Relativistic laser-plasma interactions have been identified as a promising approach to achieve this goal(6-13). Recent experiments confirmed that relativistically driven overdense plasmas are able to convert infrared laser light into harmonic XUV radiation with unparalleled efficiency, and demonstrated the scalability of the generation technique towards hard X-rays(14-19). Here we show that the phases of the XUV harmonics emanating from the interaction processes are synchronized, and therefore enable attosecond temporal bunching. Along with the previous findings concerning energy conversion and recent advances in high-power laser technology, our experiment demonstrates the feasibility of confining unprecedented amounts of light energy to within less than one femtosecond.
Resumo:
Laser-produced proton beams have been used to achieve ultrafast volumetric heating of carbon samples at solid density. The isochoric melting of carbon was probed by a scattering of x rays from a secondary laser-produced plasma. From the scattering signal, we have deduced the fraction of the material that was melted by the inhomogeneous heating. The results are compared to different theoretical approaches for the equation of state which suggests modifications from standard models.
Resumo:
Gold nanoparticles (GNPs) are being proposed as contrast agents to enhance X-ray imaging and radiotherapy, seeking to take advantage of the increased X-ray absorption of gold compared to soft tissue. However, there is a great discrepancy between physically predicted increases in X-ray energy deposition and experimentally observed increases in cell killing. In this work, we present the first calculations which take into account the structure of energy deposition in the nanoscale vicinity of GNPs and relate this to biological outcomes, and show for the first time good agreement with experimentally observed cell killing by the combination of X-rays and GNPs. These results are not only relevant to radiotherapy, but also have implications for applications of heavy atom nanoparticles in biological settings or where human exposure is possible because the localised energy deposition high-lighted by these results may cause complex DNA damage, leading to mutation and carcinogenesis.
Resumo:
Three-dimensional reconstruction from volumetric medical images (e.g. CT, MRI) is a well-established technology used in patient-specific modelling. However, there are many cases where only 2D (planar) images may be available, e.g. if radiation dose must be limited or if retrospective data is being used from periods when 3D data was not available. This study aims to address such cases by proposing an automated method to create 3D surface models from planar radiographs. The method consists of (i) contour extraction from the radiograph using an Active Contour (Snake) algorithm, (ii) selection of a closest matching 3D model from a library of generic models, and (iii) warping the selected generic model to improve correlation with the extracted contour.
This method proved to be fully automated, rapid and robust on a given set of radiographs. Measured mean surface distance error values were low when comparing models reconstructed from matching pairs of CT scans and planar X-rays (2.57–3.74 mm) and within ranges of similar studies. Benefits of the method are that it requires a single radiographic image to perform the surface reconstruction task and it is fully automated. Mechanical simulations of loaded bone with different levels of reconstruction accuracy showed that an error in predicted strain fields grows proportionally to the error level in geometric precision. In conclusion, models generated by the proposed technique are deemed acceptable to perform realistic patient-specific simulations when 3D data sources are unavailable.
Resumo:
Gold nanoparticles (GNPs) are of considerable interest for use as a radiosensitizer, because of their biocompatibility and their ability to increase dose deposited because of their high mass energy absorption coefficient. Their sensitizing properties have been verified experimentally, but a discrepancy between the experimental results and theoretical predictions suggests that the sensitizing effect does not depend solely on gold's superior absorption of energetic photons. This work presents the results of three sets of experiments that independently mapped out the energy dependence of the radiosensitizing effects of GNPs on plasmid DNA suspended in water. Incident photon energy was varied from 11.8 to 80 keV through the use of monochromatic synchrotron and broadband X-rays. These results depart significantly from the theoretical predictions in two ways: First, the sensitization is significantly larger than would be predicted; second, it does not vary with energy as would be predicted from energy absorption coefficients. These results clearly demonstrate that the effects of GNP-enhanced therapies cannot be predicted by considering additional dose alone and that a greater understanding of the processes involved is necessary for the development of future therapeutics.