935 resultados para Warfare, Conventional.
Resumo:
The purpose of this work is to explain the concept of cutting fluids reasonable usage through the fluid minimum quantity in grinding processes. on that purpose, the development of a new nozzle and an own and adequate methodology should be required in order to obtain good results and compare them to the conventional methods. The analysis of the grinding wheel/cutting fluid performance was accomplished from the following input parameters: flow rate variation by nozzle diameter changes (three diameters values: 3mm, 4mm and 5mm), besides the conventional round nozzle already within the machine. Integral oil and a synthetic emulsion were used as cutting fluids and a conventional grinding wheel was employed. The workpieces were made of steel VC 131, tempered and quenched with 60HRc. Thus, as the flow rate and the nozzle diameter changes, keeping steady fluid jet velocity (equal to cutting velocity), attempted to find the best machining conditions, with the purpose to obtain a decrease on the cutting fluid volume, taking into consideration the analysis of the process output variables such as cutting strength, cutting specific energy, grinding wheel wear and surface roughness. It was verified that the 3mm diameter optimized nozzle and the integral oil, in general, was the best combination among all proposed.
Resumo:
The non-ohmic and dielectric properties as well as the dependence on the microstructural features of CaCu(3)Ti(4)O(12)/CaTiO(3) ceramic composites obtained by conventional and microwave sintering were investigated. It was demonstrated that the non-ohmic and dielectric properties depend strongly on the sintering conditions. It was found that the non-linear coefficient reaches values of 65 for microwave-sintered samples and 42 for samples sintered in a conventional furnace when a current density interval of 1-10 mA cm(-2) is considered. The non-linear coefficient value of 65 is equivalent to 1500 for samples sintered in the microwave if a current interval of 5-30 mA is considered as is shortly discussed by Chung et al (2004 Nature Mater. 3 774). Due to a high non-linear coefficient and a low leakage current (90 mu A) under both processing conditions, these samples are promising for varistor applications. The conventionally sintered samples exhibit a higher relative dielectric constant at 1 kHz (2960) compared with the samples sintered in the microwave furnace (2100). At high frequencies, the dielectric constant is also larger in the samples sintered in the conventional furnace. Depending on the application, one or another synthesis methodology is recommended, that is, for varistor applications sintered in a microwave furnace and for dielectric application sintered in a conventional furnace.
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
Objective: To evaluate whether intracytoplasmic morphologically selected sperm injection (IMSI) could influence early paternal effects by observing embryo quality at day 2.Study design: The study included 30 couples with at least one of the following criteria: male factor infertility, at least 2 previous failures of implantation or previous miscarriages after IVF/ICSI. Sibling oocytes of each patient were randomly assigned to either the ICSI group or the IMSI group. For IMSI, spermatozoa were selected at 8400x magnification through an inverted microscope equipped with Nomarski differential interference contrast optics, Uplan Apo 100x oil/1.35 objective lens and variable zoom lens. For conventional ICSI, spermatozoa were selected at 400x magnification. An embryo was defined as top quality if there were four identical blastomeres on day 2 with no fragments or multinucleation of blastomeres. Data were analysed using the Wilcoxon and chi-squared tests. The significance level was set at P < 0.05. The variables were analysed in relation to the general population and the subpopulations with or without male factor.Results: A total of 331 MII oocytes (30 oocyte retrievals) were selected and injected by the ICSI (n: 172) or IMSI (n: 159) procedure. For IMSI, only spermatozoa classified as morphologically normal at high magnification were used. No differences (P > 0.05) in fertilisation rate (ICSI: 70.9%; IMSI: 70.4%), early embryo cleavage rate (ICSI: 66.9%; IMSI: 60.4%) or cleavage rate (ICSI: 99.2%; IMSI: 99.1%) were observed. on day 2, as compared to ICSI, IMSI provided a similar proportion of top quality embryos (ICSI: 57.8%; IMSI: 52.2%; P > 0.05). These results were not influenced by the presence or absence of male factor.Conclusion: In terms of embryo quality at day 2, IMSI had the same performance as conventional ICSI. However, we cannot exclude the possibility that IMSI effects occur only as a positive later paternal effect. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to evaluate the application of PCR technique for the detection of BoHV-5 in routinely formalin-fixed, paraffin-embedded brain tissues in 20 naturally infected calves affected by fatal meningoencephalitis. Brains were divided into two halves, one kept fresh for virus isolation and PCR assay, targeting the glycoprotein C gene from BoHV-5 genome. The other half brain, corresponding to posterior cortex region, was submitted to formalin fixation and embedded into paraffin blocks for microscopic evaluation and total DNA isolation. Most of the slides showed severe multifocal non-supurative encephalitis with neuronal degeneration, neurophagia, and no acidophilic intranuclear inclusions could be found in neurons and glial. The 20 fresh samples were confirmed, by virus isolation and PCR assay, as having the BoHV-5 virus and, respective glicoprotein C sequence, while 15 of 20 formalin-fixed, paraffin-embedded samples were considered positive for the same analysis. The results revealed the first description of PCR efficiency, applied to formalin-fixed, paraffin-embedded brain collected from naturally infected calves, improving the detection of BoHV-5 from archival samples in South America. (c) 2007 Published by Elsevier B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A cárie secundária representa problema de saúde pública e socioeconômico no mundo. A restauração de dentes acometidos por cárie pode criar condições favoráveis à proliferação microbiana na superfície do material restaurador ou na interface dente/restauração, criando ambiente propício para o estabelecimento de cárie secundária. O objetivo deste estudo foi avaliar a capacidade de retenção de placa bacteriana em cimentos de ionômero de vidro convencionais (Chelon-Fil e Vidrion R) e modificados por resina (Vitremer e Fuji II LC) e de resina composta híbrida (Z100), utilizada como controle. Nos testes de retenção de microrganismos, in situ, 12 voluntários utilizaram, por 7 dias, placa de Hawley contendo corpos-de-prova de todos os materiais. A seguir, os corpos-de-prova foram transferidos para tubos contendo 2,0 ml de Ringer-PRAS e os microrganismos presentes em sua superfície foram cultivados em placa com ágar-sangue e ágar Mitis Salivarius Bacitracina, os quais foram incubados, a 37ºC, em anaerobiose (90% N2, 10% CO2), por 10 e 2 dias, respectivamente. Os ionômeros modificados por resina retiveram quantidade de bactérias similar àquela mostrada pela resina testada. Os ionômeros modificados por resina também apresentaram menor número de estreptococos do grupo mutans do que a resina e os cimentos ionoméricos convencionais. Os ionômeros de vidro convencionais apresentaram menor número de estreptococos do grupo mutans que a resina, sendo que essa diferença não foi estatisticamente significativa.
Resumo:
This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.
Resumo:
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010
Resumo:
Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.
Resumo:
The cementation procedure of metal-free fixed partial dentures exhibits special characteristics about the porcelains and cementation agents, which turns the correct association between these materials necessary. Our purpose in this literature review was to point the main groups of cements associated to metal-free restoration and discuss about the advantages, disadvantages, and recommendations of each one. Our search was confined to the electronic databases PubMed and SciELO and to books about this matter. There are essentially 3 types of hard cement: conventional, resin, or a hybrid of the two. The metal-free restorations can be fixed with conventional or resin cements. The right choice of luting material is of vital importance to the longevity of dental restorative materials. Conventional cements are advantageous when good compressive straight, good film thickness, and water dissolution resistance are necessary. However, they need an ideal preparation, and they are not acid dissolution resistant. Conventional cements are indicated to porcelains that cannot be acid etched. Resin cements represent the choice to metal-free restoration cementation because they present better physical properties and aesthetic than conventional agents.
Resumo:
Background:It has been stated that mandibular overdentures are more satisfactory than conventional dentures, but problems relating to the use of retrospective ratings, lack of control group and sequential provision of treatment may compromise the findings.Objective:To establish a comparison between treatment with conventional complete dentures and implant-retained overdentures in elderly patients by conducting a literature review.Materials and methods:A search of English language peer-review literature was completed using Medline up to 2008 focusing on evidence-based research. Randomised clinical trials (RCTs) and longitudinal prospective studies were favoured in the review, using a general hierarchical classification. Articles that did not focus exclusively on the comparison of patient satisfaction between complete dentures and overdentures were excluded from further evaluation. The last search was conducted in February 2008. Key terms included quality of life, patient satisfaction, edentulism, complete denture and overdenture.Results:Among the 90 articles found in the initial search, 27 met the inclusion criteria. This included 18 RCTs and eight prospective and one cohort study. Most of the articles stated superiority of the mandibular implant-retained overdenture therapy over the conventional complete denture regarding patient satisfaction and quality of life.Conclusion:Even with implant treatment presenting higher patient satisfaction and improvement of quality of life, it was not possible to establish a direct comparison between the studies due to differences in adopted methodologies.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)