570 resultados para Valva Mitral


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the result of patients treated with IV methylprednisolone divided into three groups and compare their follow-up during the last 12 years. METHODS: Seventy children with active rheumatic carditis (76 episodes) in heart failure Class III and IV (NYHA) were studied. The diagnosis was based on modified Jones' criteria. After ruling out infections and strongyloidiasis, treatment with IV methylprednisolone bolus was started three times a week until the laboratory tests became negative. Patients were divided into 3 groups, according to the time of hospital admittance: Groups 1, 2 and 3, comprising of 40, 18 and 12 children, respectively. RESULTS: Eighteen children in Group 1 (45%) were in their 1st attack: 2 series of pulsetherapy were used in 10 (25%), 3 in 9 (23%) and 4 in 21 (52%). In Group 2, 14 cases (77%) were in their 1st attack: 2 series were used in 7 (39%), 4 in 9 (50%) and 5 in 2 (11%). The echocardiogram showed a flail mitral valve in 12 (66%) of these patients (1 death occurred after mitral valvoplasty). In Group 3, 6 patients needed 5 or more series of pulsetherapy and a flail mitral valve was present in 5 (41%). One child underwent mitral valve replacement while still in the active phase, after 8 series of pulsetherapy, and another died. The number of patients who needed 5 or more series was significantly higher in Group 3. CONCLUSION: There were variations in the presentation and evolution of the cases during these 12 year. The established pulsetherapy protocol continues to be useful to treat severe cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Aortopulmonary window (APW) is an uncommon congenital malformation. Its clinical presentation is dependent on the size of the defect and on the associated lesions. We evaluated our experience with this anomaly and compared it with 296 cases reported in the literature. METHODS: Retrospective study of 18 patients diagnosed as having APW (age range from 13 days to 31 years, 13 (72.2%) females), divided into two groups: Group A (GA): 10 patients with isolated APW, and Group B (GB): 8 patients with associated lesions. RESULTS: Heart failure occurred in 14 patients, and cyanosis in 3: 2 from GB (tetralogy of Fallot - TF, and double outlet right ventricle - DORV), and one from GA with pulmonary hypertension. In 5 patients from GA the diagnosis of mitral regurgitation was made based on a systolic murmur and LV hypertrophy on the EKG. In GB, clinical findings were determined by the associated defect. Diagnosis was established by echocardiography in 11 (61.2%) of the patients. In 3 patients, a wrong diagnosis of mitral regurgitation was made, in 1 a patent ductus arteriosus was diagnosed and in 3 others, the diagnosis of APW was masked by other important associated defects (2 cases of DORV and 1 case of TF). The diagnosis was made by catheterization in 3 (16.6%) patients, by surgery in 3 (16.6%) and by necropsy in 1 (5.5%). Corrective surgery was performed in 14 (77.7%) patients, with one immediate death and good long-term follow-up in the remaining patients. CONCLUSION: APW can be confused with other defects. Clinical findings, associated with an adequate echocardiogram can provide the information for the correct diagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Report clinical experience in surgical treatment of atrial fibrillation (AF) by Cox-maze procedure. METHODS: 61 patients underwent surgical treatment for AF. Two had primary AF and 59 AF secondary to heart disease (2 atrial septal defects, 57 mitral). Ages ranged from 20 to 74 years (mean = 49). There were 44 females (72%). The surgical technique employed was Cox 3 without cryoablation. The patients were follow-up in specific at patient clinics and underwent periodical ECG, exercise tests, echocardiogram and Holter monitoring. RESULTS: In-hospital mortality was 4.9% and late mortality 1.6%. A temporary pacemaker was used in 28 (46%) and a definitive in 7 patients (11.4%). On hospital discharge, AF remained in 17%; 63.9% had sinus rhythm, 6.9% atrial rhythm, 1.7% junctional rhythm, and 10.3% had pacemaker rhythm. In the last evaluation, AF was present in 19.5%; (70.5% sinus rhythm, 4% atrial rhythm, 2% atrial tachycardia, and 4% pacemaker rhythm). There was no report of thromboembolic episodes. Chronotropic response was considered adequate in 19%, intermediate in 29%, and inadequate in 42%. In Holter monitoring, the mean heart rate was 82±8 bpm, with a minimum of 57±7 bpm and maximum of 126±23 bpm, with supraventricular extrasystoles in 2.3±5.5% of the total heartbeats and ventricular extrasystoles in 0.8±0.5%. In the echocardiogram, the A wave was present in the left atrium in 87.5%. CONCLUSION: Maze procedure is effective and has acceptable surgical risk. Atrial or sinus rhythms remain stable with a small but remarkable frequency of atrial and ventricular arrhythmias. Left atrial contraction is present, although attenuated, as well as the chronotropic response to exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVE: To evaluate by Doppler echocardiography (DE) early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A) and 25 with CD4 cell count <500/mm³ (Group B), were analyzed. CD4 cells were counted and matched with structural data and systolic and diastolic function of the left ventricle (LV), as analyzed by DE. The results were compared with those obtained in 47 healthy individuals (Group C). RESULTS: 8% of patients in Group B had mild pericardial effusion; 31.5% showed decreased systolic function of the LV, and 12% had moderate mitral regurgitation. A wave velocity from the mitral inflow was different among the 3 groups, being higher in Group B, where the deceleration time of the E wave of the mitral inflow and the E/A ratio were significantly lower with a normal value of the isovolumic relaxation time (IVRT). CONCLUSION: HIV-positive patients with a CD4 cell count >500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³), had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Anomalous origin of the left coronary artery from the right pulmonary artery (AOLCARPA), is a rare entity that is usually associated with other defects. Of the 20 cases of AOLCARPA reported in the literature, 14 (70%) had associations. We describe four patients with AOLCARPA without associated defects, but with a peculiar intramural aortic trajectory. METHODS: Fifty-five patients with anomalous origin of the left coronary artery were operated upon at INCOR-FMUSP. Four of the patients had the anomalous origin from the right pulmonary artery (RPA) without associated defects but with intramural aortic trajectory. Clinical and laboratory examinations were analyzed, as well as surgical findings. RESULTS: All patients had congestive heart failure (CHF) and 3 also had angina pectoris. Two patients had a murmur of mitral regurgitation, signs of myocardial infarction on the ECG and cardiomegaly. The shortening fraction varied from 9% to 23%. The hemodynamic study confirmed the diagnosis of anomalous origin of the coronary artery, but the intramural trajectory and the origin from the RPA were established only at surgery. In 3 patients, the technique of side-to-side anastomosis was performed with a good outcome. One patient, who underwent end-to-side anastomosis, died 6 months after the surgery. CONCLUSION: Association with other defects usually occurs in the AOLCARPA, and the intramural aortic trajectory is difficult to clinically diagnose but easy to surgically correct.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this work was the follow-up and evaluation of valve replacement in children under 12 years of age. METHODS: Forty-four children less than 12 years old were underwent valve replacement at INCOR-HCFMUSP between January 1986 and December 1992. Forty (91%) were rheumatic, 39 (88.7%) were in functional classes II or IV, 19 (43.2%) were operated upon on an emergency basis, and 6 (13.6%) had atrial fibrillation. Biological prostheses (BP) were employed in 26 patients (59.1%), and mechanical prostheses (MP) in 18 (40.9%). Mitral valves were replaced in 30 (68.7%), aortic valves in 8 (18.2%), a tricuspid valve in 1 (2.3%), and double (aortic and mitral) valves in 5 (11.4) of the patients. RESULTS: Hospital mortality was of 4.5% (2 cases). The mean follow-up period was 5.8 years. Re-operations occurred in 63.3% of the patients with BP and in 12.5% of those with MP (p=0.002). Infectious endocarditis was present in 26.3% of the BP, but in none of the cases of MP (p=0.049). Thrombosis occurred in 2 (12.5%) and hemorrhage in one (6.5%) of the patients with a MP. Delayed mortality occurred in 5 (11.9%) of the patients over a mean period of 2.6 years; four had had BP and one had a MP (NS). Actuarial survival and re-operation-free curves after 10 years were respectively, 82.5±7.7 (SD)% and 20.6±15.9%. CONCLUSION: Patients with MP required fewer re-operation, had less infectious endocarditis and lower late mortality rates compared with patients with bioprostheses. The former, therefore, appear to be the best valve replacement for pediatric patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA). METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV) mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume) and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS). The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi) were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the epidemiology, diagnosis, clinical aspects causes and evolution of infectious endocarditis. METHODS: The patients analyzed were treated at the University Hospital of the Faculdade de Medicina of Ribeirão Preto-USP and had a diagnosis of infectious endocarditis defined by Duke's criteria, which classifies infectious endocarditis as native, prosthetic valve or that occurring in intravenous drug users. RESULTS: One hundred and eighty episodes of infectious endocarditis in 168 patients were observed. Echocardiograms in 132 (73.3%) provided a diagnosis of infectious endocarditis in 111 (84%) patients; mitral valves were affected in 55 (30.5%), tricuspid valves in 30 (16.6%) and the aortic valve in 28 (15.5%) patients. Hemocultures were performed in 148 (93.8%) episodes of IE. The most commonly isolated infectious organisms were Staphylococcus aureus in 46 (27.2%) patients and Streptococcus viridans in 27 (15.9%). Complications occurred in 116 (64.4%) patients and 73 (40.5%) of the patients died. CONCLUSION: The general profile of the observed infectious endocarditis was similar to that reported in studies performed in other countries and included users of intravenous drugs. The high degree of mortality observed is not compatible with progress in diagnosis and treatment of infectious endocarditis and is probably due to the absence of diagnostic suspicion. The high frequency of fatal cases of septicemia (45.1% of deaths) in the patients studied indicates that unnoticed cases of infectious endocarditis had only been diagnosed at necropsy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We analyzed the frequency of peripheral embolisms, the underlying heart disease,triggering factors, the sites of the emboli, and evolution of the patients. METHODS: We analyzed 29 cases of peripheral arterial embolism out of a total of 20,211 hospitalizations in a cardiology center in the city of São Paulo. The age was 51.89±18.66 years, and 15 were males. RESULTS: Embolism in the right lower limb occurred in 18 patients (62.0%),in the left lower 11(37.9%) and right upper 3 (10.3%) limbs, and in the left arm (1). Four patients had embolism in two limbs. The heart disease, mitral valvar heart disease (9 patients - 31.0%); infective endocarditis (7- 24.1%); dilated cardiomyopathy (6 - 20.6%); ischemic coronary heart disease (6 patients - 20.6%); and one patient with cor pulmonale. Atrial fibrillation was observed in 20 patients (68.9%), chronic in 12 patients (41.3% ) and acute in 8 (27.5%). All patients with mitral valvar heart disease had atrial fibrillation, chronic in 8 patients (88.8%); patients with cardiomyopathy and coronary heart disease, 4 in each group had atrial fibrillation, acute in 60% of the patients.Patients with infective endocarditis, 3 had staphylococcus and 2 Gram-negative bacteria. In the follow-up, 2 patients (6.8%) required limbs amputation, and 5 (17.2%) died due to embolism. CONCLUSION: Most of the time, embolism does not cause permanent complications. Our data highlight the importance of anticoagulation for patients acute atrial fibrillation in myocardial dysfunction and for patients with chronic atrial fibrillation in cases of mitral valvar heart disease to prevent peripheral embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess by Doppler echocardiography the structural and functional alterations of rat heart with surgical induced extensive myocardial infarction. METHODS: Five weeks after surgical ligature of the left coronary artery, 38 Wistar-EPM rats of both sexes, 10 of them with extensive infarction, undergone anatomical and functional evaluation by Doppler echocardiography and then euthanized for anatomopathological analysis. RESULTS: Echocardiography was 100% sensible and specific to anatomopathological confirmed extensive miocardial infarction. Extensive infarction lead to dilatation of left ventricle (diastolic diameter: 0.89cm vs.0.64cm; systolic: 0.72cm vs. 0.33cm) and left atrium (0.55cm vs. 0.33cm); thinning of left ventricular anterior wall (systolic: 0.14cm vs. 0.23cm, diastolic: 0.11cm vs. 0.14cm); increased mitral E/ A wave relation (6.45 vs. 1.95). Signals of increased end diastolic ventricle pressure, B point in mitral valve tracing in 62.5% and signs of pulmonary hypertension straightening of pulmonary valve (90%) and notching of pulmonary systolic flow (60%) were observed in animals with extensive infarction. CONCLUSION: Doppler echocardiography has a high sensitivity and specificity for detection of chronic extensive infarction. Extensive infarction caused dilatation of left cardiac chambers and showed in Doppler signals of increased end diastolic left ventricular pressure and pulmonary artery pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 59-year-old female patient with mitral valve prolapse and a previous history of lumbosacral spondyloarthrosis and lumbar disk hernia had an episode of infective endocarditis due to Streptococcus viridans, which evolved with peripheral embolism to the left kidney, spleen, and left iliac artery, and intraventricular cerebral hemorrhage. Her clinical manifestations were low back pain and hematuria, which were initially attributed to an osteoarticular condition. Infective endocarditis is a severe polymorphic disease with multiple clinical manifestations and it should always be included in the differential diagnosis by clinicians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the cardiovascular findings and clinical follow-up of patients with Williams-Beuren syndrome. METHODS: We studied 20 patients (11 males, mean age at diagnosis: 5.9 years old), assessed for cardiovascular abnormalities with electrocardiography and Doppler echocardiography. Fluorescence in situ hybridization (FISH) was used to confirm the diagnosis of the syndrome. RESULTS: Elastin gene locus microdeletion was detected in 17 patients (85%) (positive FISH), and in 3 patients deletion was not detected (negative FISH). Sixteen patients with a positive FISH (94%) had congenital cardiovascular disease (mean age at diagnosis: 2,3 years old). We observed isolated (2/16) supravalvular aortic stenosis and supravalvular aortic stenosis associated (11/16) with pulmonary artery stenosis (4/11); mitral valve prolapse (3/11); bicuspid aortic valve (3/11); aortic coarctation (2/11), thickened pulmonary valve (2/11); pulmonary valvular stenosis (1/11); supravalvular pulmonary stenosis (1/11); valvular aortic stenosis (1/11); fixed subaortic stenosis (1/11); pulmonary artery stenosis (2/16) associated with pulmonary valvar stenosis (1/2) and with mitral valve prolapse (1/2); and isolated mitral valve prolapse (1/16). Four patients with severe supravalvular aortic stenosis underwent surgery (mean age: 5.7 years old), and 2 patients had normal pressure gradients (mean follow-up: 8.4 years). CONCLUSION: A detailed cardiac evaluation must be performed in all patients with Williams-Beuren syndrome due to the high frequency of cardiovascular abnormalities.