932 resultados para Ultrasonic toothbrush


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To assess the behavior of the arterial wall in hypertensive patients, we developed a noninvasive ultrasonic device. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to establish compliance-pressure curves. Blood pressure, which is a co-determinant of compliance, is thus taken into account. This method allows one to compare arteries from patients with different blood pressures. Arterial compliance and distensibility were first investigated in healthy young volunteers administered either lisinopril (20 mg), atenolol (100 mg) or nitrendipine (20 mg) once a day. After 8 days of treatment, only lisinopril was found to increase arterial compliance. Subsequently, we compared arterial diameter- and distensibility-pressure curves from newly diagnosed and untreated hypertensive patients with those of matched normotensive control patients. Diameter-pressure curves did not differ significantly between the groups and distensibility was not reduced. Similar findings were later obtained in an animal model, when mechanical properties of carotid arteries were compared between spontaneously hypertensive rats and normotensive counterparts (Wistar-Kyoto rats). These results, although interesting by providing noninvasive information on the elastic response of the wall, call for further development of the technique to be able to measure arterial wall thickness. Stress-strain relationship could ultimately be established to thoroughly characterize physical properties of blood vessel walls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantitative ultrasound of bone is a promising method for bone assessment: radiation-free, portable and predictive of hip fracture. Its portability allowed us to study the relationships between ultrasonic parameters of bone with age and with non-vertebral fractures in elderly women living in 19 nursing homes. Broadband ultrasound attenuation (BUA) and speed of sound (SOS) of the calcaneus were measured (and the stiffness index calculated) in a sample of 270 institutionalized women, aged 85 +/- 7 years, using an Achilles bone densitometer (Lunar). The effects of age, history of non-vertebral and non-traumatic fractures, body mass index, triceps skinfold and arm circumference were assessed on BUA, SOS and stiffness index. Furthermore, to evaluate longitudinally the influence of aging on the ultrasound parameters of bone, 60 subjects from the same group had a second ultrasound measurement after 1 year. The cross-sectional analysis of the data on all 270 women showed a significant decrease (p < 0.001) with age in BUA, SOS and stiffness index (-0.47%, -0.06%, and -1.01% respectively per year). In the 94 women, (35%) with a history of previous non-vertebral fractures, ultrasound parameters were significantly lower (p < 0.0001) than in the 176 women with no history of fracture (-8.3% for BUA, -1.3% for SOS, -18.9% for stiffness index). In contrast, there was no significant difference in anthropometric measurements between the groups with and without previous non-vertebral fractures, although the measurements decreased significantly with age. In the longitudinal study, repeated quantitative ultrasound after 11.4 +/- 0.8 months showed no significant decrease in BUA (-1%) but a significant decrease in SOS (-0.3%, p < 0.0001) and in stiffness index (-3.6%, p < 0.0002). In conclusion, quantitative ultrasound of the calcaneus measures properties of bone which continue to decline in institutionalized elderly women, and is able to discriminate women with previous non-vertebral fractures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We performed complete eye exams on 50 eyes in 25 patients with congenital aniridia. Factors such as age, history of ocular surgery, dry eye score and aesthesiometry results correlated with the degree of aniridia-related keratopathy. Schirmer’s test I in 86.8%, Schirmer’s test II in 94.4% and TFBUT in 83.3% of cases were all normal. Corneal staining was altered in 54.2%, and conjunctival staining was altered in 45.7%. The tear ferning pattern was abnormal in 80%. Conjunctival metaplasia was present in 76.9%.Corneal endothelial cell density was normal. Ultrasonic pachymetry was higher than average in all eyes examined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mosaics have been commonly used as visual maps for undersea exploration and navigation. The position and orientation of an underwater vehicle can be calculated by integrating the apparent motion of the images which form the mosaic. A feature-based mosaicking method is proposed in this paper. The creation of the mosaic is accomplished in four stages: feature selection and matching, detection of points describing the dominant motion, homography computation and mosaic construction. In this work we demonstrate that the use of color and textures as discriminative properties of the image can improve, to a large extent, the accuracy of the constructed mosaic. The system is able to provide 3D metric information concerning the vehicle motion using the knowledge of the intrinsic parameters of the camera while integrating the measurements of an ultrasonic sensor. The experimental results of real images have been tested on the GARBI underwater vehicle

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acute effects of various vasopressor agents on the diameter of the common carotid artery were studied in halothane-anesthetized normotensive rats. The animals were infused intravenously for 60 min with equipressor doses of angiotensin II (10 ng/min), the alpha1-stimulant methoxamine (5 microg/min), lysine vasopressin (5 mU/min), or vehicle. The arterial diameter was measured by using a high-resolution ultrasonic echo-tracking device. The three vasoconstrictors increased the carotid artery diameter, but this effect was significantly more pronounced with lysine vasopressin. Even a nonpressor dose of lysine vasopressin (1 mU/min) caused a significant increase in the arterial diameter. The lysine vasopressin-induced vasodilatation could be prevented by the administration of d(CH2)5Tyr(Me)AVP (10 microg, i.v.), a selective V1-vasopressinergic receptor antagonist. These data therefore suggest that a short-term increase in blood pressure induces in rats a distention of the carotid artery. The increase in arterial diameter seems to involve an active mechanism with lysine vasopressin caused by the stimulation of V1-vasopressinergic receptors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plants naturally synthesize a variety of polymers that have been used by mankind as a source of useful biomaterials. For example, cellulose, the main constituent of plant cell wall and the most abundant polymer on earth, has been used for several thousand years as a source of fibers for various fabrics. Similarly, rubber extracted from the bark of the tree Hevea brasiliensis, has been a major source of elastomers until the development of similar synthetic polymers. In the last century, the usefulness of plant polymers as biomaterials has been expanded through the chemical modification of the natural polymers. For example, a number of plastics have been made by substituting the hydroxyl groups present on the glucose moiety of cellulose with larger groups, such as nitrate or acetate, giving rise to materials such as cellulose acetate, a clear plastic used in consumer products such as toothbrush handles and combs. Similarly, starch has been used in the manufacture of plastics by either using it in blends with synthetic polymers or as the main constituent in biodegradable plastics. The advent of transformation and expres- sion of foreign genes in plants has created the possibility of expanding the usefulness of plants to include the synthesis of a range of biomolecules. In view of the capacity of certain crops to produce a large quantity of organic raw material at low cost, such as oils and starch, it is of interest to explore the possibility of using transgenic plants as efficient vectors for the synthesis of biopolymers. Such plant based biopolymers could replace, in part, the synthetic plastics and elastomers produced from petroleum, offering the advantage of renewability and sustainability. Furthermore, being natural pro- ducts, biopolymers are usually biodegradable and can thus contribute to alleviate problems associated with the management of plastic waste. In this article, the emphasis will be on the use of transgenic plants for the synthesis of two novel classes of industrially useful polymers, namely protein based polymers made from natural or artificial genes, and polyhydroxyalkanoates, a family of bacterial poly- esters having the properties of biodegradable plastics and elastomers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new plastic self-expanding Smartcanula (Smartcanula LLC, Lausanne, Switzerland) is designed for central insertion and prevention of caval collapse. The objective of our work is to assess the influence of the new design on atrial chatter. Caval collapse over the entire caval axis, right atrial, hepatic, renal vein, and iliac vein is realized in drainage tubes with holes at 5 cm distance intervals. Smartcanulas with various lengths (26 cm [= right atrial], 34 cm [= hepatic], 43 cm [= renal], and 53 cm [= iliac]) versus two-stage cannulas are compared. Pressure drop (ΔP) is measured using Millar pressure-transducers. Flow rate (Q) is measured using an ultrasonic flow meter. Cannula resistance is defined as the ΔP/Q ratio. Data display and recording are controlled using LabView virtual instruments. At an 88 cm height differential, Q values are 8.69 and 6.8 l/min, and ΔP/Q ratios are 0.63 and 1.28 for the 26-cm Smartcanula and the reference cannula, respectively. The 34-cm Smartcanula showed 8.89 l/min and 0.6 ΔP/Q ratio vs. 7.59 l/min and 0.9 for the control cannula (P < 0.05). The 43-cm and 53-cm Smartcanulas showed Q values of 9.04 and 8.81 l/min, respectively, and ΔP/Q2 ratio of 0.6. The Smartcanula outperforms the two-stage cannula, and direct cannula insertion without guide wire is effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquest projecte s'ha dut a terme amb el Grup de visió per computador del departamentd'Arquitectura i Tecnologia de Computadors (ATC) de la Universitat de Girona. Està enfocat a l'anàlisi d'imatges mèdiques, en concret s'analitzaran imatges de pròstata en relació a desenvolupaments que s'estan realitzant en el grup de visió esmentat. Els objectius fixats per aquest projecte són desenvolupar dos mòduls de processamentm d'imatges els quals afrontaran dos blocs important en el tractament d'imatges, aquests dos mòduls seran un pre-processat d'imatges, que constarà de tres filtres i un bloc de segmentació per tal de cercar la pròstata dintre de les imatges a tractar. En el projecte es treballarà amb el llenguatge de programació C++, concretament amb unes llibreries que es denominen ITK (Insight Toolkit ) i són open source enfocades al tractament d'imatges mèdiques. A part d'aquesta eina s'utilitzaran d'altres com les Qt que és una biblioteca d'eines per crear entorns gràfics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new high-precision ultrasonic device was developed to determine noninvasively arterial compliance as a function of blood pressure. Because of the nonlinear elastic properties of arterial walls, measurements of compliance can be appropriately compared only if obtained over a range of pressures. This apparatus was used to evaluate in a double-blind, parallel fashion the effect of three different antihypertensive drugs and of a placebo on radial artery compliance. Thirty-two normotensive volunteers were randomly allocated to an 8-day, once-a-day oral treatment with either a placebo, 100 mg atenolol, 20 mg nitrendipine, or 20 mg lisinopril. Blood pressure, heart rate, radial artery diameter, and arterial compliance were measured immediately before as well as 6 hours after dosing on the first and last days of the study. On the eighth day of administration, within 6 hours after dosing, lisinopril induced an acute increase in radial artery diameter, from 2.99 +/- 0.06 to 3.28 +/- 0.09 mm (mean +/- SEM, p less than 0.01). The compliance-pressure curve was shifted upward on day 1 (p less than 0.01) as well as on day 8 (p less than 0.05). None of the other drugs induced any significant modification of these parameters. Arterial compliance has a strong nonlinear dependency on intra-arterial pressure and therefore has to be defined as a function of pressure. Antihypertensive drugs acting by different mechanisms may have different effects on the mechanical properties of large arteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To use diffusion-tensor (DT) magnetic resonance (MR) imaging in patients with essential tremor who were treated with transcranial MR imaging-guided focused ultrasound lesion inducement to identify the structural connectivity of the ventralis intermedius nucleus of the thalamus and determine how DT imaging changes correlated with tremor changes after lesion inducement. MATERIALS AND METHODS: With institutional review board approval, and with prospective informed consent, 15 patients with medication-refractory essential tremor were enrolled in a HIPAA-compliant pilot study and were treated with transcranial MR imaging-guided focused ultrasound surgery targeting the ventralis intermedius nucleus of the thalamus contralateral to their dominant hand. Fourteen patients were ultimately included. DT MR imaging studies at 3.0 T were performed preoperatively and 24 hours, 1 week, 1 month, and 3 months after the procedure. Fractional anisotropy (FA) maps were calculated from the DT imaging data sets for all time points in all patients. Voxels where FA consistently decreased over time were identified, and FA change in these voxels was correlated with clinical changes in tremor over the same period by using Pearson correlation. RESULTS: Ipsilateral brain structures that showed prespecified negative correlation values of FA over time of -0.5 or less included the pre- and postcentral subcortical white matter in the hand knob area; the region of the corticospinal tract in the centrum semiovale, in the posterior limb of the internal capsule, and in the cerebral peduncle; the thalamus; the region of the red nucleus; the location of the central tegmental tract; and the region of the inferior olive. The contralateral middle cerebellar peduncle and bilateral portions of the superior vermis also showed persistent decrease in FA over time. There was strong correlation between decrease in FA and clinical improvement in hand tremor 3 months after lesion inducement (P < .001). CONCLUSION: DT MR imaging after MR imaging-guided focused ultrasound thalamotomy depicts changes in specific brain structures. The magnitude of the DT imaging changes after thalamic lesion inducement correlates with the degree of clinical improvement in essential tremor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have measured the adiabatic elastic constants of two Cu-Al-Ni martensitic alloys using ultrasonic methods and we have compared the results to recent neutron-scattering experiments. It is shown that the elastic behavior of Cu-Al-Ni alloys follows the same trends exhibited by other Cu-based alloys; in particular, the TA2 long-wavelength acoustic modes are softer than all other modes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental data from ultrasonic and inelastic neutron scattering measurements are analyzed for different families of Cu-based shape-memory alloys. It is shown that the transition occurs at a value, independent of composition and alloy family, of the ratio between the elastic constants associated with the two shears necessary to accomplish the lattice distortion from the bcc to the close-packed structure. The zone boundary frequency of the TA2[110] branch evaluated at the transition point (TM), weakly depends, for each family, on composition. A linear relationship between this frequency and the inverse of the elastic constant C', both quantities evaluated at TM, has been found, in agreement with the prediction of a Landau model proposed for martensitic transformations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have measured the changes in the ultrasonic wave velocity, induced by the application of uniaxial stresses in a Cu-Al-Ni single crystal. From these measurements, the complete set of third-order elastic constants has been obtained. The comparison of results for Cu-Al-Ni with available data for other Cu-based alloys has shown that all these alloys exhibit similar anharmonic behavior. By using the measured elastic constants in a Landau expansion for elastic phase transitions, we have been able to give an estimation of the value of a fourth-order elastic constants combination. The experiments have also shown that the application of a stress in the [001] direction, reduces the material resistance to a (110)[110] shear and thus favors the martensitic transition.