958 resultados para Tube wells
Resumo:
Traditional methods of measuring sound absorption coefficient and sound transmission loss of a material are time consuming. To overcome this limitation, normal incidence sound absorption and transmission loss measurement technique was developed. Unfortunately the equipment required for this task is equally expensive. Hence efforts are taken to develop a cost-effective equipment for measuring normal incidence sound absorption coefficient and transmission loss. An impedance tube capable of measure absorption coefficient and transmission loss is designed and built under a budget of $1500 for educational institutes. A background study is performed to gain knowledge and understanding of the normal incidence measurements technique. Based on the literature review, parameters involved such as tube material, source and microphone properties, sample holders, etc. are discussed in depth. Based on these parameters, design options are generated to meet the cost and functionality targets pre-assigned. After selection of materials and components, an impedance tube is built and tested using three fibrous absorption materials for absorption and a barrier for transmission loss performance. These measured results then compared with those obtained with the help of industry recognized Brüel & Kjær impedance tube. The results show performances are comparable, hence validation the new built tube.
Resumo:
Manual drilling is a popular solution for programs seeking to increase drinking water supply in rural Madagascar. Lightweight, affordable and locally produced drilling equipment allows rapid implementation where access is problematic and funds are limited. This report will look at the practical implications of using manual drilling as a one-step solution to potable water in rural development. The main benefits of using these techniques are time and cost savings. The author uses his experience managing a drilling campaign in northeastern Madagascar to explore the benefits and limitations of one particular drilling methodology – BushProof’s Madrill technique. Just under 200 wells were drilled using this method in the course of one fiscal year (September 2011-September 2012). The paper explores what compromises must be considered in the quest for cost-effective boreholes and whether everybody - from the implementers to project managers to clients and lawmakers - are in agreement about the consequences of such compromises. The paper also discusses water quality issues encountered when drilling in shallow aquifers.
Resumo:
To analyze the detection of endoleaks with low-tube-voltage computed tomographic (CT) angiography.
Resumo:
RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.
Ambient vertical flow in long-screen wells: a case study in the Fontainebleau Sands Aquifer (France)
Resumo:
Plant cell expansion is controlled by a fine-tuned balance between intracellular turgor pressure, cell wall loosening and cell wall biosynthesis. To understand these processes, it is important to gain in-depth knowledge of cell wall mechanics. Pollen tubes are tip-growing cells that provide an ideal system to study mechanical properties at the single cell level. With the available approaches it was not easy to measure important mechanical parameters of pollen tubes, such as the elasticity of the cell wall. We used a cellular force microscope (CFM) to measure the apparent stiffness of lily pollen tubes. In combination with a mechanical model based on the finite element method (FEM), this allowed us to calculate turgor pressure and cell wall elasticity, which we found to be around 0.3 MPa and 20–90 MPa, respectively. Furthermore, and in contrast to previous reports, we showed that the difference in stiffness between the pollen tube tip and the shank can be explained solely by the geometry of the pollen tube. CFM, in combination with an FEM-based model, provides a powerful method to evaluate important mechanical parameters of single, growing cells. Our findings indicate that the cell wall of growing pollen tubes has mechanical properties similar to rubber. This suggests that a fully turgid pollen tube is a relatively stiff, yet flexible cell that can react very quickly to obstacles or attractants by adjusting the direction of growth on its way through the female transmitting tissue.
Resumo:
The Hamamatsu R11410 photomultiplier, a tube of 3" diameter and with a very low intrinsic radioactivity, is an interesting light sensor candidate for future experiments using liquid xenon (LXe) as target for direct dark matter searches. We have performed several experiments with the R11410 with the goal of testing its performance in environments similar to a dark matter detector setup. In particular, we examined its long-term behavior and stability in LXe and its response in various electric field configurations.
Resumo:
Neural tube defects (NTDs) are malformations of the developing brain and spinal cord; the most common are anencephaly and spina bifida. Evidence from many populations suggests that 50% of NTDs can be prevented through daily consumption of folic acid. A recent study has reported that folic acid may not protect populations of Mexican descent. This finding has serious implications for women living along the US-Mexico border. Not only is risk high in these Mexican American women compared with other US women; they also differ markedly in supplemental folic acid and dietary folate consumption, and in NTD-related risks (e.g., obesity, diabetes). This case-control study investigated whether folic acid supplements and dietary folate reduces NTDs in Mexican Americans. Cases included liveborn, stillborn, electively and spontaneously aborted NTD-affected fetuses and infants occurring in the 14-county Texas-Mexico border. Controls were randomly selected from unaffected live births, frequency matched to cases by hospital and year. An in-person interview of 110 case and 113 control mothers solicited data on folic acid supplements, dietary folate, and other covariates. Consumption of folic acid-containing vitamins before conception was only 5% for both case and control women. Taking vitamins the trimester before conception had no apparent effect, after adjusting for covariates [odds ratio (OR) = 1.0, 95% confidence interval (CI) = 0.3–3.4]. Combining folate from vitamins and diet showed a 20% risk reduction for women consuming at least 400 μg of folate daily [OR = 0.8, 95% CI = 0.5–1.5]; however, this estimate is statistically indistinguishable from the null. Although consistent with an inherent ineffectiveness of supplemental folic acid, that so few women consumed multivitamins during the critical time severely limited the assessment of folic acid in this population. A reduced folate response in Mexican descent women may be due to a genetic heterogeneity for metabolizing folate. Alternatively, folate intakes may be insufficient to overcome other underlying risk factors. In conclusion, determining whether folic acid reduces NTD risk in Mexican American women requires further study in populations with higher folic acid exposures. Meanwhile, we should pursue all recommended prevention strategies to reduce risk, including motivating Mexican American women of childbearing age to take folic acid routinely. ^