977 resultados para Transcatheter aortic valve replacement
Resumo:
Background Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or “inoperable” patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. Objective The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. Methods All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Results Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% ± 13.9% vs STS 6.7% ± 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES ≥15%, 16% had an STS ≥10%, and 40% had an LES ≥20% or STS ≥10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Conclusions Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making.
Resumo:
The ATS 3f Enable® Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant procedures.
Resumo:
BACKGROUND: The arterial switch operation (ASO) is currently the treatment of choice in neonates with transposition of the great arteries (TGA). The outcome in childhood is encouraging but only limited data for long-term outcome into adulthood exist. METHODS AND RESULTS: We studied 145 adult patients (age>16, median 25years) with ASO followed at our institution. Three patients died in adulthood (mortality 2.4/1000-patient-years). Most patients were asymptomatic and had normal left ventricular function. Coronary lesions requiring interventions were rare (3 patients) and in most patients related to previous surgery. There were no acute coronary syndromes. Aortic root dilatation was frequent (56% patients) but rarely significant (>45mm in 3 patients, maximal-diameter 49mm) and appeared not to be progressive. There were no acute aortic events and no patient required elective aortic root surgery. Progressive neo-aortic-valve dysfunction was not observed in our cohort and only 1 patient required neo-aortic-valve replacement. Many patients (42.1%), however, had significant residual lesions or required reintervention in adulthood. Right ventricular outflow tract lesions or dysfunction of the neo-pulmonary-valve were frequent and 8 patients (6%) required neo-pulmonary-valve replacement. Cardiac interventions during childhood (OR 3.0, 95% CI 1.7-5.4, P<0.0001) were strong predictors of outcome (cardiac intervention/significant residual lesion/death) in adulthood. CONCLUSIONS: Adult patients with previous ASO remain free of acute coronary or aortic complications and have low mortality. However, a large proportion of patients require re-interventions or present with significant right sided lesions. Life-long cardiac follow-up is, therefore, warranted. Periodic noninvasive surveillance for coronary complications appears to be safe in adult ASO patients.
Acute hyponatremia after cardioplegia by histidine-tryptophane-ketoglutarate - a retrospective study
Resumo:
Background Hyponatremia is the most common electrolyte disorder in hospitalized patients and is known to be associated with increased mortality. The administration of antegrade single-shot, up to two liters, histidine-tryptophane-ketoglutarate (HTK) solution for adequate electromechanical cardiac arrest and myocardial preservation during minimally invasive aortic valve replacement (MIAVR) is a standard procedure. We aimed to determine the impact of HTK infusion on electrolyte and acid–base balance. Methods In this retrospective analysis we reviewed data on patient characteristics, type of surgery, arterial blood gas analysis during surgery and intra-/postoperative laboratory results of patients receiving surgery for MIAVR at a large tertiary care university hospital. Results A total of 25 patients were included in the study. All patients were normonatremic at start of surgery. All patients developed hyponatremia after administration of HTK solution with a significant drop of serum sodium of 15 mmol/L (p < 0.01). Measured osmolality did not change during all times of surgery compared to start of surgery (p = 0.28 – p = 0.79), indicating isotonic hyponatremia. After administration of HTK solution pH fell significantly due to development of metabolic acidosis. Conclusions Acute hyponatremia during cardioplegia with HTK solution is isotonic and should probably not be corrected without presence of hypotonicity as confirmed by measurement of serum osmolality.
Resumo:
OBJECTIVE: Assessment of postoperative quality of life in patients over 80 years after cardiac surgery including coronary artery bypass grafting (CABG), aortic valve replacement (AVR) and combined procedures. METHODS: Quality of life of n=136 patients over 80 years at operation (82.3+/-2.1 years), undergoing isolated CABG in 61 patients (45%), isolated AVR in 34 patients (25%) and a combination of CABG and AVR in 41 patients (30%) between January 1999 and December 2003 was reviewed. Preoperatively 66.2% presented in NYHA-class III/IV or CCS-class III/IV. Mean ejection fraction (EF) was 59.5%+/-14.0 (range 25-90%). Quality of life assessment was performed via a Seattle Angina Questionnaire. Follow-up was 100% complete for a total of 890 days (69-1853 days). RESULTS: Five-year survival was 70% for the CABG group, 75% for the AVR group and 65% for the CABG/AVR group. Quality of life was remarkable in all of the three groups after surgery. Overall 97 patients (81%) were not or little disabled in their daily activity. One hundred and twelve patients (93%) were free or considerably less symptomatic. Seventy-eight patients or 65% reported to be very satisfied with their current quality of life and 112 patients (93%) felt very reassured to have continuous full access to medical treatment despite of their advanced age. CONCLUSIONS: A remarkable quality of life and important improvement in the functional status after cardiac surgery in patients over 80 paired with a satisfactory medium-term survival justify early intervention for heart disease in this age group. Therefore, referral practice for patients over 80 years for heart surgery should be handled liberally.
Resumo:
OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access.
Resumo:
BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.
Resumo:
The Ross operation remains a controversially discussed procedure when performed in the full root technique because concern exists regarding late dilatation of the pulmonary autograft and regurgitation of the neo-aortic valve. In 2008, we published our short-term experience when using external reinforcement of the autograft, which was inserted into a prosthetic Dacron graft. This detail was thought to prevent neoaortic root dilatation. Since 2006, 22 adult patients have undergone a Ross procedure using this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 15), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 10 patients. Prior balloon valvuloplasty had been performed in seven patients. No early or late deaths occurred in this small series. One patient required aortic valve replacement early postoperatively, but freedom from late reoperation is 100% in the 21 remaining patients. Echocardiography confirmed the absence of more than trivial aortic insufficiency in 15 patients after a mean of 70 months (range, 14 to 108 months). No autograft dilatation was observed during follow-up and all patients are in New York Heart Association Class I. Autograft reinforcement is a simple and reproducible technical adjunct that may be especially useful in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement. The mid- to long-term results are encouraging because no late aortic root enlargement has been observed and the autograft valve is well functioning in all cases.
Resumo:
BACKGROUND Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) region can be inaccessible for ablation because of epicardial fat or overlying coronary arteries. OBJECTIVE We describe surgical cryoablation of this type of VA. METHODS From March 2009 to 2014, 190 consecutive patients with VAs originating from the LVOT underwent ablation at our institution. Four patients (2%) underwent surgical cryoablation for highly symptomatic VAs after failing catheter ablation. RESULTS In all patients, endocardial or percutaneous epicardial mapping was consistent with origin in the LVOT. In 2 patients, the points of earliest activation during VAs were marked with a bipolar pacing lead in the overlying cardiac vein for guidance during surgery. Surgical cryoablation was successful in 3 of the 4 patients. The fourth patient subsequently had successful endocardial catheter ablation. During a mean follow-up of 22 ± 16 months (range 4-42 months), all patients showed abolition of or marked reduction in symptomatic VA. However, 1 patient subsequently required percutaneous intervention to the left anterior descending coronary artery; another developed progressive left ventricular systolic dysfunction caused by nonischemic cardiomyopathy; and a third patient underwent permanent pacemaker implantation because of complete atrioventricular block after concomitant aortic valve replacement. CONCLUSION Surgical cryoablation is an option for highly symptomatic drug-resistant VAs emanating from the LVOT region. Despite extensive preoperative mapping, the procedure is not effective for all patients, and coronary injury is a risk.
Resumo:
La stenosi valvolare aortica è la più frequente patologia valvolare cardiaca nei paesi sviluppati come diretta conseguenza dell’aumentata aspettativa di vita. In Europa si stima che il numero di soggetti sintomatici per stenosi valvolare aortica aumenterà da 1.3 milioni nel 2025 a 2.1 milioni in 2050. Di conseguenza la stenosi aortica ha e avrà un forte impatto sulla salute pubblica e sui costi che ne determina, poiché spesso associata a un declino funzionale dei pazienti ed aumentata incidenza di ospedalizzazione. D’altra parte è noto che la stenosi valvolare aortica severa non trattata si associa a prognosi infausta con una sopravvivenza del 50% a 2 anni dall’insorgenza dei sintomi e del 20% a 5 anni. Ad oggi non esiste una terapia medica efficace per la stenosi valvolare aortica in quanto andando a costituire un’ostruzione meccanica, resta di competenza del cardiochirurgo o del cardiologo interventista. La sostituzione valvolare aortica, sia essa chirurgica o percutanea, resta pertanto il solo trattamento definitivo per la stenosi valvolare aortica. Nel tempo il rischio operatorio è estremamente diminuito e i vantaggi in termini di miglioramento della qualità di vita sono evidenti. Questo progetto di ricerca prevede pertanto un’analisi delle più recenti tecnologie per il trattamento chirurgico della stenosi valvolare aortica a partire dalla tipologia di approccio chirurgico, se mini-invasivo o tradizionale, fino all’utilizzo delle più recenti protesi biologiche sutureless studiandone i vantaggi, svantaggi e risultati. Prima ancora, tuttavia, saranno analizzati i meccanismi di biologia molecolare alla base dell’eziologia della stenosi aortica al fine di poter identificare precocemente i pazienti, di prevedere l’andamento della patologia e forse, in futuro, anche di ipotizzare una terapia farmacologica mirata.
Resumo:
La sostituzione valvolare aortica (TAVI) è un trattamento che negli ultimi anni ha dimostrato essere una valida opzione per la cura di pazienti affetti da grave stenosi aortica. Il suo vantaggio è quello di essere un’alternativa alla procedura chirurgica (surgical aortic valve replacement-SAVR), la quale può esporre il paziente a numerosi rischi. Dal primo prototipo di valvola espandibile a palloncino e poi con la successiva introduzione della tipologia di valvola autoespandibile, nel corso degli anni gli impianti valvolari aortici hanno subito una notevole evoluzione per quanto concerne il design e le nuove tipologie di valvola, rendendo la TAVI sempre più competitiva e dimostrando numerose potenzialità. La sua efficacia si osserva soprattutto in pazienti ad alto rischio di operabilità, ma grazie alla collaborazione di un preparato team multidisciplinare questa procedura ha avuto la possibilità di estendersi anche su pazienti esposti a minor rischio, dimostrando risultati promettenti per il futuro. Verranno illustrati due studi clinici che dimostreranno l’efficacia della TAVI e soprattutto la sua non inferiorità rispetto all’intervento chirurgico, confermandosi un trattamento innovativo e con un notevole potenziale per la cura della stenosi aortica.
Resumo:
We report the case of implantation of metallic mitral and aortic valve prostheses 6 months earlier, with subsequent multiple embolic episodes. The anatomicopathological examination of the thrombus of the third embolic episode was compatible with Aspergillus sp, which was treated with amphotericin B, followed by oral itraconazole. On the fourth embolism, vegetations were visualized in the ascending aorta on echocardiography and resonance imaging, and the patient underwent replacement of the aortic segment by a Haemashield tube and exploration of the aortic prosthesis, which was preserved, because no signs of endocarditis were found. Four months later, the patient died due to cardiogenic shock secondary to acute myocardial infarction caused by probable coronary embolism and partial dysfunction of the aortic prosthesis.
Resumo:
Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
Resumo:
Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.
Resumo:
Objectives: To evaluate clinical and echocardiographic variables that could be used to predict outcomes in patients with asymptomatic severe aortic valve stenosis. Management of asymptomatic severe aortic stenosis is controversial. Because prophylactic surgery may be protective, independent predictors of events that could justify early surgery have been sought. Methods: Outpatients (n= 133; mean [+/- SD] age, 66.2 +/- 13.6 years) with isolated severe asymptomatic aortic stenosis but normal left ventricular function and no previous myocardial infarction were followed up prospectively at a tertiary care hospital. Interventions: We use a ""wait-for-events"" strategy. Clinical and echocardiographic variables were analyzed. Results: Nineteen patients developed angina; 40, dyspnea; 5, syncope; and 7, sudden death during a mean follow-up period of 3.30 +/- 1.87 years. Event-free survival was 90.2 +/- 2.6% at 1 year, 73.4 +/-.9% at 2 years, 70.7 +/- 4.3% at 3 years, 57.8 +/- 4.7% at 4 years, 40.3 +/- 5.0% at 5 years, and 33.3 +/- 5.2% at 6 years. The mean follow-up period until sudden death (1.32 +/- 1.11 years) was shorter than that for dyspnea (2.44 +/- 1.84 years), syncope (2.87 +/- 1.26 years) and angina (3.03 +/- 1.68 years). Cox regression analysis disclosed only reduced but within normal limits ejection fraction as independent predictor of total events. Conclusions: Management on ""wait-for-events"" strategy is generally safe. Progressive left ventricular ejection fraction reduction even within normal limits identified patients at high risk for events in whom valve replacement surgery should be considered. (c) 2007 Elsevier Ireland Ltd. All rights reserved.