A series of short-isora-fiber-reinforced natural rubber composites were prepared by the incorporation of fibers of different lengths (6, 10, and 14 mm) at 15 phr loading and at different concentrations (10, 20, 30, and 40 phr) with a 10 mm fiber length. Mixes were also prepared with 10 mm long fibers treated with a 5% NaOH solution. The vulcanization parameters, processability, and stress-strain properties of these composites were analyzed. Properties such as tensile strength, tear strength, and tensile modulus were found to be at maximum for composites containing longitudinally oriented fibers 10 mm in length. Mixes containing fiber loadings of 30 phr with bonding agent (resorcinol-formaldehyde [RF] resin) showed mechanical properties superior to all other composites. Scanning electron microscopy (SEM) studies were carried out to investigate the fiber surface morphology, fiber pullout, and fiber-rubber interface. SEM studies showed that the bonding between the fiber and rubber was improved with treated fibers and with the use of bonding agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental caries persists to be the most predominant oral disease in spite of remarkable progress made during the past half- century to reduce its prevalence. Early diagnosis of carious lesions is an important factor in the prevention and management of dental caries. Conventional procedures for caries detection involve visual-tactile and radiographic examination, which is considered as “gold standard”. These techniques are subjective and are unable to detect the lesions until they are well advanced and involve about one-third of the thickness of enamel. Therefore, all these factors necessitate the need for the development of new techniques for early diagnosis of carious lesions. Researchers have been trying to develop various instruments based on optical spectroscopic techniques for detection of dental caries during the last two decades. These optical spectroscopic techniques facilitate noninvasive and real-time tissue characterization with reduced radiation exposure to patient, thereby improving the management of dental caries. Nonetheless, a costeffective optical system with adequate sensitivity and specificity for clinical use is still not realized and development of such a system is a challenging task.Two key techniques based on the optical properties of dental hard tissues are discussed in this current thesis, namely laser-induced fluorescence (LIF) and diffuse reflectance (DR) spectroscopy for detection of tooth caries and demineralization. The work described in this thesis is mainly of applied nature, focusing on the analysis of data from in vitro tooth samples and extending these results to diagnose dental caries in a clinical environment. The work mainly aims to improve and contribute to the contemporary research on fluorescence and diffuse reflectance for discriminating different stages of carious lesions. Towards this, a portable and compact laser-induced fluorescence and reflectance spectroscopic system (LIFRS) was developed for point monitoring of fluorescence and diffuse reflectance spectra from tooth samples. The LIFRS system uses either a 337 nm nitrogen laser or a 404 nm diode laser for the excitation of tooth autofluorescence and a white light source (tungsten halogen lamp) for measuring diffuse reflectance.Extensive in vitro studies were carried out on extracted tooth samples to test the applicability of LIFRS system for detecting dental caries, before being tested in a clinical environment. Both LIF and DR studies were performed for diagnosis of dental caries, but special emphasis was given for early detection and also to discriminate between different stages of carious lesions. Further the potential of LIFRS system in detecting demineralization and remineralization were also assessed.In the clinical trial on 105 patients, fluorescence reference standard (FRS) criteria was developed based on LIF spectral ratios (F500/F635 and F500/F680) to discriminate different stages of caries and for early detection of dental caries. The FRS ratio scatter plots developed showed better sensitivity and specificity as compared to clinical and radiographic examination, and the results were validated with the blindtests. Moreover, the LIF spectra were analyzed by curve-fitting using Gaussian spectral functions and the derived curve-fitted parameters such as peak position, Gaussian curve area, amplitude and width were found to be useful for distinguishing different stages of caries. In DR studies, a novel method was established based on DR ratios (R500/R700, R600/R700 and R650/R700) to detect dental caries with improved accuracy. Further the diagnostic accuracy of LIFRS system was evaluated in terms of sensitivity, specificity and area under the ROC curve. On the basis of these results, the LIFRS system was found useful as a valuable adjunct to the clinicians for detecting carious lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we study the evolution of the kinetic features of the martensitic transition in a Cu-Al-Mn single crystal under thermal cycling. The use of several experimental techniques including optical microscopy, calorimetry, and acoustic emission, has enabled us to perform an analysis at multiple scales. In particular, we have focused on the analysis of avalanche events (associated with the nucleation and growth of martensitic domains), which occur during the transition. There are significant differences between the kinetics at large and small length scales. On the one hand, at small length scales, small avalanche events tend to sum to give new larger events in subsequent loops. On the other hand, at large length scales the large domains tend to split into smaller ones on thermal cycling. We suggest that such different behavior is the necessary ingredient that leads the system to the final critical state corresponding to a power-law distribution of avalanches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The length – weight relationship and relative condition factor of the shovel nose catfish, Arius subrostratus (Valenciennes, 1840) from Champakkara backwater were studied by examination of 392 specimens collected during June to September 2008. These fishes ranged from 6 to 29 cm in total length and 5.6 to 218 g in weight. The relation between the total length and weight of Arius subrostratus is described as Log W = -1.530+2.6224 log L for males, Log W = - 2.131 + 3.0914 log L for females and Log W = - 1.742 + 2.8067 log L for sexes combined. The mean relative condition factor (Kn) values ranged from 0.75 to 1.07 for males, 0.944 to 1.407 for females and 0.96 to 1.196 for combined sexes. The length-weight relationship and relative condition factor showed that the well-being of A. subrostratus is good. The morphometric measurements of various body parts and meristic counts were recorded. The morphometric measurements were found to be non-linear and there is no significant difference observed between the two sexes. From the present investigation, the fin formula can be written as D: I, 7; P: I, 12; A: 17 – 20; C: 26 – 32. There is no change in meristic counts with the increase in body length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Available information on abundance of myctophids and their utilisation indicate that there is excellent scope for development of myctophid fisheries in Indian Ocean. Most of the conventional fish stocks have reached a state of full exploitation or over-exploitation. Hence there is need to locate new and conventional fishery resources in order to fill in the supply-demand gap, in the face of increasing demand for fish. Information on length-weight relationship, age and growth, spawning season, fecundity and age at maturity and information on bycatch discards are required for sustainable utilization of myctophid resource in the Indian Ocean

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently Itatani et al. [Nature 432, 876 (2004)] introduced the new concept of molecular orbital tomography, where high harmonic generation (HHG) is used to image electronic wave functions. We describe an alternative reconstruction form, using momentum instead of dipole matrix elements for the electron recombination step in HHG. We show that using this velocity-form reconstruction, one obtains better results than using the original length-form reconstruction. We provide numerical evidence for our claim that one has to resort to extremely short pulses to perform the reconstruction for an orbital with arbitrary symmetry. The numerical evidence is based on the exact solution of the time-dependent Schrödinger equation for 2D model systems to simulate the experiment. Furthermore we show that in the case of cylindrically symmetric orbitals, such as the N2 orbital that was reconstructed in the original work, one can obtain the full 3D wave function and not only a 2D projection of it. Vor kurzem führten Itatani et al. [Nature 432, 876 (2004)] das Konzept der Molelkülorbital-Tomographie ein. Hierbei wird die Erzeugung hoher Harmonischer verwendet, um Bilder von elektronischen Wellenfunktionen zu gewinnen. Wir beschreiben eine alternative Form der Rekonstruktion, die auf Impuls- statt Dipol-Matrixelementen für den Rekombinationsschritt bei der Erzeugung der Harmonischen basiert. Wir zeigen, dass diese "Geschwindigkeitsform" der Rekonstruktion bessere Ergebnisse als die ursprüngliche "Längenform" liefert. Wir zeigen numerische Beweise für unsere Behauptung, dass man zu extrem kurzen Laserpulsen gehen muss, um Orbitale mit beliebiger Symmetrie zu rekonstruieren. Diese Ergebnisse basieren auf der exakten Lösung der zeitabhängigen Schrödingergleichung für 2D-Modellsysteme. Wir zeigen ferner, dass für zylindersymmetrische Orbitale wie das N2-Orbital, welches in der oben zitierten Arbeit rekonstruiert wurde, das volle 3D-Orbital rekonstruiert werden kann, nicht nur seine 2D-Projektion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exam questions and solutions in LaTex

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exam questions and solutions in PDF

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper compares conventional auditory brainstem response tests (ABRs) and Maximum Length Sequence auditory brainstem response tests (MLS ABRs). The results found that the faster MLS ABRs could prove an accurate screening tool for auditory sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews speechreading and the effect of sentence length and linguistic complexity on deaf children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyethylenimine (PEI) is an efficient nonviral gene delivery vector because of its high buffering capacity and DNA condensation ability. In our study, the amino groups on the polymeric backbone were acylated using acetic or propionic anhydride to alter the protonation behaviour and the hydrophilic/hydrophobic balance of the polymer. The concentration of acylated primary amines was determined using trinitrobenzene sulphonic acid assay. Results showed that our modified polymers had lower buffering capacities in solutions compared to PEI. The polymers were complexed with plasmid encoding enhanced green fluorescent protein at three different ratios (1:1, 1:2 and 1:10 w/w DNA to polymer) to form polyplexes and their toxicities and transfection efficiencies were evaluated in HEK 293 cells. Acylation reduced the number of primary amines on the polymer and the surface charge, improving haemocompatibility and reducing cytotoxicity. The reduction in the concentration of amino groups helped to optimise DNA compaction and facilitated polyplex dissociation in the cell, which increased transfection efficiency of the modified polymers compared to the parent polymer. Polymers with buffering capacities greater than 50% and less than 80% relative to PEI, showed higher transfection efficiencies than PEI. The propionic anhydride modified polymers had appropriate interactions with DNA which provided both DNA compaction and polyplex dissociation. These systems interacted better with the cell membrane because of their slightly higher lipophilicity and formed polyplexes which were less cytotoxic than polyplexes of acetic anhydride modified polymers. Among the vectors tested, 1:0.3 mol/mol PEI:propionic anhydride in a 1:2 w/w DNA:polymer composition provided the best transfection system with improved transfection efficiency and reduced cytotoxicity.