Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper makes a comparative study of two Soft Single Switched Quadratic Boost Converters (SSS1 and SSS2) focused on Maximum Power Point Tracking (MPPT) of a PV array using Perturb and Observe (P&O) algorithm. The proposed converters maintain the static gain characteristics and dynamics of the original converter with the advantage of considerably reducing the switching losses and Electromagnetic Interference (EMI). It is displayed the input voltage Quadratic Boost converter modeling; qualitative and quantitative analysis of soft switching converters, defining the operation principles, main waveforms, time intervals and the state variables in each operation steps, phase planes of resonant elements, static voltage gain expressions, analysis of voltage and current efforts in semiconductors and the operational curves at 200 W to 800 W. There are presented project of PI, PID and PID + Notch compensators for MPPT closed-loop system and resonant elements design. In order to analyze the operation of a complete photovoltaic system connected to the grid, it was chosen to simulate a three-phase inverter using the P-Q control theory of three-phase instantaneous power. Finally, the simulation results and experimental with the necessary comparative analysis of the proposed converters will be presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An optimal day-ahead scheduling method (ODSM) for the integrated urban energy system (IUES) is introduced, which considers the reconfigurable capability of an electric distribution network. The hourly topology of a distribution network, a natural gas network, the energy centers including the combined heat and power (CHP) units, different energy conversion devices and demand responsive loads (DRLs), are optimized to minimize the day-ahead operation cost of the IUES. The hourly reconfigurable capability of the electric distribution network utilizing remotely controlled switches (RCSs) is explored and discussed. The operational constraints from the unbalanced three-phase electric distribution network, the natural gas network, and the energy centers are considered. The interactions between the electric distribution network and the natural gas network take place through conversion of energy among different energy vectors in the energy centers. An energy conversion analysis model for the energy center was developed based on the energy hub model. A hybrid optimization method based on genetic algorithm (GA) and a nonlinear interior point method (IPM) is utilized to solve the ODSM model. Numerical studies demonstrate that the proposed ODSM is able to provide the IUES with an effective and economical day-ahead scheduling scheme and reduce the operational cost of the IUES.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper develops an integrated optimal power flow (OPF) tool for distribution networks in two spatial scales. In the local scale, the distribution network, the natural gas network, and the heat system are coordinated as a microgrid. In the urban scale, the impact of natural gas network is considered as constraints for the distribution network operation. The proposed approach incorporates unbalance three-phase electrical systems, natural gas systems, and combined cooling, heating, and power systems. The interactions among the above three energy systems are described by energy hub model combined with components capacity constraints. In order to efficiently accommodate the nonlinear constraint optimization problem, particle swarm optimization algorithm is employed to set the control variables in the OPF problem. Numerical studies indicate that by using the OPF method, the distribution network can be economically operated. Also, the tie-line power can be effectively managed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Software Architecture is a high level description of a software intensive system that enables architects to have a better intellectual control over the complete system. It is also used as a communication vehicle among the various system stakeholders. Variability in software-intensive systems is the ability of a software artefact (e.g., a system, subsystem, or component) to be extended, customised, or configured for deployment in a specific context. Although variability in software architecture is recognised as a challenge in multiple domains, there has been no formal consensus on how variability should be captured or represented. In this research, we addressed the problem of representing variability in software architecture through a three phase approach. First, we examined existing literature using the Systematic Literature Review (SLR) methodology, which helped us identify the gaps and challenges within the current body of knowledge. Equipped with the findings from the SLR, a set of design principles have been formulated that are used to introduce variability management capabilities to an existing Architecture Description Language (ADL). The chosen ADL was developed within our research group (ALI) and to which we have had complete access. Finally, we evaluated the new version of the ADL produced using two distinct case studies: one from the Information Systems domain, an Asset Management System (AMS); and another from the embedded systems domain, a Wheel Brake System (WBS). This thesis presents the main findings from the three phases of the research work, including a comprehensive study of the state-of-the-art; the complete specification of an ADL that is focused on managing variability; and the lessons learnt from the evaluation work of two distinct real-life case studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introdução: Ao longo do tempo o Tratamento Endodôntico Não Cirúrgico tem sido das áreas da Medicina Dentária que mais tem evoluído. Todos os passos do tratamento têm sido revistos de forma a aumentar a taxa de sucesso. O controlo microbiológico é crucial para que o tratamento seja um sucesso a curto, médio e longo prazo. A assepsia deve ser mantida em todas as fases deste tratamento para que este seja um sucesso. Objetivo: Ao longo do meu percurso académico pude concluir que a fase da descontaminação dos cones, aquando a obturação (fase final do Tratamento Endodôntico Não Cirúrgico) era desvalorizada, o que me levou a efetuar uma revisão bibliográfica de modo a poder melhorar os meus conhecimentos e técnica. Material e Métodos: Para a elaboração deste trabalho foi realizada uma pesquisa bibliográfica recorrendo aos seguintes motores de busca: B-on, PubMed, Scielo e ScienceDirect, com as seguintes palavras-chave: “decontamination in endodontics”;” disinfection in endodontics”; “root canal irrigants”; “endodontics microbiology”; “Candida albicans“; “Enterococcus faecalis”; “sodium hypochlorite ”; “alcohol”; “contamination during Obturation”; “clorohexidine”; “filling materials endodontics”; “termoplastic gutta-percha”; “obturation material”; “Mineral Trioxide Aggregate”; “resilon”; “resin cement”; “resin material for root canal obturation”; “resin sealer”; “root canal”; “root canal sealing”; “root canal filling materials”; “condensation in endodontics”; “lateral condensation”; “gutta-percha”; “microlekeage”; “system B”; “fluid filtration model”;“dye penetration”. Como critério de inclusão estabeleceu-se que os artigos deveriam ser em Português, Inglês ou Espanhol e publicados entre 1995 e 2015. Dos resultados apresentados foram utilizados 110 artigos, pesquisados entre Maio de 2015 e 20 de Outubro de 2015. Foram ainda consultados livros de referência nestes mesmos locais. Conclusão: a presença de bactérias e os seus subprodutos no sistema tridimensional de canais está diretamente implicado com o insucesso do Tratamento Endodôntico. A descontaminação dos cones de guta-percha, é, portanto, um processo importante no Tratamento Endodôntico pois impede que os cones sejam colocados nos canais radiculares, estando contaminados por microorganismos que inviabilizam o tratamento efetuado. A submersão dos cones durante um minuto em clorohexidina a 2% ou hipoclorito a 5,25% está indicado e comprovado como um processo eficiente de desinfeção dos cones.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A ocratoxina A é um composto formado a partir do metabolismo secundário de fungos dos gêneros Aspergillus e Penicillium. Uma vez que a presença dessa micotoxina nos alimentos causa sérios danos à saúde humana e animal, surge o interesse pelo desenvolvimento de métodos que visem a redução dos seus níveis em diferentes matrizes. Diversos processos de descontaminação têm sido propostos, sendo que os métodos de redução biológica tem recebido destaque. Esses métodos consistem na aplicação de micro-organismos ou de suas enzimas, o que gera a biotransformação ou degradação da toxina produzindo metabólitos com menor ou nenhuma toxicidade. Diante disso, o objetivo geral do trabalho foi avaliar o efeito da peroxidase na redução dos níveis de ocratoxina A. As enzimas peroxidases testadas foram a comercial e a obtida do farelo de arroz. Para a extração enzimática foram utilizadas as frações granulométricas do farelo de arroz de 48 a 100 mesh, sendo estas frações caracterizadas quimicamente. A peroxidase foi extraída do farelo de arroz em tampão 10 mM pH 5,0 e purificada por partição trifásica, obtendo 77,1% de recuperação e 9,2 para o fator de purificação. O método utilizado para a extração da ocratoxina A do sistema aquoso foi por partição líquido-líquido utilizando como solvente o clorofórmio, sendo esse método validado segundo os parâmetros de linearidade (0,1 a 20 ng mL-1), coeficientes de correlação (0,9997) e de determinação (0,9994), e limites de detecção (0,02) e quantificação (0,03). A afinidade entre as peroxidases e a ocratoxina A foi verificada segundo os parâmetros de KM e Vmáx, resultando em 0,00027 mM e 0,000015 mM min-1, respectivamente, para a peroxidase comercial, e 0,0065 mM e 0,000031 mM min-1 para a obtida do farelo de arroz. Com relação aos percentuais de redução de ocratoxina A, foram avaliadas 3 proporções enzima:substrato (1:10, 1:5 e 8:1 para a comercial e 1:10, 1:5 e a com atividade de 0,063 U mL-1 para a do farelo), sendo que as proporções que forneceram maior redução foi a de 8:1 para a enzima comercial (0,063 U mL-1) e a correspondente a 0,063 U mL-1 para a enzima obtida do farelo. Os percentuais de redução de ocratoxina A foram de 59% para a peroxidase comercial em 300 min e 41% para a peroxidase do farelo de arroz em 1440 min. O efeito de adsorção da ocratoxina A pela enzima peroxidase foi descartado uma vez que foi realizada a sua hidrólise com a enzima pepsina e verificado um percentual de 2,7% de adsorção, demonstrando que a redução foi por ação enzimática. A enzima obtida de farelo de arroz com atividade de 0,063 U mL-1 foi aplicada em suco de uva tinto e branco. Observou-se que para o primeiro não houve redução significativa, enquanto que para o segundo a redução foi de 17%. Neste trabalho, então, foi possível verificar a capacidade de redução dos níveis da ocratoxina A pela enzima peroxidase, tanto em sistema aquoso como no suco de uva integral branco.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Eletrotécnica Ramo de Automação e Eletrónica Industrial

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Power generation from alternative sources is at present the subject of numerous research and development in science and industry. Wind energy stands out in this scenario as one of the most prominent alternative in the generation of electricity, by its numerous advantages. In research works, computer reproduction and experimental behavior of a wind turbine are very suitable tools for the development and study of new technologies and the use of wind potential of a given region. These tools generally are desired to include simulation of mechanical and electrical parameters that directly affect the energy conversion. This work presents the energy conversion process in wind systems for power generation, in order to develop a tool for wind turbine emulation testing experimental, using LabVIEW® software. The purpose of this tool is to emulate the torque developed in an axis wind turbine. The physical setup consists of a three phase induction motor and a permanent magnet synchronous generator, which are evaluated under different wind speed conditions. This tool has the objective to be flexible to other laboratory arrangements, and can be used in other wind power generation structures in real time. A modeling of the wind power system is presented, from the turbine to the electrical generator. A simulation tool is developed using Matlab/Simulink® with the purpose to pre-validate the experiment setup. Finally, the design is implemented in a laboratory setup.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Distributed generation systems must fulfill standards specifications of current harmonics injected to the grid. In order to satisfy these grid requirements, passive filters are connected between inverter and grid. This work compares the characteristic response of the traditional inductive (L) filter with the inductive-capacitive-inductive (LCL) filter. It is shown that increasing the inductance L leads to a good ripple current suppression around the inverter switching frequency. The LCL filter provides better harmonic attenuation and reduces the filter size. The main drawback is the LCL filter impedance, which is characterized by a typical resonance peak, which must be damped to avoid instability. Passive or active techniques can be used to damp the LCL resonance. To address this issue, this dissertation presents a comparison of current control for PV grid-tied inverters with L filter and LCL filter and also discuss the use of active and passive damping for different regions of resonance frequency. From the mathematical models, a design methodology of the controllers was developed and the dynamic behavior of the system operating in closed loop was investigated. To validate the studies developed during this work, experimental results are presented using a three-phase 5kW experimental platform. The main components and their functions are discussed in this work. Experimental results are given to support the theoretical analysis and to illustrate the performance of grid-connected PV inverter system. It is shown that the resonant frequency of the system, and sampling frequency can be associated in order to calculate a critical frequency, below which is essential to perform the damping of the LCL filter. Also, the experimental results show that the active buffer per virtual resistor, although with a simple development, is effective to damp the resonance of the LCL filter and allow the system to operate stable within predetermined parameters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The forensic toxicologist faces challenges in the detection of drugs and poisons in biological samples due to transformations which occur both during life and after death. For example, changes can result from drug metabolism during life or from the use of formalin solution for post mortem embalming purposes. The former requires the identification of drug metabolites and the latter the identification of chemical reaction products in order to know which substances had been administered. The work described in this thesis was aimed at providing ways of tackling these challenges and was divided into two parts. Part 1 investigated the use of in vitro drug metabolism by human liver microsomes (HLM) to obtain information on drug metabolites and Part 2 investigated the chemical reactions of drugs and a carbamate pesticide with formalin solution and formalin-blood. The initial aim of part I was to develop an in vitro metabolism method using HLM, based on a literature review of previous studies of this type. MDMA was chosen as a model compound to develop the HLM method because its metabolism was known and standards of its metabolites were commercially available. In addition, a sensitive and selective method was developed for the identification and quantitation of hydrophilic phase I drug metabolites using LC/MS/MS with a conventional reverse-phase (C18) column. In order to obtain suitable retention factors for polar drug metabolites on this column, acetyl derivatives were evaluated for converting the metabolites to more lipophilic compounds and an optimal separation system was developed. Acetate derivatives were found to be stable in the HPLC mobile phase and to provide good chromatographic separation of the target analytes. In vitro metabolism of MDMA and, subsequently, of other drugs involved incubation of 4 µg drug substance in pH 7.4 buffer with an NADPH generating system (NGS) at 37oC for 90 min with addition of more NGS after 30 min. The reaction was stopped at 90 min by the addition of acetonitrile before extraction of the metabolites. Acetate derivatives of MDMA metabolites were identified by LC/MS/MS using multiple reaction monitoring (MRM). Three phase I metabolites (both major and minor metabolites) of MDMA were detected in HLM samples. 3,4-dihydroxy-methamphetamine and 4-hydroxy-3-methoxymethamphetamine were found to be major metabolites of MDMA whereas 3,4-methylenedioxyamphetamine was found to be a minor metabolite. Subsequently, ten MDMA positive urines were analysed to compare the metabolite patterns with those produced by HLM. An LC/MS method for MDMA and its metabolites in urine samples was developed and validated. The method demonstrated good linearity, accuracy and precision and insignificant matrix effects, with limits of quantitation of 0.025 µg/ml. Moreover, derivatives of MDMA and its metabolites were quantified in all 10 positive human urine samples. The urine metabolite pattern was found to be similar to that from HLM. The second aim of Part 1 was to use the HLM system to study the metabolism of some new psychoactive substances, whose misuse worldwide has necessitated the development of analytical methods for these drugs in biological specimens. Methylone and butylone were selected as representative cathinones and para-methoxyamphetamine (PMA) was chosen as a representative ring-substituted amphetamine, because of the involvement of these drugs in recent drug-related deaths, because of a relative lack of information on their metabolism, and because reference standards of their metabolites were not commercially available. An LC/MS/MS method for the analysis of methylone, butylone, PMA and their metabolites was developed. Three phase I metabolites of methylone and butylone were detected in HLM samples. Ketone reduction to β-OH metabolites and demethylenation to dihydroxy-metabolites were found to be major phase I metabolic pathways of butylone and methylone whereas N-demethylation to nor-methylone and nor-butylone were found to be minor pathways. Also, demethylation to para-hydroxyamphetamine was found to be a major phase I metabolic pathway of PMA whereas β-hydroxylation to β-OH-PMA was found to be a minor pathway. Formaldehyde is used for embalming, to reduce decomposition and preserve cadavers, especially in tropical countries such as Thailand. Drugs present in the body can be exposed to formaldehyde resulting in decreasing concentrations of the original compounds and production of new substances. The aim of part II of the study was to evaluate the in vitro reactions of formaldehyde with selected drug groups including amphetamines (amphetamine, methamphetamine and MDMA), benzodiazepines (alprazolam and diazepam), opiates (morphine, hydromorphone, codeine and hydrocodone) and with a carbamate insecticide (carbosulfan). The study would identify degradation products to serve as markers for the parent compounds when these were no longer detectable. Drugs standards were spiked in 10% formalin solution and 10% formalin blood. Water and whole blood without formalin were used for controls. Samples were analysed by LC/MS/MS at different times from the start, over periods of up to 30 days. Amphetamine, methamphetamine and MDMA were found to rapidly convert to methamphetamine, DMA and MDDMA respectively, in both formalin solution and formalin blood, confirming the Eschweiler-Clarke reaction between amine-containing compounds and formaldehyde. Alprazolam was found to be unstable whereas diazepam was found to be stable in both formalin solution and water. Both were found to hydrolyse in formalin solution and to give open-ring alprazolam and open-ring diazepam. Other alprazolam conversion products attached to paraformaldehyde were detected in both formalin solution and formalin blood. Morphine and codeine were found to be more stable than hydromorphone and hydrocodone in formalin solution. Conversion products of hydromorphone and hydrocodone attached to paraformaldehyde were tentatively identified in formalin solution. Moreover, hydrocodone and hydromorphone rapidly decreased within 24 h in formalin blood and could not be detected after 7 days. Carbosulfan was found to be unstable in formalin solution and was rapidly hydrolysed within 24 h, whereas in water it was stable up to 48 h. Carbofuran was the major degradation product, plus smaller amounts of other products, 3-ketocarbofuran and 3-hydrocarbofuran. By contrast, carbosulfan slowly hydrolysed in formalin-blood and was still detected after 15 days. It was concluded that HLM provide a useful tool for human drug metabolism studies when ethical considerations preclude their controlled administration to humans. The use of chemical derivatisation for hydrophilic compounds such as polar drug metabolites for analysis by LC/MS/MS with a conventional C18 column is effective and inexpensive, and suitable for routine use in the identification and quantitation of drugs and their metabolites. The detection of parent drugs and their metabolites or conversion and decomposition products is potentially very useful for the interpretation of cases in forensic toxicology, especially when the original compounds cannot be observed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Harmonic distortion on voltages and currents increases with the increased penetration of Plug-in Electric Vehicle (PEV) loads in distribution systems. Wind Generators (WGs), which are source of harmonic currents, have some common harmonic profiles with PEVs. Thus, WGs can be utilized in careful ways to subside the effect of PEVs on harmonic distortion. This work studies the impact of PEVs on harmonic distortions and integration of WGs to reduce it. A decoupled harmonic three-phase unbalanced distribution system model is developed in OpenDSS, where PEVs and WGs are represented by harmonic current loads and sources respectively. The developed model is first used to solve harmonic power flow on IEEE 34-bus distribution system with low, moderate, and high penetration of PEVs, and its impact on current/voltage Total Harmonic Distortions (THDs) is studied. This study shows that the voltage and current THDs could be increased upto 9.5% and 50% respectively, in case of distribution systems with high PEV penetration and these THD values are significantly larger than the limits prescribed by the IEEE standards. Next, carefully sized WGs are selected at different locations in the 34-bus distribution system to demonstrate reduction in the current/voltage THDs. In this work, a framework is also developed to find optimal size of WGs to reduce THDs below prescribed operational limits in distribution circuits with PEV loads. The optimization framework is implemented in MATLAB using Genetic Algorithm, which is interfaced with the harmonic power flow model developed in OpenDSS. The developed framework is used to find optimal size of WGs on the 34-bus distribution system with low, moderate, and high penetration of PEVs, with an objective to reduce voltage/current THD deviations throughout the distribution circuits. With the optimal size of WGs in distribution systems with PEV loads, the current and voltage THDs are reduced below 5% and 7% respectively, which are within the limits prescribed by IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Modern electric machine drives, particularly three phase permanent magnet machine drive systems represent an indispensable part of high power density products. Such products include; hybrid electric vehicles, large propulsion systems, and automation products. Reliability and cost of these products are directly related to the reliability and cost of these systems. The compatibility of the electric machine and its drive system for optimal cost and operation has been a large challenge in industrial applications. The main objective of this dissertation is to find a design and control scheme for the best compromise between the reliability and optimality of the electric machine-drive system. The effort presented here is motivated by the need to find new techniques to connect the design and control of electric machines and drive systems. A highly accurate and computationally efficient modeling process was developed to monitor the magnetic, thermal, and electrical aspects of the electric machine in its operational environments. The modeling process was also utilized in the design process in form finite element based optimization process. It was also used in hardware in the loop finite element based optimization process. The modeling process was later employed in the design of a very accurate and highly efficient physics-based customized observers that are required for the fault diagnosis as well the sensorless rotor position estimation. Two test setups with different ratings and topologies were numerically and experimentally tested to verify the effectiveness of the proposed techniques. The modeling process was also employed in the real-time demagnetization control of the machine. Various real-time scenarios were successfully verified. It was shown that this process gives the potential to optimally redefine the assumptions in sizing the permanent magnets of the machine and DC bus voltage of the drive for the worst operating conditions. The mathematical development and stability criteria of the physics-based modeling of the machine, design optimization, and the physics-based fault diagnosis and the physics-based sensorless technique are described in detail. To investigate the performance of the developed design test-bed, software and hardware setups were constructed first. Several topologies of the permanent magnet machine were optimized inside the optimization test-bed. To investigate the performance of the developed sensorless control, a test-bed including a 0.25 (kW) surface mounted permanent magnet synchronous machine example was created. The verification of the proposed technique in a range from medium to very low speed, effectively show the intelligent design capability of the proposed system. Additionally, to investigate the performance of the developed fault diagnosis system, a test-bed including a 0.8 (kW) surface mounted permanent magnet synchronous machine example with trapezoidal back electromotive force was created. The results verify the use of the proposed technique under dynamic eccentricity, DC bus voltage variations, and harmonic loading condition make the system an ideal case for propulsion systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Renewable or sustainable energy (SE) sources have attracted the attention of many countries because the power generated is environmentally friendly, and the sources are not subject to the instability of price and availability. This dissertation presents new trends in the DC-AC converters (inverters) used in renewable energy sources, particularly for photovoltaic (PV) energy systems. A review of the existing technologies is performed for both single-phase and three-phase systems, and the pros and cons of the best candidates are investigated. In many modern energy conversion systems, a DC voltage, which is provided from a SE source or energy storage device, must be boosted and converted to an AC voltage with a fixed amplitude and frequency. A novel switching pattern based on the concept of the conventional space-vector pulse-width-modulated (SVPWM) technique is developed for single-stage, boost-inverters using the topology of current source inverters (CSI). The six main switching states, and two zeros, with three switches conducting at any given instant in conventional SVPWM techniques are modified herein into three charging states and six discharging states with only two switches conducting at any given instant. The charging states are necessary in order to boost the DC input voltage. It is demonstrated that the CSI topology in conjunction with the developed switching pattern is capable of providing the required residential AC voltage from a low DC voltage of one PV panel at its rated power for both linear and nonlinear loads. In a micro-grid, the active and reactive power control and consequently voltage regulation is one of the main requirements. Therefore, the capability of the single-stage boost-inverter in controlling the active power and providing the reactive power is investigated. It is demonstrated that the injected active and reactive power can be independently controlled through two modulation indices introduced in the proposed switching algorithm. The system is capable of injecting a desirable level of reactive power, while the maximum power point tracking (MPPT) dictates the desirable active power. The developed switching pattern is experimentally verified through a laboratory scaled three-phase 200W boost-inverter for both grid-connected and stand-alone cases and the results are presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Hydroelectric systems are well-known for large scale power generation. However, there are virtually no studies on energy harvesting with these systems to produce tens or hundreds of milliwatts. The goal of this work was to study which design parameters from large-scale systems can be applied to small-scale systems. Two types of hydro turbines were evaluated. The first one was a Pelton turbine which is suitable for high heads and low flow rates. The second one was a propeller turbine used for low heads and high flow rates. Several turbine geometries and nozzle diameters were tested for the Pelton system. For the propeller, a three-bladed turbine was tested for different heads and draft tubes. The mechanical power provided by these turbines was measured to evaluate the range of efficiencies of these systems. A small three-phase generator was developed for coupling with the turbines in order to evaluate the generated electric power. Selected turbines were used to test battery charging with hydroelectric systems and a comparison between several efficiencies of the systems was made. Keywords