973 resultados para Thickness swelling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manner in which 90? ferroelectric-ferroelastic domains respond to changes in temperature has been mapped in BaTiO3 single crystals using atomic force microscopy. Domain periodicity remains unaltered until approximately 2 ? C below the Curie temperature (TC ), whereupon domains coarsened dramatically. This behavior was successfully rationalized by considering the temperature dependence of the parameters associated with standard models of ferroelastic domain formation. However, while successful in describing the expected radical increase in equilibrium period with temperature, the model did not predict the unusual mechanism by which domain coarsening occurred; this was not continuous at a local level but instead involved discrete domain annihilation events. Subsequent insights from a combination of free energy analysis for the system and further experimental data from an analogous situation, in which domain period increases with increasing crystal thickness, suggested that domain annihilation is inevitable whenever a component of the relevant gradient that affects domain period is orientated parallel to the domain walls. Consistent with this thesis, we note that, for the observations presented herein, the thermal gradient possessed a significant component parallel to the domain walls. We suggest that domain annihilation is a general feature of domain structures in gradient fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin films of titanium dioxide and titanium dioxide with incorporated gold and silver nanoparticles were deposited onto glass microscope slides, steel and titanium foil coupons by two sol-gel dip-coating methods. The film's photocatalytic activity and ability to evolve oxygen in a sacrificial solution were assessed. It was found that photocatalytic activity increased with film thickness (from 50 to 500 nm thick samples) for the photocatalytic degradation of methylene blue in solution and resazurin redox dye in an intelligent ink dye deposited on the surface. Contrastingly, an optimum film thickness of similar to 200 nm for both composite and pure films of titanium dioxide was found for water oxidation, using persulfate (S2O82-) as a sacrificial electron acceptor. The nanoparticle composite films showed significantly higher activity in oxygen evolution studies compared with plain TiO2 films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty eight films of titanium dioxide of varying thickness were synthesised by using atmospheric pressure chemical vapour deposition (CVD) of titanium(IV) chloride and ethyl acetate onto glass and titanium substrates. Fixed reaction conditions at a substrate temperature of 660 degrees C were used for all depositions, with varying deposition times of 5-60 seconds used to control the thickness of the samples. A sacrificial electron acceptor system composed of alkaline sodium persulfate was used to determine the rate at which these films could photo-oxidise water in the presence of 365 nm light. The results of this work showed that the optimum thickness for CVD films on titanium substrates for the purposes of water oxidation was approximate to 200 nm, and that a platinum coating on the reverse of such samples leads to a five-fold increase in the observed rate of water oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of poly(ethylene glycol) (PEG) plasticiser content and molecular weight on the physicochemical properties of films cast from aqueous blends of poly(methyl vinyl ether-co-maleic acid) was investigated using thermal analysis, swelling studies, scanning electron microscopy (SEM) and attenuated total reflectance (ATR)-Fourier transform infrared (FTIR) spectroscopy. FTIR spectroscopy revealed a shift of the C{double bond, long}O peak from 1708 to 1731 cm, indicating that an esterification reaction had occurred upon heating, thus producing crosslinked films. Higher molecular weight PEGs (10,000 and 1000 Da, respectively), having greater chain length, producing hydrogel networks with lower crosslink densities and higher average molecular weight between two consecutive crosslinks. Accordingly, such materials exhibited higher swelling rates. Hydrogels crosslinked with a low molecular weight PEG (PEG 200) showed rigid networks with high crosslink densities and, therefore, lower swelling rates. Polymer:plasticizer ratio alteration did not yield any discernable patterns, regardless of the method of analysis. The polymer-water interaction parameter (?) increased with increases in the crosslink density. SEM studies showed that porosity of the crosslinked films increased with increasing PEG MW, confirming what had been observed with swelling studies and thermal analysis, that the crosslink density must be decreased as the M of the crosslinker is increased. Hydrogels containing PMVE/MA/PEG 10,000 could be used for rapid delivery of drug, due to their low crosslink density. Moderately crosslinked PMVE/MA/PEG 1000 hydrogels or highly crosslinked PMVE/MA/PEG 200 systems could then be used in controlling the drug delivery rates. We are currently evaluating these systems, both alone and in combination, for use in sustained release drug delivery devices. © 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We characterized hydrogels, prepared from aqueous blends of poly(methyl vinyl ether-co-maleic acid) (PMVE/MA) and poly(ethylene glycol) (PEG 10,000 Daltons) containing a pore-forming agent (sodium bicarbonate, NaHCO ). Increase in NaHCO content increased the equilibrium water content (EWC) and average molecular weight between crosslinks (M ) of hydrogels. For example, the %EWC was 731, 860, 1109, and 7536% and the M was 8.26, 31.64, 30.04, and 3010.00 × 10 g/mol for hydrogels prepared from aqueous blends containing 0, 1, 2, and 5% w/w of NaHCO , respectively. Increase in NaHCO content also resulted in increased permeation of insulin. After 24 h, percentage permeation was 0.94, 3.68, and 25.71% across hydrogel membranes prepared from aqueous blends containing 0, 2, and 5% w/w of NaHCO , respectively. Hydrogels containing the pore-forming agent were fabricated into microneedles (MNs) for transdermal drug delivery applications by integrating the MNs with insulin-loaded patches. It was observed that the mean amount of insulin permeating across neonatal porcine skin in vitro was 20.62% and 52.48% from hydrogel MNs prepared from aqueous blends containing 0 and 5% w/w of NaHCO . We believe that these pore-forming hydrogels are likely to prove extremely useful for applications in transdermal drug delivery of biomolecules. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A full-thickness macular hole (FTMH) is a common retinal condition associated with impaired vision. Randomised controlled trials (RCTs) have demonstrated that surgery, by means of pars plana vitrectomy and post-operative intraocular tamponade with gas, is effective for stage 2, 3 and 4 FTMH. Internal limiting membrane (ILM) peeling has been introduced as an additional surgical manoeuvre to increase the success of the surgery; i.e. increase rates of hole closure and visual improvement. However, little robust evidence exists supporting the superiority of ILM peeling compared with no-peeling techniques. The purpose of FILMS (Full-thickness macular hole and Internal Limiting Membrane peeling Study) is to determine whether ILM peeling improves the visual function, the anatomical closure of FTMH, and the quality of life of patients affected by this disorder, and the cost-effectiveness of the surgery. Methods/Design: Patients with stage 2-3 idiopathic FTMH of less or equal than 18 months duration (based on symptoms reported by the participant) and with a visual acuity = 20/40 in the study eye will be enrolled in this FILMS from eight sites across the UK and Ireland. Participants will be randomised to receive combined cataract surgery (phacoemulsification and intraocular lens implantation) and pars plana vitrectomy with postoperative intraocular tamponade with gas, with or without ILM peeling. The primary outcome is distance visual acuity at 6 months. Secondary outcomes include distance visual acuity at 3 and 24 months, near visual acuity at 3, 6, and 24 months, contrast sensitivity at 6 months, reading speed at 6 months, anatomical closure of the macular hole at each time point (1, 3, 6, and 24 months), health related quality of life (HRQOL) at six months, costs to the health service and the participant, incremental costs per quality adjusted life year (QALY) and adverse events. Discussion: FILMS will provide high quality evidence onthe role of ILM peeling in FTMH surgery. © 2008 Lois et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To determine whether internal limiting membrane (ILM) peeling is effective and cost effective compared with no peeling in patients with idiopathic stage 2 or 3 full-thickness maculay hole (FTMH). METHODS. This was a pragmatic multicenter randomized controlled trial. Eligible participants from nine centers were randomized to ILM peeling or no peeling (1:1 ratio) in addition to phacovitrectomy, including detachment and removal of the posterior hyaloid and gas tamponade. The primary outcome was distance visual acuity (VA) at 6 months after surgery. Secondary outcomes included hole closure, distance VA at other time points, near VA, contrast sensitivity, reading speed, reoperations, complications, resource use, and participant-reported health status, visual function, and costs. RESULTS. Of 141 participants randomized in nine centers, 127 (90%) completed the 6-month follow-up. Nonstatistically significant differences in distance visual acuity at 6 months were found between groups (mean difference, 4.8; 95% confidence interval [CI], -0.3 to 9.8; P = 0.063). There was a significantly higher rate of hole closure in the ILM-peel group (56 [84%] vs. 31 [48%]) at 1 month (odds ratio [OR], 6.23; 95% CI, 2.64-14.73; P <0.001) with fewer reoperations (8 [12%] vs. 31 [48%]) performed by 6 months (OR, 0.14; 95% CI, 0.05- 0.34; P <0.001). Peeling the ILM is likely to be cost effective. CONCLUSIONS. There was no evidence of a difference in distance VA after the ILM peeling and no-ILM peeling techniques. An important benefit in favor of no ILM peeling was ruled out. Given the higher anatomic closure and lower reoperation rates in the ILM-peel group, ILM peeling seems to be the treatment of choice for idiopathic stage 2 to 3 FTMH. © 2011 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To determine whether internal limiting membrane (ILM) peeling is cost-effective compared with no peeling for patients with an idiopathic stage 2 or 3 full-thickness macular hole. Methods: A cost-effectiveness analysis was performed alongside a randomised controlled trial. 141 participants were randomly allocated to receive macular-hole surgery, with either ILM peeling or no peeling. Health-service resource use, costs and quality of life were calculated for each participant. The incremental cost per quality-adjusted life year (QALY) gained was calculated at 6 months. Results: At 6 months, the total costs were on average higher (£424, 95% CI -182 to 1045) in the No Peel arm, primarily owing to the higher reoperation rate in the No Peel arm. The mean additional QALYs from ILM peel at 6 months were 0.002 (95% CI 0.01 to 0.013), adjusting for baseline EQ-5D and other minimisation factors. A mean incremental cost per QALY was not computed, as Peeling was on average less costly and slightly more effective. A stochastic analysis suggested that there was more than a 90% probability that Peeling would be cost-effective at a willingness-to-pay threshold of £20 000 per QALY. Conclusion: Although there is no evidence of a statistically significant difference in either costs or QALYs between macular hole surgery with or without ILM peeling, the balance of probabilities is that ILM Peeling is likely to be a cost-effective option for the treatment of macular holes. Further long-term follow-up data are needed to confirm these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between central corneal thickness (CCT) and anterior scleral thickness (ST) in patients of primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), and ocular hypertension (OHT). PATIENTS AND METHODS: Consecutive patients with OHT, POAG, NTG, and normal individuals were recruited. CCT was measured by ultrasonic pachymetry, whereas ST was measured using ultrasonic biomicroscopy at the temporal quadrant, 2'mm posterior to the scleral spur. Investigators were masked to the diagnosis and CCT/ ultrasonic biomicroscopy data. Correlation between mean CCT and ST was analyzed. RESULTS: One hundred and twenty-four subjects (31 with OHT, 31 with POAG, 31 with NTG, and 31 normal individuals) were enrolled. The CCT (OHT 548.06±30.45'µm; POAG 519.39±42.95'µm; NTG 505.81±27.23'µm; controls 529.90±43.40'µm) was found to be thicker in patients with OHT than POAG (P=0.004) or NTG (P