984 resultados para Tests accuracy
Resumo:
analysis of a complex physical problem and the close agreement they achieved with observations. However, the following points need to be clarified. First of all the authors assume that during the initial phases of expansion, the Tayior's instability sets in due to the acceleraacceleration of lighter fluid against the more dense cold water.
Resumo:
Various field test (namely vibration tests on blocks or plates, steady-state vibration or Rayleigh wave tests, wave propagation tests, and cyclic load tests) were conducted at a number of sites in India to determine the dynamic shear modulus, G. Data obtained at different sites are described. The values of G obtained from the different tests at a given site vary widely. The rational approach for selecting the value of G from field tests for use in the analysis and design of soil-structure interaction problems under dynamic loads must account for the factors affecting G. The suggested approach, which provides a possible answer, is suitable in cohesionless soils below the water table where it is rather difficult, if not impossible, to obtain undisturbed samples.
Resumo:
Aims: Helicobacter pylori infection, although the prevalence is declining in Western world, is still responsible for several clinically important diseases. None of the diagnostic tests is perfect and in this study, the performance of three stool antigen tests was assessed. In areas of high H. pylori prevalence, the definition of patients with the greatest benefit from eradication therapy may be a problem; the role of duodenal gastric metaplasia in categorizing patients at risk for duodenal ulcer was evaluated in this respect. Whether persistent chronic inflammation and elevated H. pylori antibodies after successful eradication are associated with each other or with atrophic gastritis, a long term sequelae of H. pylori infection, were also studied. Patients and methods: The three stool antigen tests were assessed in pre- and post-eradication settings among 364 subjects in two studies as compared to the rapid urease test (RUT), histology, culture, the 13C-urea breath test (UBT) and enzyme immunoassay (EIA) based H. pylori serology. The association between duodenal gastric metaplasia with duodenal ulcer was evaluated in a retrospective study including 1054 patients gastroscopied due to clinical indications and 154 patients previously operated for duodenal ulcer. The extent of duodenal gastric metaplasia was assessed from histological specimens in different patient groups formed on the basis of gastroscopy findings and H. pylori infection. Chronic gastric inflammation (108 patients) and H. pylori antibodies and serum markers for atrophy (77 patients) were assessed in patients earlier treated for H. pylori. Results: Of the stool antigen tests studied, the monoclonal antibody-based EIA-test showed the highest sensitivity and specificity both in the pre-treatment setting (96.9% and 95.9%) and after therapy (96.9% and 97.8%). The polyclonal stool antigen test and the in-office test had at baseline a sensitivity of 91% and 94%, and a specificity of 96% and 89%, respectively and in a post-treatment setting, a sensitivity of 78% and 91%, and a specificity of 97%, respectively. Duodenal gastric metaplasia was strongly associated with H. pylori positive duodenal ulcer (odds ratio 42). Although common still five years after eradication, persistent chronic gastric inflammation (21%) and elevated H. pylori antibodies (33%) were neither associated with each other nor with atrophic gastritis. Conclusions: Current H. pylori infection can feasibly be diagnosed by a monoclonal antibody-based EIA test with the accuracy comparable to that of reference methods. The performance of the polyclonal test as compared to the monoclonal test was inferior especially in the post-treatment setting. The in-office test had a low specificity for primary diagnosis and hence positive test results should probably be confirmed with another test before eradication therapy is prescribed. The presence of widespread duodenal gastric metaplasia showed promising results in detecting patients who should be treated for H. pylori due to an increased risk of duodenal ulcer. If serology is used later on in patients with earlier successfully treated for H. pylori, it should be taken into account that H. pylori antibodies may persist elevated for years for unknown reason. However, this phenomenon was not found to be associated with persistent chronic inflammation or atrophic changes.
Resumo:
Helicobacter pylorin (helikobakteeri) tartunta saadaan yleensä lapsena ja tauti jää tavallisesti pysyväksi ilman täsmähoitoa. Onnistunut hoito parantaa pysyvästi helikobakteerista aiheutuvan mahan haavataudin ja näyttää ehkäisevän mahalaukun pahanlaatuisten muutosten kehittymistä. Aloitimme Vammalassa terveyskeskuksessa toteutetun kansainvälisesti ainutlaatuisen väestöpohjaisen helikobakteeritulehduksen seulonta- ja hoito-ohjelman pilottitutkimuksella 1994. 1996 kaikki 15-40-vuotiaat ja 1997-2000 15- ja 45-vuotiaat vammalalaiset kutsuttiin verinäyteseulontaan. Yhteensä 4626 henkilöä (75% kutsutuista) osallistui seulontaan. Vasta-ainepositiivisille tarjottiin helikobakteeritulehduksen lopettava lääkekuuri. Toiminnan seurauksena helikobakteeritulehduksen esiintyvyyden laskettiin vähentyneen 12%:sta 4%:iin 15-40-vuotiaiden ikäryhmässä. Tutkimme myös helikobakteerivasta-ainepositiivisten ja -negatiivisten eroja sekä helikobakteeritulehduksen riskitekijöitä kyselytutkimuksella. Lapsuudenkodin asumisahtauden, äidin matalan koulutusasteen, tupakoinnin, alkoholinkäytön, huonojen asunto-olojen ja ylävatsavaivoista johtuvien sairauslomien todettiin liittyvän helikobakteeritulehdukseen monimuuttuja-analyysissa. Tutkimme seulontaohjelmassa käyttämiemme IgG- ja IgA-luokan helikobakteeri-vasta-ainetestien luotettavuutta eri ikäryhmissä ottaen huomioon atrofisen gastriitin esiintyvyyden. 561 kliinisin perustein gastroskopoidun potilaan aineistossa IgG-testi osoittautui erittäin herkäksi kaikissa ikäryhmissä (99%). Tarkkuus oli myös vanhemmissa ikäryhmissä hyvä (97-93%), kun atrofista gastriittia sairastavat suljettiin pois. IgA- ja CagA-helikobakteerivasta-aineiden on todettu liittyvän lisääntyneeseen mahahaava- ja mahasyöpäriskiin. Analysoimme 560 henkilön pariseeruminäytteet, jotka oli otettu kahden vuosikymmenen välein, ja totesimme, että IgA-vasta-aineiden esiintyvyyden lisääntyyminen iän myötä johtuu paitsi syntymäajankohdasta ja uusista infektioista myös IgA-vasta-ainetasojen kohoamisesta helikobakteeritulehduksen aikana. Selvitimme myös CagA-vasta-ainetasojen muuttumista analysoimalla seeruminäytteet, jotka oli otettu kahden vuosikymmenen välein. Totesimme, että samanaikaisesti kun helikobakteerin esiintyvyys väestössä on alentunut, erityisesti CagA-positiiviset infektiot ovat vähentyneet. Tutkimuksemme osoittaa, että Suomessa terveyskeskuksen yhteydessä voidaan toteuttaa näin laajamittainen seulonta- ja hoito-ohjelma, johon suomalaiset osallistuvat aktiivisesti. Nähtäväksi jää, kuinka paljon ohjelma kykeni vähentämään helikobakteeritulehdukseen liittyviä myöhäisseuraamuksia.
Resumo:
The type A lantibiotic nisin produced by several Lactococcus lactis strains, and one Streptococcus uberis strainis a small antimicrobial peptide that inhibits the growth of a wide range of gram-positive bacteria, such as Bacillus, Clostridium, Listeria and Staphylococcus species. It is nontoxic to humans and used as a food preservative (E234) in more than 50 countries including the EU, the USA, and China. National legislations concerning maximum addition levels of nisin in different foods vary greatly. Therefore, there is a demand for non-laborious and sensitive methods to identify and quantify nisin reliably from different food matrices. The horizontal inhibition assay, based on the inhibitory effect of nisin to Micrococcus luteus is the base for most quantification methods developed so far. However, the sensitivity and accuracy of the agar diffusion method is affected by several parameters. Immunological tests have also been described. Taken into account the sensitivity of immunological methods to interfering substances within sample matrices, and possible cross-reactivities with lantibiotics structurally close to nisin, their usefulness for nisin detection from food samples remains limited. The proteins responsible for nisin biosynthesis, and producer self-immunity are encoded by genes arranged into two inducible operons, nisA/Z/QBTCIPRK and nisFEG, which also contain internal, constitutive promoters PnisI and PnisR. The transmembrane histidine kinase NisK and the response regulator NisR form a two-component signal transduction system, in which NisK autophosphorylates after exposure to extra cellular nisin, and subsequently transfers the phosphate to NisR. The phosphorylated NisR then relays the signal downstream by binding to two regulated promoters in the nisin gene cluster, i.e the nisA/Z/Qand the nisF promoters, thus activating transcription of the structural gene nisA/Z/Q and the downstream genes nisBTCIPRK from the nisA/Z/Q promoter, and the genes nisFEG from the nisF promoter. In this work two novel and highly sensitive nisin bioassays were developed. Both of these quantification methods were based on NisRK mediated, nisin induced Green Fluorescent Protein (GFP) fluorescence. The suitabilities of these assays for quantifica¬tion of nisin from food samples were evaluated in several food matrices. These bioassays had nisin sensitivities in the nanogram or picogram levels. In addition, shelf life of nisin in cooked sausages and retainment of the induction activity of nisin in intestinal chyme (intestinal content) was assessed.
Resumo:
This paper suggests a scheme for classifying online handwritten characters, based on dynamic space warping of strokes within the characters. A method for segmenting components into strokes using velocity profiles is proposed. Each stroke is a simple arbitrary shape and is encoded using three attributes. Correspondence between various strokes is established using Dynamic Space Warping. A distance measure which reliably differentiates between two corresponding simple shapes (strokes) has been formulated thus obtaining a perceptual distance measure between any two characters. Tests indicate an accuracy of over 85% on two different datasets of characters.
Resumo:
ALICE (A Large Ion Collider Experiment) is an experiment at CERN (European Organization for Nuclear Research), where a heavy-ion detector is dedicated to exploit the unique physics potential of nucleus-nucleus interactions at LHC (Large Hadron Collider) energies. In a part of that project, 716 so-called type V4 modules were assembles in Detector Laboratory of Helsinki Institute of Physics during the years 2004 - 2006. Altogether over a million detector strips has made this project the most massive particle detector project in the science history of Finland. One ALICE SSD module consists of a double-sided silicon sensor, two hybrids containing 12 HAL25 front end readout chips and some passive components, such has resistors and capacitors. The components are connected together by TAB (Tape Automated Bonding) microcables. The components of the modules were tested in every assembly phase with comparable electrical tests to ensure the reliable functioning of the detectors and to plot the possible problems. The components were accepted or rejected by the limits confirmed by ALICE collaboration. This study is concentrating on the test results of framed chips, hybrids and modules. The total yield of the framed chips is 90.8%, hybrids 96.1% and modules 86.2%. The individual test results have been investigated in the light of the known error sources that appeared during the project. After solving the problems appearing during the learning-curve of the project, the material problems, such as defected chip cables and sensors, seemed to induce the most of the assembly rejections. The problems were typically seen in tests as too many individual channel failures. Instead, the bonding failures rarely caused the rejections of any component. One sensor type among three different sensor manufacturers has proven to have lower quality than the others. The sensors of this manufacturer are very noisy and their depletion voltage are usually outside of the specification given to the manufacturers. Reaching 95% assembling yield during the module production demonstrates that the assembly process has been highly successful.
Resumo:
Thin-walled steel hollow flange channel beams known as LiteSteel beam (LSB) sections were developed for use as joists and bearers in various flooring systems. However, they are subjected to specific buckling and failure modes, one of them being web crippling. Despite considerable research in this area, much of the current design predictions for cold-formed steel sections are not directly applicable to LSBs. This is due to the geometry of the LSB, which consists of two closed rectangular hollow flanges, and its unique residual stress characteristics and initial geometric imperfections. Hence an experimental study was conducted to investigate the web crippling behaviour and capacities of LSBs with their flanges fastened to supports. Thirty nine web crippling tests were conducted under two flange load cases (End Two Flange (ETF) and Interior Two Flange (ITF)). Test results showed that for ETF load case the web crippling capacities increased by 50% on average while they increased by 97% for ITF load case when flanges were fastened to supports. Comparison of the ultimate web crippling capacities from tests showed that AS/NZS 4600 and AISI S100 web crippling design equations are conservative for LSB sections with flanges fastened to supports under ETF and ITF load cases. Hence new equations were proposed to determine the web crippling capacities of LSBs with flanges fastened to supports. This paper presents the details of the experimental study into the web crippling behaviour of LSB sections with their flanges fastened under ETF and ITF load cases, and the results.
Resumo:
The intermittently rivet fastened Rectangular Hollow Flange Channel Beam (RHFCB) is a new cold-formed hollow section proposed as an alternative to welded hollow flange channel beams. It is a monosymmetric channel section made by intermittently rivet fastening two torsionally rigid rectangular hollow flanges to a web plate. This process enables the end users to choose an effective combination of different web and flange plate sizes to achieve optimum design capacities. Recent research studies focused mainly on the shear behaviour of the most commonly used lipped channel beam and welded hollow flange beam sections. However, the shear behaviour of rivet fastened RHFCB has not been investigated. Therefore a detailed experimental study involving 24 shear tests was undertaken to investigate the shear behaviour and capacities of rivet fastened RHFCBs. Simply supported test specimens of RHFCB with aspect ratios of 1.0 and 1.5 were loaded at mid-span until failure. Comparison of experimental shear capacities with corresponding predictions from the current Australian cold-formed steel design rules showed that the current design rules are very conservative for the shear design of rivet fastened RHFCBs. Significant improvements to web shear buckling occurred due to the presence of rectangular hollow flanges while considerable post-buckling strength was also observed. Such enhancements to the shear behaviour and capacity were achieved with a rivet spacing of 100 mm. Improved design rules were proposed for rivet fastened RHFCBs based on the current shear design equations in AISI S100 and the direct strength method. This paper presents the details of this experimental investigation and the results.
Resumo:
The rivet-fastened rectangular hollow flange channel beam (RHFCB) is a new cold-formed hollow section proposed as an alternative to welded hollow flange steel beams. No research has been undertaken on the shear behaviour and strength of rivet fastened RHFCBs with web openings. Hence a detailed experimental study involving 30 shear tests was undertaken to investigate the shear behaviour and strength of rivet fastened RHFCBs with web openings. Experimental results showed that the current design rules are inadequate for the shear design of Rivet fastened RHFCBs with web openings. Improved design equations have been proposed for the shear strength of rivet fastened RHFCBs with web openings.
Resumo:
The rivet-fastened rectangular hollow flange channel beam (RHFCB) is a new cold-formed hollow section proposed as an alternative to welded hollow flange steel beams. To date, no investigation has been conducted on their web crippling behaviour and strengths. Hence an experimental study was conducted to investigate the web crippling behaviour and capacities of rivet fastened RHFCBs under End Two Flange (ETF) and Interior Two Flange (ITF) load cases. Experimental results showed that the current design rules are unconservative for rivet fastened RHFCB sections under ETF and ITF load cases. Hence new equations were proposed to determine the web crippling capacities of rivet fastened RHFCBs.
Resumo:
Primary biliary cirrhosis (PBC) is caused by an autoimmune inflammation of the small bile ducts. It results to destruction of bile ducts, accumulation of the bile in the liver, and cirrhosis. The prevalence and incidence of PBC is increasing in the Western world. The prevalence is highest in the USA (402 per million) and incidence in Scotland (49/million/year). Our aim was to assess the epidemiology of PBC in Finland. Patients for the epidemiological study were searched from the hospital discharge records from year 1988 to 1999.The prevalence rose from 103 to 180/million from 1988 to 1999, an annual increase of 5.1%. The incidence rose from 12 to 17 /million/year, an annual increase of 3.5%. The age at death increased markedly from 65 to 76 years. The risk of liver related deaths diminished over time. The treatment of PBC is based on Ursodeoxycholic acid (UDCA). During 20 years 50% of patients end up with cirrhosis. Our treatment option was to combine budesonide, a potent corticosteroid with a high first pass metabolism in the liver, to UDCA and evaluate the liver effects and systemic effects such as bone mass density (BMD) changes. Our aim was to find out if combination of laboratory tests would serve as a surrogate marker for PBC and help reducing the need for liver biopsy. Non-cirrhotic PBC patients were randomized to receive budesonide 6 mg/day combined to UDCA 15 mg /kg/day or UDCA alone for three years. The combination therapy with UDCA and budesonide was effective: stage improved 22%, fibrosis 25%, and inflammation 32%. In the UDCA group the changes were: 20% deterioriation in stage and 70% in fibrosis, but a 10% improvement in inflammation. BMD in femoral neck decreased by 3.6% in the combination group and by 1.9% in the UDCA group. The reductions in lumbar spine were 2.8% and 0.7%. Pharmacokinetics did not differ between the stages of PBC. HA, PIIINP, bile acids, and AST were significantly different within stages I-III and could differentiate the mild fibrosis (F0F1) from the moderate (F2F3). The combination of these individual markers (PBC-score) further improved the accuracy. The area under the ROC of the PBC score, using a cut of value 66, had a sensitivity of 81.4% and a specificity of 65.2% to classify the stage of PBC. The prevalence of PBC in Finland increases, which results from increasing incidence and improved survival. The combination of budesonide and UDCA improves liver histology compared to UDCA alone in non-cirrhotic stages of PBC. The treatment may reduce BMD. Hyaluronic acid, PIIINP, AST, and bile acids may serve as tools to monitor the treatment response in the early stages of PBC. The budesonide and UDCA combination therapy is an option for those patients who do not receive full response from UDCA and are still at the non-cirrhotic stage of PBC.
Resumo:
Objectives: To evaluate the applicability of visual feedback posturography (VFP) for quantification of postural control, and to characterize the horizontal angular vestibulo-ocular reflex (AVOR) by use of a novel motorized head impulse test (MHIT). Methods: In VFP, subjects standing on a platform were instructed to move their center of gravity to symmetrically placed peripheral targets as fast and accurately as possible. The active postural control movements were measured in healthy subjects (n = 23), and in patients with vestibular schwannoma (VS) before surgery (n = 49), one month (n = 17), and three months (n = 36) after surgery. In MHIT we recorded head and eye position during motorized head impulses (mean velocity of 170º/s and acceleration of 1 550º/s²) in healthy subjects (n = 22), in patients with VS before surgery (n = 38) and about four months afterwards (n = 27). The gain, asymmetry and latency in MHIT were calculated. Results: The intraclass correlation coefficient for VFP parameters during repeated tests was significant (r = 0.78-0.96; p < 0.01), although two of four VFP parameters improved slightly during five test sessions in controls. At least one VFP parameter was abnormal pre- and postoperatively in almost half the patients, and these abnormal preoperative VFP results correlated significantly with abnormal postoperative results. The mean accuracy in postural control in patients was reduced pre- and postoperatively. A significant side difference with VFP was evident in 10% of patients. In the MHIT, the normal gain was close to unity, the asymmetry in gain was within 10%, and the latency was a mean ± standard deviation 3.4 ± 6.3 milliseconds. Ipsilateral gain or asymmetry in gain was preoperatively abnormal in 71% of patients, whereas it was abnormal in every patient after surgery. Preoperative gain (mean ± 95% confidence interval) was significantly lowered to 0.83 ± 0.08 on the ipsilateral side compared to 0.98 ± 0.06 on the contralateral side. The ipsilateral postoperative mean gain of 0.53 ± 0.05 was significantly different from preoperative gain. Conclusion: The VFP is a repeatable, quantitative method to assess active postural control within individual subjects. The mean postural control in patients with VS was disturbed before and after surgery, although not severely. Side difference in postural control in the VFP was rare. The horizontal AVOR results in healthy subjects and in patients with VS, measured with MHIT, were in agreement with published data achieved using other techniques with head impulse stimuli. The MHIT is a non-invasive method which allows reliable clinical assessment of the horizontal AVOR.
Resumo:
Objective: We aimed to assess the impact of task demands and individual characteristics on threat detection in baggage screeners. Background: Airport security staff work under time constraints to ensure optimal threat detection. Understanding the impact of individual characteristics and task demands on performance is vital to ensure accurate threat detection. Method: We examined threat detection in baggage screeners as a function of event rate (i.e., number of bags per minute) and time on task across 4 months. We measured performance in terms of the accuracy of detection of Fictitious Threat Items (FTIs) randomly superimposed on X-ray images of real passenger bags. Results: Analyses of the percentage of correct FTI identifications (hits) show that longer shifts with high baggage throughput result in worse threat detection. Importantly, these significant performance decrements emerge within the first 10 min of these busy screening shifts only. Conclusion: Longer shift lengths, especially when combined with high baggage throughput, increase the likelihood that threats go undetected. Application: Shorter shift rotations, although perhaps difficult to implement during busy screening periods, would ensure more consistently high vigilance in baggage screeners and, therefore, optimal threat detection and passenger safety.
Resumo:
Purpose: To examine the effects of gaze position and optical blur, similar to that used in multifocal corrections, on stepping accuracy for a precision stepping task among older adults. Methods: Nineteen healthy older adults (mean age, 71.6 +/- 8.8 years) with normal vision performed a series of precision stepping tasks onto a fixed target. The stepping tasks were performed using a repeated-measures design for three gaze positions (fixating on the stepping target as well as 30 and 60 cm farther forward of the stepping target) and two visual conditions (best-corrected vision and with +2.50DS blur). Participants' gaze position was tracked using a head-mounted eye tracker. Absolute, anteroposterior, and mediolateral foot placement errors and within-subject foot placement variability were calculated from the locations of foot and floor-mounted retroreflective markers captured by flash photography of the final foot position. Results: Participants made significantly larger absolute and anteroposterior foot placement errors and exhibited greater foot placement variability when their gaze was directed farther forward of the stepping target. Blur led to significantly increased absolute and anteroposterior foot placement errors and increased foot placement variability. Furthermore, blur differentially increased the absolute and anteroposterior foot placement errors and variability when gaze was directed 60 cm farther forward of the stepping target. Conclusions: Increasing gaze position farther ahead from stepping locations and the presence of blur negatively impact the stepping accuracy of older adults. These findings indicate that blur, similar to that used in multifocal corrections, has the potential to increase the risk of trips and falls among older populations when negotiating challenging environments where precision stepping is required, particularly as gaze is directed farther ahead from stepping locations when walking.