998 resultados para Structural reinforcement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methamphetamine (METH) is a potent psychostimulant highly used worldwide. Recent studies evidenced the involvement of METH in the breakdown of the blood-brain-barrier (BBB) integrity leading to compromised function. The involvement of the matrix metalloproteinases (MMPs) in the degradation of the neurovascular matrix components and tight junctions (TJs) is one of the most recent findings in METH-induced toxicity. As BBB dysfunction is a pathological feature of many neurological conditions, unveiling new protective agents in this field is of major relevance. AcetylL-carnitine (ALC) has been described to protect the BBB function in different paradigms, but the mechanisms underling its action remain mostly unknown. Here, the immortalized bEnd.3 cell line was used to evaluate the neuroprotective features of ALC in METH-induced damage. Cells were exposed to ranging concentrations of METH, and the protective effect of ALC 1 mM was assessed 24 h after treatment. F-actin rearrangement, TJ expression and distribution, and MMPs activity were evaluated. Integrin-linked kinase (ILK) knockdown cells were used to assess role of ALC in ILK mediated METHtriggered MMPs’ activity. Our results show that METH led to disruption of the actin filaments concomitant with claudin-5 translocation to the cytoplasm. These events were mediated by MMP-9 activation in association with ILK overexpression. Pretreatment with ALC prevented METH-induced activation of MMP-9, preserving claudin-5 location and the structural arrangement of the actin filaments. The present results support the potential of ALC in preserving BBB integrity, highlighting ILK as a new target for the ALC therapeutic use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas child care quality has been extensively studied in the U.S., there is much less information about the quality of child care in other countries.With one of the highest maternal employment rates in Europe, it is important to examine child care in Portugal. Thirty toddler classrooms in child care centers were observed. The purpose of this studywas to determine whether structural features account for overall toddler child care quality. Results showed younger and better-paid teachers provided better toddler child care quality. Space available per childwas not a statistically significant predictor of toddler child care quality.Overall quality results suggest some issues to be addressed by early education policy makers and indicate the need to promote quality in Portuguese toddler child care programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a Doctoral Degree in Biology by Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A engenharia civil, rege-se pela garantia de segurança e de funcionalidade das obras que projeta e executa. Para cumprir tais requisitos, é necessário durante a sua vida útil, no final da construção, reforço ou reabilitação, proceder à avaliação da conformidade entre o comportamento real da estrutura e os pressupostos subjacentes ao projeto. Esta dissertação tem como objetivo a compreensão e análise do comportamento estrutural da Ponte sobre o Rio Sorraia, através da realização de ensaios de carga apoiados pela conceção de um modelo numérico devidamente calibrado, capaz de simular a resposta da estrutura, o mais próximo possível do observável na realidade. Para alcançar o objetivo pré definido elencam-se as metodologias relevantes, descrevem-se os tipos de ensaios de carga realizados em pontes/viadutos e faz-se referência aos aparelhos de medição que estão na base da instrumentação aplicada em obras. Esta introdução foca-se ainda na modelação numérica, permitindo o conhecimento básico necessário para a criação e atualização de modelos numéricos de pontes. Relativamente ao caso de estudo expõe-se a realização do ensaio de carga, descrevendo todo o processo, bem como os resultados obtidos ao nível das grandezas de medição estudadas. Aqui é concebido um modelo numérico base da ponte, alvo de discussão ao nível do comportamento estrutural, baseada na validação dos resultados obtidos por via experimental, através da comparação com os obtidos por via numérica. Por fim, o estudo e seleção de diversos parâmetros da modelação, facultando a calibração do modelo numérico da ponte. Os resultados obtidos neste modelo comprovam o seu elevado potencial, no apoio à observação e compreensão do comportamento de estruturas através da realização de ensaios de carga. O sucesso da realização de uma análise do comportamento de estruturas, através de ensaios de carga, depende assim fundamentalmente, da correta execução do ensaio, da correta conceção e atualização do modelo numérico e da interligação entre os resultados experimentais e numéricos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is a contribution to the definition and assessment of structural robustness. Special emphasis is given to reliability of reinforced concrete structures under corrosion of longitudinal reinforcement. On this communication several authors’ proposals in order to define and measure structural robustness are analyzed and discussed. The probabilistic based robustness index is defined, considering the reliability index decreasing for all possible damage levels. Damage is considered as the corrosion level of the longitudinal reinforcement in terms of rebar weight loss. Damage produces changes in both cross sectional area of rebar and bond strength. The proposed methodology is illustrated by means of an application example. In order to consider the impact of reinforcement corrosion on failure probability growth, an advanced methodology based on the strong discontinuities approach and an isotropic continuum damage model for concrete is adopted. The methodology consist on a two-step analysis: on the first step an analysis of the cross section is performed in order to capture phenomena such as expansion of the reinforcement due to the corrosion products accumulation and damage and cracking in the reinforcement surrounding concrete; on the second step a 2D deteriorated structural model is built with the results obtained on the first step of the analysis. The referred methodology combined with a Monte Carlo simulation is then used to compute the failure probability and the reliability index of the structure for different corrosion levels. Finally, structural robustness is assessed using the proposed probabilistic index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One parameter that influences the adhesively bonded joints performance is the adhesive layer thickness. Hence, its effect has to be investigated experimentally and should be taken into consideration in the design of adhesive joints. Most of the results from literature are for typical structural epoxy adhesives which are generally formulated to perform in thin sections. However, polyurethane adhesives are designed to perform in thicker sections and might have a different behavior as a function of adhesive thickness. In this study, the effect of adhesive thickness on the mechanical behavior of a structural polyurethane adhesive was investigated. The mode I fracture toughness of the adhesive was measured using double-cantilever beam (DCB) tests with various thicknesses of the adhesive layer ranging from 0.2 to 2 mm. In addition, single lap joints (SLJs) were fabricated and tested to assess the influence of adhesive thickness on the lap-shear strength of the adhesive. An increasing fracture toughness with increasing adhesive thickness was found. The lap-shear strength decreases as the adhesive layer gets thicker, but in contrast to joints with brittle adhesives the decrease trend was less pronounced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the behaviour of two structural adhesives modified with thermally expandable particles (TEPs) was investigated as a preliminary study for further investigations on the potential of TEPs in adhesive joints. Tensile bulk tests were performed to get the tensile properties of the adhesives and TEPs-modified adhesives. In order to determine the expansion temperature of the particles while encapsulated in these particular adhesive systems, the variation of the volume of adhesive samples modified with different TEPs concentration as a function of temperature was measured. Further, the possibility of any chemical interactions between TEPs and adhesives matrix in the TEPs-modified specimens was verified by a Fourier transform infrared spectroscopy analysis. Finally, the fracture surfaces of the unmodified and TEPs-modified specimens, as well as the dispersion and the morphology of the particles, were examined by a scanning electron microscopy analysis. It was found that the stiffness of the TEPs-modified adhesives is not affected by incorporation of TEPs in the adhesives matrix, while the tensile yield strength decreased by increasing the wt% TEPs content. In applications of such particular materials (TEPs-modified adhesives), the temperature should be controlled to stay between 90°C and 120°C in order to obtain the highest expansion ratio. At a lower temperature, not all the particles will expand, and above, the TEPs will deteriorate and as a result the TEPs-modified adhesives will deteriorate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesively bonded techniques are an attractive option to repair aluminium structures, compared to more traditional methods. Actually, as a result of the improvement in the mechanical characteristics of adhesives, adhesive bonding has progressively replaced the traditional joining methods. There are several bonded repair configurations, as single-strap, double-strap and scarf. Compared with strap repairs, scarf repairs have the advantages of a higher efficiency and the absence of aerodynamic disturbance. The higher efficiency is caused by the elimination of the significant joint eccentricities of strap repairs. Moreover, stress distributions along the bond length are more uniform, due to tapering of the scarf edges. The main disadvantages of this technique are the difficult machining of the surfaces, associated costs and requirement of specialised labour. This work reports on an experimental and numerical study of the tensile behaviour of two-dimensional (2D) scarf repairs of aluminium structures bonded with the ductile epoxy adhesive Araldite® 2015. The numerical analysis, by Finite Elements (FE), was performed in Abaqus® and used cohesive zone models (CZM) for the simulation of damage onset and growth in the adhesive layer, thus enabling the strength prediction of the repairs. A parametric study was performed on the scarf angle (α) and different configurations of external reinforcement (applied on one or two sides of the repair, and also different reinforcement lengths). The obtained results allowed the establishment of design guidelines for repairing, showing that the use of external reinforcements enables increasing α for equal strength recovery, which makes the repair procedure easier. The numerical technique was accurate in predicting the repairs’ strength, enabling its use for design and optimisation purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The isolation of the bartolosides, unprecedented cyanobacterial glycolipids featuring aliphatic chains with chlorine substituents and C-glycosyl moieties, is reported. Their chlorinated dialkylresorcinol (DAR) core presented a major structural-elucidation challenge. To overcome this, we discovered the bartoloside (brt) biosynthetic gene cluster and linked it to the natural products through in vitro characterization of the DAR-forming ketosynthase and aromatase. Bioinformatic analysis also revealed a novel potential halogenase. Knowledge of the bartoloside biosynthesis constrained the DAR core structure by defining key pathway intermediates, ultimately allowing us to determine the full structures of the bartolosides. This work illustrates the power of genomics to enable the use of biosynthetic information for structure elucidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a short summary of some aspects of structural change models, and is not intended to be comprehensive survey or review. Many important works have been left out. Also, the presentation was not intended to be rigorous nor general. It’s main purpose is only to focus on some recent developments in this area and motivate the reader to learn more.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho consiste em efetuar o dimensionamento estrutural de um edifício em betão armado, contemplando as diferentes fases, desde a conceção inicial, com a definição do modelo estrutural e escolha criteriosa dos elementos e soluções constituintes, até à fase final de dimensionamento, considerando para além das cargas gravíticas, a ação do vento e a ação sísmica. No âmbito deste trabalho considerou-se o dimensionamento de elementos estruturais nomeadamente, sapatas, paredes, pilares, vigas e lajes, com a verificação de segurança à flexão simples, flexão composta, esforço transverso e punçoamento, consoante a necessidade de cada elemento. Para tal, foi desenvolvido uma folha de cálculo automático (Macro) que permite a verificação da capacidade resistente de secções, à flexão simples e ao esforço transverso, quer em elementos com ou sem armadura de esforço transverso. Os esforços atuantes que estiveram na origem das verificações estruturais foram calculados com base na aplicação de um programa tridimensional de elementos finitos, nomeadamente o programa de cálculo ROBOT STRUCTURAL ANALYSIS. Os Critérios Gerais de Dimensionamento considerados, com base na regulamentação em vigor em Portugal – RSA, REBAP e Eurocódigos, bem como as Hipóteses de Cálculo consideradas na verificação aos estados limites últimos dos elementos estruturais são detalhadamente enunciados ao longo do trabalho. Os desenhos de elementos estruturais dimensionados, bem como os desenhos de dimensionamento do edifício encontram-se em Anexo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Old timber structures may show significant variation in the cross section geometry along the same element, as a result of both construction methods and deterioration. As consequence, the definition of the geometric parameters in situ may be both time consuming and costly. This work presents the results of inspections carried out in different timber structures. Based on the obtained results, different simplified geometric models are proposed in order to efficiently model the geometry variations found. Probabilistic modelling techniques are also used to define safety parameters of existing timber structures, when subjected to dead and live loads, namely self-weight and wind actions. The parameters of the models have been defined as probabilistic variables, and safety of a selected case study was assessed using the Monte Carlo simulation technique. Assuming a target reliability index, a model was defined for both the residual cross section and the time dependent deterioration evolution. As a consequence, it was possible to compute probabilities of failure and reliability indices, as well as, time evolution deterioration curves for this structure. The results obtained provide a proposal for definition of the cross section geometric parameters of existing timber structures with different levels of decay, using a simplified probabilistic geometry model and considering a remaining capacity factor for the decayed areas. This model can be used for assessing the safety of the structure at present and for predicting future performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis for the master degree in Structural and Functional Biochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como principal objetivo a avaliação do estado de conservação de uma ponte ferroviária metálica centenária para posteriormente se efetuar o reforço desta. O objeto de estudo foi a Ponte de Maçaínhas, uma ponte metálica treliçada que se situa na linha da Beira Baixa permitindo a ligação entre a Guarda e a Covilhã. Este trabalho envolveu um estudo profundo de vários conteúdos normativos relativos a ações em pontes ferroviárias e ações ambientais. Este estudo estende-se ainda ao campo das verificações regulamentares e critérios de segurança estrutural adequadas ao presente contexto. A operação de reforço começou numa rigorosa análise dos componentes estruturais da ponte, através do estudo de plantas e de um extenso registo fotográfico, para posteriormente se conceber um modelo numérico que traduzisse a situação real. Ao modelo concebido foram aplicadas as cargas regulamentares adequadas por forma a entender o comportamento que a ponte apresenta perante estas e se as suas secções transversais apresentam capacidade resistente suficiente. Caso estas não apresentem capacidade resistente suficiente teriam de ser intervencionadas. Concluído o processo de avaliação estrutural e de reforço, procedeu-se à verificação do comportamento da estrutura reforçada perante as ações de projeto. Com isto pretende-se avaliar se os esforços se distribuem da mesma maneira ou se a operação de reforço teve algum efeito na distribuição destes. Por último, para avaliar o comportamento da estrutura perante a passagem de tráfego real, realizaram-se análises dinâmicas que tiveram por base um grupo de veículos que habitualmente circulam na linha da Beira Baixa e um comboio de alta velocidade. Estas análises foram realizadas tanto para a situação pré reforço como pós reforço. Desta forma conseguiu-se fazer um paralelo entre ambas as condições e perceber se a operação de reforço foi bem-sucedida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho pretende contribuir para a gestão das intervenções de reparação e de reforço das escolas do concelho de Matosinhos com estrutura de betão armado. Apresenta-se uma síntese sobre a história do edifício escolar e do seu desenvolvimento em território nacional. Desenvolve-se uma pesquisa bibliográfica sobre metodologias de inspeção adotadas em território nacional e internacionalmente. Identificaram-se diferentes tipologias estruturais e arquitetónicas das escolas de Matosinhos, selecionou-se a mais representativa e, aparentemente, a que envolve casos com estados de conservação mais deficientes, definiu-se uma metodologia de inspeção estrutural e desenvolveram-se as respetivas fichas de inspeção. Selecionou-se e inspecionou-se visualmente um corpo da Escola Básica da Portela, de tipologia P3 e realizaram-se diferentes ensaios de diagnóstico. Comparam-se os respetivos resultados com os obtidos na inspeção da Escola da Amieira, do mesmo concelho e com a mesma tipologia. Propõem-se soluções de reparação com base no resultado da inspeção visual, nos ensaios de diagnóstico e na norma NP EN 1504-9. Estima-se o respetivo custo e sugere-se uma metodologia de extrapolação das conclusões e do estabelecimento de uma estimativa orçamental das intervenções de reparação das restantes escolas tipo P3 deste concelho e de outras com idênticas tipologias, localizações e condições ambientais envolventes.