980 resultados para Specimen thickness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of specimen size, in comparison with the ISO Standard, on the three point flexural strength of resin composite restorative materials Filtek Supreme and Filtek Z-250. Forty specimens were fabricated for each material with the following length, width and thickness measurements (n = 10): 1) 20 × 2 × 2 mm (ISO 4049); 2) 10 × 2 × 1 mm; 3) 10 × 1 × 1 mm; 4) 8 × 0.8 × 0.8 mm. The composites were inserted in a single increment into two-piece metal device and light-polymerized. The specimens were dry stored at 37 ± 1 °C and protected from light for 7 days. After this period, flexural strength was measured by three-point flexure test using MTS 810 equipment, with a load cell of 10 kN at a speed of 0.5 mm/min. For the evaluated sizes, the results showed significant variability (p = 0.00) with values when compared with the ISO Standard (116.700 MPa), being statistically higher for the test specimens measuring 10 × 1 × 1 mm (142.530 MPa), similar for those of 10  ×  2  ×  1  mm (115.815 MPa) and lower for those of 8 × 0.8 × 0.8 mm (86.650 MPa). There was statistical equality (p = 0.08) for the studied composites (Filtek Supreme, 125.270 MPa; Filtek Z-250, 108.130 MPa). Specimens measuring 10 × 2 × 1 mm provided flexural strength values equivalent to those obtained in the sizes recommended by the ISO 4049 standard, with lower consumption of material, energy and time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Acral lentiginous melanoma is a melanoma with poor prognosis which is frequently diagnosed at an advanced stage. Since the thickness of tumour is one of the main prognostic factors, this case can exemplify how important complete histological analyses looking for focal invasiveness can be.Case report: A 77 year-old woman with a black spot with slow progressive growth on the left plantar region. She sought medical attention due to the expansion onto the dorsal surface of toes. The lesion had irregular borders and had spread to half the plantar surface. Histopathology confirmed the clinical suspicion of acral lentiginous melanoma Clark level IV and 2.6 mm Breslow thickness. The surgical specimen was entirely processed for histological evaluation, requiring 53 slides. Tumor dermal invasion was detected in only three out of 53 glass slides as the invasiveness was not identified by clinical, dermatoscopy or macroscopy exams.Conclusion: Sectioning through the entire lesion is considered very important to determinate the appropriate stage of the disease and the correct treatment and patient follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results of the analysis of dynamic behavior of flashover phenomenon on the high voltage-polluted insulators are presented. These results were taken from a mathematical and an experimental model that introduce the variable thickness influence of the layer pollution deposited on the high-voltage insulator surface. Analysis of the flashover was done by way of introducing a variation in the thickness of the channel of Obenaus' model, simulating a layer pollution of variable thickness. The objective was to obtain a better reproduction of the real layer pollution deposited on the insulator that works in the polluted regions. Two types of thickness variations were used: a sudden variation, using a step; and a soft variation, using a ramp; that were put along the way of the discharge. Comparison between the mathematical and experimental models showed that introduction of a ramp makes Obenaus' model more efficient in analyzing behavior of flashover phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of amoxicillin during early childhood has been associated with molar incisor hypomineralization. The objective of this study was to determine whether the use of amoxicillin interferes with enamel development, during secretion and early mineralization stages. Fifteen pregnant rats were randomly assigned to three groups that received physiological solution (sham group), 100 mg/kg/day amoxicillin (A100G), and 500 mg/kg/day amoxicillin (A500G). After birth, the pups in each group received the same treatment until post-natal day 7 or 12. The upper first molars were analyzed histomorphometrical and immunostaining with amelogenin on day 7, and MMP-20 on day 12 was performed using a semiquantitative method (H-score). At 7 days, several vacuolar structures were observed in the ameloblasts in the A100G and A500G groups. A significant reduction of the enamel thickness (P < 0.001) was found in amoxicillin-treated rats compared with the sham group. Significant differences were not observed in enamel thickness (P > 0.05) between the groups of 12-day-old rats. Moreover, significant differences were not observed in the number of amelogenin- and MMP-20-immunolabeled ameloblasts (P > 0.05) between groups. The present results suggest that amoxicillin interferes with the initial stages of amelogenesis by causing structural changes in the ameloblasts and a reduction of the enamel matrix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study used 12 photoelastics models with different height and thickness to evaluate if the axial loading of 100N on implants changes the morphology of the photoelastic reflection. Methods: For the photoelastic analysis, the models were placed in a reflection polariscope for observation of the isochromatic fringes patterns. The formation of these fringes resulted from an axial load of 100N applied to the midpoint of the healing abutment attached to the implant with 10.0mm x 3.75mm (Conexão, Sistemas de Próteses, Brazil). The tension in each photoelastic model was monitored, photographed and observed using the software Phothoshop 7.0. For qualitative analysis, the area under the implant apex was measured including the green band of the second order fringe of each model using the software Image Tool. After comparison of the areas, the performance generated by each specimen was defined regarding the axial loading. Results: There were alterations in area with different height and thickness of the photoelastic models. It was observed that the group III (30mm in height) presented the smallest area. Conclusion: There was variation in the size of the areas analyzed for different height and thickness of the models and the morphology of the replica may directly influence the result in researches with photoelastic models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Processo FAPESP: 2012/24545-3

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the opacity of the polymethylmethacrylate for ocular prosthesis using an ocular button, a colorless resin for the ocular prostheses, and 4 brands of acrylic colorless resin in the function of weathering (0, 504, or 1008 h) and thickness (1 and 3.5 mm). One hundred twenty specimens were confectioned (made) and allocated into 12 groups (n = 10). Opacity analysis was carried out with a spectrophotometer of visible ultraviolet reflection before and after weathering by 504 and 1008 hours. Data for the opacity were expressed in ΔE. Data were then analyzed statistically by analysis of variance and the Tukey test (P < 0.01). The data demonstrated statistically significant differences; manufactured ocular button (ΔE = 47.4) and the resin Vipi Cril (ΔE = 38.11) presented greater and minor values of opacity, respectively. The weathering showed statistical difference among times (0 h, ΔE = 36.32; 504 h, ΔE = 39.98; and 1008 h, ΔE = 43.9). Ocular button and evaluated resins presented greater values of opacity when presented in 3.5 mm in thickness. The values of opacity increased with the progression of the time of weathering, independent of the evaluated material and the thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an additional saurischian specimen from the Caturrita Formation (Norian) of the Parana Basin, southern Brazil. This material was collected in the 1950s and remained unstudied due to its fragmentary condition. Detailed comparisons with other saurischians worldwide reveal that some characters of the ilium, including the low ventral projection of the medial wall of the acetabulum and its concave ventral margin, together with the short triangular shape of the pre-acetabular process and its mound-like dorsocaudal edge, resemble those of sauropodomorphs such as Plateosaurus and Riojasaurus. This set of traits suggests that MN 1326-V has affinities with basal Sauropodomorpha, probably closer to plateosaurians than to Saturnalia-like taxa. Previous records of this clade in the Caturrita Formation include Unaysaurus, which has been related to Plateosaurus within Plateosauridae. Alternative schemes suggest that plateosaurids include Plateosaurus plus the Argentinean 'prosauropods' Coloradisaurus and Riojasaurus. Both hypotheses raise biogeographic questions, as a close relationship between faunas from South America and Europe excluding Africa and North America is not supported by geological and biostratigraphical evidence. Additionally, the absence of plateosaurids in other continents suggests that the geographical distribution of this taxon is inconsistent with the geological history of western Pangaea, and this demands further investigations of the phylogeny of sauropodomorphs or improved sampling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: In chronic renal failure patients under hemodialysis (HD) treatment, the availability of simple, safe, and effective tools to assess body composition enables evaluation of body composition accurately, in spite of changes in body fluids that occur in dialysis therapy, thus contributing to planning and monitoring of nutritional treatment. We evaluated the performance of bioelectrical impedance analysis (BIA) and the skinfold thickness sum (SKF) to assess fat mass (FM) in chronic renal failure patients before (BHD) and after (AHD) HD, using air displacement plethysmography (ADP) as the standard method. Design: This single-center cross-sectional trial involved comparing the FM of 60 HD patients estimated BHD and AHD by BIA (multifrequential; 29 women, 31 men) and by SKF with those estimated by the reference method, ADP. Body fat-free mass (FFM) was also obtained by subtracting the total body fat from the individual total weight. Results: Mean estimated FM (kg [%]) observed by ADP BHD was 17.95 +/- 0.99 kg (30.11% +/- 1.30%), with a 95% confidence interval (CI) of 16.00 to 19.90 (27.56 to 32.66); mean estimated FM observed AHD was 17.92 +/- 1.11 kg (30.04% +/- 1.40%), with a 95% CI of 15.74 to 20.10 (27.28 to 32.79). Neither study period showed a difference in FM and FFM (for both kg and %) estimates by the SKF method when compared with ADP; however, the BIA underestimated the FM and overestimated the FFM (for both kg and %) when compared with ADP. Conclusion: The SKF, but not the BIA, method showed results similar to ADP and can be considered adequate for FM evaluation in HD patients. (C) 2012 by the National Kidney Foundation, Inc. All rights reserved.