917 resultados para Selective modulator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon monoxide (CO) is a pollutant commonly recognized for its toxicological attributes, including CNS and cardiovascular effects. But CO is also formed endogenously in mammalian tissues. Endogenously formed CO normally arises from heme degradation in a reaction catalyzed by heme oxygenase. While inhibitors of endogenous CO production can raise arterial pressure, heme loading can enhance CO production and lead to vasodepression. Both central and peripheral tissues possess heme oxygenases and generate CO from heme, but the inability of heme substrate to cross the blood brain barrier suggests the CNS heme-heme oxygenase-CO system may be independent of the periphery. In the CNS, CO apparently acts in the nucleus tractus solitarii (NTS) promoting changes in glutamatergic neurotransmission and lowering blood pressure. At the periphery, the heme-heme oxygenase-CO system can affect cardiovascular functions in a two-fold manner; specifically: 1) heme-derived CO generated within vascular smooth muscle (VSM) can promote vasodilation, but 2) its actions on the endothelium apparently can promote vasoconstriction. Thus, it seems reasonable that the CNS-, VSM- and endothelial-dependent actions of the heme-heme oxygenase-CO system may all affect cardiac output and vascular resistance, and subsequently blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the benzodiazepine1 (BZ1) receptor agonist SX-3228 were studied in rats (N = 12) implanted for chronic sleep procedures. Administration of 0.5, 1.0 and 2.5 mg/kg SX-3228, sc, to rats 1 h after the beginning of the light phase of the light-dark cycle induced a significant reduction of rapid-eye-movement sleep (REMS) during the third recording hour. Moreover, slow wave sleep (SWS) was increased during the fourth recording hour after the two largest doses of the compound. Administration of 0.5, 1.0 and 2.5 mg/kg SX-3228 one hour after the beginning of the dark period of the light-dark cycle caused a significant and maintained (6-h recording period) reduction of waking (W), whereas SWS and light sleep (LS) were increased. REMS values tended to increase during the entire recording period; however, the increase was statistically significant only for the 1.0 mg/kg dose during the first recording hour. In addition, a significant and dose-related increase of power density in the delta and the theta regions was found during nonREM sleep (LS and SWS) in the dark period. Our results indicate that SX-3228 is a potent hypnotic when given to the rat during the dark period of the light-dark cycle. Moreover, the sleep induced by SX-3228 during the dark phase closely resembles the physiological sleep of the rat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dopamine nigrostriatal neurons are important for motor control and may contain a particularly dense population of ryanodine receptors involved in the control of dopamine release. To test this hypothesis, we used a classical model of unilateral selective lesion of these neurons in rats based on 6-hydroxydopamine (6-OHDA) injection into the substantia nigra. Binding of [3H]-GBR 12935, used as a presynaptic marker since it labels specifically the dopamine uptake complex, was dramatically decreased by 83-100% in striatum homogenates after 6-OHDA lesion. On the contrary, no reduction of [3H]-ryanodine binding was observed. The present data indicate that [3H]-ryanodine binding sites present in rat striatum are not preferentially localized in dopaminergic terminals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although gap junction channels are still widely viewed as large, non-specific pores connecting cells, the diversity in the connexin family has led more attention to be focused on their permeability characteristics. We summarize here the current status of these investigations, both published and on-going, that reveal both charge and size selectivity between gap junction channels composed of different connexins. In particular, this review will focus on quantitative approaches that monitor the expression level of the connexins, so that it is clear that differences that are seen can be attributed to channel properties. The degree of selectivity that is observed is modest compared to other channels, but is likely to be significant for biological molecules that are labile within the cell. Of particular relevance to the in vivo function of gap junctions, recent studies are summarized that demonstrate that the connexin phenotype can control the nature of the endogenous traffic between cells, with consequent effects on biological effects of gap junctions such as tumor suppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Additive manufacturing is a fast growing manufacturing technology capable of producing complex objects without the need for conventional manufacturing process planning. During the process the work piece is built by adding material one layer at a time according to a digital 3D CAD model. At first additive manufacturing was mainly used to make prototypes but the development of the technology has made it possible to also make final products. Welding is the most common joining method for metallic materials. As the maximum part size of additive manufacturing is often limited, it may sometimes be required to join two or more additively manufactured parts together. However there has been almost no research on the welding of additively manufactured parts so far, which means that there has been very little information available on the possible differences compared to the welding of sheet metal parts. The aim of this study was to compare the weld joint properties of additively manufactured parts to those of sheet metal parts. The welding process that was used was TIG welding and the test material was 316L austenitic stainless steel. Weld joint properties were studied by making tensile, bend and hardness tests and by studying the weld microstructures with a microscope. Results show that there are certain characteristics in the welds of additively manufactured parts. The building direction of the test pieces has some impact on the mechanical properties of the weld. Nevertheless all the welds exhibited higher yield strength than the sheet metal welds but at the same time elongation at break was lower. It was concluded that TIG welding is a feasible process for welding additively manufactured parts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most studies suggest that serotonin exerts an inhibitory control on the aggression process. According to experimental evidence, this amine also influences growth and development of the nervous tissue including serotoninergic neurons. Thus, the possibility exists that increased serotonin availability in young animals facilitates a long-lasting effect on aggressive responses. The present study aimed to investigate the aggressive behavior of adult rats (90-120 days) treated from the 1st to the 19th postnatal day with citalopram (CIT), a selective serotonin reuptake inhibitor (20 mg/kg, sc, every 3 days). Aggressive behavior was induced by placing a pair of rats (matched by weight) in a box (20 x 20 x 20 cm), and submitting them to a 20-min session of electric footshocks (five 1.6-mA - 2-s current pulses, separated by a 4-min intershock interval). When compared to the control group (rats treated for the same period with equivalent volumes of saline solution), the CIT group presented a 41.4% reduction in the duration of aggressive response. The results indicate that the repeated administration of CIT early in life reduces the aggressive behavior in adulthood and suggest that the increased brain serotoninergic activity could play a role in this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate here that acute third ventricle injections of GR 113808, a highly selective 5-HT4 antagonist, decrease water intake induced by a previous salt load while potentiating drinking elicited by hypovolemia induced by previous subcutaneous administration of polyethylene glycol in male Wistar rats (200 ± 20 g). At the dose of 160 nmol/rat, third ventricle injections of GR 113808 induced a significant reduction of water intake in salt-loaded animals after 120 min as compared to salt-loaded animals receiving third ventricle injections of saline (salt load + GR = 3.44 ± 0.41 ml, N = 12; salt load + saline = 5.74 ± 0.40 ml, N = 9). At the dose of 80 nmol/rat, GR 113808 significantly enhanced water intake in hypovolemic animals after 120 min as compared to hypovolemic animals receiving third ventricle injections of saline (hypovol + GR = 4.01 ± 0.27 ml, N = 8; hypovol + saline = 2.41 ± 0.23 ml, N = 12). We suggest that central 5-HT4 receptors may exert a positive drive on water intake due to hyperosmolarity and a negative input on drinking provoked by hypovolemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-metallic implants made of bioresorbable or biostable synthetic polymers are attractive options in many surgical procedures, ranging from bioresorbable suture anchors of arthroscopic surgery to reconstructive skull implants made of biostable fiber-reinforced composites. Among other benefits, non-metallic implants produce less interference in imaging. Bioresorbable polymer implants may be true multifunctional, serving as osteoconductive scaffolds and as matrices for simultaneous delivery of bone enhancement agents. As a major advantage for loading conditions, mechanical properties of biostable fiber-reinforced composites can be matched with those of the bone. Unsolved problems of these biomaterials are related to the risk of staphylococcal biofilm infections and to the low osteoconductivity of contemporary bioresorbable composite implants. This thesis was focused on the research and development of a multifunctional implant model with enhanced osteoconductivity and low susceptibility to infection. In addition, the experimental models for assessment, diagnostics and prophylaxis of biomaterial-related infections were established. The first experiment (Study I) established an in vitro method for simultaneous evaluation of calcium phosphate and biofilm formation on bisphenol-Aglycidyldimethacrylate and triethylenglycoldimethacrylate (BisGMA-TEGDMA) thermosets with different content of bioactive glass 45S5. The second experiment (Study II) showed no significant difference in osteointegration of nanostructured and microsized polylactide-co-glycolide/β-tricalcium phosphate (PLGA /β-TCP) composites in a minipig model. The third experiment (Study III) demonstrated that positron emission tomography (PET) imaging with the novel 68Ga labelled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) CD33 related sialic-acid immunoglobulin like lectins (Siglec-9) tracer was able to detect inflammatory response to S. epidermidis and S. aureus peri-implant infections in an intraosseous polytetrafluoroethylene catheter model. In the fourth experiment (Study IV), BisGMATEGDMA thermosets coated with lactose-modified chitosan (Chitlac) and silver nanoparticles exhibited antibacterial activity against S. aureus and P. aeruginosa strains in an in vitro biofilm model and showed in vivo biocompatibility in a minipig model. In the last experiment (Study V), a selective androgen modulator (SARM) released from a poly(lactide)-co-ε-caprolactone (PLCL) polymer matrix failed to produce a dose-dependent enhancement of peri-implant osteogenesis in a bone marrow ablation model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathogenesis of nonsteroidal anti-inflammatory drug (NSAID) enteropathy is a complex process involving the uncoupling of mitochondrial oxidative phosphorylation and inhibition of cyclooxygenase (COX). Rofecoxib, a selective inhibitor of COX-2, has shown less gastric damage, but the same beneficial effect is not clear in the case of the small bowel. Fifty-seven male Wistar rats (250-350 g) were divided into three groups (N = 19 each) to evaluate the effect of this NSAID on the rat intestine. The groups received 2.5 mg/kg rofecoxib, 7.5 mg/kg indomethacin or water with 5% DMSO (control) given as a single dose by gavage 24 h before the beginning of the experiment. A macroscopic score was used to quantify intestinal lesions and intestinal permeability was measured using [51Cr]-ethylenediaminetetraacetic acid ([51Cr]-EDTA). The extent of intestinal lesion, indicated by a macroscopic score, was significantly lower when rofecoxib was administered compared to indomethacin (rofecoxib = 0.0 vs indomethacin = 63.6 ± 25.9; P < 0.05) and did not differ from control. The intestinal permeability to [51Cr]-EDTA was significantly increased after indomethacin (control = 1.82 ± 0.4 vs indomethacin = 9.12 ± 0.8%; P < 0.0001), but not after rofecoxib, whose effect did not differ significantly from control (control = 1.82 ± 0.4 vs rofecoxib = 2.17 ± 0.4%; ns), but was significantly different from indomethacin (indomethacin = 9.12 ± 0.8 vs rofecoxib = 2.17 ± 0.4%; P < 0.001). In conclusion, the present data show that rofecoxib is safer than indomethacin in rats because it does not induce macroscopic intestinal damage or increased intestinal permeability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extracellular matrix proteins and cell adhesion receptors (integrins) play essential roles in the regulation of cell adhesion and migration. Interactions of integrins with the extracellular matrix proteins lead to phosphorylation of several intracellular proteins such as focal adhesion kinase, activating different signaling pathways responsible for the regulation of a variety of cell functions, including cytoskeleton mobilization. Once leukocytes are guided to sites of infection, inflammation, or antigen presentation, integrins can participate in the initiation, maintenance, or termination of the immune and inflammatory responses. The modulation of neutrophil activation through integrin-mediated pathways is important in the homeostatic control of the resolution of inflammatory states. In addition, during recirculation, T lymphocyte movement through distinct microenvironments is mediated by integrins, which are critical for cell cycle, differentiation and gene expression. Disintegrins are a family of low-molecular weight, cysteine-rich peptides first identified in snake venom, usually containing an RGD (Arg-Gly-Asp) motif, which confers the ability to selectively bind to integrins, inhibiting integrin-related functions in different cell systems. In this review we show that, depending on the cell type and the microenvironment, disintegrins are able to antagonize the effects of integrins or to act agonistically by activating integrin-mediated signaling. Disintegrins have proven useful as tools to improve the understanding of the molecular events regulated by integrin signaling in leukocytes and prototypes in order to design therapies able to interfere with integrin-mediated effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Depression found in Parkinson disease (PD) usually responds to selective serotonin reuptake inhibitors (SSRIs). Drugs that modify experimental neuroleptic catalepsy (NC) might affect extrapyramidal symptoms in PD. Therefore, the effects of SSRIs on NC were tested in mice, 26-36 g, separated by sex. Catalepsy was induced with haloperidol (H; 1 mg/kg, ip) and measured at 30-min intervals using a bar test. An SSRI (sertraline, ST; paroxetine, PX; fluoxetine) or vehicle (C) was injected ip 30 min before H. Dunnett's test was used for comparison of means. ST (1-5 mg/kg) or PX (1-5 mg/kg) attenuated NC, with a similar inhibition found in both sexes (5 mg/kg, 180 min: ST - males: 124 ± 10 vs 714 ± 15 s in C; females: 116 ± 10 vs 718 ± 6 s in C; PX - males: 106 ± 10 vs 714 ± 14 s in C; females: 102 ± 10 vs 715 ± 14 s in C). At 0.3 mg/kg, neither of these drugs affected NC. Fluoxetine (1-25 mg/kg) also inhibited catalepsy, although the effect was not dose-dependent; no differences were observed between males and females (5 mg/kg, 180 min: males, 185 ± 14 vs 712 ± 14 s in C; females, 169 ± 10 vs 710 ± 19 s in C). For these SSRIs, maximal inhibition of NC was obtained with 5 mg/kg, 180 min after H. These results are consistent with the hypothesis that serotonergic mechanisms modulate nigrostriatal transmission, and suggest that SSRIs are possibly safe in depressive PD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potentiometric sensors are very attractive tools for chemical analysis because of their simplicity, low power consumption and low cost. They are extensively used in clinical diagnostics and in environmental monitoring. Modern applications of both fields require improvements in the conventional construction and in the performance of the potentiometric sensors, as the trends are towards portable, on-site diagnostics and autonomous sensing in remote locations. The aim of this PhD work was to improve some of the sensor properties that currently hamper the implementation of the potentiometric sensors in modern applications. The first part of the work was concentrated on the development of a solid-state reference electrode (RE) compatible with already existing solid-contact ion-selective electrodes (ISE), both of which are needed for all-solid-state potentiometric sensing systems. A poly(vinyl chloride) membrane doped with a moderately lipophilic salt, tetrabutylammonium-tetrabutylborate (TBA-TBB), was found to show a satisfactory stability of potential in sample solutions with different concentrations. Its response time was nevertheless slow, as it required several minutes to reach the equilibrium. The TBA-TBB membrane RE worked well together with solid-state ISEs in several different situations and on different substrates enabling a miniature design. Solid contacts (SC) that mediate the ion-to-electron transduction are crucial components of well-functioning potentiometric sensors. This transduction process converting the ionic conduction of an ion-selective membrane to the electronic conduction in the circuit was studied with the help of electrochemical impedance spectroscopy (EIS). The solid contacts studied were (i) the conducting polymer (CP) poly(3,4-ethylienedioxythiophene) (PEDOT) and (ii) a carbon cloth having a high surface area. The PEDOT films were doped with a large immobile anion poly(styrene sulfonate) (PSS-) or with a small mobile anion Cl-. As could be expected, the studied PEDOT solid-contact mediated the ion-toelectron transduction more efficiently than the bare glassy carbon substrate, onto which they were electropolymerized, while the impedance of the PEDOT films depended on the mobility of the doping ion and on the ions in the electrolyte. The carbon cloth was found to be an even more effective ion-to-electron transducer than the PEDOT films and it also proved to work as a combined electrical conductor and solid contact when covered with an ion-selective membrane or with a TBA-TBB-based reference membrane. The last part of the work was focused on improving the reproducibility and the potential stability of the SC-ISEs, a problem that culminates to the stability of the standard potential E°. It was proven that the E° of a SC-ISE with a conducting polymer as a solid contact could be adjusted by reducing or oxidizing the CP solid contact by applying current pulses or a potential to it, as the redox state of the CP solid-contact influences the overall potential of the ISE. The slope and thus the analytical performance of the SC-ISEs were retained despite the adjustment of the E°. The shortcircuiting of the SC-ISE with a conventional large-capacitance RE was found to be a feasible instrument-free method to control the E°. With this method, the driving force for the oxidation/reduction of the CP was the potential difference between the RE and the SC-ISE, and the position of the adjusted potential could be controlled by choosing a suitable concentration for the short-circuiting electrolyte. The piece-to-piece reproducibility of the adjusted potential was promising, and the day-today reproducibility for a specific sensor was excellent. The instrumentfree approach to control the E° is very attractive considering practical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the clinical efficacy of orally administered valdecoxib and piroxicam for the prevention of pain, trismus and swelling after removal of horizontally and totally intrabony impacted lower third molars. Twenty-five patients were scheduled to undergo removal of symmetrically positioned lower third molars in two separate appointments. Valdecoxib (40 mg) or piroxicam (20 mg) was administered in a double-blind, randomized and crossed manner for 4 days after the surgical procedures. Objective and subjective parameters were recorded for comparison of postoperative courses. Both agents were effective for postoperative pain relief (N = 19). There was a similar mouth opening at suture removal compared with the preoperative values (86.14 ± 4.36 and 93.12 ± 3.70% of the initial measure for valdecoxib and piroxicam, respectively; ANOVA). There was no significant difference regarding the total amount of rescue medication taken by the patients treated with valdecoxib or piroxicam (173.08 ± 91.21 and 461.54 ± 199.85 mg, respectively; Wilcoxon test). There were no significant differences concerning the swelling observed on the second postoperative day compared to baseline measures (6.15 ± 1.84 and 8.46 ± 2.04 mm for valdecoxib and piroxicam, respectively; ANOVA) or on the seventh postoperative day (1.69 ± 1.61 and 2.23 ± 2.09 mm for valdecoxib and piroxicam, respectively; ANOVA). The cyclooxygenase-2 selective inhibitor valdecoxib is as effective as the non-selective cyclooxygenase inhibitor piroxicam for pain, trismus and swelling control after removal of horizontally and totally intrabony impacted lower third molars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the effectiveness of attribution retraining group therapy (ARGT) with selective serotonin reuptake inhibitors (SSRIs) in the treatment of major depressive disorder (MDD), generalized anxiety disorder (GAD), and obsessive-compulsive disorder (OCD). Subjects were sequentially recruited and randomized into two groups, one receiving ARGT (n = 63) and the other SSRIs (n = 66) for 8 weeks. Fifty-four ARGT outpatients with MDD (n = 19), GAD (n = 19), and OCD (n = 16) and 55 SSRI outpatients with MDD (n = 19), GAD (n = 19), and OCD (n = 17) completed the study. All subjects were assessed using the Hamilton Depression Scale and Hamilton Anxiety Scale before and after treatment. The 10-item Yale-Brown Obsessive Compulsive Scale was employed only for OCD subjects. Plasma levels of serotonin, norepinephrine, cortisol, and adrenocorticotropic hormone were also measured at baseline and 8 weeks after completion of treatment. Symptom scores were significantly reduced (P < 0.001) in both the ARGT and SSRI groups at the end of treatment. However, MDD, GAD and OCD patients in the ARGT group had significantly lower plasma cortisol concentrations compared to baseline (P < 0.05), whereas MDD and OCD patients receiving SSRIs showed significantly increased plasma levels of serotonin (P < 0.05). These findings suggest that ARGT may modulate plasma cortisol levels and affect the hypothalamus-pituitary-adrenal axis as opposed to SSRIs, which may up-regulate plasma serotonin levels via a different pathway to produce an overall improvement in the clinical condition of the patients.