972 resultados para SILICON HETEROJUNCTION
Resumo:
In the last years technologies related to photovoltaic energy have rapidly developed and the interest on renewable energy power source substantially increased. In particular, cost reduction and appropriate feed-in tariff contributed to the increase of photovoltaic installation, especially in Germany and Italy. However, for several technologies, the observed experimental efficiency of solar cells is still far from the theoretical maximum efficiency, and thus there is still room for improvement. In this framework the research and development of new materials and new solar devices is mandatory. In this thesis the morphological and optical properties of thin films of nanocrystalline silicon oxynitride (nc-SiON) have been investigated. This material has been studied in view of its application in Si based heterojunction solar cells (HIT). Actually, a-Si:H is used now in these cells as emitter layer. Amorphous SiO_x N_y has already shown excellent properties, such as: electrical conductivity, optical energy gap and transmittance higher than the ones of a-Si:H. Nc-SiO_x N_y has never been investigated up to now, but its properties can surpass the ones of amorphous SiON. The films of nc-SiON have been deposited at the University of Konstanz (Germany). The properties of these films have been studied using of atomic force microscopy and optical spectroscopy methods. This material is highly complex as it is made by different coexisting phases. The main purpose of this thesis is the development of methods for the analyses of morphological and optical properties of nc-SiON and the study of the reliability of those methods to the measurement of the characteristics of these silicon films. The collected data will be used to understand the evolution of the properties of nc-SiON, as a function of the deposition parameters. The results here obtained show that nc-SiON films have better properties with respect to both a-Si:H and a-SiON, i. e. higher optical band-gap and transmittance. In addition, the analysis of the variation of the observed properties as a function of the deposition parameters allows for the optimization of deposition conditions for obtaining optimal efficiency of a HIT cell with SiON layer.
Resumo:
Nel presente lavoro espongo i risultati degli esperimenti svolti durante la mia internship all’Institut des NanoSciences de Paris (INSP), presso l’Università Pierre et Marie Curie (Paris VI), nel team "Phisico-Chimie et Dynamique des Surfaces", sotto la supervisione del Dott. Geoffroy Prévot. L’elaborato è stato redatto e in- tegrato sotto la guida del Dott. Pasquini, del dipartimento di Fisica e Astronomia dell’Università di Bologna. La tesi s’inserisce nel campo di ricerca del silicene, i.e. l’allotropo bidimensionale del silicio. Il cosidetto free-standing silicene è stato predetto teoricamente nel 2009 utilizzando calcoli di Density Functional Theory, e da allora ha stimolato un’intensa ricerca per la sua realizzazione sperimentale. La sua struttura elettronica lo rende particolarmente adatto per eventuali appli- cazioni tecnologiche e sperimentali, mentre lo studio delle sue proprietà è di grande interesse per la scienza di base. Nel capitolo 1 presento innanzitutto la struttura del silicene e le proprietà previste dagli studi pubblicati nella letteratura scientifica. In seguito espongo alcuni dei risultati sperimentali ottenuti negli ultimi anni, in quanto utili per un paragone con i risultati ottenuti durante l’internship. Nel capitolo 2 presento le tecniche sperimentali che ho utilizzato per effettuare le misure. Molto tempo è stato investito per ottenere una certa dimistichezza con gli apparati in modo da svolgere gli esperimenti in maniera autonoma. Il capitolo 3 è dedicato alla discussione e analisi dei risultati delle misure, che sono presentati in relazione ad alcune considerazioni esposte nel primo capitolo. Infine le conclusioni riassumono brevemente quanto ottenuto dall’analisi dati. A partire da queste considerazioni propongo alcuni esperimenti che potrebbero ulteriormente contribuire alla ricerca del silicene. I risultati ottenuti su Ag(111) sono contenuti in un articolo accettato da Physical Review B.
Resumo:
The primary goal of this work is related to the extension of an analytic electro-optical model. It will be used to describe single-junction crystalline silicon solar cells and a silicon/perovskite tandem solar cell in the presence of light-trapping in order to calculate efficiency limits for such a device. In particular, our tandem system is composed by crystalline silicon and a perovskite structure material: metilammoniumleadtriiodide (MALI). Perovskite are among the most convenient materials for photovoltaics thanks to their reduced cost and increasing efficiencies. Solar cell efficiencies of devices using these materials increased from 3.8% in 2009 to a certified 20.1% in 2014 making this the fastest-advancing solar technology to date. Moreover, texturization increases the amount of light which can be absorbed through an active layer. Using Green’s formalism it is possible to calculate the photogeneration rate of a single-layer structure with Lambertian light trapping analytically. In this work we go further: we study the optical coupling between the two cells in our tandem system in order to calculate the photogeneration rate of the whole structure. We also model the electronic part of such a device by considering the perovskite top cell as an ideal diode and solving the drift-diffusion equation with appropriate boundary conditions for the silicon bottom cell. We have a four terminal structure, so our tandem system is totally unconstrained. Then we calculate the efficiency limits of our tandem including several recombination mechanisms such as Auger, SRH and surface recombination. We focus also on the dependence of the results on the band gap of the perovskite and we calculare an optimal band gap to optimize the tandem efficiency. The whole work has been continuously supported by a numerical validation of out analytic model against Silvaco ATLAS which solves drift-diffusion equations using a finite elements method. Our goal is to develop a simpler and cheaper, but accurate model to study such devices.
Resumo:
L’oggetto della presente tesi di laurea magistrale consiste nello studio di polimeri coniugati nella catena principale, per una loro applicazione come materiali fotoattivi in celle fotovoltaiche. In particolare, sono stati sintetizzati e caratterizzati politiofeni tioalchil sostituiti, funzionalizzati in posizione 3-3' con catene alchiliche di diversa lunghezza e grado di ramificazione (tra cui una chirale), al fine di studiarne l'effetto sulle proprietà ottiche ed elettriche del materiale. I polimeri ottenuti sono stati caratterizzati mediante tecniche spettroscopiche (1H-NMR, UV-PL), cromatografia a permeazione su gel (GPC), analisi termiche (DSC, TGA) e misure elettrochimiche (voltammetria ciclica). Il comportamento chiro-ottico del campione chirale è stato inoltre valutato tramite misure di dicroismo circolare. Si è infine testata l’efficienza delle celle fotovoltaiche ottenute utilizzando i polimeri sintetizzati come materiale fotoattivo.
Resumo:
The synthesis, radiolabeling, and initial evaluation of new silicon-fluoride acceptor (SiFA) derivatized octreotate derivatives is reported. So far, the main drawback of the SiFA technology for the synthesis of PET-radiotracers is the high lipophilicity of the resulting radiopharmaceutical. Consequently, we synthesized new SiFA-octreotate analogues derivatized with Fmoc-NH-PEG-COOH, Fmoc-Asn(Ac?AcNH-?-Glc)-OH, and SiFA-aldehyde (SIFA-A). The substances could be labeled in high yields (38 ± 4%) and specific activities between 29 and 56 GBq/?mol in short synthesis times of less than 30 min (e.o.b.). The in vitro evaluation of the synthesized conjugates displayed a sst2 receptor affinity (IC?? = 3.3 ± 0.3 nM) comparable to that of somatostatin-28. As a measure of lipophilicity of the conjugates, the log P(ow) was determined and found to be 0.96 for SiFA-Asn(AcNH-?-Glc)-PEG-Tyr³-octreotate and 1.23 for SiFA-Asn(AcNH-?-Glc)-Tyr³-octreotate, which is considerably lower than for SiFA-Tyr³-octreotate (log P(ow) = 1.59). The initial in vivo evaluation of [¹?F]SiFA-Asn(AcNH-?-Glc)-PEG-Tyr³-octreotate revealed a significant uptake of radiotracer in the tumor tissue of AR42J tumor-bearing nude mice of 7.7% ID/g tissue weight. These results show that the high lipophilicity of the SiFA moiety can be compensated by applying hydrophilic moieties. Using this approach, a tumor-affine SiFA-containing peptide could successfully be used for receptor imaging for the first time in this proof of concept study.
Resumo:
BACKGROUND: Recently, several cases of symptomatic and/or electrically detectable intracardiac inside-out abrasions in silicon-coated Riata® and Riata® ST leads have been described. However, the prevalence in asymptomatic patients with unremarkable implantable cardioverter defibrillator (ICD) interrogation is unknown. The aim of this study was to determine the prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads. METHODS: All 52 patients with an active silicone-coated Riata® and Riata® ST lead followed up in our outpatient clinic were scheduled for a premature ICD interrogation and a biplane chest radiograph. When an intracardiac inside-out abrasion was suspected, this finding was confirmed by fluoroscopy. RESULTS: Mean time since implantation was 71±18months. An intracardiac inside-out abrasion was confirmed by fluoroscopy in 6 patients (11.5%). Mean time from lead implantation to detection of intracardiac inside-out abrasion was 79±14months. In all patients with an intracardiac inside-out abrasion, ICD interrogation showed normal and stable electrical parameters. Retrospectively, in 4 of these 6 patients, a coronary angiography performed 25±18months before diagnosis of intracardiac inside-out abrasion already showed the defect. Despite undetected intracardiac inside-out abrasion, 2 of these 4 patients experienced adequate antitachycardia pacing and ICD-shocks. ICD leads were replaced in all 6 patients. CONCLUSIONS: The prevalence of asymptomatic intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads is higher than 10% when assessed by fluoroscopy, and most intracardiac inside-out abrasions are not detectable by ICD interrogation.
Resumo:
BACKGROUND: Following vitrectomy for PVR-associated retinal detachment, placement of an encircling band, filling with silicone oil (SO) and successful retinal reattachment, a recurrence of PVR can develop. Retinal redetachment after SO removal is usually due to secondary or residual PVR. We wanted to ascertain whether the anatomical and functional outcomes of surgery in patients with a reattached retina and recurrent PVR can be improved by delaying the removal of SO. PATIENTS AND METHODS: 112 consecutive patients with PVR-associated retinal detachment who had undergone vitrectomy with SO filling, were monitored for at least 6 months after SO removal. Prior to SO removal, the retina posterior to the encircling band had to be completely reattached. Patients who developed PVR after SO filling were divided into two groups according to the duration of SO retention: 12 - 18 months (group 2: n = 48); > 18 months (group 3: n = 21). Individuals without PVR recurrence after SO filling and in whom the SO was consequently removed within 4 - 12 months served as control (group 1: n = 43). Anatomical success, intraocular pressure (IOP) and best-corrected visual acuity (BCVA) served as the primary clinical outcome parameters. RESULTS: Six months after SO removal, the anatomical success rates (86.3 %, 88.8 % and 84.6 %, in groups 1, 2 and 3, respectively; log rank = 0.794) and the BCVAs (p = 0.861) were comparable in the three groups. Mean IOP (p = 0.766), and the frequency of complications such as PVR recurrence (p = 0.936), bullous keratopathy (p = 0.981) and macular pucker (p = 0.943) were likewise similar. Patients in whom SO was retained for more than 18 months had the highest IOPs and required the heaviest dosage with anti-glaucoma drugs. CONCLUSIONS: In patients who develop a recurrence of PVR after vitrectomy and SO filling the surgeon can observe and treat retinal changes for up to 18 months without impairing the anatomical and functional outcomes. The retention of SO for more than 18 months does not improve the anatomical outcome. However, it can impair the functional outcome by precipitating the development of a persisting secondary glaucoma.
Resumo:
The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.