614 resultados para Roof gutters


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this project, Stora Enso’s newly developed building system has been further developed to allow building to the Swedish passive house standard for the Swedish climate. The building system is based on a building framework of CLT (Cross laminated timber) boards. The concept has been tested on a small test building. The experience gained from this test building has also been used for planning a larger building (two storeys with the option of a third storey) with passive house standard with this building system. The main conclusions from the project are:  It is possible to build airtight buildings with this technique without using traditional vapour barriers. Initial measurements show that this can be done without reaching critical humidity levels in the walls and roof, at least where wood fibre insulation is used, as this has a greater capacity for storing and evening out the moisture than mineral wool. However, the test building has so far not been exposed to internal generation of moisture (added moisture from showers, food preparation etc.). This needs to be investigated and this will be done during the winter 2013-14.  A new fixing method for doors and windows has been tested without traditional fibre filling between them and the CLT panel. The door or window is pressed directly on to the CLT panel instead, with an expandable sealing strip between them. This has been proved to be successful.  The air tightness between the CLT panels is achieved with expandable sealing strips between the panels. The position of the sealing strips is important, both for the air tightness itself and to allow rational assembly.  Recurrent air tightness measurements show that the air tightness decreased somewhat during the first six months, but not to such an extent that the passive house criteria were not fulfilled. The reason for the decreased air tightness is not clear, but can be due to small movements in the CLT construction and also to the sealing strips being affected by changing outdoor temperatures.  Long term measurements (at least two years) have to be carried out before more reliable conclusions can be drawn regarding the long term effect of the construction on air tightness and humidity in the walls.  An economic analysis comparing using a concrete frame or the studied CLT frame for a three storey building shows that it is probably more expensive to build with CLT. For buildings higher than three floors, the CLT frame has economic advantages, mainly because of the shorter building time compared to using concrete for the frame. In this analysis, no considerations have been taken to differences in the influence on the environment or the global climate between the two construction methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis evaluates different sites for a weather measurement system and a suitable PV- simulation for University of Surabaya (UBAYA) in Indonesia/Java. The weather station is able to monitor all common weather phenomena including solar insolation. It is planned to use the data for scientific and educational purposes in the renewable energy studies. During evaluation and installation it falls into place that official specifications from global meteorological organizations could not be meet for some sensors caused by the conditions of UBAYA campus. After arranging the hardware the weather at the site was monitored for period of time. A comparison with different official sources from ground based and satellite bases measurements showed differences in wind and solar radiation. In some cases the monthly average solar insolation was deviating 42 % for satellite-based measurements. For the ground based it was less than 10 %. The average wind speed has a difference of 33 % compared to a source, which evaluated the wind power in Surabaya. The wind direction shows instabilities towards east compared with data from local weather station at the airport. PSET has the chance to get some investments to investigate photovoltaic on there own roof. With several simulations a suitable roof direction and the yearly and monthly outputs are shown. With a 7.7 kWpeak PV installation with the latest crystalline technology on the market 8.82 MWh/year could be achieved with weather data from 2012. Thin film technology could increase the value up to 9.13 MWh/year. However, the roofs have enough area to install PV. Finally the low price of electricity in Indonesia makes it not worth to feed in the energy into the public grid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Allt hårdare lagkrav gör att det är svårt att energieffektivisera befintliga byggnader utan att förändra deras utseende. Syftet med examensarbetet är att utreda hur stor energieffektivisering, för tre befintliga småhus uppförda under 1900-talet, som är möjlig att uppnå genom förbättring av byggnadernas klimatskal, det vill säga tak, väggar, golv, fönster och dörrar, utan att förvanska byggnadernas utseende och samtidigt bevara deras kulturhistoriska värden. Arbetet bestod av en förstudie där tre byggnader identifierades, ett undersökningsskede där information om byggnaderna togs fram och ett slutsatsskede där energibesparande åtgärdsförslag togs fram och utvärderades. Byggnader som var goda representanter för sin tid och stil söktes. Byggnader från 1910-talet, 1930-talet och 1970-talet, lokaliserades. Sedan gjordes det fallstudier med intervjuer och inventeringar. För att utreda byggnadens klimatskal utfördes u-värdesberäkningar och energiberäkningar av befintliga byggander och byggnader baserade på föreslagna åtgärdsförslag. Ingen av byggnaderna nådde efter föreslagna åtgärder ner till passivhuskravet 59 kWh/år/m2 Atemp eller BBR-kravet 110 kWh/år/m2 Atemp för en byggnads specifika energianvändning. Den största möjliga energieffektivisering för de tre byggnaderna uppförda under 1900-talet, som är möjlig att uppnå utan att förvanska byggnadernas utseende och samtidigt bevara deras kulturhistoriska värden är 13,0 kWh/år/m2 Atemp, 49,7 kWh/år/m2 Atemp respektive 64,8 kWh/år/m2 Atemp. Slutsatser från arbetet är att byggnader från 1910-tal kan åtgärdas genom att isolera fönstren, sätta dit en extra dörr på insidan av ytterdörren samt tilläggsisolera snedtaket. Byggnader från 1930-tal kan åtgärdas genom att isolera fönstren med en isolerruta på insidan av fönstret och dörrarna med en extra dörr på insidan av ytterdörren. Byggnader från 1970-tal kan åtgärda fönstren genom att byta ut dem till energifönster, ingen åtgärd för golvet men fasaden isoleras utvändigt med vakuumisolering. Byggnaden från 1970-talet klarade sig bäst i jämförelsen eftersom den var i autentiskt skick från början vilket gjorde att förbättringen blev större än för till exempel byggnaden från 1910-talet som redan var ombyggd innan åtgärder föreslogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increasing energy use has caused many environmental problems including global warming. Energy use is growing rapidly in developing countries and surprisingly a remarkable portion of it is associated with consumed energy to keep the temperature comfortable inside the buildings. Therefore, identifying renewable technologies for cooling and heating is essential. This study introduced applications of steel sheets integrated into the buildings to save energy based on existing technologies. In addition, the proposed application was found to have a considerable chance of market success. Also, satisfying energy needs for space heating and cooling in a single room by using one of the selected applications in different Köppen climate classes was investigated to estimate which climates have a proper potential for benefiting from the application. This study included three independent parts and the results related to each part have been used in the next part. The first part recognizes six different technologies through literature review including Cool Roof, Solar Chimney, Steel Cladding of Building, Night Radiative Cooling, Elastomer Metal Absorber, and Solar Distillation. The second part evaluated the application of different technologies by gathering the experts’ ideas via performing a Delphi method. The results showed that the Solar Chimney has a proper chance for the market. The third part simulated both a solar chimney and a solar chimney with evaporation which were connected to a single well insulated room with a considerable thermal mass. The combination was simulated as a system to estimate the possibility of satisfying cooling needs and heating needs in different climate classes. A Trombe-wall was selected as a sample design for the Solar Chimney and was simulated in different climates. The results implied that the solar chimney had the capability of reducing the cooling needs more than 25% in all of the studied locations and 100% in some locations with dry or temperate climate such as Mashhad, Madrid, and Istanbul. It was also observed that the heating needs were satisfied more than 50% in all of the studied locations, even for the continental climate such as Stockholm and 100% in most locations with a dry climate. Therefore, the Solar Chimney reduces energy use, saves environment resources, and it is a cost effective application. Furthermore, it saves the equipment costs in many locations. All the results mentioned above make the solar chimney a very practical and attractive tool for a wide range of climates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

o estado de Santa Catarina é responsável por 50% da produção nacional de carvão. A produção de carvão nas carboníferas da região de Criciúma - SC ocorre por meio de mineração subterrânea, utilizando o método de câmaras e pilares. Os sistemas de suportes de teto em mina subterrânea de carvão têm apresentado notáveis mudanças no seu desenvolvimento ao longo da história. Para tanto, atualmente existe uma ampla gama de tipos de suportes ou mecanismos de sustentação. O teto das minas de carvão é composto de rochas sedimentares as quais variam em espessura e em extensão lateral. Além disso, essas rochas apresentam resistência variada e características estruturais distintas. Contudo, o padrão de sustentação geralmente é o mesmo, independente da qualidade do maciço. Esse estudo buscou verificar se o padrão de suporte de teto atualmente empregado na Mina Barro Branco, apresenta-se adequado às distintas condições geológicas e geomecânicas do maciço rochoso que compõe o teto imediato da mina. Para este fim, o teto imediato foi avaliado ao longo de várias seções da mina e as informações foram usadas para classificar o maciço em zonas de acordo com o sistema Coal Mine Roof Rating (CMRR) proposto pelo U.S. Bureauof Minesem 1994. Diferentes índices de CMRRforam identificados e então considerados para definir a largura máxima nos cruzamentos, o comprimentoe a capacidadede carregamento dos parafusos de teto. Estatísticas da mina revelam que caimentos de teto acorreram quando as dimensões e o padrão de suporte empregado estão aquém do mínimo recomendado pelo CMRR. Esta metodologiaprovou ser adequada, minimizando os riscosde ruptura de teto e predizendoo tipo de suporte mais apropriadoa ser empregado às várias zonas dentro do depósito. Estes resultados preliminares devem ser validados em diferentes locais da mina e ajustes secundários devem ser implementados no método principalmente devido ao uso de explosivos no desmonte das rochas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Social exclusion is a relatively recent term, whose creation is attributed to René Lenoir(Lenoir, 1974). Its concept covers a remarkably wide range of social and economic problems, and can be triggered for various reasons: mentally and physically handicapped, abused children, delinquents, multi-problem households, asocial people, and other social “misfits” (Silver, 1995, pp. 63; Foucault, 1992). With an increasingly multi-cultural population, cultural and social inequalities rapidly ascend, bringing with them the need for educational restructuring. We are living in an evermore diverse world, and children need to be educated to be receptive to the different types of people around them, especially considering social and cultural aspects. It is with these goals that inclusive education has seen an increased trend in today’s academic environment, reminding us that even though children may be taught under the same roof, discriminatory practices might still happen. There are, however, a number of developed tools to assess the various dimensions of social networks. These are mostly based on questionnaires and interviews, which tend to be fastidious and don’t allow for longitudinal, large scale measurement. This thesis introduces BlueFriends, a Bluetooth-based measurement tool for social inclusion/exclusion on elementary school classes. The main goals behind the development of this tool were a) understanding how exclusion manifests in students’ behaviors, and b) motivating pro-social behaviors on children through the use of a persuasive technology. BlueFriends is a distributed application, comprised by an application running on several smartphones, a web-hosted database and a computer providing a visual representation of the data collected on a TV screen, attempting to influence children behaviors. The application makes use of the Bluetooth device present on each phone to continuously sample the RSSI (Received Signal Strength Indication) from other phones, storing the data locally on each phone. All of the stored data is collected, processed and then inserted into the database at the end of each day. At the beginning of each recess, children are reminded of how their behaviors affect others with the help of a visual display, which consists of interactions between dogs. This display illustrates every child’s best friends, as well as which colleagues they don’t interact with as much. Several tips encouraging social interaction and inclusiveness are displayed, inspiring children to change their behaviors towards the colleagues they spend less time with. This thesis documents the process of designing, deploying and analyzing the results of two field studies. On the first study, we assess how the current developed tools are inferior to our measuring tool by deploying a measurement only study, aimed at perceiving how much information can be obtained by the BlueFriends application and attempting to understand how exclusion manifests itself in the school environment. On the second study, we pile on the previous to try and motivate pro-social behaviors on students, with the use of visual cues and recommendations. Ultimately, we confirm that our measurement tool’s results were satisfying towards measuring and changing children’s behaviors, and conclude with our thoughts on possible future work, suggesting a number of possible extensions and improvements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MELO, Maxymme Mendes de ; PINHEIRO, Andrea Santos ; NASCIMENTO, R. M. ; MARTINELLI, Antonio Eduardo ; DUTRA, Ricardo Peixoto Suassuna ; MELO, Marcus Antônio de Freitas . Análise microestrutural de misturas cerâmicas de grês Porcelanato com adição de chamote de telhas cerâmicas. Cerâmica (São Paulo. Impresso), v. 55, p. 356-364, 2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The WTP produce many kinds of residue on your treatment stages, but the sludge is the more problematic from the final disposition point view. The actual rate of residue production deriving from technological evolution and the crescent population needs prevents the subtle equilibrium generation between consumption and recycling/reuse, creating problems of pollution resulting from inappropriate management of residues. Thus, is necessary achieve a new equilibrium between the grow from raw materials and energy and the residue generation. This equilibrium should be achieved by technical and economic feasibility of environmental supported models through recycling and reuse. The red ceramic industry stand out in residue absorption question as raw material due their clay mass heterogeneity, constituted by clay minerals and non-clay minerals with wide mineralogical variation, allowing residue inclusion which act like plastic or non-plastic materials, contributing to retain heavy metals contained in residues in the vitreous mass formed during the burning of the ceramic bodies. This work propose the study of the influence of incorporation of 25 wt.% sludge from wastewater treatment plant, according preliminary results, in the mass to produce ceramic bodies. The raw materials was characterized through chemical composition analyses by XRF, mineralogical analyses by XRD, thermal analyses by TG and DTA, Atterberg limits and thermodilatometry. Subsequently was composed the mass with 75 wt.% of clay and 25 wt.% of dried wastewater sludge from UFRN WWTP. Samples with 6,0 x 2,0 x 0,5 cm was produced with unidirectional compacting under pressure of 20MPa and burned in temperatures between 950 and 1,200ºC. After fired, the ceramic bodies have been submitted to physical and mechanical analyses through the measure of firing shrinkage, water absorption, density, apparent porosity and flexural strength; crystallographic analyses through XRD and microstructure analyses by SEM. The technological properties obtained was satisfactory to production of roof tiles with 25 wt.% at 1,200 ºC, but the production of others products at lower temperatures was not feasible

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi avaliar o crescimento e a produção de Anthurium andraeanum 'Apalai' submetido a diferentes intensidades de desfolha no Vale do Ribeira, SP. Foram utilizadas mudas micropropagadas dessa espécie, as quais foram plantadas em canteiros construídos sob telado coberto com tela de náilon preta, com malha que proporciona 70% de sombreamento, no espaçamento 0,40x0,40m. O experimento foi conduzido em delineamento de blocos casualizados em parcelas subdivididas, com dezesseis repetições. O efeito da desfolha foi avaliado na parcela e o efeito do tempo após a desfolha na subparcela. As diferentes intensidades de desfolha consistiram em plantas com três, quatro e cinco folhas e plantas sem desfolha, e o tempo após a desfolha, as avaliações realizadas em 2006 e 2007. Ocorreu um aumento na área das folhas individuais em plantas mantidas com quatro e cinco folhas, proporcional à intensidade de desfolha, que pode ser relacionado a uma tentativa de compensação da área foliar perdida. A desfolha com a manutenção de três, quatro ou cinco folhas em plantas de antúrio 'Apalai' é prejudicial para o seu crescimento e produção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dentre os materiais de construção utilizados nas instalações rurais, merecem destaque as coberturas, pois são grandes responsáveis pelo conforto térmico, influenciando no balanço térmico no interior das instalações. Este trabalho objetivou avaliar a influência das coberturas sobre a entalpia (H), Carga Térmica Radiante (CTR) e no Índice de Temperatura de Globo Negro e Umidade (ITGU), em abrigos individuais para bezerros leiteiros. O delineamento foi o inteiramente casualizado com três tratamentos: Z - telha de zinco; CA - telha de cimento amianto, e CAB - telha de cimento amianto pintada de branco na face superior. As médias foram comparadas pelo teste de Scott Knott, a 1% de probabilidade. Os resultados mostraram que não houve diferença estatística entre os tratamentos (P<0,01) e o ambiente externo, para a H. Para a CTR, houve diferença estatística entre todos os tratamentos, em que CAB demonstrou menor CTR, 489,28 W m-², seguido do tratamento CA, 506,72 W m-², e Z com maior valor de CTR, 523,55 W m-². Para o ITGU, observaram-se menores valores para CAB (76,8) e CA (77,4), diferindo-se, significativamente do Z, que obteve maior valor (81,6). As telhas com pintura branca em sua face superior promoveram menor CTR e menor ITGU, favorecendo o ambiente térmico da instalação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o efeito do uso de isolante térmico de telhado instalado como forro sob a cobertura no desempenho de frangos alojados em diferentes densidades (10, 16 e 22 aves/m²) e nas características da cama de aviário em galpão convencional. O experimento foi realizado durante o verão, utilizando 3328 aves da linhagem Hubbard, distribuídas em um delineamento inteiramente casualizado, em um esquema fatorial 3x2 (densidade e sexo), com quatro repetições dentro de cada ambiente. Para a comparação dos ambientes, utilizou-se a análise conjunta. Durante o período experimental, registraram-se dados de temperatura ambiente em vários pontos do galpão e em diversos horários, umidade relativa e carga térmica radiante. O teor de nitrogênio e matéria seca e a temperatura da cama foram determinados. No ambiente com isolante térmico, as temperaturas ambientais médias e a amplitude térmica diária foram menores e a umidade relativa do ar, maior. O desempenho das aves foi melhor no ambiente com isolante térmico, no qual as aves tiveram maior consumo de ração, maior ganho de peso, melhor conversão alimentar, menor mortalidade e maior produção por área. A temperatura retal das aves do ambiente sem isolante térmico foi mais elevada. À medida que se elevou a densidade, a mortalidade aumentou, porém a produção por área foi maior. O uso do isolante não influenciou a produção de cama, mas diminuiu a porcentagem de nitrogênio na cama. Com o aumento da densidade, a produção de cama elevou-se, pelo maior volume de excretas, mas não influenciou sua porcentagem de nitrogênio. O uso do isolante térmico permitiu aumento da densidade de criação dos frangos.