985 resultados para Rapid slide agglutination test


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The diagnosis of dengue and the differentiation between primary and secondary infections are important for monitoring the spread of the epidemic and identifying the risk of severe forms of the disease. The detection of immunoglobulin (Ig)M and IgG antibodies is the main technique for the laboratory diagnosis of dengue. The present study assessed the application of a rapid test for dengue concerning detection of new cases, reinfection recognition, and estimation of the epidemic attack rate. METHODS: This was a retrospective, cross-sectional, descriptive study on dengue using the Fortaleza Health Municipal Department database. The results from 1,530 tested samples, from 2005-2006, were compared with data from epidemiological studies of dengue outbreaks in 1996, 2003, and 2010. RESULTS: The rapid test confirmed 52% recent infections in the tested patients with clinical suspicion of dengue: 40% detected using IgM and 12% of new cases using IgG in the non-reactive IgM results. The positive IgM plus negative IgG (IgM+ plus IgG-) results showed that 38% of those patients had a recent primary dengue infection, while the positive IgG plus either positive or negative IgM (IgG+ plus IgM+/-) results indicated that 62% had dengue for at least a second time (recent secondary infections). This proportion of reinfections permitted us to estimate the attack rate as >62% of the population sample. CONCLUSIONS: The rapid test for dengue has enhanced our ability to detect new infections and to characterize them into primary and secondary infections, permitting the estimation of the minimal attack rate for a population during an outbreak.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The availability of a rapid diagnostic test for malaria (RDTm) allows accurate diagnosis at all levels of health facilities. The objective of the present study was to evaluate the safety of withholding antimalarials in febrile children who have a negative test result. METHODS: We conducted a prospective 2-arm longitudinal study in areas of Tanzania that are moderately and highly endemic for malaria. Children with a history of fever were managed routinely by resident clinicians of 2 health facilities, except that no antimalarials were prescribed if the RDTm result was negative. Children were followed up at home on day 7. The main outcome was the occurrence of complications in children with negative RDTm results; children with positive RDTm results were followed up for the same outcomes for indirect comparison. RESULTS: One thousand children (median age, 24 months) were recruited. Six hundred three children (60%) had a negative RDTm result. Five hundred seventy-three (97%) of these children were cured on day 7. Forty-nine (8%) of the children with negative RDTm results spontaneously visited the dispensary before day 7, compared with 10 (3%) of the children with positive RDTm results. All children who had negative initial results had negative results again when they were tested either at spontaneous attendance or on day 7 because they were not cured clinically, except for 3 who gave positive results on days 2, 4, and 7 respectively but who did not experience any complication. Four children who had negative initial results were admitted to the hospital subsequently, all with negative results for malaria tests upon admission. Two of them died, of causes other than malaria. CONCLUSIONS: Not giving antimalarial drugs in febrile children who had a negative RDTm result was safe, even in an area highly endemic for malaria. Our study provides evidence for treatment recommendations based on parasitological diagnosis in children <5 years old.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A slide micro-immunoenzymatic assay (micro-SIA) to detectantibodies to non-particulate Toxoplasma gondii antigens is described. This assay allows the diagnosis of toxoplasmosis infection in about 1 hr. Twenty-four determinations can be performed per slide. Five hundred ng of antigen and 5 or 10 µl drop of each reactive are necessary per well. The clear contrast of colours obtained for negative and positive sera after the test is finished, allows direct discrimination of the results. However, it is possible to quantify the results of the reaction using a minireader. Sera dilution cutoff value, determined as themost frequent titre for the general population, is 1:100. The toxoplasma micro-SIA correlates well with indirect immunofluorescence (IIF), its sensitivity is atleast three times as much as IIF. The test has an intra and inter assay variation coefficient of 5.46 per cent and of 6.24 per cent respectively. Sera obtained at random from argentinian people were analyzed and a 56 per cent of infection was found. The main features of the Toxoplasma micro-SIA are its simplicity, sensitivity, reproducibility, and the virtual absence of background making it very suitable for screening tests.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Human Immunodeficiency Virus continues to be a pandemic. Spain is one of the European countries with the highest incidence of HIV. Within Catalonia, Spain many projects have been implemented with the intention of improving HIV knowledge and lowering the incidence. HIV knowledge is also known to have a positive effect on lowering stigma and discrimination of the people living with HIV. However, few studies study the distribution of HIV knowledge and its association to HIV status, age, sex, geographical zone of origin and level of education within the same study. Objectives: To identify if HIV knowledge is associated with HIV status, age, sex, geographical zone of origin and level of education. Method: Quantitative, cross-sectional, centre-based study comprising of people receiving an HIV test in Catalonia, Spain. Data will be collected from the 11 HIV Non-Governmental Organisations in Catalonia, Spain. The Brief HIV Knowledge Scale will be used to assess HIV knowledge; information from the HIV test session will be used to assess HIV status, age, sex, geographic zone of origin and level of education. The association between HIV knowledge and the afore mentioned variables will then be calculated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the specificity of a rapid immunochromatographic test that was developed to detect antibodies against the rK39 antigen for the diagnosis of visceral leishmaniasis (VL). This evaluation was performed using sera from patients with a confirmed diagnosis of active cutaneous leishmaniasis. The sera from 272 patients with a confirmed diagnosis of localised cutaneous leishmaniasis (CL) who resided in an area endemic for Leishmania braziliensis in Brazil were obtained before the initiation of antileishmanial treatment. Kalazar Detect(r)(InBios, Seattle, WA) recombinant K39 antigen-based immunochromatographic strips were used according to the manufacturer's instructions. The test results were evaluated independently by two examiners in sequential order. The positive controls for the test included five serum samples from five patients with parasitologically confirmed diagnosis of VL caused by Leishmania infantum in Brazil. Overall, 100% of the samples obtained from patients with CL were negative, confirming the absence of a serological cross-reaction for individuals with cutaneous disease when these patients were evaluated using the rapid test. The lack of a cross-reaction in patients who were infected by parasites of the same genus highlights the specificity of the rK39 antigen for the diagnosis of VL in areas with the sympatric circulation of L. braziliensis and L. infantum.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article presents an improvement to the Kato-Katz (KK) method, making it faster and more efficient for the visualisation of fertile eggs in stool samples. This modified KK method uses sodium acetate formalin as a fixative and reveals the intensity of infection in less than 1 h, reducing the diagnostic time without increasing the cost. This modified method may contribute to future epidemiological studies in both hospitals and the field due to its rapid and precise diagnostic, which allow for immediate treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Clients of street sex workers may be at higher risk for HIV infection than the general population. Furthermore, there is a lack of knowledge regarding HIV testing of clients of sex workers in developed countries. METHOD: This pilot study assessed the feasibility and acceptance of rapid HIV testing by the clients of street-based sex workers in Lausanne, Switzerland. For 5 evenings, clients in cars were stopped by trained field staff for face-to-face interviews focusing on sex-related HIV risk behaviors and HIV testing history. The clients were then offered a free anonymous rapid HIV test in a bus parked nearby. Rapid HIV testing and counselling were performed by experienced nurse practitioners. Clients with reactive tests were offered confirmatory testing, medical evaluation, and care in our HIV clinic. RESULT: We intercepted 144 men, 112 (77.8%) agreed to be interviewed. Among them, 50 (46.6%) had never been tested for HIV. A total of 31 (27.7%) rapid HIV tests were performed, 16 (51.6%) in clients who had not previously been tested. None were reactive. Initially, 19 (16.9%) additional clients agreed to HIV testing but later declined due to the 40-minute queue for testing. CONCLUSION: This pilot study showed that rapid HIV testing in the red light district of Lausanne was feasible, and that the clients of sex workers accepted testing at an unexpectedly high rate. This setting seems particularly appropriate for targeted HIV screening, since more than 40% of the clients had not previously been tested for HIV even though they engaged in sex-related HIV risk behaviour.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Various test methods exist for measuring heat of cement hydration; however, most current methods require expensive equipment, complex testing procedures, and/or extensive time, thus not being suitable for field application. The objectives of this research are to identify, develop, and evaluate a standard test procedure for characterization and quality control of pavement concrete mixtures using a calorimetry technique. This research project has three phases. Phase I was designed to identify the user needs, including performance requirements and precision and bias limits, and to synthesize existing test methods for monitoring the heat of hydration, including device types, configurations, test procedures, measurements, advantages, disadvantages, applications, and accuracy. Phase II was designed to conduct experimental work to evaluate the calorimetry equipment recommended from the Phase I study and to develop a standard test procedure for using the equipment and interpreting the test results. Phase II also includes the development of models and computer programs for prediction of concrete pavement performance based on the characteristics of heat evolution curves. Phase III was designed to study for further development of a much simpler, inexpensive calorimeter for field concrete. In this report, the results from the Phase I study are presented, the plan for the Phase II study is described, and the recommendations for Phase III study are outlined. Phase I has been completed through three major activities: (1) collecting input and advice from the members of the project Technical Working Group (TWG), (2) conducting a literature survey, and (3) performing trials at the CP Tech Center’s research lab. The research results indicate that in addition to predicting maturity/strength, concrete heat evolution test results can also be used for (1) forecasting concrete setting time, (2) specifying curing period, (3) estimating risk of thermal cracking, (4) assessing pavement sawing/finishing time, (5) characterizing cement features, (6) identifying incompatibility of cementitious materials, (7) verifying concrete mix proportions, and (8) selecting materials and/or mix designs for given environmental conditions. Besides concrete materials and mix proportions, the configuration of the calorimeter device, sample size, mixing procedure, and testing environment (temperature) also have significant influences on features of concrete heat evolution process. The research team has found that although various calorimeter tests have been conducted for assorted purposes and the potential uses of calorimeter tests are clear, there is no consensus on how to utilize the heat evolution curves to characterize concrete materials and how to effectively relate the characteristics of heat evolution curves to concrete pavement performance. The goal of the Phase II study is to close these gaps.