The analysis of electromagnetic transients arising in EHV/UHV power networks gives necessary information about the possible stresses on the different network components, which will determine their proper design, limits of operation as well as their pertinent protection strategies. This paper describes the transient analysis of 765 kV EHV transmission system which is a typical expansion in Indian power grid system. Considering various conditions, switching transient and fault transient studies are carried out. A FORTRAN version of EMTP is developed, to study a practical example, then a comparison with the results available in the literature is made.
Resumo:
Introduction of processor based instruments in power systems is resulting in the rapid growth of the measured data volume. The present practice in most of the utilities is to store only some of the important data in a retrievable fashion for a limited period. Subsequently even this data is either deleted or stored in some back up devices. The investigations presented here explore the application of lossless data compression techniques for the purpose of archiving all the operational data - so that they can be put to more effective use. Four arithmetic coding methods suitably modified for handling power system steady state operational data are proposed here. The performance of the proposed methods are evaluated using actual data pertaining to the Southern Regional Grid of India. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
This paper illustrates the application of a new technique, based on Support Vector Clustering (SVC) for the direct identification of coherent synchronous generators in a large interconnected Multi-Machine Power Systems. The clustering is based on coherency measures, obtained from the time domain responses of the generators following system disturbances. The proposed clustering algorithm could be integrated into a wide-area measurement system that enables fast identification of coherent clusters of generators for the construction of dynamic equivalent models. An application of the proposed method is demonstrated on a practical 15 generators 72-bus system, an equivalent of Indian Southern grid in an attempt to show the effectiveness of this clustering approach. The effects of short circuit fault locations on coherency are also investigated.
Resumo:
This paper primarily intends to develop a GIS (geographical information system)-based data mining approach for optimally selecting the locations and determining installed capacities for setting up distributed biomass power generation systems in the context of decentralized energy planning for rural regions. The optimal locations within a cluster of villages are obtained by matching the installed capacity needed with the demand for power, minimizing the cost of transportation of biomass from dispersed sources to power generation system, and cost of distribution of electricity from the power generation system to demand centers or villages. The methodology was validated by using it for developing an optimal plan for implementing distributed biomass-based power systems for meeting the rural electricity needs of Tumkur district in India consisting of 2700 villages. The approach uses a k-medoid clustering algorithm to divide the total region into clusters of villages and locate biomass power generation systems at the medoids. The optimal value of k is determined iteratively by running the algorithm for the entire search space for different values of k along with demand-supply matching constraints. The optimal value of the k is chosen such that it minimizes the total cost of system installation, costs of transportation of biomass, and transmission and distribution. A smaller region, consisting of 293 villages was selected to study the sensitivity of the results to varying demand and supply parameters. The results of clustering are represented on a GIS map for the region.
Resumo:
This study investigates the application of support vector clustering (SVC) for the direct identification of coherent synchronous generators in large interconnected multi-machine power systems. The clustering is based on coherency measure, which indicates the degree of coherency between any pair of generators. The proposed SVC algorithm processes the coherency measure matrix that is formulated using the generator rotor measurements to cluster the coherent generators. The proposed approach is demonstrated on IEEE 10 generator 39-bus system and an equivalent 35 generators, 246-bus system of practical Indian southern grid. The effect of number of data samples and fault locations are also examined for determining the accuracy of the proposed approach. An extended comparison with other clustering techniques is also included, to show the effectiveness of the proposed approach in grouping the data into coherent groups of generators. This effectiveness of the coherent clusters obtained with the proposed approach is compared in terms of a set of clustering validity indicators and in terms of statistical assessment that is based on the coherency degree of a generator pair.
Resumo:
This paper studies the feasibility of utilizing the reactive power of grid-connected variable-speed wind generators to enhance the steady-state voltage stability margin of the system. Allowing wind generators to work at maximum reactive power limit may cause the system to operate near the steady-state stability limit, which is undesirable. This necessitates proper coordination of reactive power output of wind generators with other reactive power controllers in the grid. This paper presents a trust region framework for coordinating reactive output of wind generators-with other reactive sources for voltage stability enhancement. Case studies on 418-bus equivalent system of Indian southern grid indicates the effectiveness of proposed methodology in enhancing the steady-state voltage stability margin.
Resumo:
This paper establishes the design requirements for the development and testing of direct supercritical carbon dioxide (sCO2) solar receivers. Current design considerations are based on the ASME Boiler and Pressure Vessel Code (BPVC). Section I (BPVC) considers typical boilers/superheaters (i.e. fired pressure vessels) which work under a constant low heat flux. Section VIII (BPVC) considers pressure vessels with operating pressures above 15 psig 2 bar] (i.e. unfired pressure vessels). Section III, Division I - Subsection NH (BPVC) considers a more detailed stress calculation, compared to Section I and Section VIII, and requires a creep-fatigue analysis. The main drawback from using the BPVC exclusively is the large safety requirements developed for nuclear power applications. As a result, a new set of requirements is needed to perform detailed thermal-structural analyses of solar thermal receivers subjected to a spatially-varying, high-intensity heat flux. The last design requirements document of this kind was an interim Sandia report developed in 1979 (SAND79-8183), but it only addresses some of the technical challenges in early-stage steam and molten-salt solar receivers but not the use of sCO2 receivers. This paper presents a combination of the ASME BPVC and ASME B31.1 Code modified appropriately to achieve the reliability requirements in sCO(2) solar power systems. There are five main categories in this requirements document: Operation and Safety, Materials and Manufacturing, Instrumentation, Maintenance and Environmental, and General requirements. This paper also includes the modeling guidelines and input parameters required in computational fluid dynamics and structural analyses utilizing ANSYS Fluent, ANSYS Mechanical, and nCode Design Life. The main purpose of this document is to serve as a reference and guideline for design and testing requirements, as well as to address the technical challenges and provide initial parameters for the computational models that will be employed for the development of sCO(2) receivers.
Resumo:
(EuroPES 2009)
Resumo:
The dissertation is concerned with the mathematical study of various network problems. First, three real-world networks are considered: (i) the human brain network (ii) communication networks, (iii) electric power networks. Although these networks perform very different tasks, they share similar mathematical foundations. The high-level goal is to analyze and/or synthesis each of these systems from a “control and optimization” point of view. After studying these three real-world networks, two abstract network problems are also explored, which are motivated by power systems. The first one is “flow optimization over a flow network” and the second one is “nonlinear optimization over a generalized weighted graph”. The results derived in this dissertation are summarized below.
Brain Networks: Neuroimaging data reveals the coordinated activity of spatially distinct brain regions, which may be represented mathematically as a network of nodes (brain regions) and links (interdependencies). To obtain the brain connectivity network, the graphs associated with the correlation matrix and the inverse covariance matrix—describing marginal and conditional dependencies between brain regions—have been proposed in the literature. A question arises as to whether any of these graphs provides useful information about the brain connectivity. Due to the electrical properties of the brain, this problem will be investigated in the context of electrical circuits. First, we consider an electric circuit model and show that the inverse covariance matrix of the node voltages reveals the topology of the circuit. Second, we study the problem of finding the topology of the circuit based on only measurement. In this case, by assuming that the circuit is hidden inside a black box and only the nodal signals are available for measurement, the aim is to find the topology of the circuit when a limited number of samples are available. For this purpose, we deploy the graphical lasso technique to estimate a sparse inverse covariance matrix. It is shown that the graphical lasso may find most of the circuit topology if the exact covariance matrix is well-conditioned. However, it may fail to work well when this matrix is ill-conditioned. To deal with ill-conditioned matrices, we propose a small modification to the graphical lasso algorithm and demonstrate its performance. Finally, the technique developed in this work will be applied to the resting-state fMRI data of a number of healthy subjects.
Communication Networks: Congestion control techniques aim to adjust the transmission rates of competing users in the Internet in such a way that the network resources are shared efficiently. Despite the progress in the analysis and synthesis of the Internet congestion control, almost all existing fluid models of congestion control assume that every link in the path of a flow observes the original source rate. To address this issue, a more accurate model is derived in this work for the behavior of the network under an arbitrary congestion controller, which takes into account of the effect of buffering (queueing) on data flows. Using this model, it is proved that the well-known Internet congestion control algorithms may no longer be stable for the common pricing schemes, unless a sufficient condition is satisfied. It is also shown that these algorithms are guaranteed to be stable if a new pricing mechanism is used.
Electrical Power Networks: Optimal power flow (OPF) has been one of the most studied problems for power systems since its introduction by Carpentier in 1962. This problem is concerned with finding an optimal operating point of a power network minimizing the total power generation cost subject to network and physical constraints. It is well known that OPF is computationally hard to solve due to the nonlinear interrelation among the optimization variables. The objective is to identify a large class of networks over which every OPF problem can be solved in polynomial time. To this end, a convex relaxation is proposed, which solves the OPF problem exactly for every radial network and every meshed network with a sufficient number of phase shifters, provided power over-delivery is allowed. The concept of “power over-delivery” is equivalent to relaxing the power balance equations to inequality constraints.
Flow Networks: In this part of the dissertation, the minimum-cost flow problem over an arbitrary flow network is considered. In this problem, each node is associated with some possibly unknown injection, each line has two unknown flows at its ends related to each other via a nonlinear function, and all injections and flows need to satisfy certain box constraints. This problem, named generalized network flow (GNF), is highly non-convex due to its nonlinear equality constraints. Under the assumption of monotonicity and convexity of the flow and cost functions, a convex relaxation is proposed, which always finds the optimal injections. A primary application of this work is in the OPF problem. The results of this work on GNF prove that the relaxation on power balance equations (i.e., load over-delivery) is not needed in practice under a very mild angle assumption.
Generalized Weighted Graphs: Motivated by power optimizations, this part aims to find a global optimization technique for a nonlinear optimization defined over a generalized weighted graph. Every edge of this type of graph is associated with a weight set corresponding to the known parameters of the optimization (e.g., the coefficients). The motivation behind this problem is to investigate how the (hidden) structure of a given real/complex valued optimization makes the problem easy to solve, and indeed the generalized weighted graph is introduced to capture the structure of an optimization. Various sufficient conditions are derived, which relate the polynomial-time solvability of different classes of optimization problems to weak properties of the generalized weighted graph such as its topology and the sign definiteness of its weight sets. As an application, it is proved that a broad class of real and complex optimizations over power networks are polynomial-time solvable due to the passivity of transmission lines and transformers.
Resumo:
Nos últimos anos, o consumo de energia vem crescendo mundialmente nos grandes centros urbanos, e esforços na área de eficiência energética estão sendo implantados, a fim de reduzir o consumo no horário da ponta e interrupções da rede. O aproveitamento das fontes renováveis, como o fotovoltaico em uma edificação se torna um atrativo a mais para a matriz energética num momento em que o país prima pela universalização dos serviços de energia e a classificação de edifícios comerciais, de serviço e públicos, além dos residenciais quanto à eficiência energética através do Procel Edifica (RTQ-C e RTQ-R). Os sistemas fotovoltaicos podem configurar perfis de uso nas edificações de modo a gerar energia para consumo próprio ou ligado à rede e ainda ter influência na arquitetura do prédio com revestimento: os perfis podem está em telhados, fachadas ou janelas, amenizando em alguns casos a carga térmica no prédio com sombreamento arquitetônico. Hoje, com o avanço da tecnologia no setor de armazenagem é possível, o atendimento com segurança e eficiência a uma edificação ou direcionar esta armazenagem a uma demanda específica como o atendimento à demanda de ciclo profundo, tais como, iluminação externa e recarga de veículos elétricos. Partindo da premissa de sistemas interruptos de energia, UPS, uso de fonte secundária como FV, baterias e Flywheel é apresentado uma forma de melhor gerenciar a energia armazenada, podendo estender a vida útil da bateria e conseqüentemente de todo o sistema fotovoltaico na edificação. Esta forma de armazenar energia proporciona um serviço de uso contínuo sem percepção das interrupções da rede com garantia de 20 anos, tal qual o módulo fotovoltaico, com esta proposta as perdas de energia elétrica na edificação serão atenuadas, pois a eletricidade será utilizada de forma eficiente e inteligente. O ponto de partida do estudo de caso no prédio do IBAM são os sistemas fotovoltaicos com geração distribuída (mini-redes) conectados à rede que são instalados para fornecer energia ao consumidor, complementando a quantidade de energia demandada, caso haja algum aumento do consumo de energia na edificação, ou ainda utilizar o sistema fotovoltaico na hora da ponta e interrupções do sistema da rede no período fora da ponta. A estocagem inercial por meio do Flywheel tem um papel fundamental nesta mini-rede (Flywheel, bateria VRLA, UPS, inversor e STS), pois a sua utilização pode ser apontada como uma inovação tecnológica quanto à regulação de tensão no sistema de energia elétrica, além de preparar a edificação para o smart-grid. Esta configuração de acumulação de energia permitiu a analise do deslocamento desta energia armazenada para o consumo no horário de ponta, mudando o conceito de sistemas fotovoltaicos autônomos no meio urbano e rural no país. Este conceito de armazenagem se confirma então como um aporte na eficiência de energia na edificação, podendo carrear economia de energia substancial, além de proporcionar uma confiabilidade no serviço de energia, com um baixo retorno do investimento e com uma garantia de funcionamento com pequena ou nenhuma manutenção durante o período de vida de 20 anos.
Resumo:
Atualmente existem diferentes ferramentas computacionais para auxílio nos estudos de coordenação da proteção, que permitem traçar as curvas dos relés, de acordo com os parâmetros escolhidos pelos projetistas. Entretanto, o processo de escolha das curvas consideradas aceitáveis, com um elevado número de possibilidades e variáveis envolvidas, além de complexo, requer simplificações e iterações do tipo tentativa e erro. Neste processo, são fatores fundamentais tanto a experiência e o conhecimento do especialista, quanto um árduo trabalho, sendo que a coordenação da proteção é qualificada pela IEEE Std. 242 como sendo mais uma arte do que uma ciência. Este trabalho apresenta o desenvolvimento de um algoritmo genético e de um algoritmo inspirado em otimização por colônia de formigas, para automatizar e otimizar a coordenação da função de sobrecorrente de fase de relés digitais microprocessados (IEDs), em subestações industriais. Seis estudos de caso, obtidos a partir de um modelo de banco de dados, baseado em um sistema elétrico industrial real, são avaliados. Os algoritmos desenvolvidos geraram, em todos os estudos de caso, curvas coordenadas, atendendo a todas as restrições previamente estabelecidas e as diferenças temporais de atuação dos relés, no valor de corrente de curto circuito trifásica, apresentaram-se muito próximas do estabelecido como ótimo. As ferramentas desenvolvidas demonstraram potencialidade quando aplicadas nos estudos de coordenação da proteção, tendo resultados positivos na melhoria da segurança das instalações, das pessoas, da continuidade do processo e do impedimento de emissões prejudiciais ao meio ambiente.