940 resultados para Pick-by-Vision
Resumo:
Light sources with three spectral bands in specific spectral positions are known to have high-color-discrimination capability. W. A. Thornton hypothesized that they may also enhance color discrimination for color-deficient observers. This hypothesis was tested here by comparing the Rösch–MacAdam color volume for color-deficient observers rendered by three of these singular spectra, two reported previously and one derived in this paper by maximization of the Rösch–MacAdam color solid. It was found that all illuminants tested enhance discriminability for deuteranomalous observers, but their impact on other congenital deficiencies was variable. The best illuminant was the one derived here, as it was clearly advantageous for the two red–green anomalies and for tritanopes and almost neutral for red–green dichromats. We conclude that three-band spectra with high-color-discrimination capability for normal observers do not necessarily produce comparable enhancements for color-deficient observers, but suitable spectral optimization clearly enhances the vision of the color deficient.
Resumo:
Background: Refractive error is defined as the inability of the eye to bring parallel rays of light into focus on the retina, resulting in nearsightedness (myopia), farsightedness (Hyperopia) or astigmatism. Uncorrected refractive error in children is associated with increased morbidity and reduced educational opportunities. Vision screening (VS) is a method for identifying children with visual impairment or eye conditions likely to lead to visual impairment. Objective: To analyze the utility of vision screening conducted by teachers and to contribute to a better estimation of the prevalence of childhood refractive errors in Apurimac, Peru. Design: A pilot vision screening program in preschool (Group I) and elementary school children (Group II) was conducted with the participation of 26 trained teachers. Children whose visual acuity was<6/9 [20/30] (Group I) and≤6/9 (Group II) in one or both eyes, measured with the Snellen Tumbling E chart at 6 m, were referred for a comprehensive eye exam. Specificity and positive predictive value to detect refractive error were calculated against clinical examination. Program assessment with participants was conducted to evaluate outcomes and procedures. Results: A total sample of 364 children aged 3–11 were screened; 45 children were examined at Centro Oftalmológico Monseñor Enrique Pelach (COMEP) Eye Hospital. Prevalence of refractive error was 6.2% (Group I) and 6.9% (Group II); specificity of teacher vision screening was 95.8% and 93.0%, while positive predictive value was 59.1% and 47.8% for each group, respectively. Aspects highlighted to improve the program included extending training, increasing parental involvement, and helping referred children to attend the hospital. Conclusion: Prevalence of refractive error in children is significant in the region. Vision screening performed by trained teachers is a valid intervention for early detection of refractive error, including screening of preschool children. Program sustainability and improvements in education and quality of life resulting from childhood vision screening require further research.
Resumo:
The current trend in the evolution of sensor systems seeks ways to provide more accuracy and resolution, while at the same time decreasing the size and power consumption. The use of Field Programmable Gate Arrays (FPGAs) provides specific reprogrammable hardware technology that can be properly exploited to obtain a reconfigurable sensor system. This adaptation capability enables the implementation of complex applications using the partial reconfigurability at a very low-power consumption. For highly demanding tasks FPGAs have been favored due to the high efficiency provided by their architectural flexibility (parallelism, on-chip memory, etc.), reconfigurability and superb performance in the development of algorithms. FPGAs have improved the performance of sensor systems and have triggered a clear increase in their use in new fields of application. A new generation of smarter, reconfigurable and lower power consumption sensors is being developed in Spain based on FPGAs. In this paper, a review of these developments is presented, describing as well the FPGA technologies employed by the different research groups and providing an overview of future research within this field.
Resumo:
Purpose: To determine whether systemic fungal infection could cause activation of retinal microglia and therefore could be potentially harmful for patients with retinal degenerative diseases. Methods: Activation of retinal microglia was measured in a model of sublethal invasive candidiasis in C57BL/6J mice by (i) confocal immunofluorescence and (ii) flow cytometry analysis, using anti-CD11b, anti-Iba1, anti-MHCII and anti-CD45 antibodies. Results: Systemic fungal infection causes activation of retinal microglia, with phenotypic changes in morphology, surface markers expression, and microglial re-location in retinal layers. Conclusions: As an excessive or prolonged microglial activation may lead to chronic inflammation with severe pathological side effects, causing or worsening the course of retinal dystrophies, a systemic infection may represent a risk factor to be considered in patients with ocular neurodegenerative diseases, such as diabetic retinopathy, glaucoma, age-related macular degeneration or retinitis pigmentosa.
Resumo:
Purpose. To evaluate theoretically in normal eyes the influence on IOL power (PIOL) calculation of the use of a keratometric index (nk) and to analyze and validate preliminarily the use of an adjusted keratometric index (nkadj) in the IOL power calculation (PIOLadj). Methods. A model of variable keratometric index (nkadj) for corneal power calculation (Pc) was used for IOL power calculation (named PIOLadj). Theoretical differences ($PIOL) between the new proposed formula (PIOLadj) and which is obtained through Gaussian optics (PIOL Gauss) were determined using Gullstrand and Le Grand eye models. The proposed new formula for IOL power calculation (PIOLadj) was prevalidated clinically in 81 eyes of 81 candidates for corneal refractive surgery and compared with Haigis, HofferQ, Holladay, and SRK/T formulas. Results. A theoretical PIOL underestimation greater than 0.5 diopters was present in most of the cases when nk = 1.3375 was used. If nkadj was used for Pc calculation, a maximal calculated error in $PIOL of T0.5 diopters at corneal vertex in most cases was observed independently from the eye model, r1c, and the desired postoperative refraction. The use of nkadj in IOL power calculation (PIOLadj) could be valid with effective lens position optimization nondependent of the corneal power. Conclusions. The use of a single value of nk for Pc calculation can lead to significant errors in PIOL calculation that may explain some IOL power overestimations with conventional formulas. These inaccuracies can be minimized by using the new PIOLadj based on the algorithm of nkadj.
Resumo:
Purpose. Transplantation of human central nervous system stem cells (HuCNS-SC) into the subretinal space of Royal College of Surgeons (RCS) rats preserves photoreceptors and visual function. To explore possible mechanism(s) of action underlying this neuroprotective effect, we performed a detailed morphologic and ultrastructure analysis of HuCNS-SC transplanted retinas. Methods. The HuCNS-SC were transplanted into the subretinal space of RCS rats. Histologic examination of the transplanted retinas was performed by light and electron microscopy. Areas of the retina adjacent to HuCNS-SC graft (treated regions) were analyzed and compared to control sections obtained from the same retina, but distant from the transplant site (untreated regions). Results. The HuCNS-SC were detected as a layer of STEM 121 immunopositive cells in the subretinal space. In treated regions, preserved photoreceptor nuclei, as well as inner and outer segments were identified readily. In contrast, classic signs of degeneration were observed in the untreated regions. Interestingly, detailed ultrastructure analysis revealed a striking preservation of the photoreceptor–bipolar–horizontal cell synaptic contacts in the outer plexiform layer (OPL) of treated areas, in stark contrast with untreated areas. Finally, the presence of phagosomes and vesicles exhibiting the lamellar structure of outer segments also was detected within the cytosol of HuCNS-SC, indicating that these cells have phagocytic capacity in vivo. Conclusions. This study reveals the novel finding that preservation of specialized synaptic contacts between photoreceptors and second order neurons, as well as phagocytosis of photoreceptor outer segments, are potential mechanism(s) of HuCNS-SC transplantation, mediating functional rescue in retinal degeneration.
Resumo:
A semiotic theory of systems derived from language would have the purpose of classifying all the systems of linguistic expression: philosophy, ideology, myth, poetry, art, as much as the dream, lapsus, and free association in a pluridimensional matrix that will interact with many diversified fields. In each one of these discourses it is necessary to consider a plurality of questions, the essence of which will only be comprehensible by the totality; it will be necessary to ask, in the first place, what will be the purpose of this language, what function does it fulfill and for which reason has it been constructed. The concept of World vision (WV) is introduced and its relation with Generalized Collective Conscience (GCC) and Particularized Collective Conscience. Culture implies a particular WV. Culture creates GCC. The semantic field is a structure that formalizes the units of a certain culture constituting a portion of the vision of the Reality that owns this culture. An ecological case is explained.
Resumo:
In this article, we present a new framework oriented to teach Computer Vision related subjects called JavaVis. It is a computer vision library divided in three main areas: 2D package is featured for classical computer vision processing; 3D package, which includes a complete 3D geometric toolset, is used for 3D vision computing; Desktop package comprises a tool for graphic designing and testing of new algorithms. JavaVis is designed to be easy to use, both for launching and testing existing algorithms and for developing new ones.
Resumo:
Objectives: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Study Design and Setting: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Testeretest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen’s kappa (k). Results: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good testeretest repeatability both for the scores obtained [ICC 5 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (k 5 0.612; 95% CI: 0.384, 0.839). Conclusion: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.
Resumo:
All retinal disorders, regardless of their aetiology, involve the activation of oxidative stress and apoptosis pathways. The administration of neuroprotective factors is crucial in all phases of the pathology, even when vision has been completely lost. The retina is one of the most susceptible tissues to reactive oxygen species damage. On the other hand, proper development and functioning of the retina requires a precise balance between the processes of proliferation, differentiation and programmed cell death. The life-or-death decision seems to be the result of a complex balance between pro- and anti-apoptotic signals. It has been recently shown the efficacy of natural products to slow retinal degenerative process through different pathways. In this review, we assess the neuroprotective effect of two compounds used in the ancient pharmacopoeia. On one hand, it has been demonstrated that administration of the saffron constituent safranal to P23H rats, an animal model of retinitis pigmentosa, preserves photoreceptor morphology and number, the capillary network and the visual response. On the other hand, it has been shown that systemic administration of tauroursodeoxycholic acid (TUDCA), the major component of bear bile, to P23H rats preserves cone and rod structure and function, together with their contact with postsynaptic neurons. The neuroprotective effects of safranal and TUDCA make these compounds potentially useful for therapeutic applications in retinal degenerative diseases.
Resumo:
Machine vision is an important subject in computer science and engineering degrees. For laboratory experimentation, it is desirable to have a complete and easy-to-use tool. In this work we present a Java library, oriented to teaching computer vision. We have designed and built the library from the scratch with enfasis on readability and understanding rather than on efficiency. However, the library can also be used for research purposes. JavaVis is an open source Java library, oriented to the teaching of Computer Vision. It consists of a framework with several features that meet its demands. It has been designed to be easy to use: the user does not have to deal with internal structures or graphical interface, and should the student need to add a new algorithm it can be done simply enough. Once we sketch the library, we focus on the experience the student gets using this library in several computer vision courses. Our main goal is to find out whether the students understand what they are doing, that is, find out how much the library helps the student in grasping the basic concepts of computer vision. In the last four years we have conducted surveys to assess how much the students have improved their skills by using this library.
Resumo:
Purpose: To compare the manifest refractive cylinder (MRC) predictability of myopic astigmatism laser in situ keratomileusis (LASIK) between eyes with low and high ocular residual astigmatism (ORA). Setting: London Vision Clinic, London, United Kingdom. Design: Retrospective case study. Methods: The ORA was considered the vector difference between the MRC and the corneal astigmatism. The index of success (IoS), difference vector ÷ MRC, was analyzed for different groups as follows: stage 1, low ORA (ORA ÷ MRC <1), high ORA (ORA ÷ MRC ≥1); stage 2, low ORA group reduced to match the high ORA group for MRC; stage 3, grouped by ORA magnitude with low ORA (<0.50 diopters [D]), mid ORA (0.50 to 1.24 D), and high ORA (≥1.25 D); stage 4, high ORA group subdivided into low (<0.75 D) and high (≥0.75 D) corneal astigmatism. Results: For stage 1, the mean preoperative MRC and mean IoS were −1.32 D ± 0.65 (SD) (range −0.55 to −3.77 D) and 0.27, respectively, for low ORA and −0.79 ± 0.20 D (range −0.56 to −2.05 D) and 0.37, respectively, for high ORA. For stage 2, the mean IoS increased to 0.32 for low ORA. For stage 3, the mean IoS was 0.28, 0.29, and 0.31 for low ORA, mid ORA, and high ORA, respectively. For stage 4, the mean IoS was 0.20 for high ORA/low corneal astigmatism and 0.35 for high ORA/high corneal astigmatism. Conclusions: The MRC predictability was slightly worse in eyes with high ORA when grouped by the ORA ÷ MRC. Matching for the MRC and grouping by ORA magnitude resulted in similar predictability; however, eyes with high ORA and high corneal astigmatism were less predictable.
Resumo:
Contains medical cases copied by James Lloyd (1728-1810), primarily between 1751 and 1754, from Mr. Steed, an apothecary at Guy's Hospital in London, England. The volume has additional medical cases dating from 1780 to 1787. Lloyd transcribed the names, ages, and symptoms of the patients, as well as the medicines and medical care delivered to them. The volume is divided into chapters based on the type of case, which included vision loss; fluor albus, or leucorrhoea; diabetes; and dysentery. There is also a letter pasted into the volume addressed to Dr. Brigham of the Boston Medical Library Association from Lloyd's great-grandson, dated 4 November 1887.
Resumo:
Tese de doutoramento, Farmácia (Biologia Celular e Molecular), Universidade de Lisboa, Faculdade de Farmácia, 2016
Resumo:
Le traumatisme craniocérébral léger (TCCL) a des effets complexes sur plusieurs fonctions cérébrales, dont l’évaluation et le suivi peuvent être difficiles. Les problèmes visuels et les troubles de l’équilibre font partie des plaintes fréquemment rencontrées après un TCCL. En outre, ces problèmes peuvent continuer à affecter les personnes ayant eu un TCCL longtemps après la phase aiguë du traumatisme. Cependant, les évaluations cliniques conventionnelles de la vision et de l’équilibre ne permettent pas, la plupart du temps, d’objectiver ces symptômes, surtout lorsqu’ils s’installent durablement. De plus, il n’existe pas, à notre connaissance, d’étude longitudinale ayant étudié les déficits visuels perceptifs, en tant que tels, ni les troubles de l’équilibre secondaires à un TCCL, chez l’adulte. L’objectif de ce projet était donc de déterminer la nature et la durée des effets d’un tel traumatisme sur la perception visuelle et sur la stabilité posturale, en évaluant des adultes TCCL et contrôles sur une période d’un an. Les mêmes sujets, exactement, ont participé aux deux expériences, qui ont été menées les mêmes jours pour chacun des sujets. L’impact du TCCL sur la perception visuelle de réseaux sinusoïdaux définis par des attributs de premier et de second ordre a d’abord été étudié. Quinze adultes diagnostiqués TCCL ont été évalués 15 jours, 3 mois et 12 mois après leur traumatisme. Quinze adultes contrôles appariés ont été évalués à des périodes identiques. Des temps de réaction (TR) de détection de clignotement et de discrimination de direction de mouvement ont été mesurés. Les niveaux de contraste des stimuli de premier et de second ordre ont été ajustés pour qu’ils aient une visibilité comparable, et les moyennes, médianes, écarts-types (ET) et écarts interquartiles (EIQ) des TR correspondant aux bonnes réponses ont été calculés. Le niveau de symptômes a également été évalué pour le comparer aux données de TR. De façon générale, les TR des TCCL étaient plus longs et plus variables (plus grands ET et EIQ) que ceux des contrôles. De plus, les TR des TCCL étaient plus courts pour les stimuli de premier ordre que pour ceux de second ordre, et plus variables pour les stimuli de premier ordre que pour ceux de second ordre, dans la condition de discrimination de mouvement. Ces observations se sont répétées au cours des trois sessions. Le niveau de symptômes des TCCL était supérieur à celui des participants contrôles, et malgré une amélioration, cet écart est resté significatif sur la période d’un an qui a suivi le traumatisme. La seconde expérience, elle, était destinée à évaluer l’impact du TCCL sur le contrôle postural. Pour cela, nous avons mesuré l’amplitude d’oscillation posturale dans l’axe antéropostérieur et l’instabilité posturale (au moyen de la vitesse quadratique moyenne (VQM) des oscillations posturales) en position debout, les pieds joints, sur une surface ferme, dans cinq conditions différentes : les yeux fermés, et dans un tunnel virtuel tridimensionnel soit statique, soit oscillant de façon sinusoïdale dans la direction antéropostérieure à trois vitesses différentes. Des mesures d’équilibre dérivées de tests cliniques, le Bruininks-Oseretsky Test of Motor Proficiency 2nd edition (BOT-2) et le Balance Error Scoring System (BESS) ont également été utilisées. Les participants diagnostiqués TCCL présentaient une plus grande instabilité posturale (une plus grande VQM des oscillations posturales) que les participants contrôles 2 semaines et 3 mois après le traumatisme, toutes conditions confondues. Ces troubles de l’équilibre secondaires au TCCL n’étaient plus présents un an après le traumatisme. Ces résultats suggèrent également que les déficits affectant les processus d’intégration visuelle mis en évidence dans la première expérience ont pu contribuer aux troubles de l’équilibre secondaires au TCCL. L’amplitude d’oscillation posturale dans l’axe antéropostérieur de même que les mesures dérivées des tests cliniques d’évaluation de l’équilibre (BOT-2 et BESS) ne se sont pas révélées être des mesures sensibles pour quantifier le déficit postural chez les sujets TCCL. L’association des mesures de TR à la perception des propriétés spécifiques des stimuli s’est révélée être à la fois une méthode de mesure particulièrement sensible aux anomalies visuomotrices secondaires à un TCCL, et un outil précis d’investigation des mécanismes sous-jacents à ces anomalies qui surviennent lorsque le cerveau est exposé à un traumatisme léger. De la même façon, les mesures d’instabilité posturale se sont révélées suffisamment sensibles pour permettre de mesurer les troubles de l’équilibre secondaires à un TCCL. Ainsi, le développement de tests de dépistage basés sur ces résultats et destinés à l’évaluation du TCCL dès ses premières étapes apparaît particulièrement intéressant. Il semble également primordial d’examiner les relations entre de tels déficits et la réalisation d’activités de la vie quotidienne, telles que les activités scolaires, professionnelles ou sportives, pour déterminer les impacts fonctionnels que peuvent avoir ces troubles des fonctions visuomotrice et du contrôle de l’équilibre.