910 resultados para Permanent magnet synchronous generator
Resumo:
The Trident Energy TE5 is a prototype wave energy converter operating on the principle of having direct-drive linear generators mounted above the water surface, coupled to floats moving under the rig deck. This paper describes aspects of the TE5 design, including its generators, power electronic systems and the conception of its marine structure.
Resumo:
High Temperature superconductors are able to carry very high current densities, and thereby sustain very high magnetic fields. There are many projects which use the first property and these have concentrated on power generation, transmission and utilization, however there are relatively few which are currently exploiting the ability to sustain high magnetic fields. There are two main reasons for this: high field wound magnets can and have been made from both BSCCO and YBCO but currently their cost is much higher than the alternative provided by low Tc materials such as Nb3Sn and NbTi. An alternative form of the material is the bulk form which can be magnetized to high fields and using flux pumping this can be done in situ. This paper explores some of the applications of bulk superconductors and describes methods of producing field patterns using the highly uniform magnetic fields required for MRI and accelerator magnets as the frame of reference. The patterns are not limited to uniform fields and it is entirely possible to produce a field varying sinusoidally in space such as would be required for a motor or a generator. The scheme described in this paper describes a dipole magnet such as is found in an accelerator magnet. The tunnel is 30 × 50 × 1000 mm and we achieve a uniformity of better than 200 ppm over the 1000 mm length and better than 1 ppm over the central 500 mm region. The paper presents results for both the overall uniformity and the integrated uniformity which is 302 ppm over the 1000 mm length. © 2010 IEEE.
Resumo:
The Brushless Doubly-Fed Induction Generator (BDFIG) shows commercial promise as replacement for doublyfed slip-ring generators for wind power applications by offering reduced capital and operational costs due to its brushless operation. In order to facilitate its commercial deployment, the capabilities of the BDFIG system to comply with grid code requirements have to be assessed. This paper, for the first time, studies the performance of the BDFIG under grid fault ride-through and presents the dynamic behaviour of the machine during three-phase symmetrical voltage dips. Both full and partial voltage dips are studied using a vector model. Simulation and experimental results are provided for a 180 frame BDFIG.
Resumo:
The Brushless Doubly-Fed Machine (BDFM) is an electrical machine that allows brushless operation in many applications where the Doubly-Fed Induction Generator (DFIG) is currently used. In recent years work on BDFM control means that the machine can now be run stably across its working range. However, little work has been done to define the working area in which BDFM can safely be operated without exceeding its material and stability limits. This paper sets out the theoretical backing for an operating chart of an ideal BDFM similar to that of the synchronous machine. It goes on to show that though the ideal chart gives the right form, non-ideal parameters (especially the finite magnetizing inductances) significantly effect the locations of the limits. Some preliminary experimental data obtained for a 225 frame size machine support the form of the chart. Finally it is shown how the operating chart can be used to chose appropriately sized converters for the BDFM. © 2009 IEEE.
Resumo:
This paper proposes a single-phase variant of the Brushless Doubly-Fed Machine, the Single-Phase BDFM, SPB. Like the BDFM it is a variable speed generator which requires a converter rated at only a fraction of the machine rating, using structure with no brushes. Unlike the BDFM, most of its power is delivered directly into a single-phase grid connection. As such it is a potential replacement for PM generators in small-ish wind turbines, potentially with a much lower cost. In this paper we give details of its operation, with reference to results from the first prototype SPB. We also suggest how it may be controlled, again with experimental results. © 2011 IEEE.
Resumo:
The paper presents a novel vector control structure for the Brushless Doubly-Fed Machine (BDFM) which is derived based on the machine synchronous operation. In fact, the synchronous operation of the BDFM provides an efficient approach for determining the required reference angle in the machine vector control structure. The utilization of such reference angle makes the vector control structure presented in this paper different from and, in fact, more effective than the existing rotor flux and stator flux orientation schemes proposed for the machine. The results of implementing the vector control scheme in simulations confirm the effectiveness of the proposed approach for the BDFM control. © 2010 IEEE.
Resumo:
The Brushless Doubly-Fed Induction Generator (BDFIG) shows commercial promise for wind power generation due to its lower cost and higher reliability compared to the Doubly-Fed Induction Generator (DFIG). For the purposes of commercialisation, the BDFIG must meet grid codes at all times. Nowadays, all new wind generators have to ride through certain grid faults, and the Low-Voltage Ride Through (LVRT) capability has become one of the most important points on which to assess the performance a generator. This paper, for the first time, proposes a control scheme to enable the the BDFIG to ride through symmetrical voltage dips. Simulation results and experimental results on a prototype BDFIG show that the proposed scheme gives the capability to ride through low voltage faults. © 2011 IEEE.
Resumo:
A method and device for periodically perturbing the flow field within a microfluidic device to provide regular droplet formation at high speed.
Resumo:
An experimental study of bleed and vortex generators in supersonic ow has been conducted. Methods were developed to analyze and directly compare the two systems' effects on turbulent boundary layers to better understand their potential to mitigate ow separation. LDA was used to measure two components of velocity in the boundary-layer for three cases|baseline, with bleed, or with a VG|at Mach numbers of 1.3, 1.5 and 1.8. The bleed system was comprised of a series of 2mm diameter normal holes operated at different suction rates, removing up to 10% of the incoming boundary layer. Three VG shapes were tested only at Mach 1.5 and 1.8. Measurements of the evolution of Hi and Cf downstream of each device indicate that Hi is not an appropriate parameter to gauge the effectiveness of vortex generators due to boundary layer wake distortion. The skin friction coeficient Cf may be a more appropriate measure. Similar increases in Cf were generated by VGs and bleed. The recovery to baseline conditions downstream of bleed was sensitive to Mach number, and more investigation of that effect will be required. Copyright © 2012 by University of Cambridge.