957 resultados para PRESSURE RANGE GIGA PA


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The ability to walk is impaired in obese by anthropometric factors (BMI and height), musculoskeletal pain and level of inactivity. Little is known about the influence of body adiposity and the acute response of the cardiovascular system during whole the 6-minute walk test (6mWT). Objective: To evaluate the effect of anthropometric measures (BMI and WHR waist-to-hip ratio), the effort heart and inactivity in ability to walk the morbidly obese. Materials and Methods: a total 36 morbidly obese (36.23 + 11.82 years old, BMI 49.16 kg/m2) were recruited from outpatient department of treatment of obesity and bariatric surgery in University Hospital Onofre Lopes and anthropometric measurements of obesity (BMI and WHR), pulmonary function, pattern habitual physical activity (Baecke Questionnaire) and walking capacity (6mWT). The patient was checking to measure: heart rate (HR), breathing frequency (BF), peripheral oxygen saturation, level of perceived exertion, systemic arterial pressure and duplo-produto (DP), moreover the average speed development and total distance walking. The data were analysed between gender and pattern of body adiposity, measuring the behavior minute by minute of walking. The Pearson and Spearmam correlation coefficients were calculated, and stepwise multiple Regression examined the predictors of walking capacity. All analyses were performed en software Statistic 6.0. Results: 20 obese patients had abdominal adiposity (WHR = 1.01), waist circumference was 135.8 cm in women (25) and 139.8 cm in men (10). Walked to the end of 6mWT 412.43 m, with no differences between gender and adiposity. The total distance walked by obesity alone was explained by BMI (45%), HR in the sixth minute (43%), the Baecke (24%) and fatigue (-23%). 88.6% of obese (31) performed the test above 60% of maximal HR, while the peak HR achieved at 5-minute of 6mWT. Systemic arterial pressure and DP rised after walking, but with no differences between gender and adiposity. Conclusion: The walk of obese didn´t suffers influence of gender or the pattern of body adiposity. The final distance walked is attributed to excess body weight, stress heart, the feeling of effort required by physical activity and level of sedentary to obese. With a minute of walking, the obeses achieved a range of intensity cardiovascular trainning

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modern industry has frequently employed ethylene glycol ethers as monomers in plasma polymerization process to produce different types of coatings. In this work we used a stainless steel plasma reactor to grow thin polymeric films from low pressure RF excited plasma of diethylene glycol dimethyl ether. Plasmas were generated at 5W RF power in the range of 16 Pa to 60 Pa. The molecular structure of plasma polymerized films and their optical properties were analyzed by Fourier Transform Infrared Spectroscopy (FTIR) and UltravioletVisible Spectroscopy, respectively. The IR spectra show C-H stretching at 3000-2900 cm(-1), C=O stretching at 1730-1650 cm(-1), C-H bending at 1440-1380 cm(-1), C-O and C-O-C stretching at 1200-1000 cm(-1). The refraction index was around 1.5 and the optical gap calculated from absorption coefficient presented value near 3.8 eV. Water contact angle of the films ranged from 40 degrees to 35 degrees with corresponding surface energy from 66 to 73x10(-7) J. Because of its favorable optical and hydrophilic characteristics these films can be used in ophthalmic industries as glass lenses coatings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

FUNDAMENTO: A atividade do sistema renina-angiotensina-aldosterona tem relação direta com sobrepeso e sedentarismo, e essas variáveis se associam à hipertensão arterial (HA). O exercício aeróbio propicia melhor controle da pressão arterial (PA) por agir nos mecanismos da regulação pressórica, dentre eles, a atividade de renina plasmática (ARP). OBJETIVO: Avaliar a influência do exercício aeróbio sobre ARP em portadores de HA com sobrepeso. MÉTODOS: Foram avaliados níveis pressóricos, bioquímicos e antropométricos pré e pós-treinamento de 16 semanas, três vezes por semana, a 60%-80% da frequência cardíaca máxima. Os dados foram expressos em média ± desvio padrão ou mediana e intervalo interquartílico, e analisados pelo teste t, Mann-Withney e ANOVA (p < 0,05). RESULTADOS: Vinte indivíduos apresentaram média de idade de 57 ± 7,0 anos e índice de massa corpórea de 30 ± 3,5 kg/m². O treinamento aeróbio promoveu a redução da porcentagem de gordura corporal (35 ± 7,8 para 30 ± 5,6 %), da frequência cardíaca (FC) (80 ± 10,4 para 77 ± 8,5 bpm) e da pressão de pulso (PP) (50 ± 11,8 para 46 ± 10,0 mmHg) na amostra geral (p < 0,05), sem redução da ARP, que variou de 0,8 (0,45-2,0) a 1,45 (0,8-2,15) ηg/ml/h (p = 0,055). No grupo com redução da circunferência abdominal (CA) (n = 8) houve redução da PA sistólica e PP (p < 0,05). No grupo sem redução da CA, nenhuma das variáveis pressóricas apresentou alteração. A ARP não se associou com nenhuma variável estudada. O efeito do treinamento aeróbio associou-se à redução da PP na casuística total e à redução da PA sistólica no subgrupo com redução da CA. CONCLUSÃO: O treinamento aeróbio não reduziu a ARP em hipertensos com sobrepeso.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oxygen-binding properties, blood gases, and acid-base parameters were studied in tegu lizards, Tupinambis merianae, at different seasons and temperatures. Independent of temperature and pH, blood oxygen affinity was higher in dormant lizards than in those active during the summer. Haematocrit (Hct) and hemoglobin content ([Hb]) were greater in active lizards resulting in a higher oxygen-carrying capacity. Nucleoside triphosphate content ([NTP]) was reduced during dormancy, but the ratio between [NTP] and [Hb] remained unchanged. Dormancy was accompanied by an increase in plasma bicarbonate ([HCO(3)(-)]PI) and an elevation of arterial CO(2) partial pressure (P(aCO2)) and CO(2) content in the plasma (C(PlCO2)). These changes in acid-base parameters persist over a broad range of body temperatures. In vivo, arterial O(2) partial pressure (Pa(O2)) and O(2) content (Ca(O2)) were not affected by season and tended to increase with temperature. Arterial pH (pH(a)) of dormant animals is reduced compared to active lizards at body temperatures below 15 degreesC, while no significant difference was noticed at higher temperatures. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The behaviour of dc longitudinal and transverse conductivity in self-assembled plastdoped films of polyaniline has been studied over the range of 9 K to 320 K, under different applied mechanical pressures. We observe a progressive evolution of the conductivity picture as the applied pressure is increased, especially in the transverse direction, where the conductivity tends to lower as the pressure is increased. (C) 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demand by high performance materials that have to support severe service conditions at a reasonable cost has been forcing the powder metallurgy to improve constantly. The most recent and more important innovation in the area is the process of powder injection.Powder injection molding (PIM) is a technology capable of producing a new range of components from powders. This advanced technology overcomes the existent limitations in the forming of products with complex geometry. The process presents countless variations which are used in the industry today. Invariably, it consists of mixing the powders and a thermo-plastic binder, injecting the mass in the mold in the wanted form, debinding, sintering and making optional secondary operations, as for example, machinery.The purpose of this work is to review the metal injection molding techniques and apply the low pressure injection molding process to family of parts using metallic powder with 10 mum particle size. This work also comments the design and construction of a low pressure injection machine and injection molds. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present work we consider a dynamical system of mum size particles around the Earth subject to the effects of radiation pressure. Our main goal is to study the evolution of its relative velocity with respect to the co-planar circular orbits that it crosses. The particles were initially in a circular geostationary orbit, and the particles size were in the range between 1 and 100 mum. The radiation pressure produces variations in its eccentricity, resulting in a change in its orbital velocity. The results indicated the maximum linear momentum and kinetic energy increases as the particle size increases. For a particle of 1 mum the kinetic energy is approximately 1.56 x 10(-7) J and the momentum is 6.27 x 10(-11) kg m/s and for 100 mum the energy is approximately 1.82 x 10(-4) J and the momentum is 2.14 x 10(-6) kg m/s. (C) 2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of the influence of motion and initial intra-articular pressure (IAP) on intra-articular pressure profiles in equine cadaver metatarsophalangeal (MTP) joints was undertaken as a prelude to in vivo studies, Eleven equine cadaver MTP joints were submitted to 2 motion frequencies of 5 and 10 cycles/min of flexion and extension, simulating the condition of lower and higher (double) rates of passive motion. These frequencies were applied and pressure profiles generated with initial normal intra-articular pressure (-5 mmHg) and subsequently 30 mmHg intra-articular pressure obtained by injection of previously harvested synovial fluid.The 4 trials performed were 1) normal IAP; 5 cyles/min; 2) normal IAP; 10 cycles/min; 3) IAP at 30 mmHg; 5 cycles/min and 4) IAP at 30 mmHg; 10 cycles/min. The range of joint motion applied (mean +/- s.e.) was 67.6 +/- 1.61 degrees with an excursion from 12.2 +/- 1.2 degrees in extension to 56.2 +/- 2.6 degrees in flexion, Mean pressure recorded in mmHg for the first and last min of each trial, respectively, were 1) -5.7 +/- 0.9 and -6.3 +/- 1.1; 2) -5.3 +/- 1.1 and -6.2 +/- 1.1; 3) 58.8 +/- 8.0 and 42.3 +/- 7.2; 4) 56.6 +/- 3.7 and 40.3 +/- 4.6. Statistical analyses showed a trend for difference between the values for the first and last minute in trial 3 (0.05>P<0.1) with P = 0.1 and significant difference (P = 0.02) between the mean IAP of the first and last min in trial 4. The loss of intra-articular pressure associated with time and motion was 10.5, 16.9, 28.1 and 28.9% for trials 1-4, respectively. As initial intraarticular pressure and motion increased, the percent loss of intra-articular pressure increased.The angle of lowest pressure was 12.2 +/- 1.2 (mean +/- s.e.) in extension in trials 1 and 2, In trials 3 and 4, the lowest pressures were obtained in flexion with the joints at 18.5 +/- 2.0 degrees (mean +/- s.e.). This demonstrated that the joint angle of least pressure changed as the initial intra-articular pressure changed and there would not be a single angle of least pressure for a given joint.The volume of synovial fluid recovered from the MTP joints in trial 3 compared to 4 (trials in which fluid was injected to attain IAP of 30 mmHg) was not significantly different, supporting a soft tissue compliance change as a cause for the significant loss of intra-articular pressure during the 15 min of trial 4.The pressure profiles generated correlate well with in vivo values and demonstrated consistent pressure profiles. Our conclusions are summarised as follows:1. Clinically normal equine MTP joints which were frozen and then later thawed were found to have mostly negative baseline intra-articular pressures, as would be expected in living subjects,2. Alternate pressure profiles of the dorsal and plantar pouch at baseline intra-articular pressure document the presence of pressure forces that would support 'back and forth' fluid movement between joint compartments. This should result in movement of joint fluid during motion, assisting in lubrication and nutrition of articular cartilage,3. If joint pressure was initially greater than normal (30 mmHg), as occurs in diseased equine MTP joints, joint motion further increased joint capsule relaxation (compliance) and, therefore, reduced intra-articular pressure.4. Peak intra-articular pressures reached extremely high values (often >100 mmHg) in flexion when initial pressure was 30 mmHg. Joint effusion pressures recorded for clinical MCP joints are frequently 30 mmHg. These IAP values are expected to produce intermittent synovial ischaemia in clinical cases during joint flexion.5, Additional in vivo studies are necessary to confirm our conclusions from this study and to identify the contributions of fluid absorption and the presence of ischaemia in a vascularised joint.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The laser ablation method was used for depositing porous nanocrystalline indium-tin oxide thin films for gas sensing applications. Samples were prepared at different pressures using three gases (O-2, 0.8N(2):0.2O(2), N-2) and heat-treated in the same atmosphere used for the ablation process. X-ray diffraction results show that the films are not oriented and the grain sizes are in the range between 15 and 40 nm. The grains are round shaped for all samples and the porosity of the films increases with the deposition pressure. The degree of sintering after heat treatment increases for lower oxygen concentrations, generating fractures on the surface of the samples. Film thicknesses are in the range of I pm for all gases as determined from scanning electron microscopy cross-sections. Electrical resistance varies between 36.3 ohm for the film made at 10 Pa pressure in N-2 until 9.35 x 10(7) ohm for the film made at 100 Pa in O-2. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The rise in boiling point of grapefruit juice was experimentally measured at soluble solids concentrations in the range of 9.3-60.6 °Brix and pressures between °6.0 × 103 and 9.0 × 104 Pa. Different approaches to represent experimental data, including the Dhring's rule, the Antoine equation and empirical models proposed in the literature were tested. In the range of 9.3-29.0 °Brix, the rise in boiling point was nearly independent of pressure, varying only with juice concentration. Considerable deviations of this behavior began to occur at concentrations higher than 29.0 °Brix. Experimental data could be best predicted by adjusting an empirical model, which consisted of a single equation that takes into account the dependence of rise in boiling point on pressure and concentration. © SAGE Publications 2007.