934 resultados para PLASMA BIOCHEMICAL ANALYSIS
Resumo:
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL(-1) to 50 ng mL(-1), and the linear range was from LOQ to 500 ng mL(-1), with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
An enantioselective micromethod for the simultaneous analysis of verapamil (VER) and norverapamil (NOR) in plasma was developed, validated and applied to the study of the kinetic disposition of VER and NOR after the administration of a single oral dose of racemic-VER to rats. VER, NOR and the internal standard (paroxetine) were extracted from only 100-mu L plasma samples using n-hexane and the enantiomers were resolved on a Chiralpak AD column using n-hexane:isopropanol: ethanol: diethyl ami ne (88:6:6:0.1) as the mobile phase. The analyses were performed in the selected reaction monitoring mode. Transitions 456 > 166 for VER enantiomers, 441 > 166 for NOR enantiomers and 330 > 193 for the internal standard were monitored and the method had a total chromatographic run time of 12 min. The method allows the determination of VER and NOR enantiomers at plasma levels as low as 1.0 ng/mL. Racemic VER hydrochloride (10 mg/kg) was given to male Wistar rats by gavage and blood samples were collected from 0 to 6.0 h(n = 6 at each time point). The concentration of (-)-(S)-VER was three folds higher than (+)-(R)-VER, with an AUC ratio (-)/(+) of 2.66. Oral clearance values were 12.17 and 28.77 L/h/kg for (-)-(S)-VER and (+)-(R)-VER, respectively. The pharmacokinetic parameters of NOR were not shown to be enantioselective. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
An enantioselective high-performance liquid chromatographic method for the analysis of carvedilol in plasma and urine was developed and validated using (-)-menthyl chloroformate (MCF) as a derivatizing reagent. Chloroform was used for extraction, and analysis was performed by HPLC on a C18 column with a fluorescence detector. The quantitation limit was 0.25 ng/ml for S(-)-carvedilol in plasma and 0.5 ng/ml for R(+)-carvedilol in plasma and for both enantiomers in urine. The method was applied to the study of enantioselectivity in the pharmacokinetics of carvedilol administered in a multiple dose regimen (25mg/12h) to a hypertensive elderly female patient. The data obtained demonstrated highest plasma levels for the R(+)-carvedilol(AUCSS 75.64 vs 37.29ng/ml). The enantiomeric ratio R(+)/S(-) was 2.03 for plasma and 1.49 0 - 12 for urine (Aeo-12 17.4 vs 11.7 pg). Copyright (c) 2008 John Wiley & Sons, Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objectives were to separate canine seminal plasma proteins (with SDS-PAGE) and to determine the correlation between specific proteins and semen characteristics. Three ejaculates from 20 mixed-breed dogs, of unknown fertility, were collected by digital manipulation. Ejaculate volume and color, sperm motility, sperm vigor, percentage of morphologically normal spermatozoa, and membrane integrity (hypoosmotic swelling test and fluorescent staining) were assessed. For each dog, seminal plasma was pooled from all three ejaculates and proteins were separated with SDS-PAGE, using polyacrylamide concentrations of 13% and 22% in the separation gels. After staining, gel images were digitized to estimate molecular weights (MW) and integrated optical density (IOD) of each lane and of individual bands. Total seminal plasma protein concentration was 2.19 +/- 1.56 g/dL (mean +/- SD; range 1.12-5.19 g/dL). A total of 37 protein bands were identified (although no dog had all 37 bands). In the 13% gel, molecular weights ranged from 100.6 to 17.1 kDa, with four bands (49.7, 33.2, 26.4, and 19.5 kDa) present in samples from all dogs. In the 22% gel, molecular weights ranged from 15.6 to 3.6 kDa, with nine bands (15.6, 13.5, 12.7, 11.7, 10.5, 8.7, 7.8, 5.6, and 4.9 kDa) present in samples from all dogs. Combined for both gels, the majority of bands (85%) had molecular weights < 17 kDa, with B20 (15.6 kDa) in high concentrations in samples from all dogs. There were positive correlations (P <= 0.01) between two bands, 134 (67 kDa) and B5 (58.6 kDa), and sperm motility (r = 0.66 and r = 0.46), sperm vigor (r = 0.56 and r = 0.66), percentage of morphologically normal spermatozoa (r = 0.55 and r = 0.59), the hypoosmotic swelling test (r = 0.76 and r 0.68), and fluorescent staining (r = 0.56 and r = 0.59), respectively. In conclusion, 37 proteins were identified in seminal plasma; two were significantly correlated with semen characteristics. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Objective-To establish reference intervals for cytologic and biochemical variables in peritoneal fluid, whole blood, and plasma in calves with congenital umbilical hernias (CUHs) before and after herniorrhaphy and to assess whether those variables in calves with CUHs were altered, compared with findings in clinically normal calves.Animals-20 Holstein calves with or without a CUH.Procedures-10 calves with CUHs underwent herniorrhaphy. Blood and peritoneal fluid samples from all 20 calves were collected for cytologic and biochemical analyses on days 0 (before surgery), 1, 3, 5, 7, and 15. Data from the 2 groups were compared.Results-Reference intervals for the variables of interest were established for each group, Before surgery, calves with CUHs had significantly greater plasma total protein concentration and creatine kinase (CK) and aspartate aminotransferase activities and peritoneal fluid specific gravity values, compared with values for calves without CUHs. At various time points after surgery, peritoneal fluid total protein concentration; fibrinogen concentration; nucleated cell, polymorphonuclear cell, and lymphocyte counts; specific gravity; and lactate dehydrogenase, aspartate aminotransferase, and CK activities in calves with CUHs were significantly different from values in calves without CUHs. Some plasma and blood variables leg, total protein concentration, neutrophil count, and CK activity were significantly different between the 2 groups.Conclusions and Clinical Relevance-Values of certain cytologic and biochemical variables in peritoneal fluid, blood, and plasma were different between calves with and without CUHs. Thus, determination of reference intervals for these variables is important for interpreting diagnostic test results in calves with CUHs. (Am J Vet Res 2009;70:423-432)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of the present study was to evaluate the outcomes of autogenous bone graft (AB) and bioglass (BG) associated or not with leukocyte-poor platelet-rich plasma (LP-PRP) in the rabbit maxillary sinus (MS) by histomorphometric and radiographic analysis. Twenty rabbits divided into 2 groups (G1, G2) were submitted to sinus lift surgery. In G1, 10 MS were grafted with AB and 10 MS were grafted with BG. In G2, 10 MS were grafted with AB + LP-PRP and 10 MS were grafted with BG + LP-PRP. After 90 days, the animals were killed and specimens were obtained, x-rayed, and submitted to histomorphometric, radiographic bone density (RD) and fractal dimension analysis. Radiographic bone density mean values (SD), expressed as aluminum equivalent in mm, of AB, BG, AB + LP-PRP, and BG + LP-PRP groups were 1.79 (0.31), 2.04 (0.39), 1.61 (0.28), and 1.53 (0.30), respectively. Significant differences (P < 0.05) were observed between BG and AB, and BG + PRP and BG. Fractal dimension mean values were 1.48 (0.04), 1.35 (0.08), 1.44 (0.04), and 1.44 (0.06), respectively. Significant differences were observed between BG and AB, and AB + LP-PRP and BG. Mean values for the percentage of bone inside MS were 63.30 (8.60), 52.65 (10.41), 55.25 (7.01), and 51.07 (10.25), respectively. No differences were found. No correlations were observed among percentage of bone, RD and FD. Histological analysis showed that MS treated with AB presented mature and new bone formation. The other groups showed minor bone formation. Within the limitations of this study, the results indicated that at a 90-day time end point, AB yielded better results than AB + LP-PRP, BG, and BG + LP-PRP and should be considered the primary material for MS augmentation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these strains came as clinical samples, 4% isolated from frogs and 35% as environmental samples. Mycobacterium tuberculosis strains identified by classical methods were confirmed by their mycolic acids contents (I, III and IV). The method allowed earlier differentiation of M. avium complex - MAC (mycolic acids I, IV and VI) from M. simiae (acids I, II and IV), both with similar biochemical properties. The method also permitted to distinguish M. fortuitum (acids I and V) from M. chelonae (acids I and II) , and to detect mixed mycobacterial infections cases as M. tuberculosis with MAC and M. fortuitum with MAC. Concluding, four years experience shows that mycolic acids TLC is an easy, reliable, fast and inexpensive method, an important tool to put together conventional mycobacteria identification methods.
Resumo:
The use of Saccharomyces cerevisiae as a substrate to selectively retain Sn(II) and Sn(IV) has been investigated. Several factors affecting the retention of the analytes by yeast, such as pH, amount of biomass, temperature and time of contact were evaluated. Based on this study, a method for determination of Sn(II) and Sn(IV) combining inductively coupled plasma optical emission spectrometry (ICP OES) and solid phase extraction using Saccharomyces cerevisiae is proposed. The procedure consists of the selective retention of Sn(IV) by yeast at pH = 2.0 while Sn(II) remains in solution. Determination of tin in the solid phase was easily carried out by submitting a slurry of the yeast (0.5 g/40 mL) directly to ICP OES. The precision of the extraction procedure was characterized by an RSD lower than 4%. The detection limits of tin (3 sigma) in the solid phase and the liquid phase were 1.1 and 0.7 mu g L-1, respectively. The proposed approach was evaluated for determination of Sn(II) and Sn(IV) in spiked river water and real samples of industrial waste water (untreated and treated). For all samples, recoveries of spiked Sn(II) and Sn(IV) were between 85 and 112%.
Resumo:
Background Diet composition is one of the factors that may contribute to intraindividual variability in the anticoagulant response to warfarin. Aim of the study To determine the associations between food pattern and anticoagulant response to warfarin in a group of Brazilian patients with vascular disease. Methods Recent and usual food intakes were assessed in 115 patients receiving warfarin; and corresponding plasma phylloquinone (vitamin K-1), serum triglyceride concentrations, prothrombin time (PT), and International Normalized Ratio (INR) were determined. A factor analysis was used to examine the association of specific foods and biochemical variables with anticoagulant data. Results Mean age was 59 +/- 15 years. Inadequate anticoagulation, defined as values of INR 2 or 3, was found in 48% of the patients. Soybean oil and kidney beans were the primary food sources of phylloquinone intake. Factor analysis yielded four separate factors, explaining 56.4% of the total variance in the data set. The factor analysis revealed that intakes of kidney beans and soybean oil, 24-h recall of phylloquinone intake, PT and INR loaded significantly on factor 1. Triglycerides, PT, INR, plasma phylloquinone, and duration of anticoagulation therapy loaded on factor 3. Conclusion Fluctuations in phylloquinone intake, particularly from kidney beans, and plasma phylloquinone concentrations were associated with variation in measures of anticoagulation (PT and INR) in a Brazilian group of patients with vascular disease.
Resumo:
The feasibility of Portland cement analysis by introduction of slurries in an inductively coupled plasma optical emission spectrometer (ICP-OES) with axial viewing has been evaluated. After a fast manual grinding of the cement samples, owing to the pulverized state of this material, 0.1% m/v slurries were prepared in 1% v/v HCl. The calibration was performed adopting two strategies: one based on slurries prepared from different masses (50, 75, 100 and 125 mg) of a Portland cement standard reference material (NIST SRM 1881), and the other one based on aqueous reference solutions. A complete analysis of cement for major (Al, Ca, Fe, Mg and Si), minor and trace elements (Mn, P, S, Sr and Ti) was accomplished. Both strategies led to accurate results for commercial Portland cement samples, except for Si and Ti. for which the calibration with aqueous reference solutions resulted in low values. Applying a paired t-test it was shown that most results were in agreement at a 95% confidence level with a conventional fusion decomposition procedure. The ICP-OES with axial viewing and end-on gas configuration for removal of the recombination plasma zone was effective for cement slurry analysis without any undesirable particle deposition in the pre-optics interface and without severe spectral interferences. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)