890 resultados para PINCH TECHNIQUE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to improve the mass rearing technique of Euschistus heros in laboratory. Nymphs and adults were reared at densities 100, 200, 300 and 400 eggs per Petri dish (9 cm diameter), and at 50, 100, 150 and 200 couples per rearing cages (900 mL), respectively. Survival rate of immature stages and survivorship and reproduction of adults were determinated. Survivorship of nymph to adult was the highest (89%) at density 100 eggs per dish. Adult survivorship was independent of density, and 100 couples per cage were the best to improve quality of the produced progeny. In these conditions, fecundity was 160.8±9.28 eggs per female, and a total of 8,950±456 eggs per cage per month was produced. Two hundred couples per cage showed a negative effect on reproduction, which decreased to 65%. With this technique, a colony of 35 cages with 100 couples per cage yields about 313.3 thousands eggs per month, which is enough to supply the egg parasitoid Telenomus podisi to colonize about 35 ha of soybean field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report magnetic and magneto-optical measurements of two Mn12 single-molecule magnet derivatives isolated in organic glasses. Field-dependent magnetic circular dichroism (MCD) intensity curves (hysteresis cycles) are found to be essentially identical to superconducting quantum interference device magnetization results and provide experimental evidence for the potential of the optical technique for magnetic characterization. Optical observation of magnetic tunneling has been achieved by studying the decay of the MCD signal at weak applied magnetic field

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual implant elastomer (VIE) has recently been employed to investigate different aspects of earthworm ecology. However, a number of fundamental questions relating to the detection and positioning of the tag, its persistence and potential effects on earthworms remain unknown. Seven earthworm species belonging to three ecological groupings, with different pigmentation and burrowing behaviour, were tagged using different coloured VIE. External inspection after two days, one week and 1, 10 and 27 months were followed by preservation, dissection and internal inspection. Tags could be seen in living specimens to 27 months, and dissection revealed that in most cases they were lodged in the coelomic cavity, held in place by septa. However, over longer time periods (more than two years), the chlorogogenous tissue tended to bind to the tags and made external observation increasingly difficult. Migration of the VIE material towards the posterior of the earthworm and potential loss of the tag were only observed on rare occasions, and a recovery rate in excess of 98% was recorded. By introducing a reasonable amount of VIE into segments, just after the clitellum, this technique can become a valuable tool in earthworm ecology and life history studies, particularly in short-medium term laboratory and field experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Process variations are a major bottleneck for digital CMOS integrated circuits manufacturability and yield. That iswhy regular techniques with different degrees of regularity are emerging as possible solutions. Our proposal is a new regular layout design technique called Via-Configurable Transistors Array (VCTA) that pushes to the limit circuit layout regularity for devices and interconnects in order to maximize regularity benefits. VCTA is predicted to perform worse than the Standard Cell approach designs for a certain technology node but it will allow the use of a future technology on an earlier time. Ourobjective is to optimize VCTA for it to be comparable to the Standard Cell design in an older technology. Simulations for the first unoptimized version of our VCTA of delay and energy consumption for a Full Adder circuit in the 90 nm technology node are presented and also the extrapolation for Carry-RippleAdders from 4 bits to 64 bits.