917 resultados para PASSIVE WAVE-GUIDES
Resumo:
Using the transit pulse method, we have determined compressional wave velocities of rocks from various geological units belonging to the Penninic zone along the NFP20-West profiles of the Swiss western Alps. The velocities have been measured at confining pressures up to 400 MPa, along three orthogonal axes defined by the macrostructure of the rocks. The samples analysed show a degree of metamorphism ranging from greenschist to eclogite facies. This collection includes schists, dolomites, gneisses and ophiolitic rocks. The mean velocities range from 5.9 km/s for a quartzitic calcschist to 7.9 km/s for an eclogitic metagabbro. The velocity anisotropy is as high as 20 %. The range of acoustic impedance is wide, from 15 to 27 10(6) kg/m2s. From these measurements, normal incident reflection coefficients for likely rock assemblages within and between geological units were estimated in order to interpret zone of the strong reflections recorded along the seismic profiles. Reflection coefficients as high as 0.17 could be determined.
Resumo:
Evolution of the Red Sea/Gulf of Suez and the Central Atlantic rift systems shows that an initial, transtensive rifting phase, affecting a broad area around the future zone of crustal separation, was followed by a pre-oceanic rifting phase during which extensional strain was concentrated on the axial rift zone. This caused lateral graben systems to become inactive and they evolved into rift-rim basins. The transtensive phase of diffuse crustal extension is recognized in many intra-continental rifts. If controlling stress systems relax, these rifts abort and develop into palaeorifts. If controlling stress systems persist, transtensive rift systems can enter the pre-oceanic rifting stage, during which the rift zone narrows and becomes asymmetric as a consequence of simple-shear deformation at shallow crustal levels and pure shear deformation at lower crustal and mantle-lithospheric levels. Preceding crustal separation, extensional denudation of the lithospheric mantle is possible. Progressive lithospheric attenuation entails updoming of the asthenosphere and thermal doming of the rift shoulders. Their uplift provides a major clastic source for the rift basins and the lateral rift-rim basins. Their stratigraphic record provides a sensitive tool for dating the rift shoulder uplift. Asymmetric rifting leads to the formation of asymmetric continental margins, corresponding in a simple-shear model to an upper plate and a conjugate lower plate margin, as seen in the Central Atlantic passive margins of the United States and Morocco. This rifting model can be successfully applied to the analysis of the Alpine Tethys palaeo-margins (such as Rif and the Western Alps).
Resumo:
We present the optical properties of Na0.7CoO2 single crystals, measured over a broad spectral range as a function of temperature (T). The capability to cover the energy range from the far-infrared up to the ultraviolet allows us to perform reliable Kramers-Kronig transformation, in order to obtain the absorption spectrum (i.e., the complex optical conductivity). To the complex optical conductivity we apply the generalized Drude model, extracting the frequency dependence of the scattering rate (Gamma) and effective mass (m*) of the itinerant charge carriers. We find that Gamma(omega) at low temperatures and for similar to omega. This suggests that Na0.7CoO2 is at the verge of a spin-density-wave metallic phase.
T-wave alternans predicts mortality in a population undergoing a clinically indicated exercise test.
Resumo:
Eur Heart J. 2007 Oct;28(19):2332-7. Epub 2007 Jul 25.
Resumo:
An accidental burst of a pressure vessel is an uncontrollable and explosion-like batch process. In this study it is called an explosion. The destructive effectof a pressure vessel explosion is relative to the amount of energy released in it. However, in the field of pressure vessel safety, a mutual understanding concerning the definition of explosion energy has not yet been achieved. In this study the definition of isentropic exergy is presented. Isentropic exergy is the greatest possible destructive energy which can be obtained from a pressure vessel explosion when its state changes in an isentropic way from the initial to the final state. Finally, after the change process, the gas has similar pressure and flow velocity as the environment. Isentropic exergy differs from common exergy inthat the process is assumed to be isentropic and the final gas temperature usually differs from the ambient temperature. The explosion process is so fast that there is no time for the significant heat exchange needed for the common exergy.Therefore an explosion is better characterized by isentropic exergy. Isentropicexergy is a characteristic of a pressure vessel and it is simple to calculate. Isentropic exergy can be defined also for any thermodynamic system, such as the shock wave system developing around an exploding pressure vessel. At the beginning of the explosion process the shock wave system has the same isentropic exergyas the pressure vessel. When the system expands to the environment, its isentropic exergy decreases because of the increase of entropy in the shock wave. The shock wave system contains the pressure vessel gas and a growing amount of ambient gas. The destructive effect of the shock wave on the ambient structures decreases when its distance from the starting point increases. This arises firstly from the fact that the shock wave system is distributed to a larger space. Secondly, the increase of entropy in the shock waves reduces the amount of isentropic exergy. Equations concerning the change of isentropic exergy in shock waves are derived. By means of isentropic exergy and the known flow theories, equations illustrating the pressure of the shock wave as a function of distance are derived. Amethod is proposed as an application of the equations. The method is applicablefor all shapes of pressure vessels in general use, such as spheres, cylinders and tubes. The results of this method are compared to measurements made by various researchers and to accident reports on pressure vessel explosions. The test measurements are found to be analogous with the proposed method and the findings in the accident reports are not controversial to it.
Resumo:
One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.
Resumo:
INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.
Resumo:
Hydrogenated amorphous silicon (a‐Si:H) thin films have been obtained from pure SiH4 rf discharges by using the square wave modulation (SQWM) method. Film properties have been studied by means of spectroellipsometry, thermal desorption spectrometry, photothermal deflection spectroscopy and electrical conductivity measurements, as a function of the modulation frequency of the rf power amplitude (0.2-4000 Hz). The films deposited at frequencies about 1 kHz show the best structural and optoelectronic characteristics. Based upon the experimental results, a qualitative model is presented, which points up the importance of plasma negative ions in the deposition of a‐Si:H from SQWM rf discharges through their influence on powder particle formation.
Resumo:
BACKGROUND: Studies in bipolar disorder (BD) to date are limited in their ability to provide a whole-disease perspective--their scope has generally been confined to a single disease phase and/or a specific treatment. Moreover, most clinical trials have focused on the manic phase of disease, and not on depression, which is associated with the greatest disease burden. There are few longitudinal studies covering both types of patients with BD (I and II) and the whole course of the disease, regardless of patients' symptomatology. Therefore, the Wide AmbispectiVE study of the clinical management and burden of Bipolar Disorder (WAVE-bd) (NCT01062607) aims to provide reliable information on the management of patients with BD in daily clinical practice. It also seeks to determine factors influencing clinical outcomes and resource use in relation to the management of BD. METHODS: WAVE-bd is a multinational, multicentre, non-interventional, longitudinal study. Approximately 3000 patients diagnosed with BD type I or II with at least one mood event in the preceding 12 months were recruited at centres in Austria, Belgium, Brazil, France, Germany, Portugal, Romania, Turkey, Ukraine and Venezuela. Site selection methodology aimed to provide a balanced cross-section of patients cared for by different types of providers of medical aid (e.g. academic hospitals, private practices) in each country. Target recruitment percentages were derived either from scientific publications or from expert panels in each participating country. The minimum follow-up period will be 12 months, with a maximum of 27 months, taking into account the retrospective and the prospective parts of the study. Data on demographics, diagnosis, medical history, clinical management, clinical and functional outcomes (CGI-BP and FAST scales), adherence to treatment (DAI-10 scale and Medication Possession Ratio), quality of life (EQ-5D scale), healthcare resources, and caregiver burden (BAS scale) will be collected. Descriptive analysis with common statistics will be performed. DISCUSSION: This study will provide detailed descriptions of the management of BD in different countries, particularly in terms of clinical outcomes and resources used. Thus, it should provide psychiatrists with reliable and up-to-date information about those factors associated with different management patterns of BD. TRIAL REGISTRATION NO: ClinicalTrials.gov: NCT01062607.
Resumo:
In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.
Resumo:
In der Schweiz, wie in vielen anderen Ländern, ist die Durchimpfungsrate zu tief, um die Verbreitung von Masern zu stoppen. Es kommt immer wieder zu Masern-Ausbrüchen. Die Gabe von Immunglobulinen (Passivimpfung) ist für nicht-immune Personen gedacht, die Kontakt zu Masernvirus-Ausscheidern hatten. Sie wird in der Schweiz für Hochrisiko-Personen wie z.B. schwangere Frauen, immunsupprimierte Personen und Säuglinge <6 Monate ohne nachgewiesene Immunität empfohlen. Schätzungen über die Wirksamkeit der Passivimpfung variieren; es wurde keine minimalwirksame Dosierung festgelegt. Ziel dieses Reviews war, die Wirksamkeit und Sicherheit einer intramuskulären oder intravenösen Gabe von Immunglobulinen zur Masern-Prophylaxe nach Exposition jedoch vor Symptombeginn bei für Masern empfänglichen Personen zu untersuchen.
Resumo:
[spa] En este trabajo se analiza la relación entre la heterogeneidad étnica y la redistribución, utilizando la reciente y masiva llegada de inmigrantes a España. En concreto, se estudia el efecto de los cambios en la densidad de inmigrantes, observada entre 1998 y 2006, sobre los cambios en el gasto social municipal. La densidad de inmigrantes se instrumenta utilizando los patrones de establecimiento por país de origen para asignar los flujos predichos de inmigrantes a cada municipio. Los resultados evidencian que el gasto social incrementó menos en los municipios con mayores incrementos en la densidad de inmigrantes. También se proporciona evidencia de la existencia de una relación positiva entre la densidad de inmigrantes y el porcentaje de voto obtenidos por los partidos de derecha. Por tanto, estos resultados son consistentes con las teorías que predicen una relación negativa entre la heterogeneidad étnica y la redistribución.
Resumo:
[spa] En este trabajo se analiza la relación entre la heterogeneidad étnica y la redistribución, utilizando la reciente y masiva llegada de inmigrantes a España. En concreto, se estudia el efecto de los cambios en la densidad de inmigrantes, observada entre 1998 y 2006, sobre los cambios en el gasto social municipal. La densidad de inmigrantes se instrumenta utilizando los patrones de establecimiento por país de origen para asignar los flujos predichos de inmigrantes a cada municipio. Los resultados evidencian que el gasto social incrementó menos en los municipios con mayores incrementos en la densidad de inmigrantes. También se proporciona evidencia de la existencia de una relación positiva entre la densidad de inmigrantes y el porcentaje de voto obtenidos por los partidos de derecha. Por tanto, estos resultados son consistentes con las teorías que predicen una relación negativa entre la heterogeneidad étnica y la redistribución.
Resumo:
n this work we analyze the behavior of complex information in Fresnel domain taking into account the limited capability to display complex transmittance values of current liquid crystal devices, when used as holographic displays. In order to do this analysis we compute the reconstruction of Fresnel holograms at several distances using the different parts of the complex distribution (real and imaginary parts, amplitude and phase) as well as using the full complex information adjusted with a method that combines two configurations of the devices in an adding architecture. The RMS error between the amplitude of these reconstructions and the original amplitude is used to evaluate the quality of the information displayed. The results of the error analysis show different behavior for the reconstructions using the different parts of the complex distribution and using the combined method of two devices. Better reconstructions are obtained when using two devices whose configurations densely cover the complex plane when they are added. Simulated and experimental results are also presented.