883 resultados para ORTHOPAEDIC FIXATION DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current technology trends in medical device industry calls for fabrication of massive arrays of microfeatures such as microchannels on to nonsilicon material substrates with high accuracy, superior precision, and high throughput. Microchannels are typical features used in medical devices for medication dosing into the human body, analyzing DNA arrays or cell cultures. In this study, the capabilities of machining systems for micro-end milling have been evaluated by conducting experiments, regression modeling, and response surface methodology. In machining experiments by using micromilling, arrays of microchannels are fabricated on aluminium and titanium plates, and the feature size and accuracy (width and depth) and surface roughness are measured. Multicriteria decision making for material and process parameters selection for desired accuracy is investigated by using particle swarm optimization (PSO) method, which is an evolutionary computation method inspired by genetic algorithms (GA). Appropriate regression models are utilized within the PSO and optimum selection of micromilling parameters; microchannel feature accuracy and surface roughness are performed. An analysis for optimal micromachining parameters in decision variable space is also conducted. This study demonstrates the advantages of evolutionary computing algorithms in micromilling decision making and process optimization investigations and can be expanded to other applications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shadow masks are used in manufacturing processes for electro-optic devices to transfer patterns with different shapes and dimensions. For fabrication of organic based devices, shadow masks should be made of materials stable against organic solvents, high temperature, and robust, remaining unchanged after multiple cycles of use and fixation. Thus, stainless steel is suitable for shadow masks. A simple, cheap and quick method of obtaining shadow masks by electrochemical corrosion of stainless steel is reported. The shadow mask was used to evaporate cathode material to obtain an organic light emitting diode with active area of 9 mm². This device exhibited a turn-on voltage of 5 V and luminance of 14 cd/m².

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this thesis was to study how certificates could be used to improve security of mobile devices. In the theoretical part the usage of certificates to improve security is explained. In the practical part a concept of certificate handling middleware is introduced and implemented. This is to demonstrate what kind of functionality is needed to provide an improvement over the current situation in security with mobile devices. The certificate handling middleware is a concept that would work better if implemented directly into mobile device's core functionality. Many of the mobile devices have a certificate store to some degree and often it is not used to store other people's certificates. A certificate store combined with address book and added with possibility to add attributes to the people such as group memberships would be sufficient to satisfy the needs of many emerging sharing and social applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis discusses the design and implementation of a real-time musical pair improvisation scenario for mobile devices. In the scenario transferring musical information over a network connection was required. The suitability of available wireless communication technologies was evaluated and communication was analyzed and designed on multiple layers of TCP/IP protocol stack. Also an application layer protocol was designed and implemented for the scenario. The implementation was integrated into a mobile musical software for children using available software components and libraries although the used platform lead to hardware and software constraints. Software limitations were taken into account in design. The results show that real-time musical improvisation can be implemented with wireless communication and mobile technology. The results also show that link layer had the most significant effect on real-time communication in the scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiostereometric analysis (RSA) is a highly accurate method for the measurement of in vivo micromotion of orthopaedic implants. Validation of the RSA method is a prerequisite for performing clinical RSA studies. Only a limited number of studies have utilised the RSA method in the evaluation of migration and inducible micromotion during fracture healing. Volar plate fixation of distal radial fractures has increased in popularity. There is still very little prospective randomised evidence supporting the use of these implants over other treatments. The aim of this study was to investigate the precision, accuracy, and feasibility of using RSA in the evaluation of healing in distal radius fractures treated with a volar fixed-angle plate. A physical phantom model was used to validate the RSA method for simple distal radius fractures. A computer simulation model was then used to validate the RSA method for more complex interfragmentary motion in intra-articular fractures. A separate pre-clinical investigation was performed in order to evaluate the possibility of using novel resorbable markers for RSA. Based on the validation studies, a prospective RSA cohort study of fifteen patients with plated AO type-C distal radius fractures with a 1-year follow-up was performed. RSA was shown to be highly accurate and precise in the measurement of fracture micromotion using both physical and computer simulated models of distal radius fractures. Resorbable RSA markers demonstrated potential for use in RSA. The RSA method was found to have a high clinical precision. The fractures underwent significant translational and rotational migration during the first two weeks after surgery, but not thereafter. Maximal grip caused significant translational and rotational interfragmentary micromotion. This inducible micromotion was detectable up to eighteen weeks, even after the achievement of radiographic union. The application of RSA in the measurement of fracture fragment migration and inducible interfragmentary micromotion in AO type-C distal radius fractures is feasible but technically demanding. RSA may be a unique tool in defining the progress of fracture union.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Along with the increasing in demand of mobile computing, Push Notification (PN) is widely used in mobile phones and other devices. PN allows the developer to send messages to the end users even when the client application is not running at the moment. This solves the problem produced by non-supported multi-tasking feature as well as saving battery life. Microsoft Push Notification Service (MPNS) is one solution to use PNs in Windows Phones. The thesis gives the developers an idea of how to use PNs by introducing MPNS, comparing MPNS with other Push Notification Services, usage of different PN types analysis, and PN simulation system implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tiedollista voimavaraistumista tukeva internet-perustainen ohjaus päiväkirurgisille ortopedisille potilaille Tutkimuksen tarkoituksena oli kehittää tiedollista voimavaraistumista tukeva Internetperustainen potilasohjausohjelma sekä arvioida sitä. Tutkimusprosessi jaettiin kahteen vaiheeseen. Ensimmäisessä vaiheessa luotiin sisältö tiedollista voimavaraistumista tukevalle Internet-perustaiselle ohjaukselle päiväkirurgisia ortopedisia potilaita varten. Toisessa vaiheessa arvioitiin Internet-perustaisen ohjauksen (koeryhmä) hyväksyttävyyttä käyttäjien arvioimana ja ohjauksen tuloksia sekä verrattiin Internet-perustaisen ohjauksen (koeryhmä) tuloksia tiedollisesti voimavaraistumista tukevan sairaanhoitajan välittämään ohjauksen (kontrolliryhmä) tuloksiin. Tutkimuksen tavoitteena oli luoda uusi potilasohjausmuoto joka tarjoaa yksilöllisen, osallistavan ja aikaan ja paikkaan sitomattoman ohjauksen päiväkirurgiseen ortopediseen leikkaukseen tulevalle potilaalle. Tutkimuksen ensimmäisessä vaiheessa käytettiin kuvailevaa ja vertailevaa tutkimusmenetelmää (ennen ja jälkeen testaus). Tutkimukseen osallistui 120 päiväkirurgista ortopedista potilasta joiden tiedon odotuksia ja heille välitettyä tietoa tarkasteltiin. Tutkimuksen ensimmäisen vaiheen tuloksien ja aikaisemman voimavaraistumista käsittävän tiedon perusteella luotiin sisältö tiedollista voimavaraistumista tukevalle Internet-perustaiselle ohjaukselle. Sisältö rakentui voimavaraistavan tiedon kuudesta eri osa-alueesta. Tutkimuksen toisessa vaiheessa käytettiin randomoitua kokeellista tutkimusasetelmaa. Päiväkirurgiseen ortopediseen leikkaukseen tulevat potilaat randomoitiin koeryhmään (n=72) Internetperustaiseen ohjaukseen ja kontrolliryhmään (n=75) sairaanhoitajan välittämään ohjaukseen. Aineisto kerättiin strukturoitujen mittareiden avulla ja tulokset analysoitiin tilastollisesti. Tutkimuksen tulokset osoittavat, että kehitettyä tiedollisesti voimavaraistumista tukevaa Internet-perustaista potilasohjausmenetelmää voidaan suositella käytettäväksi ortopedisten päiväkirurgisten potilaiden ohjauksessa ja potilailla on hyvät mahdollisuudet voimavaraistua tiedollisesti sen avulla. Monipuolista tietoa sisältävä Internet-perustainen ohjaus osoittautui käyttäjien näkökulmasta hyväksyttäväksi. Vaikka Internet ohjauksen hyväksyttävyys koettiin osittain heikommaksi kuin sairaanhoitajan välittämän ohjauksen, potilaat käyttivät nettisivustoa ongelmitta ja arvioivat sen helppokäyttöiseksi. Ohjausmuodolla ei ollut vaikutusta hoidosta aiheutuneisiin kustannuksiin. Sen sijaan kustannuksista organisaatiolle voitiin puolittaa sairaanhoitajan ohjaukseen käyttämä aika Internet-perustaisen ohjauksen avulla. Internet-perustaiseen ohjaukseen osallistuneiden potilaiden tiedon taso ja kokemus tiedon riittävyydestä lisääntyivät ohjauksen jälkeen enemmän kuin sairaanhoitajan välittämään potilasohjaukseen osallistuneiden potilaiden tiedot. Ohjausmuodolla ei ollut vaikutusta potilaiden kokemien tunteiden ja oireiden voimakkuuteen. Yhteenvetona voidaan todeta, että tiedollisesti voimavaraistava Internet-perustaista ohjausta voidaan suositella vaihtoehtoiseksi menetelmäksi sairaanhoitajan välittämälle ohjaukselle päiväkirurgiseen ortopediseen leikkaukseen tuleville potilaille.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proportion of elderly people over 65 years of age in Finland is expected to grow to over 25% by the 2025. It has been estimated that elderly people today consume nearly 40% of all drugs. Age brings about number of physiological changes that may affect the disposition, metabolism and excretion of drugs. The function of heart, lungs, liver and kidneys decreases even in healthy people, as they get older. The proportion of total body water decreases and the relative fat percentage increases. Also several other factors such as concurrent diseases, concomitant medication and nutritional factors have an effect on drug therapy in elderly. Age increases the risk of adverse drug reactions, which most often are dose-dependent. Despite all this there are not enough studies involving the elderly people and the elderly are most often excluded from clinical trials. Oxycodone is a strong opioid analgesic, which is used to treat moderate or severe pain. Paracetamol is a widely used nonopioid analgesic, which has become popular in the treatment of pain in many patient groups. In this series of studies the pharmacokinetics of oral and intravenous oxicodone as well as intravenous paracetamol in the elderly and young adult patients were investigated. Also a study investigating the interaction of oral antibiotic clarityhromycin, a known cytochrome P450 (CYP) 3A4 inhibitor, with oxycodone pharmacokinetics and pharmacodynamics in elderly and young healthy volunteers was carried out. The pharmacokinetics of oxycodone showed a clear age depency. Patients over 70 years had 50-80% higher mean exposure to oral oxycodone and a twofold greater plasma concentration than young adults 12 h after ingestion of the drug. Elderly patients had 40-80% greater exposure to intravenous oxycodone and patients over 80 years had over twofold greater plasma concentrations 8 h post dose than the young adults. The elderly patients had also greater exposure to intra venous paracetamol compared to young adults. Clarithromycin increased the exposure to oral oxycodone in both young and elderly volunteers. The elderly had marked interindividual variation in the pharmacokinetics and pharmacodynamics when clarithromycin was given concomitantly with oxycodone. Because the pharmacokinetics of oxycodone and intravenous paracetamol depend on the age of the subject, it is important to titrate the analgesic dose individually in the elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The forthcoming media revolution of exchanging paper documents to digital media in construction engineering requires new tools to be developed. The basis of this bachelor’s thesis was to explore the preliminary possibilities of exporting imagery from a Building Information Modelling –software to a mobile phone on a construction yard. This was done by producing a Web Service which uses the design software’s Application Programming Interface to interact with a structures model in order to produce the requested imagery. While mobile phones were found lacking as client devices, because of limited processing power and small displays, the implementation showed that the Tekla Structures API can be used to automatically produce various types of imagery. Web Services can be used to transfer this data to the client. Before further development the needs of the contractor, benefits for the building master and inspector and the full potential of the BIM-software need to be mapped out with surveys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the compliance and degree of satisfaction of nulligravida (has not given birth) and parous (had already given birth) women who are using intrauterine devices (IUDs). Methods A cross-sectional cohort study was conducted comparing nulligravida and parous women who had had an IUD inserted between July 2009 and November 2011. A total of 84 nulligravida women and 73 parous women were included. Interviews were conducted with women who agreed to participate through telephone contact. Statistical analysis was performed with Student s t-test and Mann-Whitney test for numeric variables; Pearson s chi-square test to test associations; and, whenever pertinent, Fisher s exact test for categorical variables. A survival curve was constructed to estimate the likelihood of each woman continuing the use of the IUD. A significance level of 5% was established. Results When compared with parous women, nulligravida women had a higher education level (median: 12 vs. 10 years). No statistically significant differences were found between the nulligravida and parous women with respect to information on the use of the IUD, prior use of other contraceptive methods, the reason for having chosen the IUD as the current contraceptive method, reasons for discontinuing the use and adverse effects, compliance, and degree of satisfaction. The two groups did not show any difference in terms of continued use of the IUD (p = 0.4). Conclusion There was no difference in compliance or the degree of satisfaction or continued use of IUDs between nulligravida and parous women, suggesting that IUD use may be recommended for women who have never been pregnant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranial bone reconstructions are necessary for correcting large skull bone defects due to trauma, tumors, infections and craniotomies. Traditional synthetic implant materials include solid or mesh titanium, various plastics and ceramics. Recently, biostable glass-fiber reinforced composites (FRC), which are based on bifunctional methacrylate resin, were introduced as novel implant solution. FRCs were originally developed and clinically used in dental applications. As a result of further in vitro and in vivo testing, these composites were also approved for clinical use in cranial surgery. To date, reconstructions of large bone defects were performed in 35 patients. This thesis is dedicated to the development of a novel FRC-based implant for cranial reconstructions. The proposed multi-component implant consists of three main parts: (i) porous FRC structure; (ii) bioactive glass granules embedded between FRC layers and (iii) a silver-polysaccharide nanocomposite coating. The porosity of the FRC structure should allow bone ingrowth. Bioactive glass as an osteopromotive material is expected to stimulate the formation of new bone. The polysaccharide coating is expected to prevent bacterial colonization of the implant. The FRC implants developed in this study are based on the porous network of randomly-oriented E-glass fibers bound together by non-resorbable photopolymerizable methacrylate resin. These structures had a total porosity of 10–70 volume %, of which > 70% were open pores. The pore sizes > 100 μm were in the biologically-relevant range (50-400 μm), which is essential for vascularization and bone ingrowth. Bone ingrowth into these structures was simulated by imbedding of porous FRC specimens in gypsum. Results of push-out tests indicated the increase in the shear strength and fracture toughness of the interface with the increase in the total porosity of FRC specimens. The osteopromotive effect of bioactive glass is based on its dissolution in the physiological environment. Here, calcium and phosphate ions, released from the glass, precipitated on the glass surface and its proximity (the FRC) and formed bone-like apatite. The biomineralization of the FRC structure, due to the bioactive glass reactions, was studied in Simulated Body Fluid (SBF) in static and dynamic conditions. An antimicrobial, non-cytotoxic polysaccharide coating, containing silver nanoparticles, was obtained through strong electrostatic interactions with the surface of FRC. In in vitro conditions the lactose-modified chitosan (chitlac) coating showed no signs of degradation within seven days of exposure to lysozyme or one day to hydrogen peroxide (H2O2). The antimicrobial efficacy of the coating was tested against Staphylococcus aureus and Pseudomonas aeruginosa. The contact-active coating had an excellent short time antimicrobial effect. The coating neither affected the initial adhesion of microorganisms to the implant surface nor the biofilm formation after 24 h and 72 h of incubation. Silver ions released to the aqueous environment led to a reduction of bacterial growth in the culture medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the contact resistance of graphene devices was investigated because high contact resistance is detrimental to the performance of graphene field-effect transistors (GFET). Method for increasing so-called edge-contact area was applied in device fabrication process, as few nanometers thick Ni layer was used as a catalytic etchant during the annealing process. Finally, Ni was also used as a metal for contact. GFETs were fabricated using electron beam lithography using graphene fabricated by chemical vapor deposition (CVD). Critical part of the fabrication process was to preserve the high quality of the graphene channel while etching the graphene at contact areas with Ni during the annealing. This was achieved by optimizing the combination of temperature and gas flows. The structural properties of graphene were studied using scanning electron microscopy, scanning confocal μ-Raman spectroscopy and optical microscopy. Evaluation of electric transport properties including contact resistance was carried out by transmission line method and four-probe method. The lowest contact resistance found was about at 350 Ωμm. In addition, different methods to transfer CVD graphene synthesized on copper were studied. Typical method using PMMA as a supporting layer leaves some residues after its removal, thus effecting on the performance of a graphene devices. In a metal assisted transfer method, metal is used as an interfacial layer between PMMA and graphene. This allows more effective removal of PMMA. However, Raman spectra of graphene transferred by metal assisted method showed somewhat lower quality than the PMMA assisted method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Day surgery has gained a large popularity during the last decades. In Finland, 57% of the elective procedures, and 50% at Turku University Hospital, were already conducted on day basis during 2012. The steady growth of day surgery is mostly due to an increased safety in perioperative care and cost-effectiveness. The development of surgical techniques and anaesthetic methods has advanced the modern day surgery and extended the repertory of the procedures for use in day surgery operations. Day surgery also offers certain benefits like reduced risk for hospital-related infections, stress and confusion. Patient satisfaction, regarding several issues, is high. Most concerns and complaints are related to postoperative pain, nausea and vomiting pain and nausea. Pain can hamper recovery and pain management is a crucial factor for hospital discharge. Appropriate pain treatment is effective, safe, easy and economical. A procedure-specific approach and an individually planned, multimodal analgesia should be the basis of modern pain management. The main aim of this thesis was to evaluate the effectiveness and safety of anaesthetic technique and methods in pain treatment of orthopaedic day case surgery, and following conclusions were made. Unilateral spinal block was achieved using hyperbaric bupivacaine with a small dose of clonidine but clonidine prolonged the block. Continuous subacromial bupivacaine was found to be safe but conferring only moderate efficacy in pain care after shoulder arthroscopy. Transdermal fentanyl, 12 g/h, as part of multimodal analgesia, offered a safe and easy option to pain management in this patient group. However, after forefoot surgery, it did not reduce pain any further. In general, pain scores in all patient groups were low and the need for rescue opioid moderate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plants were regenerated from leaf-derived callus culture of Stylosanthes scabra, a polyploid legume tolerant to drought and adapted to acid soils. A total of 168 regenerants were planted out in Leonard jars in a complete randomized design. Nitrogen fixation and vegetative growth were indirectly evaluated by shoot dry weight, root dry weight, shoot N content and acetylene reduction activity. The results showed higher variation in the regenerants than in controls not submitted to tissue culture. Significant differences were found for all nitrogen fixation related-traits

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NifA protein activates transcription of nitrogen fixation operons by the alternative sigma54 holoenzyme form of RNA polymerase. This protein binds to a well-defined upstream activator sequence (UAS) located at the -200/-100 position of nif promoters with the consensus motif TGT-N10-ACA. NifA of Azospirillum brasilense was purified in the form of a glutathione-S-transferase (GST)-NifA fusion protein and proteolytic release of GST yielded inactive and partially soluble NifA. However, the purified NifA was able to induce the production of specific anti-A. brasilense NifA-antiserum that recognized NifA from A. brasilense but not from K. pneumoniae. Both GST-NifA and NifA expressed from the E. coli tac promoter are able to activate transcription from the nifHDK promoter but only in an A. brasilense background. In order to investigate the mechanism that regulates NifA binding capacity we have used E. coli total protein extracts expressing A. brasilense nifA in mobility shift assays. DNA fragments carrying the two overlapping, wild-type or mutated UAS motifs present in the nifH promoter region revealed a retarded band of related size. These data show that the binding activity present in the C-terminal domain of A. brasilense NifA protein is still functional even in the presence of oxygen.