893 resultados para Musculoskeletal ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate by ultrasound biomicroscopy (UBM) the anatomical characteristics and the intraocular pressure (IOP) lowering mechanisms of deep sclerectomy after long-term follow-up. Methods: In all, 22 eyes of 21 consecutive patients who had deep sclerectomy were examined by UBM. Several UBM variables were prospectively evaluated, including the presence and maximum length and height of the intrascleral space, the minimum thickness of residual trabeculo-Descemet membrane (TDM), the presence and type of subconjunctival filtering bleb, and the presence of other possible drainage sites, for example suprachoroidal. Surgical success was considered to be achieved when the IOP was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Glaucoma in infants has many causes. Evaluation of the anatomy of the anterior segment of eyes with infantile glaucoma may help to determine the pathogenesis of an infant's disease and influence therapeutic decisions. Methods: Eleven eyes of six infants with glaucoma were evaluated with ultrasound biomicroscopy (UBM) to evaluate the anatomic characteristics and relationships of the anterior segment structures. Results: The anterior chamber angle, iris, lens, ciliary body, and posterior chamber angle could be imaged in detail. Elongated and anteriorly placed ciliary processes were noted in all eight eyes with trabeculodysgenesis. There were no apparent anomalies in the trabecular meshwork, or anterior chamber. In three eyes with dense corneal opacities, ultrasound biomicroscopy showed severe anterior segment disorganization and thin central corneas with posterior corneal excavation. Conclusions: Ultrasound biomicroscopy is a useful non-invasive method for evaluating infants with glaucoma in cases with corneal opacities. This information can help in surgical planning for glaucoma management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the intra- and interobserver agreement in assessing the configuration of the human anterior chamber angle using ultrasound biomicroscopy (UBM). Methods: Two masked clinicians used ubm images to estimate, in 41 eyes, (a) the position of contact between the peripheral iris and the inside of the eye wall, (b) the angular size of the anterior chamber angle (ACA), and (c) the curvature of the peripheral iris. Both observers, masked to the previous results, examined the same images in a second session. Agreement was evaluated using the unweighted ? statistic. Results: Intraobserver agreement in assessing the iris insertion, angular width, and the iris curvature was high (range of ? values, 0.83-0.92). Interobserver agreement in evaluating the level of iris insertion (? = 0.79), the angular width (? = 0.95), and the iris curvature (? = 0.84) was also high. Conclusion: The agreement within the same observer and between observers in evaluating the ACA configuration by UBM was excellent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Berlin high (BEH) and Berlin low (BEL) strains selected for divergent growth differ 3-fold in body weight. We aimed at examining muscle mass, which is a major contributor to body weight, by exploring anatomical characteristics of the soleus muscle, its fiber numbers and their cross sectional area (CSA), by analysing transcriptome of the gastrocnemius and by initiating quantitative trait locus (QTL) mapping. BEH muscles were 4-to-8 times larger compared to BEL strain. In sub-strain BEH+/+, mutant myostatin was replaced with a wild type allele, however, BEH+/+muscles still were 2-to-4 times larger compared to the BEL strain. BEH soleus contained 2-times more (P<0.0001) and 2-times larger in CSA (P<0.0001) fibers compared to BEL strain. In addition, soleus femoral attachment anomaly (SFAA) was observed in all BEL mice. One significant (chromosome 1) and four suggestive (chromosomes 3, 4, 6 and 9) muscle weight QTLs were mapped in 21-day old F2 intercross (n=296) between BEH and BEL strains. The frequency of SFAA incidence in the F2 and in the backcross to BEL strain (BCL) suggested the presence of more than one causative gene. Two suggestive SFAA QTLs were mapped in BCL, however, their peak markers were not associated with the phenotype in F2. RNA-Seq analysis revealed 2,148 differentially expressed (P<0.1) genes and 45,673 SNPs and >2,000 indels between BEH+/+ and BEL males. In conclusion, contrasting muscle traits, genomic and gene expression differences between BEH and BEL strains provide a promising model for the search of genes involved in muscle growth and musculoskeletal morphogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveThe objective of this paper is to elucidate the role of specific cytokines in lupus (SLE) arthritis.MethodsFifty SLE and 40 RA patients had an ultrasound (US) scan of their hand as per standardized protocols. US scores were expressed per joint and as a total 'US activity' score, (sum of power Doppler (PD) and grey-scale synovial hypertrophy scores in all joints) and a total erosion score. SLE disease activity was assessed (BILAG and SELENA-SLEDAI). Plasma levels of IL-6, TNF-alpha and BLyS were measured using sandwich ELISA kits (Quantikine kits, R & D).ResultsOn the basis of the US results SLE patients were divided into three groups: erosive arthritis (n?=?20), non-erosive arthritis (n?=?18) and those with a normal US scan (n?=?12). Across the SLE groups plasma IL-6 levels correlated with CRP (p?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, lead iron tantalate/lead zirconium titanate (PZTFT) was demonstrated to possess large, but unreliable, magnetoelectric coupling at room temperature. Such large coupling would be desirable for device applications but reproducibility would also be critical. To better understand the coupling, the properties of all 3 ferroic order parameters, elastic, electric, and magnetic, believed to be present in the material across a range of temperatures, are investigated. In high temperature elastic data, an anomaly is observed at the orthorhombic mm2 to tetragonal 4mm transition, Tot = 475 K, and a softening trend is observed as the temperature is increased toward 1300 K, where the material is known to become cubic. Thermal degradation makes it impos- sible to measure elastic behavior up to this temperature, however. In the low temperature region, there are elastic anomalies near ≈40 K and in the range 160–245 K. The former is interpreted as being due to a magnetic ordering transition and the latter is interpreted as a hysteretic regime of mixed rhom- bohedral and orthorhombic structures. Electrical and magnetic data collected below room temperature show anomalies at remarkably similar temperature ranges to the elastic data. These observations are used to suggest that the three order parameters in PZTFT are strongly coupled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Chronic musculoskeletal pain is highly prevalent, affecting around one in five people across Europe. Osteoarthritis, low back pain, neck pain and other musculoskeletal disorders are leading causes of disability
worldwide and the most common source of chronic pain. Exercise and/or physical activity interventions have the potential to address not only the pain and disability associated with chronic pain but also the increased risk of morbidity and mortality seen in this population. Although exercise and/or physical activity is widely recommended, there is currently a paucity of research that offers an evidence base upon which the development or optimisation of interventions can be based. This systematic review will investigate the components of interventions associated with changes in physical activity levels in adults with chronic musculoskeletal pain.

Methods/Design: This systematic review will be reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidance. Randomised and quasi-randomised controlled trials of interventions aimed at increasing physical activity in adults with chronic musculoskeletal pain will be included. Articles will be identified through a comprehensive search of the following databases: CENTRAL in the Cochrane Library, the Cochrane Database of Systematic Reviews (CDSR), MEDLINE, Embase, CINAHL, PsycINFO and AMED. Two review authors will independently screen articles retrieved from the search for eligibility, extract relevant data on methodological issues and code interventions according to the behaviour change technique taxonomy (v1) of 93 hierarchically clustered techniques. As complex healthcare interventions can be modified by a wide variety of factors, data will be summarised statistically when the data are available, are sufficiently similar and are of sufficient quality. A narrative synthesis will be completed if there is insufficient data to permit a formal meta-analysis.

Discussion: This review will be of value to clinicians working in chronic pain services and to researchers involved in designing and evaluating interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Melt viscosity is one of the main factors affecting product quality in extrusion processes particularly with regard to recycled polymers. However, due to wide variability in the physical properties of recycled feedstock, it is difficult to maintain the melt viscosity during extrusion of polymer blends and obtain good quality product without generating scrap. This research investigates the application of ultrasound and temperature control in an automatic extruder controller, which has ability to maintain constant melt viscosity from variable recycled polymer feedstock during extrusion processing. An ultrasonic modulation system has been developed and fitted to the extruder prior to the die to convey ultrasonic energy from a high power ultrasonic generator to the polymer melt. Two separate control loops have been developed to run simultaneously in one controller: the first loop controls the ultrasonic energy or temperature to maintain constant die pressure, the second loop is used to control extruder screw speed to maintain constant throughput at the extruder die. Time response and energy consumption of the control methods in real-time experiments are also investigated and reported this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical sensors for ultrasound detection provide high sensitivity and bandwidth, essential for photoacoustic imaging in clinical diagnostics and biomedical research. Implementing plasmonic metamaterials in a non-resonant regime facilitates sub-nanosecond, highly sensitive detectors while eliminating cumbersome optical alignment necessary for resonant sensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To systematically review the evidence examining effects of walking interventions on pain and self-reported function in individuals with chronic musculoskeletal pain.
Data Sources: Six electronic databases (Medline, CINAHL, PsychINFO, PEDro, Sport Discus and the Cochrane Central Register of Controlled Trials) were searched from January 1980 up to March 2014.
Study Selection: Randomized and quasi-randomized controlled trials in adults with chronic low back pain, osteoarthritis or fibromyalgia comparing walking interventions to a non-exercise or non-walking exercise control group.
Data Extraction: Data were independently extracted using a standardized form. Methodological quality was assessed using the United States Preventative Services Task Force (USPSTF) system.
Data Synthesis: Twenty-six studies (2384 participants) were included and suitable data from 17 were pooled for meta-analysis with a random effects model used to calculate between group mean differences and 95% confidence intervals. Data were analyzed according to length of follow-up (short-term: ≤8 weeks post randomization; medium-term: >2 months - 12 months; long-term: > 12 months). Interventions were associated with small to moderate improvements in pain at short (mean difference (MD) -5.31, 95% confidence interval (95% CI) -8.06 to -2.56) and medium-term follow-up (MD -7.92, 95% CI -12.37 to -3.48). Improvements in function were observed at short (MD -6.47, 95% CI -12.00 to -0.95), medium (MD -9.31, 95% CI -14.00 to -4.61) and long-term follow-up (MD -5.22, 95% CI 7.21 to -3.23).
Conclusions: Evidence of fair methodological quality suggests that walking is associated with significant improvements in outcome compared to control interventions but longer-term effectiveness is uncertain. Using the USPSTF system, walking can be recommended as an effective form of exercise or activity for individuals with chronic musculoskeletal pain but should be supplemented with strategies aimed at maintaining participation. Further work is also required examining effects on important health related outcomes in this population in robustly designed studies.