967 resultados para Missing values, Multiple comparisons, Unequal treatment samples
Resumo:
The aim of this study was to evaluate in vivo the use of low-level galium-aluminium-arsenide (GaAlAs) (BDP 600) laser and sodium fluoride varnish (Duraphat((R))) in the treatment of cervical dentine hypersensitivity. Twelve patients, with at least two sensitive teeth were selected. A total of 60 teeth were included in the trial. Prior to desensitizing treatment, dentine hypersensitivity was assessed by a thermal stimulus and patients' response to the examination was considered to be a control. The GaAlAs laser (15 mW, 4 J/cm(2)) was irradiated on contact mode and fluoride varnish was applied at cervical region. The efficiency of the treatments was assessed at three examination periods: immediately after first application, 15 and 30 days after the first application. The degree of sensitivity was determined following predefined criteria. Data were submitted to analysis and no statistically significant difference was observed between fluoride varnish and laser. Considering the treatments separately, there was no significant difference for the fluoride varnish at the three examination periods, and for laser therapy, significant difference (P < 0.05) was found solely between the values obtained before the treatment and 30 days after the first application. It may be concluded that both treatments may be effective in decreasing cervical dentinal hypersensitivity. Moreover, the low-level GaAlAs laser showed improved results for treating teeth with higher degree of sensitivity.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Stainless steel coatings obtained by High Velocity Oxygen Fuel (HVOF) were characterized using optical (OM) and scanning electron microscopy (SEM), electron probe micro-analysis, X-ray diffraction (XRD), open-circuit potential (E-OC) measurements, electrochemical impedance spectroscopy (EIS) and polarisation tests. Differences among coated steels were mainly related with the gun-substrate distance parameter (310 nm for samples A and B and 260 min for C and D). The open-circuit potential values measured for all the samples after 18 h of immersion in aerated and unstirred 3.4% NaCl solution were: - 0.334, - 0.360, - 0.379 and - 0.412 V vs. Ag/AgCl,KClsat. for samples A to D, respectively. For EIS measurements, Nyquist plots showed higher capacitive semi-circle for samples sprayed at longer distance, indicating higher corrosion resistance in NaCl solution. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Soil surface roughness is known to influence water infiltration, runoff and erosion. Soil surface roughness changes with management and weather and its mathematical description still remains an important issue. The main objective of this study was to investigate the effect of tillage on the two fractal indices, fractal dimension, D, and crossover length, 1, currently used in characterizing soil surface microrelief. The statistical index random roughness, RR, was also assessed. Field experiments were done on an Alfisol located at Rio Grande do Sul State (Brazil). Two tillage treatments (conventional versus direct drilling) were tested. The soil surface microrelief was assessed by point elevation measurements in 16 plots for each treatment. The sampling scheme was a square grid with 20 x 20 mm between point spacing and the plot size was 280 x 280 mm, so that each data set consisted of 225 individual elevation points. All indices were calculated after trend removal, both by slope correction, i.e., oriented microrelief, and by slope plus tillage marks correction, i.e., random microrelief. The implemented algorithm for estimating D and 1 consisted in evaluating the roughness around the local root mean square deviation (RMS) of the point elevation values. Irrespective of tillage treatment and detrending procedure, fractal behavior extended only over a bounded range of scales, from 40 to 100 mm, due to the experimental setup. In these conditions, assessing fractal indices was not always straightforward. The statistical index RR and the fractal index I were significantly different between tillage treatments for oriented and random surface conditions. D values of random soil surfaces were not affected by tillage treatment, whereas D values of oriented microrelief were significantly lower in the direct drilled plots. Removal of tillage marks trend resulted in a significant increase in D values. Within each tillage treatment, 1 and D were significantly correlated. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Children who grow up in developing countries of the world must work to help financially support their families, and they must also attend school. We investigated the impact of work on the sleep of working vs. nonworking high school students. Twenty-seven São Paulo, Brazil, public high school students (eight male and eight female working students plus six nonworking female and five nonworking male students) 14-18 yrs of age who attended school Monday-Friday between 19:00 to 22:30h participated. A comprehensive questionnaire about work and living conditions, health status, and diseases and their symptoms was also answered. The activity level and rest pattern (sleep at night and napping during the day) were continuously assessed by wrist actigraphy (Ambulatory Monitoring, USA). The main variables were analyzed by a two-factor ANOVA with application of the Tukey HSD test for multiple comparisons, and the length of sleep during weekdays vs. weekends was compared by Student t-test. Working students went to sleep earlier weekends [F-(1,F-23) = 6.1; p = 0.02] and woke up earlier work days than nonworking students [F-(1,F-23) = 17.3; p = 0.001]. The length of nighttime sleep during weekdays was shorter among all the working [F-(1,F-23) = 16.7; p < 0.001] than all the nonworking students. The sleep duration of boys was shorter than of girls during weekends [F-(1,F-23) = 10.8; P < 0.001]. During weekdays, the duration of napping by working and nonworking male students was shorter than nonworking female students. During weekdays, working girls took the shortest naps [F-(1,F-23) = 5.6; p = 0.03]. The most commonly reported sleep complaint during weekdays was difficulty waking up in the morning [F-(1.23) = 6.5; p = 0.02]. During weekdays, the self-perceived sleep quality of working students was worse than nonworking students [F-(1,F-23) = 6.2; p = 0.02]. The findings of this study show that work has negative effects on the sleep of adolescents, with the possible build-up of a chronic sleep debt with potential consequent impact on quality of life and school learning.
Resumo:
Pectinmethylesterase (PME) was extracted from guava fruit (Psidium guajava L.), cultivar Paluma, by 70% ammonium sulphate saturation and partially purified by gel filtration on Sephadex G100. Gel filtration showed PME isoenzymes with different values of molecular mass. Two samples were examined: concPME (70% saturation by ammonium sulphate) and Iso4 PME (one of the isoforms from gel filtration with the greatest specific activity). Optimum pH of the enzyme (for both samples) was 8.5 and optimum temperature ranged from 75 and 85 degrees C. The optimum sodium chloride concentration was 0.15 M. The K-M and V-max ranged from 0.32 to 0.23 mg m1(-1) and 244 to 53.2 mu mol/min, respectively, for concPME and Iso4PME. The activation energies (E-a) were 64.5 and 103 kJ/mol, respectively, for concPME and Iso4PME. Guava PME, cv Paluma, is a very thermostable enzyme, showing great heat stability at all temperatures studied. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
This article discusses the development of a test bench and a methodology for the study of composite resin abrasive wear. To evaluate the operation of the test bench and to compare the proposed methodology with other existing ones, a study was made of the five composites most commonly used by dentists.The one-way ANOVA method and the Tukey test were used to statistically analyze the results by multiple comparisons of the groups of resins tested. Using the proposed methodology, these resins were classified in an increasing order of abrasive wear strength, as follows: Charisma (the lowest abrasive wear strength), Tetric, TPH, Herculite and Z-100 (the highest abrasive wear strength) (P < 0.05). In comparison to other methodologies, the results of the proposed methodology presented the lowest coefficient of variation. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
INTRODUCTION: Visual analysis is widely used to interpret regional cerebral blood flow (rCBF) SPECT images in clinical practice despite its limitations. Automated methods are employed to investigate between-group rCBF differences in research Studies but have rarely been explored in individual analyses.OBJECTIVES: To compare visual inspection by nuclear physicians with the automated statistical parametric mapping program using a SPECT dataset of patients with neurological disorders and normal control images.METHODS: Using statistical parametric mapping, 14 SPECT images from patients with various neurological disorders were compared individually with a databank of 32 normal images using a statistical threshold of p<0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). Statistical parametric mapping results were compared with Visual analyses by a nuclear physician highly experienced in neurology (A) as well as a nuclear physician with a general background of experience (B) who independently classified images as normal or altered, and determined the location of changes and the severity.RESULTS: of the 32 images of the normal databank, 4 generated maps showing rCBF abnormalities (p<0.05, corrected). Among the 14 images from patients with neurological disorders, 13 showed rCBF alterations. Statistical parametric mapping and physician A completely agreed on 84.37% and 64.28% of cases from the normal databank and neurological disorders, respectively. The agreement between statistical parametric mapping and ratings of physician B were lower (71.18% and 35.71%, respectively).CONCLUSION: Statistical parametric mapping replicated the findings described by the more experienced nuclear physician. This finding suggests that automated methods for individually analyzing rCBF SPECT images may be a valuable resource to complement visual inspection in clinical practice.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We developed 15 new polymorphic microsatellites for the plethodontid salamander Ensatina eschscholtzii. Loci were isolated from a genomic library from Ensatina eschscholtzii xanthoptica enriched for (AAAG)(n) repetitive elements. The number of alleles per locus ranged from 4 to 20 (mean 9) in the sampled population. Observed heterozygosity ranged from 0.37 to 1. None of the loci deviated from Hardy-Weinberg equilibrium or showed significant linkage disequilibrium after a Bonferroni correction for multiple comparisons. All loci amplified in the six other subspecies of the Ensatina eschscholtzii complex. These new markers will prove useful in measuring gene flow and population structure as well as patterns of mating and sperm use in Ensatina.
Resumo:
Transposons are mobile genetic elements found within the genomes of various organisms including bacteria, fungi, plants and animals. Fragments of the transposon Tn1721 were found included in the genome of Xylella fastidiosa strain 9a5c. Regions from such fragments were PCR-amplified using specially designed primers (TNP1 and TNP2). In order to detect insertions of the Tn1721 element, both primers were used and one of them included a region of the transposon (TNP1) and the other one had the right repeat and part of the bacterial chromosome (TNP2). The PCR products obtained from strain 9a5c were used as a pattern for fragment size comparisons when DNA samples from other X. fastidiosa strains were used as template for the PCR assays. Differences were observed concerning the PCR products of such amplifications when some X. fastidiosa strains isolated from grapevine and plum were used. For the citrus-derived strains only the strains U187d and GP920b produced fragments with different sizes or weak band intensity. Such variations in the X. fastidiosa genome related to disrupted Tn1721 copies are probably due to the possibility of such a transposon element being still able to duplicate even after deletion events might have taken place and also because the bacterial strains in which the main differences were detected are derived from different host plants cultivated under different climate conditions from the one used as reference. © 2002 Federation of European Microbiological Societies. Published by Elsevier Science B.V. All rights reserved.
Resumo:
Aim: To assess the DMFT (D = decayed; M = missing; F = filled) index of institutionalized patients with mild and moderate physical and mental disabilities and to correlate it with the Streptococcus mutans (S. mutans) counts in the supragingival bacterial biofilm. Methods: Dental examination of 28 patients aged 15 to 25 years was conducted to determine the DMFT index (number of decayed, missing and filled teeth). Supragingival plaque samples were collected from the buccal surfaces of all teeth. The samples were inoculated in SB20 medium and incubated at 37 °C for 48 hours. Spearman's correlation test was applied (p = 0.05) to evaluate the correlation between the DMFT index and the amount of S. mutans. Results: The mean DMFT recorded was 7.68 and a large mean number of S. mutans colony-forming units (cfu > 10 6) was found. No statistically significant correlation was found between the DMFT index and the number of S. mutans. Conclusions: Under the conditions of this study, no correlation was found between the DMFT index and the number of S. mutans cfu in institutionalized patients with mental retardation and physical disabilities.
Resumo:
Authors - Magno AFF, Martins RP, Vaz LG, Martins LP Objectives - Evaluate the shear bond strength (SBS) and the adhesive remnant index (ARI) of indirect bonded lingual brackets using xenon plasma arc light, light-emitting diode (LED) and conventional quartz-tungsten-halogen light. Material and Methods - Lingual brackets were bonded indirectly to 60 premolars divided to three groups according to the curing light used: Group 1, plasma arc for 6 s; Group 2, LED for 10 s; and Group 3, halogen light for 40 s. After bonding, the specimens were subjected to a shear force until debonding. The debonding pattern was assessed and classified according to the ARI scores. The mean shear bond strengths were accessed by anova followed by the Student-Newman-Keuls test for multiple comparisons. ARI scores were assessed using the chi-square test. Results - The three groups showed significant differences (p < 0.001), with the averages of group 1 < group 2 < group 3. Groups showed no differences regarding ARI scores. Conclusion - Bonding lingual brackets indirectly with plasma arc, during 60% of the time used for the LED, produced lower SBS than obtained with the latter. Using LED during 25% of the time of the halogen light produced lower SBS than obtained with the latter. These differences did not influence the debonding pattern and are clinically acceptable according to the literature. © 2010 John Wiley & Sons A/S.
Resumo:
Objective: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. Methods: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. results: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. Conclusion: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.