984 resultados para Mini-plates


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This clinical report describes an adult patient referred for orthodontic treatment with mini-implants as anchorage to correct the root angulation of maxillary lateral incisors. The purpose of this report was to demonstrate the versatility of mini-implants placed in a vertical direction in esthetic areas. During orthodontic treatment, some aspects must be observed to preserve the interim restoration against the occlusal loads to avoid screw fracture. A fixed appliance was placed to correct the position of the maxillary anterior teeth and to complete the treatment. Acceptable esthetics and function were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo teve como objetivo analisar o efeito de um período de treinamento com uma aula coreografada na resistência de força de membros inferiores e na aptidão aeróbia em mulheres. Participaram do estudo, 11 mulheres ativas (Idade = 31,8  8,04 anos, Massa corporal = 60,5  6,49 kg e Estatura = 160,7  4,35cm). Foram realizados antes e após o período de treinamento os seguintes procedimentos: 1) Teste progressivo de Bruce, para a estimativa do consumo máximo de oxigênio (VO2max); 2) Teste de repetições máximas, para estimar a resistência de força (RF) e; 3) Aula coreografada. O treinamento foi realizado em um período de 6 semanas, com frequência semanal de 2 sessões. Houve um aumento significante na RF (de 30,4 3,98 para 37,2 6,25) e no VO2max (de 28,2 6,25 para 34,3 6,24 ml/kg/min) após o período de treinamento. Portanto, um período de treinamento composto por aulas coreografadas envolvendo saltos e um alto número de repetições proporciona uma melhora na resistência de força de membros inferiores e na aptidão aeróbia e mulheres ativas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The educational institutions need to rethink issues related to teacher training in order to seek personal construction of teaching. Oriented research has been identified as useful in the process of teacher training. Through research builds knowledge about the problems faced in teaching, producing the most effective methods. The aim of this paper is to verify the validity of the application of research activities in the form of short courses and themed play during the formation of licensees and the use and construction of knowledge of high school students who attended these short courses. This work is linked to training of undergraduates and implementation of different activities of teaching and learning for high school students. The oriented investigation was the methodology chosen for the development of activities in which, through the construction and implementation of the mini-courses Students are encouraged to participate in the construction of knowledge itself in activities that suggest the development and testing of hypotheses. The mini-courses are designed and implemented by teachers of the ninth and tenth terms of the degree in chemistry. Students of public schools were the privileged. Data were collected through observation and interview. In applying these mini-courses, associated with the daily, prospective teachers connected theory to practice, arousing the curiosity of students and leading them to raise issues related to the content of chemistry. Students showed interest in the construction of the content addressed. The student teachers sought to study different concepts and how to make them more attractive, causing the chemistry was associated with the phenomena of everyday life, including the problems faced when teaching and trying different possible solutions. Thus, there was an increase in interest in teaching and learning

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Triatominae subfamily consists of 145 species distributed in 18 genera and grouped in six tribes. Currently, there are 86 karyotypes described in the literature, distributed in 11 genera. There are five chromosomal complements described for these bloodsucking insects, out more, 22 (20A+XY), 23 (20A+X1X2Y), 24 (20A+X1X2X3Y), 21 (18A+X1X2Y), 25 (22A+X1X2Y). Thus, we review all triatomine species with the number of chromosomes described in the literature. Through these data highlight the importance of further analysis cytogenetic with karyotype description in Triatominae subfamily, since it can help as an important tool cytotaxonomy and mainly allows the understanding of the evolution of this important group of insect vectors of Chagas disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The retromolar triangle is a triangular area located in the mandible, posteriorly to the last molar. This region, due its thickness and bone density, is widely used for the installation of devices that provide an anchorage system for the movement of the lower molars. The aim of this research is to provide morphometric data of the mucosa thickness of the retromolar triangle. Twenty-five patients of portuguese nationality, with indication for extraction of the impacted lower third molar (right and/or left), were studied. In the region of the retromolar triangle were demarcated 3 points corresponding to the vertices of a triangle whose the base was torned for the distal face of the lower third molar and the lenght of the sides corresponded to vestibulolingual dimension of the same tooth, then was demarcated a fourth point corresponding to the geometric center of the triangle. Then, using a finger spreader with silicone stop were measured the mucosal tickness at each point. The data obtained were tabulated and analyzed. The lowest average value found was 5.5mm on the right side and the highest average value found was 7.13mm on the left side. Considering the mean values obtained at the points of the retromolar triangle mucosa measured in this study, we conclude that the retromolar triangle shows thick mucosa, so the mini-implants indicated for this region should have a long transmucosal neck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Horticultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Production of mini vegetables in organic system is a good alternative to improve profit, but there are no researches about the optimum plant density for these cultivars in Brazilian conditions. Two experiments were conducted to evaluate the production of mini lettuce cultivars in different plant densities. Experiment 1 was conducted from January 1th (sowing) to February 10th (harvesting), 2012. The experimental design was completely randomized blocks, with six treatments in factorial scheme, 3 mini lettuce cultivars (Tudela, Renoir and Sartre) x 2 spacing between plants (16 and 20 cm), with eight replications and plots (2.04 m(2)) with six rows, spaced 15 cm. Experiment 2 was conducted from June 6th (sowing) to July 18th (harvesting), 2012. The cultivars Sartre and Renoir were evaluated under four plant densities (444,444; 333,333; 266,667 and 200,000 plants ha(-1), corresponding to spacing of 15x15, 15x20, 25x15 and 25x20 cm, respectively). Eight treatments were defined by a factorial scheme 2 (cultivars) x 4 (plant densities) and arranged in a completely randomized block design, with nine replications and plots with 2.04 m2. The evaluated characteristics in both experiments were total and marketable fresh weight per plant, plant dry weight, plant diameter and height, marketable yield and discard percentage. In first experiment, during the summer, cultivar Sartre showed the highest marketable fresh weight (72 g plant(-1)). Heaviest plants (91.6 g plant(-1)) were obtained with the higher plant spacing, but the highest yield (2.51 kg m(-2)) was obtained with the smaller spacing. In winter, plants with higher total (190 g plant(-1)) and marketable (146 g planta(-1)) fresh weight were obtained with cultivar Sartre, and the same was observed in low plant density. However, the higher plant density, the higher the yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.