852 resultados para Micro ring cavities


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the determining factors of cience-based cooperation in the case of small and micro firms. In this research, we propose an analytical framework based on the resource-based view of the firm and we identify a set of organisational characteristics, which we classify as internal, external and structural factors. Each factor can be linked to at least one reason, from the firm¿s point of view, to cooperate with universities and public research centres. Each reason can, in turn, be used as an indicator of a firm¿s organisational needs or organisational capacities. In order to validate the theoretical model, we estimate a logistic regression that models the propensity to participate in science-based cooperation activities within a sample of 285 small and micro firms located in Barcelona. The results show the key role played by the absorptive capacity of new and small companies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2004, a 56-year-old woman was diagnosed with Stage IA follicular lymphoma in a cervical lymph node biopsy. The patient experienced total remission after local radiation therapy. In 2009, a control computed tomography scan evidenced a pelvic mass, prompting total hysterectomy. The latter harbored a 4.8-cm intramural uterine tumor corresponding to a mostly diffuse and focally nodular proliferation of medium to large cells, with extensive, periodic acid-Schiff negative, signet ring cell changes, and a pan-keratin negative, CD20+, CD10+, Bcl2+, Bcl6+ immunophenotype. Molecular genetic studies showed the same clonal IGH gene rearrangement in the lymph node and the uterus, establishing the uterine tumor as a relapse of the preceding follicular lymphoma, although no signet ring cells were evidenced at presentation. Uterine localization of lymphomas is rare, and lymphomas with signet ring cell features are uncommon. This exceptional case exemplifies a diagnostically challenging situation and expands the differential diagnosis of uterine neoplasms displaying signet ring cell morphology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: « Osteo-Mobile Vaud » is a mobile osteoporosis (OP) screening program. The women > 60 years living in the region Vaud will be offered OP screening with new equipment installed in a bus. The main goal is to evaluate the fracture risk with the combination of clinical risk factors (CRF) and informations extracted by a single DXA: bone mineral density (BMD), vertebral fracture assessment (VFA), and micro-architecture (MA) evaluation. MA is yet evaluable in daily practice by the Trabecular Bone Score (TBS) measure. TBS is a novel grey-level texture measurement reflecting bone MA based on the use of experimental variograms of 2D projection images. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis value, partially independent of CRF and BMD. A 55-years follow- up is planned. Method: The Osteo-Mobile Vaud cohort (1500 women, > 60 years, living in the region Vaud) started in July 2010. CRF for OP, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded. Preliminary results are reported. Results: In July 31th, we evaluated 510 women: mean age 67 years, BMI 26 kg/m². 72 women had one or more fragility fractures, 39 had vertebral fracture (VFx) grade 2/3. TBS decreases with age (-0.005 / year, p<0.001), and with BMI (-0.011 per kg/m², p<0.001). Correlation between BMD and site matched TBS is low (r=0.4, p<0.001). For the lowest T-score BMD, odds ratio (OR, 95% CI) for VFx grade 2/3 and clinical OP Fx are 1.8 (1.1-2.9) and 2.3 (1.5-3.4). For TBS, age-, BMI- and BMD adjusted ORs (per SD decrease) for VFx grade 2/3 and clinical OP Fx are 1.9 (1.2-3.0) and 1.8 (1.2-2.7). The TBS added value was independent of lumbar spine BMD or the lowest T-score (femoral neck, total hip or lumbar spine). Conclusion: As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS and BMD may increase significantly the identification of women with prevalent OP Fx. For the first time we are able to have complementary information about fracture (VFA), density (BMD), and micro-architecture (TBS) from a simple, low ionizing radiation and cheap device: DXA. The value of such informations in a screening program will be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to assess the effect of iStent (trabecular micro-bypass stent) implantation in combination with phacoemulsification on IOP and glaucoma medications and to compare this to the outcome of phacoemulsification alone. Patients and Methods: A retrospective consecutive comparative review was undertaken. 131 eyes with ocular hypertension and medically controlled glaucoma underwent phacoemulsification alone (n = 78 group I) or combined with gonioscopic-guided implantation of one iStent (n = 31, group II) or two iStents (n = 22, group III). Patients were assessed at postoperative weeks 1, 3 and 6, and months 3 and 6. Pre- and post-operative measures included visual acuity, IOP and glaucoma medications. Results: Post-operatively at 6 months, mean IOP decreased from 16.3 mmHg to 14.2 mmHg in group I (p < 0.01), from 16.7 mmHg to 15.1 mmHg in group II (p < 0.16) and from 17.0 to 13.8 in group III (p = 0.05). Mean glaucoma medication decreased from 1.9 to 1.6 in group I (8 %, p = 0.12), from 2.5 to 0.8 in group II (27 %, p = 0.04), and from 2.1 to 1.0 in group III (45 %, p < 0.01). Conclusions: iStent implantation resulted in similar IOP reduction to phacoemulsification alone but achieved a significantly greater reduction in glaucoma medications. This may improve compliance and quality of life, and reduce health care costs in patients with early to moderate glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Infected postpneumonectomy chest cavities may be related to chronic postpneumonectomy empyema or arise in rare situations of necrotizing pneumonia with complete lung destruction where pneumonectomy and pleural debridement are required. We evaluated the safety and efficacy of an intrathoracic vacuum-assisted closure device (VAC) for the treatment of infected postpneumonectomy chest cavities. METHOD: A retrospective single institution review of all patients with infected postpneumonectomy chest cavities treated by VAC between 2005 and 2013. Patients underwent surgical debridement of the thoracic cavity, muscle flap closure of the bronchial stump when a fistula was present, and repeated intrathoracic VAC dressings until granulation tissue covered the entire chest cavity. After this, the cavity was obliterated by a Clagett procedure and closed. RESULTS: Twenty-one patients (14 men and 7 women) underwent VAC treatment of their infected postpneumonectomy chest cavity. Twelve patients presented with a chronic postpneumonectomy empyema (10 of them with a bronchopleural fistula) and 9 patients with an empyema occurring in the context of necrotizing pneumonia treated by pneumonectomy. In-hospital mortality was 23%. The median duration of VAC therapy was 23 days (range, 4-61 days) and the median number of VAC changes per patient was 6 (range, 2-14 days). Infection control and successful chest cavity closure was achieved in all surviving patients. One adverse VAC treatment-related event was identified (5%). CONCLUSIONS: The intrathoracic VAC application is a safe and efficient treatment of infected postpneumonectomy chest cavities and allows the preservation of chest wall integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Past temperature variations are usually inferred from proxy data or estimated using general circulation models. Comparisons between climate estimations derived from proxy records and from model simulations help to better understand mechanisms driving climate variations, and also offer the possibility to identify deficiencies in both approaches. This paper presents regional temperature reconstructions based on tree-ring maximum density series in the Pyrenees, and compares them with the output of global simulations for this region and with regional climate model simulations conducted for the target region. An ensemble of 24 reconstructions of May-to-September regional mean temperature was derived from 22 maximum density tree-ring site chronologies distributed over the larger Pyrenees area. Four different tree-ring series standardization procedures were applied, combining two detrending methods: 300-yr spline and the regional curve standardization (RCS). Additionally, different methodological variants for the regional chronology were generated by using three different aggregation methods. Calibration verification trials were performed in split periods and using two methods: regression and a simple variance matching. The resulting set of temperature reconstructions was compared with climate simulations performed with global (ECHO-G) and regional (MM5) climate models. The 24 variants of May-to-September temperature reconstructions reveal a generally coherent pattern of inter-annual to multi-centennial temperature variations in the Pyrenees region for the last 750 yr. However, some reconstructions display a marked positive trend for the entire length of the reconstruction, pointing out that the application of the RCS method to a suboptimal set of samples may lead to unreliable results. Climate model simulations agree with the tree-ring based reconstructions at multi-decadal time scales, suggesting solar variability and volcanism as the main factors controlling preindustrial mean temperature variations in the Pyrenees. Nevertheless, the comparison also highlights differences with the reconstructions, mainly in the amplitude of past temperature variations and in the 20th century trends. Neither proxy-based reconstructions nor model simulations are able to perfectly track the temperature variations of the instrumental record, suggesting that both approximations still need further improvements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the thesis was to study fundamental structural and optical properties of InAs islands and In(Ga)As quantum rings. The research was carried out at the Department of Micro and Nanosciences of Helsinki University of Technology. A good surface quality can be essential for the potential applications in optoelectronic devices. For such device applications it is usually necessary to control size, density and arrangement of the islands. In order to study the dependence of the structural properties of the islands and the quantum rings on growth conditions, atomic force microscope was used. Obtained results reveal that the size and the density of the In(Ga)As quantum rings strongly depend on the growth temperature, the annealing time and the thickness of the partial capping layer. From obtained results it is possible to conclude that to get round shape islands and high density one has to use growth temperature of 500 ̊C. In the case of formation of In(Ga)As quantum rings the effect of mobility anisotropy is observed that so the shape of the rings is not symmetric. To exclude this effect it is preferable to use a higher annealing temperature of 570 ̊C. Optical properties were characterized by PL spectroscopy. PL emission was observed from buried InAs quantum dots and In(Ga)As quantum rings grown with different annealing time and temperature and covered with a various thickness of the partial capping layer.