765 resultados para MEASURING DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pavement profile or smoothness has been identified nationally as a good measure of highway user satisfaction. This has led highway engineers to measure profiles of both operating and new highways. Operational highway profiles are often measured with high-speed inertial profilers. New highway profiles are usually measured with profilographs in order to establish incentives or disincentives for pavement construction. In most cases, these two processes do not measure the same value from the “cradle to grave” life of pavements. In an attempt to correct the inconsistency between measuring techniques, lightweight profilers intended to produce values to be used for construction acceptance are being made that measure the same profile as high-speed inertial profilers. Currently, two profiler systems have been identified that can measure pavement profile during construction. This research has produced a field evaluation of the two systems. The profilers evaluated in this study are able to detect roughness in the final profile, including localized roughness and roughness at joints. Dowel basket ripple is a significant source of pavement surface roughness. The profilers evaluated in this study are able to detect dowel basket ripple with enough clarity to warn the paving crew. String-line disturbances degrade smoothness. The profilers evaluated in this study are able to detect some string-line disturbances during paving operations. The profilers evaluated in this study are not currently able to produce the same absolute International Roughness Index (IRI) values on the plastic concrete that can be measured by inertial profilers on the hardened concrete. Construction application guidelines are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was conducted in France to evaluate the impact of health information on consumers’ choice between two different types of fish. Successive messages revealing risks (methylmercury) and benefits (omega-3s) of consuming the fish, along with consumption recommendations, were delivered. Results show a significant difference of reaction according to the order and type of information. The information about risks had a larger marginal impact on change in willingness to pay (WTP) than did the information about benefits. While the results show that detailed messages on risks/benefits, including recommendations for nutrition behavior, matter in the modification of WTP, 40% of respondents did not change their initial choices after the revelation of health information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is commonly regarded that the overuse of traffic control devices desensitizes drivers and leads to disrespect, especially for low-volume secondary roads with limited enforcement. The maintenance of traffic signs is also a tort liability concern, exacerbated by unnecessary signs. The Federal Highway Administration’s (FHWA) Manual on Uniform Traffic Control Devices (MUTCD) and the Institute of Transportation Engineer’s (ITE) Traffic Control Devices Handbook provide guidance for the implementation of STOP signs based on expected compliance with right-of-way rules, provision of through traffic flow, context (proximity to other controlled intersections), speed, sight distance, and crash history. The approach(es) to stop is left to engineering judgment and is usually dependent on traffic volume or functional class/continuity of system. Although presently being considered by the National Committee on Traffic Control Devices, traffic volume itself is not given as a criterion for implementation in the MUTCD. STOP signs have been installed at many locations for various reasons which no longer (or perhaps never) met engineering needs. If in fact the presence of STOP signs does not increase safety, removal should be considered. To date, however, no guidance exists for the removal of STOP signs at two-way stop-controlled intersections. The scope of this research is ultra-low-volume (< 150 daily entering vehicles) unpaved intersections in rural agricultural areas of Iowa, where each of the 99 counties may have as many as 300 or more STOP sign pairs. Overall safety performance is examined as a function of a county excessive use factor, developed specifically for this study and based on various volume ranges and terrain as a proxy for sight distance. Four conclusions are supported: (1) there is no statistical difference in the safety performance of ultra-low-volume stop-controlled and uncontrolled intersections for all drivers or for younger and older drivers (although interestingly, older drivers are underrepresented at both types of intersections); (2) compliance with stop control (as indicated by crash performance) does not appear to be affected by the use or excessive use of STOP signs, even when adjusted for volume and a sight distance proxy; (3) crash performance does not appear to be improved by the liberal use of stop control; (4) safety performance of uncontrolled intersections appears to decline relative to stop-controlled intersections above about 150 daily entering vehicles. Subject to adequate sight distance, traffic professionals may wish to consider removal of control below this threshold. The report concludes with a section on methods and legal considerations for safe removal of stop control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Closures of atrial septal defects or a patent foramen ovale (PFO) are increasingly performed percutaneously. The experience of late migration of a new bio-absorbable device is presented here, followed by conceptual discussion. METHODS: Six months post PFO closure with a BioSTAR® device a patient presented with chest pain. Echocardiography showed a hyperechogenic structure perforating the aortic wall. RESULTS: Surgical exploration showed a perforation of the ascending aorta by one metallic, non absorbable arm. This is the second case of late (>6 months) dislocation of the residual framework of the occluder. CONCLUSIONS: The overall incidence of perforation of cardiac structures due to secondary dislocation is low. However this complication exists and should kept in mind in symptomatic patients with new onset of chest pain, after percutaneous procedures. The concept of biodegradation, with residual, non absorbable metal braiding, should be reviewed, analyzing in particular long term results and incidence of secondary dislocation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R (2) = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over recent years, both governments and international aid organizations have been devoting large amounts of resources to "simplifying" the procedures for setting up and formalizing firms. Many of these actions have focused on reducing the initial costs of setting up the firm, disregarding the more important role of business registers as a source of reliable information for judges, government departments and, above all, other firms. This reliable information is essential for reducing transaction costs in future dealings with all sorts of economic agents, both public and private. The priorities of reform policies should therefore be thoroughly reviewed, stressing the value of the legal institutions rather than trivializing them as is often the case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This was a systematic review aimed at identifying and characterizing measuring instruments, developed in the context of cardiology, which were adapted into Portuguese language of Brazil. Systematic searches were performed in six databases. Information extracted included cultural adaptation process and measurement properties. To assess the methodological quality of studies, criteria based on international guidelines for cultural adaptation of instruments were used. Among the 114 articles found, 14 were eligible for review. Of these, most evaluated quality of life (35.7%) and health knowledge/learning (28.6%). Most studies followed all stages of the adaptation process recommended in the literature. With respect to measurement properties, internal consistency, verified by Cronbach’s alpha, was the property reported in the majority of the studies, as well as construct and criterion validity. This study is expected to provide to the scientific community a critical evaluation of adapted questionnaires available in the context of cardiology.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Comparar a gravidade das lesões e do trauma mensurada pelas versões da Abbreviated Injury Scale 1998 e 2005 e verificar a mortalidade nos escores Injury Severity Score e New Injury Severity Score nas duas versões.Método: Estudo transversal e retrospectivo analisou lesões de pacientes de trauma, de três hospitais universitários do município de São Paulo, Brasil. Cada lesão foi codificada com Abbreviated Injury Scale 1998 e 2005. Os testes estatísticos aplicados foram Wilcoxon, McNemar-Bowker, Kappa e teste Z.Resultados: A comparação das duas versões resultou em discordância significante de escores em algumas regiões corpóreas. Com a versão 2005 os níveis de gravidade da lesão e do trauma foram significantemente reduzidos e a mortalidade foi mais elevada em escores mais baixos. Conclusão: Houve redução da gravidade da lesão e do trauma e alteração no percentual de mortalidade com o uso da Abbreviated Injury Scale 2005.





Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doxorubicin is an antineoplasic agent active against sarcoma pulmonary metastasis, but its clinical use is hampered by its myelotoxicity and its cumulative cardiotoxicity, when administered systemically. This limitation may be circumvented using the isolated lung perfusion (ILP) approach, wherein a therapeutic agent is infused locoregionally after vascular isolation of the lung. The influence of the mode of infusion (anterograde (AG): through the pulmonary artery (PA); retrograde (RG): through the pulmonary vein (PV)) on doxorubicin pharmacokinetics and lung distribution was unknown. Therefore, a simple, rapid and sensitive high-performance liquid chromatography method has been developed to quantify doxorubicin in four different biological matrices (infusion effluent, serum, tissues with low or high levels of doxorubicin). The related compound daunorubicin was used as internal standard (I.S.). Following a single-step protein precipitation of 500 microl samples with 250 microl acetone and 50 microl zinc sulfate 70% aqueous solution, the obtained supernatant was evaporated to dryness at 60 degrees C for exactly 45 min under a stream of nitrogen and the solid residue was solubilized in 200 microl of purified water. A 100 microl-volume was subjected to HPLC analysis onto a Nucleosil 100-5 microm C18 AB column equipped with a guard column (Nucleosil 100-5 microm C(6)H(5) (phenyl) end-capped) using a gradient elution of acetonitrile and 1-heptanesulfonic acid 0.2% pH 4: 15/85 at 0 min-->50/50 at 20 min-->100/0 at 22 min-->15/85 at 24 min-->15/85 at 26 min, delivered at 1 ml/min. The analytes were detected by fluorescence detection with excitation and emission wavelength set at 480 and 550 nm, respectively. The calibration curves were linear over the range of 2-1000 ng/ml for effluent and plasma matrices, and 0.1 microg/g-750 microg/g for tissues matrices. The method is precise with inter-day and intra-day relative standard deviation within 0.5 and 6.7% and accurate with inter-day and intra-day deviations between -5.4 and +7.7%. The in vitro stability in all matrices and in processed samples has been studied at -80 degrees C for 1 month, and at 4 degrees C for 48 h, respectively. During initial studies, heparin used as anticoagulant was found to profoundly influence the measurements of doxorubicin in effluents collected from animals under ILP. Moreover, the strong matrix effect observed with tissues samples indicate that it is mandatory to prepare doxorubicin calibration standard samples in biological matrices which would reflect at best the composition of samples to be analyzed. This method was successfully applied in animal studies for the analysis of effluent, serum and tissue samples collected from pigs and rats undergoing ILP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractOBJECTIVETo analyze the care implemented by the nursing team to promote the safety of adult patients and prevention of skin and mucosal lesions associated with the presence of lower airways invasive devices.METHODStudy with qualitative and quantitative approach, descriptive and exploratory type, whose investigative scenarios were adult inpatient units of a hospital in the West Frontier of Rio Grande do Sul. The study subjects consisted of nurses, nursing technicians and nursing assistants.RESULTSA total of 118 professionals were interviewed. We highlight the observed specific care with endotracheal tube and tracheostomy, management and assessment of the cuff and the criteria used to secretion aspiration.CONCLUSIONThere is a superficial nursing work in the patient direct care and a differentiation in relation to the perception of nurse technicians, especially those working in the intensive care unit, who presented major property and view of the patient's clinical status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Objective To explore potential associations between nursing workload and professional satisfaction among nursing personnel (NP) in Greek Coronary Care Units (CCUs). Method A cross-sectional study was performed involving 66 members of the NP employed in 6 randomly selected Greek CCUs. Job satisfaction was assessed by the IWS and nursing workload by NAS, CNIS and TISS-28. Results The response rate was 77.6%. The reliability of the IWS was α=0.78 and the mean score 10.7 (±2.1, scale range: 0.5-39.7). The most highly valued component of satisfaction was “Pay”, followed by “Task requirements”, “Interaction”, “Professional status”, “Organizational policies” and “Autonomy”. NAS, CNIS and TISS-28 were negatively correlated (p≤0.04) with the following work components: “Autonomy”, “Professional status”, “Interaction” and “Task requirements”. Night shift work independently predicted the score of IWS. Conclusion The findings show low levels of job satisfaction, which are related with nursing workload and influenced by rotating shifts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine psychometric properties of the Functional Assessment of Chronic Illness Therapy-Spiritual well-being (FACIT-Sp) in a cohort of older patients admitted to rehabilitation. Method: Patients aged 65+, with MMSE score>19, admitted consecutively over 6 months in post-acute rehabilitation were enrolled (N=144, 81.27.2 years, 68.8% women). Data on medical, functional, and mental status were systematically collected upon admission. Spiritual well-being was assessed within 3 days after admission using the FACIT-Sp (12 items, score from 0 to 48, high spiritual well-being defined as a score ≥36) and the single question "Are you at peace?" (score from 0 to 10 on a visual analog scale). Results: FACIT-Sp scores ranged from 7 to 44(mean=29.87.7). Overall, 24.3% of the patients had high spiritual well-being. Internal consistency was optimal for total score (Cronbach's alpha =0.85). Itemto- total correlations were all significant, ranging from 0.28 to 0.73. A confirmatory factorial analysis yielded a 2-factor solution, consistent with Meaning and Faith proposed subscales and accounting for 52% of the variance . FACIT-Sp total score correlated positively with the question «Are you at peace ?» (Spearman's rho 0.49, P<.001) and negatively with depressive symptoms (Spearman's rho -0.37, P<.001), confirming FACIT-Sp validity. Compared to the others, patients with higher spiritual well-being had significantly better function at admission (Barthel's score 74.817.1 vs 68.514.1, P=.014). Conclusions: The FACIT-Sp remains a reliable and valid measure to assess spiritual well-being in older patients undergoing rehabilitation. The relatively low proportion of patients with high spiritual well-being deserves further investigation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes empirically the volatility of consumption-based stochastic discount factors as a measure of implicit economic fears by studying its relationship with future economic and stock market cycles. Time-varying economic fears seem to be well captured by the volatility of stochastic discount factors. In particular, the volatility of recursive utility-based stochastic discount factor with contemporaneous growth explains between 9 and 34 percent of future changes in industrial production at short and long horizons respectively. They also explain ex-ante uncertainty and risk aversion. However, future stock market cycles are better explained by a similar stochastic discount factor with long-run consumption growth. This specification of the stochastic discount factor presents higher volatility and lower pricing errors than the specification with contemporaneous consumption growth.