913 resultados para MAGNETIC-RESONANCE
Resumo:
Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. Its practical determination by echocardiography remains challenging. We compared routine assessment of lateral tricuspid annular systolic motion velocity (TV(lat), cm/s) using pulsed-wave tissue Doppler imaging from the apical 4-chamber view with cardiac magnetic resonance (CMR) as reference method.
Resumo:
The aim of this study was to demonstrate the anatomy of the quadrigeminal cistern, define the anatomic landmarks, and measure the extension of the cistern in the living by using magnetic resonance (MR) cisternography with 3-dimensional reconstruction.
Resumo:
Objective Impaired function of the central gamma-aminobutyric acid (GABA) system, which provides the brain’s major inhibitory pathways, is thought to play an important role in the pathophysiology of anxiety disorders. The effect of acute psychological stress on the human GABA-ergic system is still unknown, however. The purpose of this study was to determine the effect of acute stress on prefrontal GABA levels. Method A recently developed noninvasive magnetic resonance spectroscopy method was used to measure changes in the GABA concentration of the prefrontal cortex in 10 healthy human subjects during a threat-of-shock condition and during a safe condition (two sessions on different days). The main outcome measure was the mean GABA concentration within a 3×3×2-cm3 voxel selected from the medial prefrontal cortex. Results Prefrontal GABA decreased by approximately 18% in the threat-of-shock condition relative to the safe condition. This reduction was specific to GABA, since the concentrations of N-acetyl-aspartate, choline-containing compounds, and glutamate/glutamine levels obtained in the same spectra did not change significantly. Conclusions This result appeared compatible with evidence from preclinical studies in rodents, which showed rapid presynaptic down-regulation of GABA-ergic neurotransmission in response to acute psychological stress. The molecular mechanism and functional significance of this reduced inhibitory effect of acute psychological stress in relation to impaired GABA-ergic function in anxiety disorders merit further investigation.
Resumo:
In the present multi-modal study we aimed to investigate the role of visual exploration in relation to the neuronal activity and performance during visuospatial processing. To this end, event related functional magnetic resonance imaging er-fMRI was combined with simultaneous eye tracking recording and transcranial magnetic stimulation (TMS). Two groups of twenty healthy subjects each performed an angle discrimination task with different levels of difficulty during er-fMRI. The number of fixations as a measure of visual exploration effort was chosen to predict blood oxygen level-dependent (BOLD) signal changes using the general linear model (GLM). Without TMS, a positive linear relationship between the visual exploration effort and the BOLD signal was found in a bilateral fronto-parietal cortical network, indicating that these regions reflect the increased number of fixations and the higher brain activity due to higher task demands. Furthermore, the relationship found between the number of fixations and the performance demonstrates the relevance of visual exploration for visuospatial task solving. In the TMS group, offline theta bursts TMS (TBS) was applied over the right posterior parietal cortex (PPC) before the fMRI experiment started. Compared to controls, TBS led to a reduced correlation between visual exploration and BOLD signal change in regions of the fronto-parietal network of the right hemisphere, indicating a disruption of the network. In contrast, an increased correlation was found in regions of the left hemisphere, suggesting an intent to compensate functionality of the disturbed areas. TBS led to fewer fixations and faster response time while keeping accuracy at the same level, indicating that subjects explored more than actually needed.
Resumo:
Computed tomography (CT) and magnetic resonance (MR) imaging have become important elements of forensic radiology. Whereas the feasibility and potential of CT angiography have long been explored, postmortem MR angiography (PMMRA) has so far been neglected. We tested the feasibility of PMMRA on four adult human cadavers. Technical quality of PMMRA was assessed relative to postmortem CT angiography (PMCTA), separately for each body region. Intra-aortic contrast volumes were calculated on PMCTA and PMMRA with segmentation software. The results showed that technical quality of PMMRA images was equal to PMCTA in 4/4 cases for the head, the heart, and the chest, and in 3/4 cases for the abdomen, and the pelvis. There was a mean decrease in intra-aortic contrast volume from PMCTA to PMMRA of 46%. PMMRA is technically feasible and allows combining the soft tissue detail provided by MR and the information afforded by angiography.
Resumo:
Comparison of arterial and venous coronary artery bypass flow measurements using 3-T magnetic resonance (MR) phase contrast in correlation with intraoperative Doppler flow measurements.
Resumo:
Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.
Resumo:
Current conventional cross-sectional imaging techniques, such as contrast-enhanced computed tomography and magnetic resonance imaging (MRI), are largely inaccurate in detecting local recurrence after radical prostatectomy. We report on five patients with biochemical recurrence after radical retropubic prostatectomy and pelvic lymph node dissection for whom local recurrence could only be detected with diffusion-weighted (DW) MRI. Prior to DW-MRI, all patients had negative digital rectal examinations, negative or equivocal conventional cross-sectional imaging, and negative bone scans. All suspicious lesions on DW-MRI imaging were histologically proved to be local recurrences of prostate cancer after either transrectal ultrasound-guided or transurethral biopsy. These results should encourage other centres to test our findings.
Resumo:
Objective Femoroacetabular impingement may be a risk factor for hip osteoarthritis in men. An underlying hip deformity of the cam type is common in asymptomatic men with nondysplastic hips. This study was undertaken to examine whether hip deformities of the cam type are associated with signs of hip abnormality, including labral lesions and articular cartilage damage, detectable on magnetic resonance imaging (MRI). Methods In this cross-sectional, population-based study in asymptomatic young men, 1,080 subjects underwent clinical examination and completed a self-report questionnaire. Of these subjects, 244 asymptomatic men with a mean age of 19.9 years underwent MRI. All MRIs were read for cam-type deformities, labral lesions, cartilage thickness, and impingement pits. The relationship between cam-type deformities and signs of joint damage were examined using logistic regression models adjusted for age and body mass index. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were determined. Results Sixty-seven definite cam-type deformities were detected. These deformities were associated with labral lesions (adjusted OR 2.77 [95% CI 1.31, 5.87]), impingement pits (adjusted OR 2.9 [95% CI 1.43, 5.93]), and labral deformities (adjusted OR 2.45 [95% CI 1.06, 5.66]). The adjusted mean difference in combined anterosuperior femoral and acetabular cartilage thickness was −0.19 mm (95% CI −0.41, 0.02) lower in those with cam-type deformities compared to those without. Conclusion Our findings indicate that the presence of a cam-type deformity is associated with MRI-detected hip damage in asymptomatic young men.
Resumo:
With the increasing advances in hip joint preservation surgery, accurate diagnosis and assessment of femoral head and acetabular cartilage status is becoming increasingly important. Magnetic resonance imaging (MRI) of the hip does present technical difficulties. The fairly thin cartilage lining necessitates high image resolution and high contrast-to-noise ratio (CNR). With MR arthrography (MRA) using intraarticular injected gadolinium, labral tears and cartilage clefts may be better identified through the contrast medium filling into the clefts. However, the ability of MRA to detect varying grades of cartilage damage is fairly limited and early histological and biochemical changes in the beginning of osteoarthritis (OA) cannot be accurately delineated. Traditional MRI thus lacks the ability to analyze the biological status of cartilage degeneration. The technique of delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) is sensitive to the charge density of cartilage contributed by glycosaminoglycans (GAGs), which are lost early in the process of OA. Therefore, the dGEMRIC technique has a potential to detect early cartilage damage that is obviously critical for decision-making regarding time and extent of intervention for joint-preservation. In the last decade, cartilage imaging with dGEMRIC has been established as an accurate and reliable tool for assessment of cartilage status in the knee and hip joint.This review outlines the current status of dGEMRIC for assessment of hip joint cartilage. Practical modifications of the standard technique including three-dimensional (3D) dGEMRIC and dGEMRIC after intra-articular gadolinium instead of iv-dGEMRIC will also be addressed.
Resumo:
Femoroacetabular impingement is a well-described pre-arthritic condition with two main types; cam and pincer. Studies using the open treatment for impingement have described patterns of articular cartilage wear specific to cam and pincer impingement. Assessing articular damage in the hip joint is an important component of treatment. Intravenous gadolidium allows radiologists to perform an indirect assessment of articular cartilage glycosaminoglycan (GAG) content by using a technique called dGEMRIC. Using this indirect assessment of articular cartilage, we compared the dGEMRIC indices in a group of six cam and seven pincer patients to a control group (n = 12) of asymptomatic controls that had no plain MRI findings of osteoarthritis. The superior portion of the hip joint was divided into seven regions from 9 to 3 o'clock. These regions were then subdivided into peripheral and central regions. The cam and pincer groups both had statistically lower dGEMRIC values compared to the control group. The cam group demonstrated not only peripheral but also central involvement of the joint and this was concentrated in the anterior portion of the joint. The pincer group exhibited more global hip involvement with all areas of the hip averaging a dGEMRIC index 28% less than controls. With the use of dGEMRIC more specific patterns of cartilage wear can be elicited in patients with impingement, which may improve patient selection and help better understand the progression of osteoarthithis throughout the hip joint.