908 resultados para Geometric attacks


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show how a quantum property, a geometric phase, associated with scattering states can be exhibited in nanoscale electronic devices. We propose an experiment to use interference to directly measure the effect of this geometric phase. The setup involves a double-path interferometer, adapted from that used to measure the phase evolution of electrons as they traverse a quantum dot (QD). Gate voltages on the QD could be varied cyclically and adiabatically, in a manner similar to that used to observe quantum adiabatic charge pumping. The interference due to the geometric phase results in oscillations in the current collected in the drain when a small bias across the device is applied. We illustrate the effect with examples of geometric phases resulting from both Abelian and non-Abelian gauge potentials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Asthma guidelines recommend increasing or doubling inhaled corticosteroid (ICS) dose to treat mild and moderate exacerbations of asthma in adults. Aim: To: (i) compare the effectiveness of doubling existing daily ICS dose (fluticasone) with maintaining usual ICS dose and usual daily ICS dose accompanied by oral steroids (OS) (dexamethasone) during mild and moderately severe exacerbations of asthma in adults; (ii) examine determinants of success and failure; and (iii) compare side-effect profiles. Methods: A randomized, double-blind, placebo-controlled (double-dummy), triple crossover trial. Participants acted as their own control. Outcome measures included treatment success/failure, peak expiratory flow (PEF) after 7 days therapy or at treatment failure, and side-effects. Results: From 22 participants (nine males and 13 females), 18 pairs of data were available for maintaining usual ICS versus doubling ICS and doubling ICS versus OS, and 19 for maintaining usual ICS versus OS. Median (fifth-95th percentile) age was 46.5 (32-64) years and forced expiratory volume in one second (FEV1) 73% (29-97%) predicted. The outcome after doubling ICS was not superior to maintaining usual ICS, with 11 (61%) failures in both arms (P = 0.66). OS, with only 5 (26%) failures, was superior to maintaining usual ICS with 12 (63%) failures (P = 0.04), and to doubling ICS with 5 (28%) versus 11 (61%) failures (P = 0.07). Median PEF (as percentage of run-in best) at end-points were 90.5% (57.1-177.1) for OS, 78.3% (39.5-103.1) for maintaining usual ICS and 77.9 (27.7-110.3) for doubling ICS. Neither gender nor PEF at exacerbation were predictive of failure. Although doubling ICS was not an effective therapy overall, ICS dose at exacerbation were predictive of success in the doubling ICS arm (P = 0.04). Treatment failures when doubling daily ICS dose were more common if achieved fluticasone dose was less than 2000 mu g (three of 11, 73%) compared to 2000 mu g or greater (eight of eight, 37.5%). Increasing age and the presence of an upper respiratory tract infection (URTI) were predictive of failure with OS. Side-effects were more commonly reported with OS (52.6%) than doubling ICS (42.1%) or maintaining usual ICS (19.1%) with the most common being mood changes (36.8%), sleep disturbance (31.6%) and changes in appetite (26.3%). Conclusions: Doubling daily ICS dose per se is not effective for the treatment of mild to moderately severe exacerbations of asthma in adults. Success may depend on achieved ICS dose. Oral steroids are effective, but side-effects are common. A review of current guidelines may be warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geometric phases of scattering states in a ring geometry are studied on the basis of a variant of the adiabatic theorem. Three timescales, i.e., the adiabatic period, the system time and the dwell time, associated with adiabatic scattering in a ring geometry play a crucial role in determining geometric phases, in contrast to only two timescales, i.e., the adiabatic period and the dwell time, in an open system. We derive a formula connecting the gauge invariant geometric phases acquired by time-reversed scattering states and the circulating (pumping) current. A numerical calculation shows that the effect of the geometric phases is observable in a nanoscale electronic device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What is the minimal size quantum circuit required to exactly implement a specified n-qubit unitary operation, U, without the use of ancilla qubits? We show that a lower bound on the minimal size is provided by the length of the minimal geodesic between U and the identity, I, where length is defined by a suitable Finsler metric on the manifold SU(2(n)). The geodesic curves on these manifolds have the striking property that once an initial position and velocity are set, the remainder of the geodesic is completely determined by a second order differential equation known as the geodesic equation. This is in contrast with the usual case in circuit design, either classical or quantum, where being given part of an optimal circuit does not obviously assist in the design of the rest of the circuit. Geodesic analysis thus offers a potentially powerful approach to the problem of proving quantum circuit lower bounds. In this paper we construct several Finsler metrics whose minimal length geodesics provide lower bounds on quantum circuit size. For each Finsler metric we give a procedure to compute the corresponding geodesic equation. We also construct a large class of solutions to the geodesic equation, which we call Pauli geodesics, since they arise from isometries generated by the Pauli group. For any unitary U diagonal in the computational basis, we show that: (a) provided the minimal length geodesic is unique, it must be a Pauli geodesic; (b) finding the length of the minimal Pauli geodesic passing from I to U is equivalent to solving an exponential size instance of the closest vector in a lattice problem (CVP); and (c) all but a doubly exponentially small fraction of such unitaries have minimal Pauli geodesics of exponential length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serial reduction in scar thickness has been shown in animal models. We sought whether this reduction in scar thickness may be a result of dilatation of the left ventricle (LV) with stretching and thinning of the wall. Contrast enhanced magnetic resonance imaging (CMRI) was performed to delineate radial scar thickness in 25 patients (age 63±10, 21 men) after myocardial infarction. The LV was divided into 16 segts and the absolute radial scar thickness (ST) and percentage scar to total wall thickness (%ST) were measured. Regional end diastolic (EDV) and end systolic volumes (ESV) of corresponding segments were measured on CMRI. All patients underwent revascularization and serial changes in ST, %ST, and regional volumes were assessed with a mean follow up of 15±5 months. CMRI identified a total of 93 scar segments. An increase in EDV or ESV was associated with a serial reduction inST(versusEDV, r =−0.3, p = 0.01; versusESV, r =−0.3, p = 0.005) and%ST(versusEDV, r =−0.2, p = 0.04; versus ESV, r =−0.3, p = 0.001). For segts associated with a positive increase in EDV (group I) or ESV (group II) there was a significant decrease in ST and %ST, but in those segts with stable EDV (group III) or ESV (group IV) there were no significant changes in ST and %ST (Table).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper incorporates hierarchical structure into the neoclassical theory of the firm. Firms are hierarchical in two respects: the organization of workers in production and the wage structure. The firm’s hierarchy is represented as the sector of a circle, where the radius represents the hierarchy’s height, the width of the sector represents the breadth of the hierarchy at a given height, and the angle of the sector represents span of control for any given supervisor. A perfectly competitive firm then chooses height and width, as well as capital inputs, in order to maximize profit. We analyze the short run and long run impact of changes in scale economies, input substitutability and input and output prices on the firm’s hierarchical structure. We find that the firm unambiguously becomes more hierarchical as the specialization of its workers increases or as its output price increases relative to input prices. The effect of changes in scale economies is contingent on the output price. The model also brings forth an analysis of wage inequality within the firm, which is found to be independent of technological considerations, and only depends on the firm’s wage schedule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Security protocols are often modelled at a high level of abstraction, potentially overlooking implementation-dependent vulnerabilities. Here we use the Z specification language's rich set of data structures to formally model potentially ambiguous messages that may be exploited in a 'type flaw' attack. We then show how to formally verify whether or not such an attack is actually possible in a particular protocol using Z's schema calculus.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings of the 11th Australasian Remote Sensing and Photogrammetry Conference

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neural networks can be regarded as statistical models, and can be analysed in a Bayesian framework. Generalisation is measured by the performance on independent test data drawn from the same distribution as the training data. Such performance can be quantified by the posterior average of the information divergence between the true and the model distributions. Averaging over the Bayesian posterior guarantees internal coherence; Using information divergence guarantees invariance with respect to representation. The theory generalises the least mean squares theory for linear Gaussian models to general problems of statistical estimation. The main results are: (1)~the ideal optimal estimate is always given by average over the posterior; (2)~the optimal estimate within a computational model is given by the projection of the ideal estimate to the model. This incidentally shows some currently popular methods dealing with hyperpriors are in general unnecessary and misleading. The extension of information divergence to positive normalisable measures reveals a remarkable relation between the dlt dual affine geometry of statistical manifolds and the geometry of the dual pair of Banach spaces Ld and Ldd. It therefore offers conceptual simplification to information geometry. The general conclusion on the issue of evaluating neural network learning rules and other statistical inference methods is that such evaluations are only meaningful under three assumptions: The prior P(p), describing the environment of all the problems; the divergence Dd, specifying the requirement of the task; and the model Q, specifying available computing resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.