958 resultados para GAS-PHASE REACTIONS
Resumo:
A study was carried out on the urea geometries using ab initio calculation and Monte Carlo computational simulation of liquids. The ab initio calculated results showed that urea has a non-planar conformation in the gas phase in which the hydrogen atoms are out of the plane formed by the heavy atoms. Free energies associated to the rotation of the amino groups of urea in water were obtained using the Monte Carlo method in which the thermodynamic perturbation theory is implemented. The magnitude of the free energy obtained from this simulation did not permit us to conclude that urea is non-planar in water.
Resumo:
A novel cantilever pressure sensor was developed in the Department of Physics at the University of Turku in order to solve the sensitivity problems which are encountered when condenser microphones are used in photoacoustic spectroscopy. The cantilever pressure sensor, combined with a laser interferometer for the measurement of the cantilever movements, proved to be highly sensitive. The original aim of this work was to integrate the sensor in a photoacoustic gas detector working in a differential measurement scheme. The integration was made successfully into three prototypes. In addition, the cantilever was also integrated in the photoacoustic FTIR measurement schemes of gas-, liquid-, and solid-phase samples. A theoretical model for the signal generation in each measurement scheme was created and the optimal celldesign discussed. The sensitivity and selectivity of the differential method were evaluated when a blackbody radiator and a mechanical chopper were used with CO2, CH4, CO, and C2H4 gases. The detection limits were in the sub-ppm level for all four gases with only a 1.3 second integration time and the cross interference was well below one percent for all gas combinations other than those between hydrocarbons. Sensitivity with other infrared sources was compared using ethylene as an example gas. In the comparison of sensitivity with different infrared sources the electrically modulated blackbody radiator gave a 35 times higher and the CO2-laser a 100 times lower detection limit than the blackbody radiator with a mechanical chopper. As a conclusion, the differential system is well suited to rapid single gas measurements. Gas-phase photoacoustic FTIR spectroscopy gives the best performance, when several components have to be analyzed simultaneously from multicomponent samples. Multicomponent measurements were demonstrated with a sample that contained different concentrations of CO2, H2O, CO, and four different hydrocarbons. It required an approximately 10 times longer measurement time to achieve the same detection limit for a single gas as with the differential system. The properties of the photoacoustic FTIR spectroscopy were also compared to conventional transmission FTIR spectroscopy by simulations. Solid- and liquid-phase photoacoustic FTIR spectroscopy has several advantages compared to other techniques and therefore it also has a great variety of applications. A comparison of the signal-to-noise ratio between photoacoustic cells with a cantilever microphone and a condenser microphone was done with standard carbon black, polyethene, and sunflower oil samples. The cell with the cantilever microphone proved to have a 5-10 times higher signal-to-noise ratio than the reference detector, depending on the sample. Cantilever enhanced photoacoustics will be an effective tool for gas detection and analysis of solid- and liquid-phase samples. The preliminary prototypes gave good results in all three measurement schemes that were studied. According to simulations, there are possibilities for further enhancement of the sensitivity, as well as other properties, of each system.
Resumo:
Although electrospray ionization mass spectrometry (ES-MS) has been extensively applied to study organic and biochemical species, it is also specially suitable to study inorganic and organo-metallic species. Such species, even those that are low-volatile or thermo-unstable, can be easily ionized or simply transferred from liquid to gas phase by electrospray. However, chemical transformations frequently occur during the process. This paper discusses the fundamental aspects of electrospray ionization as well as its analytical applicability to inorganic and organo-metallic species in order to spread the technique and make its characteristics more familiar to potential users.
Resumo:
The ellipticines constitute a broad class of molecules with antitumor activity. In the present work we analyzed the structure and properties of a series of ellipticine derivatives in the gas phase and in solution using quantum mechanical and Monte Carlo methods. The results showed a good correlation between the solvation energies in water obtained with the continuum model and the Monte Carlo simulation. Molecular descriptors were considered in the development of QSAR models using the DNA association constant (log Kapp) as biological data. The results showed that the DNA binding is dominated by electronic parameters, with small contributions from the molecular volume and area.
Resumo:
Polarizability correlates well with organic ion stabilization in solution and can be defined as a measure of the relative ease of the distortion of the electronic cloud of a dipolar system exposed to an external electric field. The effective atomic polarizability, alphad, has a fundamental influence on chemical reactivity in the gas phase and in solution. In terms of chemical reactivity the charge is generated within the molecule as a positive charge due to protonation, ionization or resulting from the attack of a nucleophilic anion. In this paper, lipoidal diaminedithiol (DADT) perfusion radioligands based on 99Tc m and possessing an alkylamine side chain have been used to check the influence of alphad on their brain uptake. Some new DADT derivatives, respectively DADT-DIPA (diaminedithiol - diisopropylamine), DADT DIBA (diaminedithiol diisobutylamine), DADT-PR (diaminedithiol - branched pyperidine), have been designed to have high nitrogen alkylamine alphad values. In spite of the fact of higher alphad values having been correlated to higher brain uptakes, there isn't a clear mechanism able to trap these radioligands into the brain space.
Resumo:
In this work the most abundant trehalose conformers for the isolated molecule as well as for the water solvated system are selected. The theoretical tecniques employed are ab initio calculations in the gas phase and in aqueous solution using the PCM model. A conformational map is built for the glycosidic angles (phi and psi) and the search for the most abundant structures is explained. The final structures are validated by the agreement found between experimental and theoretical values for ³J H,C along the glycosidic linkage.
Resumo:
The field of application of mass spectrometry (MS) has increased considerably due to the development of ionization techniques. Other factors that have stimulated the use of MS are the tandem mass spectrometry (MS/MS) and sequential mass spectrometry (MSn) techniques. However, the interpretation of the MS/MS and MSn data may lead to speculative conclusions. Thus, various quantum chemical methods have been applied for obtaining high quality thermochemical data in gas phase. In this review, we show some applications of computational quantum chemistry to understand the formation and fragmentation of gaseous ions of organic compounds in a MS analysis.
Resumo:
An absolute method is described via mass spectrometry (MS) for the structural assignment of isomers within the class of methylpiperidines. The method explores both the unimolecular and bimolecular gas phase behavior of structurally diagnostic fragment ions (SDFI). For the methylpiperidnes, the isomeric 2-methyl, 3-methyl and 4-methyl 2-azabutadienyl cations are found to function as SDFI. These fragment ions are expected to be formed from all members within the class, to be stable and to retain the structural information of the precursor molecule, and to not interconvert into one another. To characterize these SDFI, both the collision induced dissociation (CID) in argon and bimolecular ion/molecule chemistry with ethyl vinyl ether were compared.
Resumo:
Friedelin molecular conformers were obtained by Density Functional Theory (DFT) and by ab initio structure determination from powder X-ray diffraction. Their conformers with the five rings in chair-chair-chair-boat-boat, and with all rings in chair, are energy degenerated in gas-phase according to DFT results. The powder diffraction data reveals that rings A, B and C of friedelin are in chair, and rings D and E in boat-boat, conformation. The high correlation values among powder diffraction data, DFT and reported single-crystal data indicate that the use of conventional X-ray diffractometer can be applied in routine laboratory analysis in the absence of a single-crystal diffractometer.
Resumo:
A new method using the headspace solid phase microextraction (HS-SPME) technique was used to evaluate the infinite dilute activity coefficient (γ1∞) in an alcohol/water/salt system. The studied systems were ethanol and water with NaCl and NH4Cl at salt concentrations of 5, 10, 15, and 30% m/v and temperatures of 303.15 and 313.15 K. The method was used to investigate the salt effect on vapor/liquid equilibrium in an ethanol/water system, yielding satisfactory results. The study focused on the rich side in ethanol. The data were compared with the literature infinite dilution data determined by other methods such as differential ebulliometry (EBUL), differential static cell equilibrium (STAT), and gas-liquid chromatography with no gas phase correction (GC). In this study, NaCl showed better separation rates than NH4Cl.
Resumo:
In this thesis three experiments with atomic hydrogen (H) at low temperatures T<1 K are presented. Experiments were carried out with two- (2D) and three-dimensional (3D) H gas, and with H atoms trapped in solid H2 matrix. The main focus of this work is on interatomic interactions, which have certain specific features in these three systems considered. A common feature is the very high density of atomic hydrogen, the systems are close to quantum degeneracy. Short range interactions in collisions between atoms are important in gaseous H. The system of H in H2 differ dramatically because atoms remain fixed in the H2 lattice and properties are governed by long-range interactions with the solid matrix and with H atoms. The main tools in our studies were the methods of magnetic resonance, with electron spin resonance (ESR) at 128 GHz being used as the principal detection method. For the first time in experiments with H in high magnetic fields and at low temperatures we combined ESR and NMR to perform electron-nuclear double resonance (ENDOR) as well as coherent two-photon spectroscopy. This allowed to distinguish between different types of interactions in the magnetic resonance spectra. Experiments with 2D H gas utilized the thermal compression method in homogeneous magnetic field, developed in our laboratory. In this work methods were developed for direct studies of 3D H at high density, and for creating high density samples of H in H2. We measured magnetic resonance line shifts due to collisions in the 2D and 3D H gases. First we observed that the cold collision shift in 2D H gas composed of atoms in a single hyperfine state is much smaller than predicted by the mean-field theory. This motivated us to carry out similar experiments with 3D H. In 3D H the cold collision shift was found to be an order of magnitude smaller for atoms in a single hyperfine state than that for a mixture of atoms in two different hyperfine states. The collisional shifts were found to be in fair agreement with the theory, which takes into account symmetrization of the wave functions of the colliding atoms. The origin of the small shift in the 2D H composed of single hyperfine state atoms is not yet understood. The measurement of the shift in 3D H provides experimental determination for the difference of the scattering lengths of ground state atoms. The experiment with H atoms captured in H2 matrix at temperatures below 1 K originated from our work with H gas. We found out that samples of H in H2 were formed during recombination of gas phase H, enabling sample preparation at temperatures below 0.5 K. Alternatively, we created the samples by electron impact dissociation of H2 molecules in situ in the solid. By the latter method we reached highest densities of H atoms reported so far, 3.5(5)x1019 cm-3. The H atoms were found to be stable for weeks at temperatures below 0.5 K. The observation of dipolar interaction effects provides a verification for the density measurement. Our results point to two different sites for H atoms in H2 lattice. The steady-state nuclear polarizations of the atoms were found to be non-thermal. The possibility for further increase of the impurity H density is considered. At higher densities and lower temperatures it might be possible to observe phenomena related to quantum degeneracy in solid.
Resumo:
Tässä kirjallisuustyössä tutkittiin atomikerroskasvatuksen (ALD) soveltamista kemiantekniikassa. Työn alussa kerrottiin atomikerroskasvatuksesta, sen toimintaperiaatteista ja prosessitekniikasta. Tämän jälkeen tutkittiin viittä eri kemiantekniikan sovellusta, jotka olivat polymeerien pinnoittaminen, heterogeenisten katalyyttien syntetisointi, membraanien modifiointi, korroosionesto ja kaasunilmaisimet. ALD on ohutkalvotekniikka, jolla voidaan valmistaa nanometrin tai jopa Ångströmin (1 Å = 0.1 nm) tarkkuudella epäorgaanisia materiaalikerroksia, jotka yleensä ovat metallioksideja, kuten alumiinioksidi. ALD perustuu kaasu-kiintoainereaktioihin, joissa kaasumaiset kemialliset prekursorit reagoivat vuorotellen kasvualustan kanssa. Tyypilliset prekursorit ovat metalliligandi ja vesi, joka on yleisin hapen lähde ALD-reaktioissa. ALD−reaktiot suoritetaan yleensä matalassa paineessa (100−200 Pa) ja korkeassa lämpötilassa (200–400 °C) suljetussa reaktorikammiossa. ALD-prosesseissa voidaan hyödyntää myös plasmaa alentamaan reaktiolämpötiloja. Plasman avulla prekursoreista luodaan hyvin reaktiivisia radikaaleja, jotka voivat reagoida jopa huoneenlämmössä. Lämpöherkkiä polymeerejä voidaan pinnoittaa ohutkalvoilla, joilla voidaan lisätä esimerkiksi pakkausmateriaalien suojaa happea ja vesihöyryä vastaan. ALD:llä voidaan syntetisoida tarkasti nanomittakaavan heterogeenisiä katalyyttejä, joilla on korkea dispersio tukimateriaalin pinnalla. ALD:n avulla voidaan säästää katalyyttimateriaalia menettämättä katalyytin aktiivisuutta, mikä on tärkeää monien katalyyttisovellusten taloudellisuuden kannalta, esimerkiksi polttokennot. ALD soveltuu hyvin membraanien modifiointiin, koska kaasumaiset prekursorit leviävät tasaisesti membraanin huokosiin. Membraanien pinnoittamisella pyritään vaikuttamaan, selektiivisyyteen, hydrofiilisyyteen, liuotinkestävyyteen, huokoskokoon ja sen jakaumaan. Lisäksi membraaneja voidaan pinnoittaa katalyyttisillä ohutkalvoilla, mikä on tärkeää nanoreaktoreiden kehityksen kannalta. ALD:llä voidaan pinnoittaa esimerkiksi terästä, ja vähentää täten teräksen korroosiota. Puolijohtavia metallioksideja voidaan käyttää kaasunilmaisimina, joiden valmistuksessa ALD:n tarkkuudesta on suurta hyötyä.
Resumo:
Kandidaatintyön johdantokappaleessa esitellään vetyperoksidi ja mihin sitä käytetään teollisuudessa. Työssä vertaillaan antrakinoniprosessia ja suoraa prosessia sekä selvitetään nykyisin enemmän vetyperoksidituotantoon käytetyn antrakinoniprosessin ongelmakohdat ja osoitetaan, miksi suora synteesi vetyperoksidin tuotannossa olisi parempi vaihtoehto. Kandidaatintyön käsittelee suurilta osin turvallisuusongelmia, joita esiintyy suoran synteesin yhteydessä. Kirjallisuudesta on etsitty ratkaisuja näihin ongelmiin, kuten membraaniprosessin käyttöä räjähdysvaaran välttämiseksi. Pienemmän reaktorin eli ns. mikroreaktorin käyttö tuo mukanaan monia etuja vetyperoksidin tuotantoon. Tällöin prosessi on turvallisempi ja sitä on helpompi hallita. Mikroreaktorissa voidaan käyttää korkeampia lämpötiloja ja paineita kuin makroreaktorilla ilman, että räjähdysvaara prosessissa kasvaisi. Mikroreaktorin sisällä olevat mikrokanavat luovat turvallisen ympäristön synteesille. Aspen plus – simulointiohjelmalla mallinnettiin ja simulointiin suoran prosessin kriittisiä virtoja mikroreaktorissa. Tarkoituksena oli löytää virrat, joissa kulkee mahdollisesti räjähtävä kaasuseos. Kaasumaiset prosessivirrat ovat kriittisimmät vetyperoksidin suorassa synteesissä, koska ne aiheuttavat todennäköisemmin räjähdyksen kuin nestemäiset prosessivirrat. Kaikkein eniten prosessiturvallisuutta uhkaavat ainevirrat ennen ja jälkeen mikroreaktoria.
Resumo:
In this study, cantilever-enhanced photoacoustic spectroscopy (CEPAS) was applied in different drug detection schemes. The study was divided into two different applications: trace detection of vaporized drugs and drug precursors in the gas-phase, and detection of cocaine abuse in hair. The main focus, however, was the study of hair samples. In the gas-phase, methyl benzoate, a hydrolysis product of cocaine hydrochloride, and benzyl methyl ketone (BMK), a precursor of amphetamine and methamphetamine were investigated. In the solid-phase, hair samples from cocaine overdose patients were measured and compared to a drug-free reference group. As hair consists mostly of long fibrous proteins generally called keratin, proteins from fingernails and saliva were also studied for comparison. Different measurement setups were applied in this study. Gas measurements were carried out using quantum cascade lasers (QLC) as a source in the photoacoustic detection. Also, an external cavity (EC) design was used for a broader tuning range. Detection limits of 3.4 particles per billion (ppb) for methyl benzoate and 26 ppb for BMK in 0.9 s were achieved with the EC-QCL PAS setup. The achieved detection limits are sufficient for realistic drug detection applications. The measurements from drug overdose patients were carried out using Fourier transform infrared (FTIR) PAS. The drug-containing hair samples and drug-free samples were both measured with the FTIR-PAS setup, and the measured spectra were analyzed statistically with principal component analysis (PCA). The two groups were separated by their spectra with PCA and proper spectral pre-processing. To improve the method, ECQCL measurements of the hair samples, and studies using photoacoustic microsampling techniques, were performed. High quality, high-resolution spectra with a broad tuning range were recorded from a single hair fiber. This broad tuning range of an EC-QCL has not previously been used in the photoacoustic spectroscopy of solids. However, no drug detection studies were performed with the EC-QCL solid-phase setup.
Resumo:
Ion mobility spectrometry (IMS) is a straightforward, low cost method for fast and sensitive determination of organic and inorganic analytes. Originally this portable technique was applied to the determination of gas phase compounds in security and military use. Nowadays, IMS has received increasing attention in environmental and biological analysis, and in food quality determination. This thesis consists of literature review of suitable sample preparation and introduction methods for liquid matrices applicable to IMS from its early development stages to date. Thermal desorption, solid phase microextraction (SPME) and membrane extraction were examined in experimental investigations of hazardous aquatic pollutants and potential pollutants. Also the effect of different natural waters on the extraction efficiency was studied, and the utilised IMS data processing methods are discussed. Parameters such as extraction and desorption temperatures, extraction time, SPME fibre depth, SPME fibre type and salt addition were examined for the studied sample preparation and introduction methods. The observed critical parameters were extracting material and temperature. The extraction methods showed time and cost effectiveness because sampling could be performed in single step procedures and from different natural water matrices within a few minutes. Based on these experimental and theoretical studies, the most suitable method to test in the automated monitoring system is membrane extraction. In future an IMS based early warning system for monitoring water pollutants could ensure the safe supply of drinking water. IMS can also be utilised for monitoring natural waters in cases of environmental leakage or chemical accidents. When combined with sophisticated sample introduction methods, IMS possesses the potential for both on-line and on-site identification of analytes in different water matrices.