946 resultados para GAS-LIQUID FLOW
Resumo:
The laminar low Mach number flow of a gas in a tube is analyzed for very small and very large values of the inlet-to-wall temperature ratio. When this ratio tends to zero, pressure forces confine the cold gas to a thin core around the axis of the tube. This core is neatly bounded by an ablation front that consumes it at a finite distance from the tube inlet. When the temperature ratio tends to infinity, the temperature of the gas increases smoothly from the wall to the axis of the tube and the shear stress and heat flux are positive at the wall despite the fact that the viscosity and thermal conductivity of the gas scaled with their inlet values tend to zero at the wall
Resumo:
In this work, an analytical method was developed for the determination of pharmaceutical drugs inbiosolids. Samples were extracted with an acidic mixture of water and acetone (1:2, v/v) and supportedliquid extraction was used for the clean-up of extracts, eluting with ethyl acetate:methanol (90:10, v/v).The compounds were determined by gas chromatography?tandem mass spectrometry using matrix-match calibration after silylation to form their t-butyldimethylsilyl derivatives. This method presentsvarious advantages, such as a fairly simple operation for the analysis of complex matrices, the use ofinexpensive glassware and low solvent volumes. Satisfactory mean recoveries were obtained with thedeveloped method ranging from 70 to 120% with relative standard deviations (RSDs) ? 13%, and limitsof detection between 0.5 and 3.6 ng g?1. The method was then successfully applied to biosolids samplescollected in Madrid and Catalonia (Spain). Eleven of the sixteen target compounds were detected in thestudied samples, at levels up to 1.1 ?g g?1(salicylic acid). Ibuprofen, caffeine, paracetamol and fenofibratewere detected in all of the samples analyzed.
Resumo:
The classical problem of thermal explosion is modified so that the chemically active gas is not at rest but is flowing in a long cylindrical pipe. Up to a certain section the heat-conducting walls of the pipe are held at low temperature so that the reaction rate is small and there is no heat release; at that section the ambient temperature is increased and an exothermic reaction begins. The question is whether a slow reaction regime will be established or a thermal explosion will occur. The mathematical formulation of the problem is presented. It is shown that when the pipe radius is larger than a critical value, the solution of the new problem exists only up to a certain distance along the axis. The critical radius is determined by conditions in a problem with a uniform axial temperature. The loss of existence is interpreted as a thermal explosion; the critical distance is the safe reactor’s length. Both laminar and developed turbulent flow regimes are considered. In a computational experiment the loss of the existence appears as a divergence of a numerical procedure; numerical calculations reveal asymptotic scaling laws with simple powers for the critical distance.
Resumo:
Measurement of 8-hydroxy-2′-deoxyguanosine (8-OH-dGuo) in DNA by high-performance liquid chromatography/mass spectrometry (LC/MS) was studied. A methodology was developed for separation by LC of 8-OH-dGuo from intact and modified nucleosides in DNA hydrolyzed by a combination of four enzymes: DNase I, phosphodiesterases I and II and alkaline phosphatase. The atmospheric pressure ionization-electrospray process was used for mass spectral measurements. A stable isotope-labeled analog of 8-OH-dGuo was used as an internal standard for quantification by isotope-dilution MS (IDMS). Results showed that LC/IDMS with selected ion-monitoring (SIM) is well suited for identification and quantification of 8-OH-dGuo in DNA at background levels and in damaged DNA. The sensitivity level of LC/IDMS-SIM was found to be comparable to that reported previously using LC-tandem MS (LC/MS/MS). It was found that approximately five lesions per 106 DNA bases can be detected using amounts of DNA as low as 2 µg. The results also suggest that this lesion may be quantified in DNA at levels of one lesion per 106 DNA bases, or even lower, when more DNA is used. Up to 50 µg of DNA per injection were used without adversely affecting the measurements. Gas chromatography/isotope-dilution MS with selected-ion monitoring (GC/IDMS-SIM) was also used to measure this compound in DNA following its removal from DNA by acidic hydrolysis or by hydrolysis with Escherichia coli Fpg protein. The background levels obtained by LC/IDMS-SIM and GC/IDMS-SIM were almost identical. Calf thymus DNA and DNA isolated from cultured HeLa cells were used for this purpose. This indicates that these two techniques can provide similar results in terms of the measurement of 8-OH-dGuo in DNA. In addition, DNA in buffered aqueous solution was damaged by ionizing radiation at different radiation doses and analyzed by LC/IDMS-SIM and GC/IDMS-SIM. Again, similar results were obtained by the two techniques. The sensitivity of GC/MS-SIM for 7,8-dihydro-8-oxoguanine was also examined and found to be much greater than that of LC/MS-SIM and the reported sensitivity of LC/MS/MS for 8-OH-dGuo. Taken together, the results unequivocally show that LC/IDMS-SIM is well suited for sensitive and accurate measurement of 8-OH-dGuo in DNA and that both LC/IDMS-SIM and GC/IDMS-SIM can provide similar results.
Resumo:
A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L−1. Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71–116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.
Resumo:
An experiment was conceived in which we monitored degradation of GlcDGD. Independent of the fate of the [14C]glucosyl headgroup after hydrolysis from the glycerol backbone, the 14C enters the aqueous or gas phase whereas the intact lipid is insoluble and remains in the sediment phase. Total degradation of GlcDGD then is obtained by combining the increase of radioactivity in the aqueous and gaseous phases. We chose two different sediment to perform this experiment. One is from microbially actie surface sediment sampled in February 2010 from the upper tidal flat of the German Wadden Sea near Wremen (53° 38' 0N, 8° 29' 30E). The other one is deep subsurface sediments recovered from northern Cascadia Margin during Integrated Ocean Drilling Program Expedition 311 [site U1326, 138.2 meters below seafloor (mbsf), in situ temperature 20 °C, water depth 1,828 m. We performed both alive and killed control experiments for comparison. Surface and subsurface sediment slurry were incubated in the dark at in situ temperature, 4 °C and 20 °C for 300 d, respectively. The sterilized slurry was stored at 20 °C. All incubations were carried out under N2 headspace to ensure anaerobic conditions. The sampling frequency was high during the first half-month, i.e., after 1, 2, 7, and 14 d; thereafter, the sediment slurry was sampled every 2 months. At each time point, samples were taken in triplicate for radioactivity measurements. After 300 d of incubation, no significant changes of radioactivity in the aqueous phase were detected. This may be the result of either the rapid turnover of released [14C] glucose or the relatively high limit of detection caused by the slight solubility (equivalent to 2% of initial radioactivity) of GlcDGD in water. Therefore, total degradation of GlcDGD in the dataset was calculated by combining radioactivity of DIC, CH4, and CO2, leading to a minimum estimate.
Resumo:
"Gas entrainment, indicated by visual bubbles in the mercury, led to low heat transfer rates which were increased by increasing the static pressure. Suitable changes in the flow system resulted in a reduction of this entrainment effect and an increase in heat transfer performance."--Page iii.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
"TR63-217F."
Resumo:
Mode of access: Internet.