997 resultados para Fungal exposure
Resumo:
Results of a HIV prevalence study conducted in hemophiliacs from Belo Horizonte, Brazil are presented. History of exposure to acellular blood components was determined for the five year period prior to entry in the study, which occurred during 1986 and 1987. Patients with coagulations disorders (hemophilia A = 132, hemophilia B = 16 and coagulation disorders other than hemophilia = 16) were transfused with liquid cryoprecipitate, locally produced, lyophilized cryoprecipitate, imported from São Paulo (Brazil) and factor VIII and IX, imported from Rio de Janeiro (Brazil), Europe, and United States. Thirty six (22%) tested HIV seropositive. The univariate and multivariate analysis (logistic model) demonstrated that the risk of HIV infection during the study period was associated with the total units of acellular blood components transfused. In addition, the proportional contribution of the individual components to the total acellular units transfused, namely a increase in factor VIII/IX and lyophilized cryoprecipitate proportions, were found to be associated with HIV seropositivity. This analysis suggest that not only the total amount of units was an important determinant of HIV infection, but that the risk was also associated with the specific component of blood transfused
Resumo:
This paper describes the use of a Control Banding Tool to assess and further control of exposure of nanoparticles emitted during welding operations. The tool was applied to Metal Active Gas (MAG) arc welding of mild and stainless steel, providing semi-quantitative data on the process, so that protection measures could be derived, e.g. exhaust gas ventilation by hoods, local ventilation devices and containment measures. This tool is quite useful to compare and evaluate the characteristics of arc welding procedures so that more eco-friendly processes could be preferred over the more potentially noxious ones.
Resumo:
Hospitals are considered as a special and important type of indoor public place where air quality has significant impacts on potential health outcomes. Information on indoor air quality of these environments, concerning exposures to particulate matter (PM) and related toxicity, is limited though. This work aims to evaluate risks associated with inhalation exposure to ten toxic metals and chlorine (As, Ni, Cr, Cd, Pb, Mn, Se, Ba, Al, Si, and Cl) in coarse (PM2.5–10) and fine (PM2.5) particles in a Portuguese hospital in comparison with studies representative of other countries. Samples were collected during 1 month in one urban hospital; elemental PM characterization was determined by proton-induced X-ray emission. Noncarcinogenic and carcinogenic risks were assessed according to the methodology provided by the United States Environmental Protection Agency (USEPA; Region III Risk-Based Concentration Table) for three different age categories of hospital personnel (adults, >20, and <65 years) and patients (considering nine different age groups, i.e., children of 1–3 years to seniors of >65 years). The estimated noncarcinogenic risks due to occupational inhalation exposure to PM2.5-bound metals ranged from 5.88×10−6 for Se (adults, 55–64 years) to 9.35×10−1 for As (adults, 20–24 years) with total noncarcinogenic risks (sum of all metals) above the safe level for all three age categories. As and Cl (the latter due to its high abundances) were the most important contributors (approximately 90 %) to noncarcinogenic risks. For PM2.5–10, noncarcinogenic risks of all metals were acceptable to all age groups. Concerning carcinogenic risks, for Ni and Pb, they were negligible (<1×10−6) in both PM fractions for all age groups of hospital personnel; potential risks were observed for As and Cr with values in PM2.5 exceeding (up to 62 and 5 times, respectively) USEPA guideline across all age groups; for PM2.5–10, increased excess risks of As and Cr were observed particularly for long-term exposures (adults, 55–64 years). Total carcinogenic risks highly (up to 67 times) exceeded the recommended level for all age groups, thus clearly showing that occupational exposure to metals in fine particles pose significant risks. If the extensive working hours of hospital medical staff were considered, the respective noncarcinogenic and carcinogenic risks were increased, the latter for PM2.5 exceeding the USEPA cumulative guideline of 10−4. For adult patients, the estimated noncarcinogenic and carcinogenic risks were approximately three times higher than for personnel, with particular concerns observed for children and adolescents.
Resumo:
The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5-year-old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82x104 and 1.32x104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15x104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17x104, 3.28x104, and 4.09x104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31x103, 11.3x103, and 7.14x103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5-year-old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.
Resumo:
The currently used pre-exposure anti-rabies immunization schedule in Brazil is the one called 3+1, employing suckling mouse brain vaccine (3 doses on alternate days and the last one on day 30). Although satisfactory results were obtained in well controlled experimental groups using this immunization schedule, in our routine practice, VNA levels lower than 0.5 IU/ml are frequently found. We studied the pre-exposure 3+1 schedule under field conditions in different cities on the State of São Paulo, Brazil, under variable and sometimes adverse circumstances, such as the use of different batches of vaccine with different titers, delivered, stored and administered under local conditions. Fifty out of 256 serum samples (19.5%) showed VNA titers lower than 0.5 IU/ml, but they were not distributed homogeneously among the localities studied. While in some cities the results were completely satisfactory, in others almost 40% did not attain the minimum VNA titer required. The results presented here, considered separately, question our currently used procedures for human pre-exposure anti-rabies immunization. The reasons determining this situation are discussed.
Resumo:
This study reports preliminary results of virus neutralizing antibody (VNA) titers obtained on different days in the course of human anti-rabies immunization with the 2-1-1 schedule (one dose is given in the right arm and one dose in the left arm at day 0, and one dose is apllied on days 7 and 21), recommended by WHO for post-exposure treatment with cell culture vaccines. A variant schedule (double dose on day zero and another on day 14) was also tested, both employing suckling mouse brain vaccine. A complete seroconversion rate was obtained after only 3 vaccine doses, and almost all patients (11 of 12) presented titers higher than 1.0 IU/ml. Both neutralizing response and seroconversion rates were lower in the group receiving only 3 doses, regardless of the sample collecting day. Although our results are lower than those found with cell culture vaccines, the geometry mean of VNA is fully satisfactory, overcoming the lower limit recommended by WHO of 0.5 IU/ml. The 2-1-1 schedule could be an alternative one for pre exposure immunization, shorter than the classical 3+1 regimen (one dose on days 0, 2, 4 and 30) with only three visits to the doctor, instead of four.
Resumo:
RESUMO - Os trabalhadores dos ginásios com piscinas apresentam maior prevalência de lesões fúngicas, como a Tinea pedis e a onicomicose, devido às características intrínsecas da sua actividade profissional, pois apresentam mais horas por dia de exposição à contaminação fúngica das superfícies. Esta situação verifica-se não só por serem os que mais frequentam os locais possíveis de estarem contaminados, como é o caso de balneários, vestiários e zona envolvente às piscinas, mas também porque algumas das actividades desenvolvidas são realizadas com os pés descalços. Além disso, a utilização de roupa sintética e de calçado ocluso, que retêm a sudação excessiva, favorece o desenvolvimento fúngico. Constituiu objectivo deste trabalho conhecer o risco de infecção e/ou lesão (Tinea pedis e onicomicose) nos trabalhadores dos ginásios com piscina e a sua eventual relação com a exposição à contaminação fúngica (ar e superfícies) dos locais de trabalho. Foram descritas as variáveis ambientais e biológicas que influenciam a infecção e/ou lesão fúngica em ambiente profissional e exploradas eventuais associações entre essas mesmas variáveis. Foram também conhecidas as diferenças da contaminação fúngica das superfícies entre as duas principais estações do ano (Verão e Inverno) e entre antes e depois da lavagem e desinfecção. O estudo realizado possui uma componente transversal, em que se pretendeu descrever os fenómenos ambientais e biológicos da contaminação fúngica em ambiente profissional e explorar eventuais associações entre variáveis; uma componente longitudinal, em que foram conhecidas as diferenças sazonais da contaminação fúngica das superfícies; e, ainda, uma componente quase experimental, em que foi analisada a distribuição fúngica nas superfícies antes e depois da lavagem e desinfecção. Na vertente transversal foi considerada uma amostra de 10 ginásios com piscina e outra amostra de, pelo menos, 10 profissionais de cada estabelecimento, perfazendo um total de 124 trabalhadores (75 Homens - 60,48% e 49 Mulheres - 39,52%). Foram realizadas 258 colheitas biológicas aos pés dos trabalhadores, efectuada a avaliação ambiental da contaminação fúngica dos estabelecimentos através de 50 colheitas de amostras de ar e 120 colheitas de amostras de superfícies (60 antes e 60 depois da lavagem e desinfecção) e efectuados os respectivos processamento laboratorial e identificação fúngica. Foram também avaliadas as variáveis ambientais temperatura, humidade relativa e velocidade do ar, preenchidas 10 grelhas de observação, com o objectivo de efectuar o registo de informação sobre as variáveis que xx influenciam a exposição ocupacional às espécies fúngicas e, ainda, completadas 124 grelhas de observação inerentes à colheita de material biológico, de modo a realizar o registo dos profissionais com lesão e outras informações pertinentes para a análise laboratorial. Todos os 124 trabalhadores responderam a um questionário, em simultâneo à realização das colheitas biológicas, de modo a conhecer algumas das variáveis individuais e profissionais com pertinência para o presente estudo. Num dos estabelecimentos, foram também estudadas as diferenças da contaminação fúngica das superfícies entre antes e depois da lavagem e desinfecção e, ainda, entre as duas estações do ano (Verão e Inverno). Nesse estabelecimento, foram realizadas 36 colheitas de superfícies antes e 36 colheitas depois da lavagem e desinfecção, em 6 dias diferentes da semana, durante 6 semanas sequenciais em cada estação do ano, completando um total de 72 colheitas de superfícies. Foi ainda criado e aplicado um método para estabelecer um padrão de exposição profissional a fungos nas superfícies, de modo a permitir definir níveis semi-quantitativos de estimação do risco de infecção fúngica dos trabalhadores dos ginásios com piscinas. Para o critério da Gravidade, considerou-se que a gravidade da contaminação e, consequentemente, da possível lesão, está intimamente relacionada com a espécie fúngica envolvida. Foram calculadas as médias da contaminação fúngica por cada estabelecimento antes da lavagem e desinfecção, de modo a estabelecer os níveis de Frequência e, em relação à Exposição, foram estabelecidos intervalos para agrupar as horas semanais de trabalho. Dos 124 trabalhadores que participaram no estudo, 58 (46,8%) possuíam lesões visíveis. Nesses 58, as Leveduras foram as mais isoladas (41,4%), seguidas dos Dermatófitos (24,1%) e de Fungos Filamentosos Não Dermatófitos (6,9%). Candida parapsilosis e Rhodotorula sp. foram as Leveduras mais frequentemente isoladas (20,2%); no caso dos Dermatófitos, Trichophyton rubrum foi a espécie mais frequente (55,5%) e, relativamente aos Fungos Filamentosos Não Dermatófitos, Penicillium sp. foi o mais isolado (15,6%), seguido do género Fusarium (12,5%). No que concerne à contaminação fúngica das superfícies, 37 fungos filamentosos foram isolados. Fusarium foi o género mais frequente, antes e depois da lavagem e desinfecção (19,1% - 17,2%). Em relação aos fungos leveduriformes, 12 leveduras diferentes foram identificadas, tendo sido os géneros Cryptococcus (40,6%) e Candida (49,3%) os mais frequentes antes e depois da lavagem e desinfecção, respectivamente. Em relação à contaminação fúngica do ar, foram identificados 25 fungos filamentosos diferentes, em que os 3 géneros mais frequentemente isolados foram Cladosporium (36,6%), Penicillium (19,0%) e Aspergillus (10,2%). Relativamente às leveduras, foi identificado o género xxi Rhodotorula (87,5%) e as espécies Trichosporon mucoides e Cryptococcus unigutulattus (12,5%). Verificou-se associação, ao nível de significância de 5%, entre lesão visível e horas semanais e entre lesão visível e tempo de profissão, comprovando a influência da duração da exposição ao factor de risco (contaminação fúngica do ambiente profissional), para a presença de lesão visível nos trabalhadores expostos (Tinea pedis e onicomicose), ficando demonstrada a relação entre a exposição ao factor de risco em estudo – exposição profissional a fungos – com os efeitos para a saúde. As variáveis ambientais avaliadas (temperatura, humidade relativa e velocidade do ar) não influenciaram a contaminação fúngica do ar e das superfícies, não tendo sido evidenciada nenhuma relação estatisticamente significativa (p>0,05). Contudo, verificou-se influência do número de ocupantes que frequentaram cada um dos estabelecimentos nas médias das unidades formadoras de colónias por metro quadrado nas superfícies antes da lavagem e desinfecção. Não se verificou correlação entre os resultados quantitativos da contaminação fúngica do ar e a das superfícies dos 10 estabelecimentos monitorizados. No entanto, verificaram-se diferenças significativas, ao nível de significância de 10%, entre a contaminação fúngica das superfícies e a contaminação fúngica do ar (p<0,1), tendo-se constatado que apesar de 50% dos valores mais baixos terem sido superiores na contaminação fúngica do ar, a contaminação fúngica das superfícies apresentou-se com maior variabilidade quantitativa. Em relação às diferenças significativas na contaminação fúngica das superfícies nos 10 estabelecimentos entre antes e depois da lavagem e desinfecção, apenas se verificou redução significativa (p<0,05) da contaminação fúngica depois da lavagem e desinfecção nos balneários e vestiários masculinos em relação aos fungos leveduriformes. No estabelecimento seleccionado, verificou-se que a relação entre a contaminação fúngica e a temperatura e humidade relativa não foi significativa (p>0,05) em ambas as estações do ano e também não se constatou influência dos ocupantes nos valores médios das unidades formadoras de colónias por metro quadrado das superfícies antes da lavagem e desinfecção em ambas as estações de ano. Em quase todas as situações em que se verificaram diferenças significativas entre as duas estações do ano, verificou-se um aumento das unidades formadoras de colónias por metro quadrado no Inverno, com excepção do total das unidades formadoras de colónias por metro quadrado antes da lavagem e desinfecção nos balneários e vestiários masculinos em que se verificou aumento no Verão. Constatou-se também que apenas ocorreu redução da xxii contaminação fúngica depois da lavagem e desinfecção nas escadas de acesso no Inverno e nos balneários e vestiários masculinos no Verão. Com a aplicação do método para estabelecer um padrão de exposição profissional a fungos nas superfícies obteve-se, nos 10 estabelecimentos, com Nível de Risco Mínimo 65 locais (54,2%), com Nível de Risco Médio 23 locais (19,2%) e com Nível de Risco Elevado 32 locais (26,6%). Próximo do jacuzzi e junto ao tanque foram os locais com mais classificações de Nível de Risco Elevado. No estabelecimento seleccionado verificou-se que, no Verão, depois da lavagem e desinfecção, ocorreu um maior número de locais classificados no Nível de Risco Elevado e, no Inverno, constatou-se a situação inversa, tendo sido observado maior número de locais com Nível de Risco Elevado antes da lavagem e desinfecção. Junto ao tanque e nas escadas de acesso à zona envolvente ao jacuzzi e tanque foram os locais com mais classificações de Nível de Risco Elevado, no Verão e no Inverno. Foram isolados nas superfícies fungos comuns aos isolados nos trabalhadores. Antes da lavagem e desinfecção, 30,3% dos fungos foram isolados nas superfícies e nos trabalhadores e depois desses procedimentos 45,5% dos fungos foram também isolados comummente. As Leveduras foram as mais isoladas comummente e as que se verificaram mais frequentes antes e depois da lavagem e desinfecção da superfícies e, também, nos resultados das colheitas biológicas realizadas aos trabalhadores, foram o género Rhodotorula e a espécie Candida parapsilosis, permitindo confirmar que a infecção fúngica dos trabalhadores está relacionada com a contaminação fúngica das superfícies. Concluiu-se que é necessária a intervenção em Saúde Ocupacional no âmbito da vigilância ambiental e da vigilância da saúde, com o intuito de diminuir a prevalência das infecções fúngicas. Para a prossecução desse objectivo, sugere-se a implementação de medidas preventivas, nomeadamente: o controlo da contaminação fúngica das superfícies mediante procedimentos de lavagem e desinfecção eficazes, de modo a minimizar a contaminação fúngica das superfícies; a identificação precoce da infecção através da realização de colheitas biológicas periódicas aos trabalhadores, inseridas num protocolo de vigilância da saúde; e, ainda, a sensibilização para a aplicação de medidas de higiene pessoal e o tratamento das patologias. A aplicação do método criado para estabelecer um padrão de exposição profissional a fungos nas superfícies servirá não só para a estimação do risco de infecção fúngica dos trabalhadores de ginásios com piscinas, mas também para facilitar o estabelecimento de valores fúngicos de referência, a implementação de medidas correctivas adequadas e imediatas e, ainda, a prevenção de infecções fúngicas, não só nos ginásios com piscina, mas também noutros contextos profissionais. ------------ SUMMARY - Gyms with swimming pools workers have higher prevalence of fungal injuries, such as Tinea pedis and onychomycosis. This is due to their work intrinsic characteristics, since they have more hours per day of exposure to surfaces fungal contamination. This occurs not only because they attend sites most likely to be contaminated, such as showers, changing rooms and pool surrounding area, but also because some of the activities are done barefoot. Furthermore, synthetic clothing and occluded footwear use, which retain the excessive sweating, promotes fungal development. The aim of this study was to know gymnasiums with swimming pool workers infection and/or injury (Tinea pedis and onychomycosis) risk, and its possible relationship with exposure to workplace fungal contamination (air and surfaces). This study describes environmental and biological variables that influence infection and/or fungal injury in a professional setting and explored possible associations between these variables. Differences in surfaces fungal contamination between the two main seasons (summer and winter), as well between before and after cleaning and disinfection were known. It was developed a study with an cross-sectional perspective, that aimed to describe the biological and environmental phenomena of fungal contamination in a professional environment and explore possible associations between variables; an longitudinal perspective in which were known surfaces fungal contamination seasonal differences; and also with an almost experimental perspective that analyzed surfaces fungal distribution before and after cleaning and disinfection. The cross-sectional perspective comprised 10 gyms with swimming pool sample, and another sample of, at least, 10 professionals in each establishment totalling 124 workers (75 men – 60,48%, and 49 women – 39,52%). Were performed 258 biological samples at workers feet, environmental fungal contamination evaluation from the establishments through 50 air samples and 120 surfaces samples (60 before and 60 after cleaning and disinfection) and conducted their laboratory processing and fungal identification. Were also evaluated environmental variables, such as temperature, relative humidity and air velocity completed 10 observation grids, in order to obtain data about variables that affect occupational exposure to fungal species, and also completed 124 observation grids inherent to biological material collection, in order to know the professionals with injury and other relevant information for laboratory analysis. All 124 workers answered to a questionnaire at the same time that occur biological samples collection, in order to xxv obtain information about some of the individual and professional variables with relevance to this study. In one of the establishments were also studied differences concerning surfaces fungal contamination between before and after cleaning and disinfection, and also between two main seasons (summer and winter). In this setting, there were performed 36 surfaces samples before and 36 surfaces samples after cleaning and disinfection on 6 different week days for 6 sequential weeks in each season, totalling 72 surfaces samples. It was also created and implemented a method to establish a pattern for surfaces fungal occupational exposure, in order to help define semi-quantitative levels estimation to fungal infection risk in gyms with swimming pools workers. For Gravity criterion it was considered that contamination severity and, thus, the possible injury are closely related to implicate fungal species. Was calculated fungal contamination average by each establishment prior cleaning and disinfection, in order to establish Frequency levels. Regarding Exposure, were established weekly hours group intervals spent in professional activity. From the 124 professionals tested, 58 (46,8%) had visible injuries. In the 58 workers, Yeasts were the most isolated (41,4%), followed by Dermatophytes (24,1%) and Other Filamentous Fungi Besides Dermatophytes (6,9%). Candida parapsilosis and Rhodotorula sp. were the most frequently isolated Yeasts (20,2% for each), from Dermatophytes, Trichophyton rubrum was the most frequently isolated species (55,5%) and from Other Filamentous Fungi Besides Dermatophytes, Penicillium sp. was the most frequent (15,6%), followed by Fusarium genera (12,5%). Regarding surfaces fungal contamination, 37 filamentous fungi were isolated. Fusarium genera was the most frequent, before and after cleaning and disinfection (19,1% - 17,2%). Considering yeasts, 12 different yeasts were identified, being Cryptococcus (40,6%) and Candida (49,3%) genera the more frequent before and after cleaning and disinfection, respectively. In relation to air fungal contamination, 25 different filamentous fungi were identified and the 3 most frequently isolated genera were Cladosporium (36,6%), Penicillium (19,0%) and Aspergillus (10,2%). For yeasts, were identified Rhodotorula genera (87,5%), and also the species Trichosporon mucoides and Cryptococcus unigutulattus (12,5%). Was found association with 5% significance level, between visible injury and weekly hours and between visible injury and occupation time, confirming exposure duration influence to risk factor (work environment fungal contamination) for the visible injury presence in exposed workers (Tinea pedis and onychomycosis), being confirmed the relation between the study exposure risk - occupational exposure to fungi - with health effects. xxvi Environmental variables evaluated (temperature, relative humidity and air velocity) did not affect air and surfaces fungal contamination and wasn’t found no statistically significant relation (p>0,05). However, there was evidence that occupant’s number influence surfaces colony forming units mean per square meter before cleaning and disinfection. There was no correlation between quantitative data from air fungal contamination and surfaces fungal contamination from the 10 establishments monitored. However, there were significant differences with 10% significance level, between surfaces and air fungal contamination (p<0,1), and despite 50% of the lowest rates were higher in air fungal contamination, it was found that surfaces fungal contamination had more quantitative variability. Regarding differences from the 10 establishments surfaces fungal contamination, between before and after cleaning and disinfection, there was only a significant reduction (p<0,05) in fungal contamination after cleaning and disinfection in male changing rooms for yeasts. In the selected establishment, it was found that relation between fungal contamination and temperature and relative humidity was not significant (p>0,05) in both seasons, and also there wasn’t no influence observed from occupants in surfaces colony forming units mean per square meters before cleaning and disinfection in both seasons. In almost all situations where significant differences between the two seasons were shown, there was a colony-forming units per square meter increase in winter. There was an exception in total colony forming units per square meter before cleaning and disinfection in male changing room’s exception, where there was an increase in summer. Furthermore, was found that only occur a reduction in fungal contamination after cleaning and disinfection, on access stairs in winter, as well as in male changing rooms in summer. With application from the method to establish pattern for surfaces fungal occupational exposure, it was obtained, in the 10 establishments, 65 sites with Low Risk Level (54,2%), 23 sites with Average Risk Level (19,2%) and 32 sites with High Risk Level (26,6%). Near swimming pool and jacuzzi were the places with more High Risk Level classifications. In the selected establishment, was found that in the summer, after cleaning and disinfection, there were a greater number of sites classified as High Risk Level, and in winter it was found the opposite situation, being noted more places with High Risk Level before cleaning and disinfection. Next to swimming pool and access stairs to swimming pool and jacuzzi were the places with more High Risk Level classifications in Summer and Winter. Were isolated common fungi in surfaces and in workers. Prior to cleaning and disinfection 30,3% of fungi were isolated on surfaces and workers, and after 45,5% of fungi were also xxvii commonly isolated. The Yeasts were the most commonly isolated and the most frequent before and after surfaces cleaning and disinfection, and also in workers biological samples, were Rhodotorula genera and Candida parapsilosis, allowing confirming that workers fungal infection is related with surfaces fungal contamination. It was concluded that Occupational Health intervention it is necessary, in environmental monitoring and health surveillance perspective, in order to reduce fungal infections prevalence. To achieve this objective, preventive measures implementation it’s recommended, including: surfaces fungal contamination control, through effective cleaning and disinfecting in order to minimize surfaces fungal contamination; early infection identification by performing periodic biological sampling from workers, included in a health surveillance protocol; and also personal hygiene and diseases treatment awareness. Application of the created method to establish pattern for surfaces fungal occupational exposure, will be useful not only for estimating workers from gymnasiums with swimming pools fungal infection risk, but also to facilitate fungal reference values stipulation, effective and corrective measures implementation, and also, fungal infections prevention, not only in gymnasiums with swimming pool, but also in other professional settings.----------------- RÉSUMÉ - Les travailleurs des gymnases avec des piscines présentent souvent des infections fongiques, telles que Tinea pedis et aussi des onychomycoses, dues à leur activité professionnel, parce qu’ils restent plus longtemps tout prés des surfaces avec une certaine contamination fongique. Toute cette situation est due non seulement parce qu’ils sont ceux qui fréquentent plus souvent les places plus contaminées: des balnéaires, des vestiaires et des zones autour des piscines, mais aussi ils réalisent des activités aux pieds nus ou avec des chaussures très fermés et encore quelques fois avec des vêtements synthétiques. Tout cela emmène à une grande sudation ce qui aidera au développement fongique. Un objective de ce travaille a été connaître le risque d’infection et/ou présence de lésion (Tinea pedis et des onychomycoses) dans les travailleurs des gymnases avec des piscines et leur éventuel rapport avec l’exposition à la contamination fongique (de l’air et des surfaces) dans leurs locaux de travaille. On a décrit aussi des variables d’environnement et biologiques qui ont une certaine influence dans les infections fongiques dans tout l’environnement professionnel et aussi approfondir des éventuels associations entre ces même variables. On a encore reconnu des différences de la contamination fongique avant et après des lavages et désinfection de ces surfaces. Aussi on a trouvé des différences de contamination en Été et en Hiver. Cet étude a un composante transversale, en visant la description des phénomènes de contamination fongique biologique et de l'environnement dans un environnement professionnel et l’étude des associations possibles entre les variables; une composante longitudinale dans laquelle ils étaient connus comme des variations saisonnières de la contamination fongique des surfaces, et même; un quasi-composante expérimentale, où elle a examiné la répartition des champignons surfaces avant et après le lavage et la désinfection. Dans la composante transversale on été considérés 1 échantillons de 10 gymnases avec des piscines et un autre échantillon de au moins 10 professionnels de chaque établissement dans un total 124 travailleurs (75 hommes - 60,48% et 49 femmes - 39,52%). On a réalisé 258 prélèvements aux pieds des travailleurs et on a effectué en simultané la validation par contamination fongique de l’environnement par 50 prélèvements de l’air et par 120 prélèvements de surfaces (60 avant et 60 après des lavages et des désinfections) et on a effectué leur traitement en laboratoire et l’identification fongique. On a fait aussi l’évaluation des variables de l’environnement, la température, l’humidité relative et la vitesse de l’air. On a remplie 10 tableaux xxix d’observation, avec l’objective d’obtenir des informations sur les variables qu’influenceront l’exposition occupationnel aux souches fongiques, et encore 124 tableaux d’observation liée au prélèvement du matériel biologique, pour réaliser le registre des professionnels avec des lésions et des autres informations pertinentes pour une analyse laboratoire. Tous ces 124 travailleurs ont rempli un questionnaire au même temps que les prélèvements biologiques, afin de connaître quelques variables individuels et professionnels importants pour cet étude. Dans un des établissements on a aussi étudié les différences fongiques des surfaces parmi avant et après les lavages et de la désinfection et encore parmi l’Été et l’Hiver. Dans ce même établissement on a réalisé 36 prélèvements des surfaces avant et 36 après des lavages et de la désinfection, pendant 6 jours différents de la semaine, pendant 6 semaines en chaque saison de l’année, dans un total de 72 prélèvements des surfaces. On a encore crié et appliqué une méthode pour établir un standard d’exposition professionnelle au fungi sur les surfaces, afin de permettre la définition des niveaux semi quantitative d’estimation des risques d’infection fongique des travailleurs des gymnases avec des piscines. Pour le critère de Gravité, il a été considéré que la gravité de la contamination, et donc les possibles dommages, est étroitement liée aux espèces fongiques impliquées. Nous avons calculé la moyenne de la contamination fongique par chaque établissement avant le lavage et la désinfection afin d'établir les niveaux de Fréquence et, par rapport à l'Exposition, ont été crées pour regrouper les intervalles d'heures hebdomadaires consacrées à l'activité professionnelle en question. Sur les 124 travailleurs qui ont participé à l'étude, 58 (46,8%) avaient des lésions visibles. Parmi ces 58, les Levures ont été les plus isolées (41,4%), suivis par des Dermatophytes (24,1%) et des Filamenteux Non Dermatophytes (6,9%). Candida parapsilosis and Rhodotorula sp. ont été les Levures les plus fréquemment isolées (20,2%); dans le cas des Dermatophytes, Trichophyton rubrum est le plus fréquent (55,5%) et pour les Filamenteux Non Dermatophytes, Penicillium sp. a été le plus isolé (15,6%), suivi par Fusarium sp. (12,5%). En ce qui concerne la contamination fongique des surfaces, 37 champignons filamenteux ont été isolés. Le genre Fusarium est le plus fréquent avant et après le lavage et la désinfection (19,1% - 17,2%). Pour la levure, 12 levures différentes ont été identifiées, ayant été Cryptococcus sp. (40,6%) et Candida sp. (49,3%) les plus fréquents avant et après le lavage et la désinfection, respectivement. En ce qui concerne la contamination fongique de l'air, on a identifié 25 différents champignons filamenteux, où les 3 genres les plus fréquemment isolés étaient Cladosporium (36,6%), Penicillium (19,0%) et Aspergillus (10,2%). Pour les levures, il a été identifié le genre xxx Rhodotorula (87,5%) et les espèces Trichosporon mucoides et Cryptococcus unigutulattus (12,5%). On a vérifié une association, au niveau de signification de 5%, entre les lésions visibles et les heures hebdomadaires et entre les lésions visibles et la durée d’occupation, ce qui confirme l'influence de la durée de l'exposition aux facteurs de risque (contamination fongique dans le milieu de travail) pour la présence des lésions visibles chez les travailleurs exposés (Tinea pedis et onychomycose), en démontrant une relation entre l'exposition au facteur de risque dans ces études - l'exposition professionnelle aux champignons - avec les effets sur la santé. Les variables environnementales évalué (température, humidité relative et la vitesse de l'air) ne modifient pas la contamination fongique de l'air et des surfaces; donc, n'a pas été démontré aucune relation statistiquement significative (p>0,05). Cependant, il y a une influence du nombre d'occupants qui ont participé à chacun des établissements en moyenne des unités formant colonie par mètre carré sur la surface avant le lavage et la désinfection. Il n'y avait pas de corrélation entre les résultats quantitatifs de la contamination fongique de l'air et des surfaces des 10 établissements surveillés, cependant il existe des différences importantes, au niveau de signification de 10% entre la contamination fongique des surfaces et de la contamination fongique de l'air (p <0,1), on a constaté que malgré 50% des niveaux les plus bas étaient plus élevés dans la contamination fongique de l'air, la contamination fongique des surfaces présentée une plus grande variabilité quantitativement. En ce qui concerne les différences de la contamination fongique des surfaces dans les 10 établissements entre avant et après le lavage et la désinfection, il y avait seulement une réduction significative (p<0,05) de la contamination fongique après le lavage et la désinfection dans les balnéaires et vestiaires pour les hommes par rapport aux levures. Lors de l'établissement choisi, on a constaté que le rapport entre la contamination fongique et la température et l'humidité relative n'était pas significatif (p>0,05) dans les deux saisons et aussi on n’a pas observé l'influence des occupants en moyenne des unités formant colonie par mètres carrés de surfaces avant le lavage et la désinfection dans les deux saisons de l'année. Dans presque toutes les situations ou on a vérifié des différences significatives entre les deux saisons, il ya eu une augmentation des unités formant des colonies par mètre carré en Hiver, à l'exception du total des unités formant des colonies par mètre carré avant le lavage et désinfection dans les balnéaires et vestiaires des hommes où il y a eu une augmentation en Été. On a également été constaté que seulement a eu une réduction de la contamination des xxxi champignons après la désinfection de l'escalier d'accès en Hiver et dans les balnéaires et vestiaires des hommes en Été. Avec la méthode pour établir standard d’exposition professionnelle au fungi sur les surfaces on a obtenu dans les 10 établissements, avec le Niveau de Risque Faible de 65 places (54,2%), avec le Niveau de Risque Moyen 23 places (19,2%) et 32 places avec le Niveau de Risque Élevé (26,6%). Près du jacuzzi et près de la piscine sont les lieux avec des plus évaluations de Niveau de Risque Élevé. Lors de l'établissement choisi, il a été constaté que, dans l'Été, après le lavage et la désinfection, un plus grand nombre de places évaluées comme présentant un Niveau de Risque Élevé et en Hiver on a constaté la situation inverse avec de nombreux points de Niveau de Risque Élevé avant le lavage et la désinfection. A côté de la piscine et les escaliers ont été les lieux avec plus grands classifications de Niveau de Risque Élevé en Été et en Hiver. On a isolé, chez les travailleurs, des champignons communs aux isolés sur les surfaces. Avant le lavage et la désinfection, 30,3% des champignons ont été isolés sur les travailleurs et sur les surfaces et, après ces procédures, 45,5% des champignons ont été isolés fréquemment. Les levures les plus souvent isolées et les plus fréquentes avant et après le lavage et la désinfection des surfaces, et aussi dans les résultats d'échantillons biologiques prélevés sur les travailleurs, étaient du genre Rhodotorula et les espèces de Candida parapsilosis, ce qui permet confirmer que l'infection fongique des travailleurs est liée à la contamination fongique des surfaces. On a conclu qu’il est nécessaire l'intervention en Santé Occupationnelle sous la surveillance de l'environnement et sous la surveillance de la santé, afin de réduire la prévalence des infections fongiques. Pour atteindre cet objectif, nous suggérons la mise en oeuvre de mesures préventives, y compris: le contrôle de la contamination fongique des surfaces par des méthodes de lavage et de désinfection afin de minimiser la contamination fongique des surfaces, l'identification précoce de l'infection avec des prélèvements biologiques périodiques, notamment un protocole pour la surveillance de la santé, et aussi la conscience du sens de l'hygiène personnelle et le traitement des pathologies. La méthode mise en place pour l’établissement d’un standard d’exposition professionnelle au fungi sur les surfaces, servira à estimer non seulement le risque d'infection fongique des travailleurs dans les gymnases avec des piscines, mais aussi pour faciliter l'établissement de valeurs de référence de champignons, l'application des mesures correctives immédiates et appropriées, et aussi la prévention des infections fongiques, non seulement dans les gymnases avec piscine, mais aussi dans d'autres contextes professionnels.
Resumo:
In this paper we report a eight-year prospective study designed to further characterize incidence, epidemiology, specific syndromes, treatment and prognosis associated with fungal infections in neutropenic patients. During the study period 30 fungal infections were diagnosed in 30 patients among 313 episodes of fever and neutropenia (10%). There were 15 cases of candidiasis, 5 pulmonary aspergillosis, 3 sinusitis by Aspergillus fumigatus, 5 infections by Fusarium sp., one infection by Trichosporon sp., and one infection due to Rhodotorula rubra. Blood cultures were positive in 18 cases (60%). The predisposing factors for fungal infection in multivariate analysis were the presence of central venous catheter (p<0.001), longer duration of profound (<100/mm³) neutropenia (p<0.001), the use of corticosteroids (p<0.001), gram-positive bacteremia (p=0.002) and younger age (p=0.03). In multivariate analysis only recovery of the neutropenia (p<0.001) was associated with good prognosis whereas the diagnosis of infection by Fusarium sp. (p=0.006) was strongly associated with a poor outcome. The death rate was 43%. There was no statistically significant difference in the death rate between patients who did receive (52%) or did not receive (50%) antifungal treatment. Identifying patients at risk, specific syndromes and prognostic factors may help to reduce the high mortality associated with disseminated fungal infections in neutropenic patients.
Resumo:
A clinical trial pilot study, double-blinded, randomized, and controlled with a placebo to assess the effectiveness of oral doxycycline (200 mg, single dose) in preventing leptospirosis after high exposure to potentially contamined water was performed in São Paulo, SP, Brazil. Confirmed cases were defined as those with leptospira IgM antibody and symptoms; asymptomatic cases were those presenting with IgM antibodies but no symptoms; and suspected cases were individuals with symptoms but no IgM antibody. Forty subjects were given doxycycline and 42 were given placebo. In the drug-treated group there were 2 confirmed cases, 11 asymptomatic cases, and 6 suspected cases. In the placebo group there were 5 confirmed, 6 symptomatic, and 5 suspected cases. Even though we found a protective association of doxycycline for confirmed leptospirosis cases (RR = 2.3) and seroconversion only (RR = 2.0), the association was not statistically significant because of the small number of individuals enrolled in this pilot study. We observed that the 22% of the volunteers already had IgM antibodies to leptospirosis at the first sampling. Finally, the attack rate to confirmed, asymptomatic, and suspected cases of Leptospirosis was 8.5%, 22%, and 13%, respectively, in this population.
Resumo:
The intensification of agricultural productivity is an important challenge worldwide. However, environmental stressors can provide challenges to this intensification. The progressive occurrence of the cyanotoxins cylindrospermopsin (CYN) and microcystin-LR (MC-LR) as a potential consequence of eutrophication and climate change is of increasing concern in the agricultural sector because it has been reported that these cyanotoxins exert harmful effects in crop plants. A proteomic-based approach has been shown to be a suitable tool for the detection and identification of the primary responses of organisms exposed to cyanotoxins. The aim of this study was to compare the leaf-proteome profiles of lettuce plants exposed to environmentally relevant concentrations of CYN and a MC-LR/CYN mixture. Lettuce plants were exposed to 1, 10, and 100 lg/l CYN and a MC-LR/CYN mixture for five days. The proteins of lettuce leaves were separated by twodimensional electrophoresis (2-DE), and those that were differentially abundant were then identified by matrix-assisted laser desorption/ionization time of flight-mass spectrometry (MALDI-TOF/TOF MS). The biological functions of the proteins that were most represented in both experiments were photosynthesis and carbon metabolism and stress/defense response. Proteins involved in protein synthesis and signal transduction were also highly observed in the MC-LR/CYN experiment. Although distinct protein abundance patterns were observed in both experiments, the effects appear to be concentration-dependent, and the effects of the mixture were clearly stronger than those of CYN alone. The obtained results highlight the putative tolerance of lettuce to CYN at concentrations up to 100 lg/l. Furthermore, the combination of CYN with MC-LR at low concentrations (1 lg/l) stimulated a significant increase in the fresh weight (fr. wt) of lettuce leaves and at the proteomic level resulted in the increase in abundance of a high number of proteins. In contrast, many proteins exhibited a decrease in abundance or were absent in the gels of the simultaneous exposure to 10 and 100 lg/l MC-LR/CYN. In the latter, also a significant decrease in the fr. wt of lettuce leaves was obtained. These findings provide important insights into the molecular mechanisms of the lettuce response to CYN and MC-LR/CYN and may contribute to the identification of potential protein markers of exposure and proteins that may confer tolerance to CYN and MC-LR/CYN. Furthermore, because lettuce is an important crop worldwide, this study may improve our understanding of the potential impact of these cyanotoxins on its quality traits (e.g., presence of allergenic proteins).
Resumo:
Pentachlorophenol (PCP) bioremediation by the fungal strains amongst the cork- colonising community has not yet been analysed. In this paper, the co- and direct metabolism of PCP by each of the 17 fungal species selected from this community were studied. Using hierarchical data analysis, the isolates were ranked by their PCP bioremediation potential. Fifteen isolates were able to degrade PCP under co-metabolic conditions, and surprisingly Chrysonilia sitophila, Trichoderma longibrachiatum, Mucor plumbeus, Penicillium janczewskii and P. glandicola were able to directly metabolise PCP, leading to its complete depletion from media. PCP degradation intermediates are preliminarily discussed. Data emphasise the signiWcance of these fungi to have an interesting potential to be used in PCP bioremediation processes.
Resumo:
ABSTRACT – Background: According to the Report on Carcinogens, formaldehyde ranks 25th in the overall U.S. chemical production, with more than 5 million tons produced each year. Given its economic importance and widespread use, many people are exposed to formaldehyde environmentally and/or occupationally. Presently, the International Agency for Research on Cancer classifies formaldehyde as carcinogenic to humans (Group 1), based on sufficient evidence in humans and in experimental animals. Manyfold in vitro studies clearly indicated that formaldehyde can induce genotoxic effects in proliferating cultured mammalian cells. Furthermore, some in vivo studies have found changes in epithelial cells and in peripheral blood lymphocytes related to formaldehyde exposure. Methods: A study was carried out in Portugal, using 80 workers occupationally exposed to formaldehyde vapours: 30 workers from formaldehyde and formaldehyde-based resins production factory and 50 from 10 pathology and anatomy laboratories. A control group of 85 non-exposed subjects was considered. Exposure assessment was performed by applying simultaneously two techniques of air monitoring: NIOSH Method 2541 and Photo Ionization Detection equipment with simultaneously video recording. Evaluation of genotoxic effects was performed by application of micronucleus test in exfoliated epithelial cells from buccal mucosa and peripheral blood lymphocytes. Results: Time-weighted average concentrations not exceeded the reference value (0.75 ppm) in the two occupational settings studied. Ceiling concentrations, on the other hand, were higher than reference value (0.3 ppm) in both. The frequency of micronucleus in peripheral blood lymphocytes and in epithelial cells was significantly higher in both exposed groups than in the control group (p < 0.001). Moreover, the frequency of micronucleus in peripheral blood lymphocytes was significantly higher in the laboratories group than in the factory workers (p < 0.05). A moderate positive correlation was found between duration of occupational exposure to formaldehyde (years of exposure) and micronucleus frequency in peripheral blood lymphocytes (r = 0.401; p < 0.001) and in epithelial cells (r = 0.209; p < 0.01). Conclusions: The population studied is exposed to high peak concentrations of formaldehyde with a long-term exposure. These two aspects, cumulatively, can be the cause of the observed genotoxic endpoint effects. The association of these cytogenetic effects with formaldehyde exposure gives important information to risk assessment process and may also be used to assess health risks for exposed worker