933 resultados para Frictional Forces
Resumo:
Mechanisms of bacterial pathogenesis have become an increasingly important subject as pathogens have become increasingly resistant to current antibiotics. The adhesion of microorganisms to the surface of host tissue is often a first step in pathogenesis and is a plausible target for new antiinfective agents. Examination of bacterial adhesion has been difficult both because it is polyvalent and because bacterial adhesins often recognize more than one type of cell-surface molecule. This paper describes an experimental procedure that measures the forces of adhesion resulting from the interaction of uropathogenic Escherichia coli to molecularly well defined models of cellular surfaces. This procedure uses self-assembled monolayers (SAMs) to model the surface of epithelial cells and optical tweezers to manipulate the bacteria. Optical tweezers orient the bacteria relative to the surface and, thus, limit the number of points of attachment (that is, the valency of attachment). Using this combination, it was possible to quantify the force required to break a single interaction between pilus and mannose groups linked to the SAM. These results demonstrate the deconvolution and characterization of complicated events in microbial adhesion in terms of specific molecular interactions. They also suggest that the combination of optical tweezers and appropriately functionalized SAMs is a uniquely synergistic system with which to study polyvalent adhesion of bacteria to biologically relevant surfaces and with which to screen for inhibitors of this adhesion.
Resumo:
Point mutants of three unrelated antifluorescein antibodies were constructed to obtain nine different single-chain Fv fragments, whose on-rates, off-rates, and equilibrium binding affinities were determined in solution. Additionally, activation energies for unbinding were estimated from the temperature dependence of the off-rate in solution. Loading rate-dependent unbinding forces were determined for single molecules by atomic force microscopy, which extrapolated at zero force to a value close to the off-rate measured in solution, without any indication for multiple transition states. The measured unbinding forces of all nine mutants correlated well with the off-rate in solution, but not with the temperature dependence of the reaction, indicating that the same transition state must be crossed in spontaneous and forced unbinding and that the unbinding path under load cannot be too different from the one at zero force. The distance of the transition state from the ground state along the unbinding pathway is directly proportional to the barrier height, regardless of the details of the binding site, which most likely reflects the elasticity of the protein in the unbinding process. Atomic force microscopy thus can be a valuable tool for the characterization of solution properties of protein-ligand systems at the single molecule level, predicting relative off-rates, potentially of great value for combinatorial chemistry and biology.
Resumo:
Photoactivation of caged fluorescent tubulin was used mark the microtubule (MT) lattice and monitor MT behavior in interphase cells. A broadening of the photoactivated region occurred as MTs moved bidirectionally. MT movement was not inhibited when MT assembly was suppressed with nocodazole or Taxol; MT movement was suppressed by inhibition of myosin light chain kinase with ML7 or by a peptide inhibitor. Conversely, MT movement was increased after inhibition of cytoplasmic dynein with the antibody 70.1. In addition, the half-time for MT turnover was decreased in cells treated with ML7. These results demonstrate that myosin II and cytoplasmic dynein contribute to a balance of forces that regulates MT organization, movement, and turnover in interphase cells.
Resumo:
We have determined the effects of tropomodulin (Tmod), talin, vinculin, and alpha-actinin on ligament fibroblast adhesion. The anterior cruciate ligament (ACL), which lacks a functional healing response, and the medial collateral ligament (MCL), a functionally healing ligament, were selected for this study. The micropipette aspiration technique was used to determine the forces needed to separate ACL and MCL cells from a fibronectin-coated surface. Delivery of exogenous tropomodulin, an actin-filament capping protein, into MCL fibroblasts significantly increased adhesion, whereas its monoclonal antibody (mAb) significantly decreased cell adhesiveness. However, for ACL fibroblasts, Tmod significantly reduced adhesion, whereas its mAb had no effect. mAbs to talin, vinculin, and alpha-actinin significantly decreased the adhesion of both ACL and MCL cells with increasing concentrations of antibody, and also reduced stress fiber formation and cell spreading rate as revealed by immunofluorescence microscopy. Disruption of actin filament and microtubule assembly with cytochalasin D and colchicine, respectively, also significantly reduced adhesion in ACL and MCL cells. In conclusion, both ACL and MCL fibroblast adhesion depends on cytoskeletal assembly; however, this dependence differs between ACL and MCL fibroblasts in many ways, especially in the role of Tmod. These results add yet another possible factor in explaining the clinical differences in healing between the ACL and the MCL.
Resumo:
O objetivo principal do estudo é comparar o teste em 3 pontos com braquetes com o teste de resistência ao deslizamento utilizando um novo dispositivo que realiza a mensuração simultânea do coeficiente de atrito, das forças e dos momentos nos braquetes de ancoragem e da força de desativação no braquete desalinhado, exercidos por fios ortodônticos. Os objetivos secundários foram desenvolver o dispositivo e comparar, no teste em 3 pontos: (i) a influência, nas grandezas e no coeficiente de atrito cinético, da variação da simetria nas distâncias inter-braquetes, do tipo de braquete de ancoragem (canino ou 2º pré-molar), do deslocamento (3 ou 5mm) do braquete central, do sentido do desalinhamento (vestibular ou lingual) do braquete central e da marca de fio-braquete; (ii) as 3 formas de cálculo do coeficiente de atrito cinético; (iii) os 10 ciclos, para vestibular ou lingual, para verificar se eles são semelhantes ou não entre si. Foram utilizados braquetes autoligáveis (dentes 13, 14 e 15) e fios 0.014\'\' NiTi e CuNiTi das marcas Aditek e Ormco. O teste de resistência ao deslizamento foi realizado no desalinhamento lingual, nos dois deslocamentos e na configuração simétrica. O teste em 3 pontos com braquetes foi realizado no desalinhamento lingual e vestibular, nos dois deslocamentos e na configuração simétrica e assimétrica. Por meio da ANOVA, foram comparados, entre os dois tipos de teste: (A) as grandezas e o coeficiente de atrito e (B) o coeficiente de atrito gerado apenas no braquete de 2º pré-molar. Utilizando-se do mesmo teste estatístico foram comparados, no teste em 3 pontos com braquetes: (A) na configuração simétrica, algumas grandezas e o coeficiente de atrito advindos da variação da marca de fio-braquete, do deslocamento, do desalinhamento e do tipo de braquete; (B) algumas grandezas e o coeficiente de atrito gerados na configuração simétrica e assimétrica; (C) os valores das 3 formas de cálculo do coeficiente de atrito na configuração simétrica; e (D) algumas grandezas e o coeficiente de atrito encontrados nos 10 ciclos. Resultados: (A) a maioria dos valores das grandezas e do coeficiente de atrito gerados pelos dois tipos de teste foram diferentes estatisticamente; (B) o braquete de 2º pré-molar apresentou valores de coeficiente de atrito diferentes entre os dois tipos de teste; (C) na configuração simétrica, as variáveis foram estatisticamente significantes na maioria dos casos para as grandezas analisadas e para o coeficiente de atrito; (D) houve diferença entre a configuração simétrica e assimétrica; (E) o coeficiente de atrito baseado nas duas normais e na força de atrito se aproximou mais da realidade clínica e foi sensível à variação da geometria da relação fio-braquete; e (F) os 10 ciclos para lingual foram semelhantes entre si em 70% dos casos e os 10 ciclos para vestibular foram diferentes em 57% dos casos. Conclusões: o teste em 3 pontos com braquetes é diferente do teste de resistência ao deslizamento; a variação das configurações geométricas e da marca de fio-braquete pode influenciar nos valores das grandezas e do coeficiente de atrito cinético; os 10 ciclos para lingual foram mais semelhantes entre si que os 10 ciclos para vestibular.
Resumo:
This experimental work aims at probing current-induced forces at the atomic scale. Specifically it addresses predictions in recent work regarding the appearance of run-away modes as a result of a combined effect of the non-conservative wind force and a ‘Berry force’. The systems we consider here are atomic chains of Au and Pt atoms, for which we investigate the distribution of break down voltage values. We observe two distinct modes of breaking for Au atomic chains. The breaking at high voltage appears to behave as expected for regular break down by thermal excitation due to Joule heating. However, there is a low-voltage breaking mode that has characteristics expected for the mechanism of current-induced forces. Although a full comparison would require more detailed information on the individual atomic configurations, the systems we consider are very similar to those considered in recent model calculations and the comparison between experiment and theory is very encouraging for the interpretation we propose.