439 resultados para Flot sanguin oculaire pulsatile
Resumo:
Critical lower limb ischemia is a severe disease. A common approach is infrainguinal bypass. Synthetic vascular prosthesis, are good conduits in high-flow low-resistance conditions but have difficulty in their performance as small diameter vessel grafts. A new approach is the use of native decellularized vascular tissues. Cell-free vessels are expected to have improved biocompatibility when compared to synthetic and are optimal natural 3D matrix templates for driving stem cell growth and tissue assembly in vivo. Decellularization of tissues represent a promising field for regenerative medicine, with the aim to develop a methodology to obtain small-diameter allografts to be used as a natural scaffold suited for in vivo cell growth and pseudo-tissue assembly, eliminating failure caused from immune response activation. Material and methods. Umbilical cord-derived mesenchymal cells isolated from human umbilical cord tissue were expanded in advanced DMEM. Immunofluorescence and molecular characterization revealed a stem cell profile. A non-enzymatic protocol, that associate hypotonic shock and low-concentration ionic detergent, was used to decellularize vessel segments. Cells were seeded cell-free scaffolds using a compound of fibrin and thrombin and incubated in DMEM, after 4 days of static culture they were placed for 2 weeks in a flow-bioreactor, mimicking the cardiovascular pulsatile flow. After dynamic culture, samples were processed for histological, biochemical and ultrastructural analysis. Discussion. Histology showed that the dynamic culture cells initiate to penetrate the extracellular matrix scaffold and to produce components of the ECM, as collagen fibres. Sirius Red staining showed layers of immature collagen type III and ultrastructural analysis revealed 30 nm thick collagen fibres, presumably corresponding to the immature collagen. These data confirm the ability of cord-derived cells to adhere and penetrate a natural decellularized tissue and to start to assembly into new tissue. This achievement makes natural 3D matrix templates prospectively valuable candidates for clinical bypass procedures
Resumo:
La sinergia tra diverse aree scientifiche svolge oggi un ruolo preminente nella risoluzione di problematiche molto complesse: in ambito medico, un massiccio intervento delle scienze fisico-matematiche ha portato, grazie alla ricerca sulle proprietà subatomiche (NMR), sulla funzione elettromeccanica tissutale (pace-makers) e sulla biocompatibilità di materiali innovativi, ad un completo rinnovamento e miglioramento delle terapie tradizionali, delineando nuove strategie terapeutiche. In questo quadro di attiva collaborazione si colloca la ricerca in ambito biomeccanico cardiovascolare che, approfondendo la funzionalità del cuore e dei vasi in condizioni normali e patologiche, propone soluzioni terapeutiche alternative all'approccio farmacologico, impensabili fino a pochi anni fa. Uno di questi ambiti è l'insufficienza cardiaca: al ventricolo incapace di produrre l'energia necessaria alla perfusione ematica viene associato un sistema di pulsazione meccanica che riduce il carico durante l'eiezione ed aumenta la perfusione coronarica in diastole. Tuttavia, benché l'efficacia della contropulsazione intra-aortica sia riconosciuta da decenni, alcune problematiche rimangono irrisolte: l'inapplicabilità su pazienti aritmici, l'eccessiva sollecitazione meccanica in pazienti vasculopatici, la complessità e l'alto costo dell'apparecchiatura. Questo lavoro affronta la validazione e la caratterizzazione di una soluzione terapeutica alternativa, di tipo completamente passivo, il cui effetto non è basato sulla somministrazione di energia meccanica dall'esterno, attraverso la pulsazione, ma sull'adattamento di impedenza biomeccanica tra la sorgente elastica pulsatile (il ventricolo) ed il carico (l'aorta). Per verificare l'ipotesi funzionale è stato realizzato un sistema contrattile che simulasse diversi livelli di insufficienza ventricolare ed un sistema vascolare con resistenza idraulica ed elastanza variabili. Sono stati rilevati i parametri fisiologici (pressioni, flusso, potenza ed efficienza) nelle diverse condizioni di accoppiamento biomeccanico e si sono ripetuti i rilievi inserendo il dispositivo di contropulsazione passiva. La validazione sperimentale ha prodotto risultati coerenti con quanto atteso ed è stata indispensabile per l'ottenimento, da parte del Comitato Etico, dell'autorizzazione per la sperimentazione clinica del sistema in oggetto.
Resumo:
In this study, the effect of time derivatives of flow rate and rotational speed was investigated on the mathematical modeling of a rotary blood pump (RBP). The basic model estimates the pressure head of the pump as a dependent variable using measured flow and speed as predictive variables. Performance of the model was evaluated by adding time derivative terms for flow and speed. First, to create a realistic working condition, the Levitronix CentriMag RBP was implanted in a sheep. All parameters from the model were physically measured and digitally acquired over a wide range of conditions, including pulsatile speed. Second, a statistical analysis of the different variables (flow, speed, and their time derivatives) based on multiple regression analysis was performed to determine the significant variables for pressure head estimation. Finally, different mathematical models were used to show the effect of time derivative terms on the performance of the models. In order to evaluate how well the estimated pressure head using different models fits the measured pressure head, root mean square error and correlation coefficient were used. The results indicate that inclusion of time derivatives of flow and speed can improve model accuracy, but only minimally.
Resumo:
Right axillary artery (RAA) cannulation is increasingly used in cardiac surgery. Little is known about resulting flow patterns in the aorta. Therefore, flow was visualized and analyzed. A mock circulatory circuit was assembled based on a compliant transparent anatomical silicon aortic model. A RAA cannula was connected to a continuous flow rotary blood pump (RBP), pulsatile heart action was provided by a pneumatic ventricular assist device (PVAD). Peripheral vascular resistance, regional flow and vascular compliance were adjusted to obtain physiological flow and pressure waveforms. Colorants were injected automatically for flow visualization. Five flow distributions with a total flow of 4 l/min were tested (%PVAD:%RBP): 100:0, 75:25, 50:50, 25:75, 0:100. Colorant distribution was assessed using quantitative 2D image processing. Continuous flow from the RAA divided in a retrograde and an antegrade portion. Retro- to antegrade flow ratio increased with increasing RAA-flow. At full RBP support flow was stagnant in the ascending aorta. There were distinct flow patterns between the right- and left-sided supra-aortic branches. At full RBP support retrograde flow was demonstrated in the right carotid and right vertebral arteries. Further studies are needed to confirm and evaluate the described flow patterns.
Resumo:
Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.
Resumo:
Recent outstanding clinical advances with new mechanical circulatory systems (MCS) have led to additional strategies in the treatment of end stage heart failure (HF). Heart transplantation (HTx) can be postponed and for certain patients even replaced by smaller implantable left ventricular assist devices (LVAD). Mechanical support of the failing left ventricle enables appropriate hemodynamic stabilisation and recovery of secondary organ failure, often seen in these severely ill patients. These new devices may be of great help to bridge patients until a suitable cardiac allograft is available but are also discussed as definitive treatment for patients who do not qualify for transplantation. Main indications for LVAD implantation are bridge to recovery, bridge to transplantation or destination therapy. LVAD may be an important tool for patients with an expected prolonged period on the waiting list, for instance those with blood group 0 or B, with a body weight over 90 kg and those with potentially reversible secondary organ failure and pulmonary artery hypertension. However, LVAD implantation means an additional heart operation with inherent peri-operative risks and complications during the waiting period. Finally, cardiac transplantation in patients with prior implantation of a LVAD represents a surgical challenge. This review summarises the current knowledge about LVAD and continuous flow devices especially since the latter have been increasingly used worldwide in the most recent years. The review is also based on the institutional experience at Berne University Hospital between 2000 and 2012. Apart from short-term devices (Impella, Cardiac Assist, Deltastream and ECMO) which were used in approximately 150 cases, 85 pulsatile long-term LVAD, RVAD or bi-VAD and 44 non-pulsatile LVAD (mainly HeartMateII and HeartWare) were implanted. After an initial learning curve, one-year mortality dropped to 10.4% in the last 58 patients.
Resumo:
OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.
Resumo:
The traditional surgical training in the operating room (OR) is often complemented by participation in workshops and on simulators. The foundation Vascular International offers basic courses for vascular surgery techniques with training on pulsatile circulation, lifelike anatomical models. The aim of this study was to assess the efficacy of a 2.5-day intensive course on basic skills in vascular surgery.
Resumo:
Purpose: Mismatches between pump output and venous return in a continuous-flow ventricular assist device may elicit episodes of ventricular suction. This research describes a series of in vitro experiments to characterize the operating conditions under which the EVAHEART centrifugal blood pump (Sun Medical Technology Research Corp., Nagano, Japan) can be operated with minimal concern regarding left ventricular (LV) suction. Methods: The pump was interposed into a pneumatically driven pulsatile mock circulatory system (MCS) in the ventricular apex to aorta configuration. Under varying conditions of preload, afterload, and systolic pressure, the speed of the pump was increased step-wise until suction was observed. Identification of suction was based on pump inlet pressure. Results: In the case of reduced LV systolic pressure, reduced preload (=10 mmHg), and afterload (=60 mmHg), suction was observed for speeds =2,200 rpm. However, suction did not occur at any speed (up to a maximum speed of 2,400 rpm) when preload was kept within 10-14 mmHg and afterload =80 mmHg. Although in vitro experiments cannot replace in vivo models, the results indicated that ventricular suction can be avoided if sufficient preload and afterload are maintained. Conclusion: Conditions of hypovolemia and/or hypotension may increase the risk of suction at the highest speeds, irrespective of the native ventricular systolic pressure. However, in vitro guidelines are not directly transferrable to the clinical situation; therefore, patient-specific evaluation is recommended, which can be aided by ultrasonography at various points in the course of support.
Resumo:
BACKGROUND AND PURPOSE: Few data exist about clinical, radiologic findings, clinical outcome, and its predictors in patients with spontaneous vertebral artery dissection (sVAD). METHODS: Clinical characteristics, imaging findings, 3-month outcomes, and its predictors were investigated in consecutive patients with sVAD. RESULTS: One hundred sixty-nine patients with 195 sVAD were identified. Brain ischemia occurred in 131 patients (77%; ischemic stroke, n=114, 67%; transient ischemic attack, n=17, 10%). Three patients with ischemic stroke showed also signs of subarachnoid hemorrhage (SAH); 3 (2%) had SAH without ischemia. The 134 patients with brain ischemia or SAH had head and/or neck pain in 118 (88%) and pulsatile tinnitus in seven (5%) patients. The remaining 35 patients (21%) had isolated head and/or neck pain in 21 (12%) cases, asymptomatic sVAD in 13 (8%), and cervical radiculopathy in one case (1%). Location of sVAD was more often in the pars transversaria (V2; 35%) or atlas loop (V3; 34%) than in the prevertebral (V1; 20%) or intracranial (V4; 11%) segment (P=0.0001). Outcome was favorable (modified Rankin scale score 0 or 1) in 88 (82%) of 107 ischemic stroke patients with follow up. Two (2%) patients died. Low baseline National Institutes of Health Stroke Scale score (P<0.0001) and younger age (P=0.007) were independent predictors of favorable outcome. CONCLUSIONS: sVAD is predominantly located in the pars transversaria (V2) or the atlas loop (V3). Most patients show posterior circulation ischemia. Favorable outcome is observed in most ischemic strokes and independently predicted by low National Institutes of Health Stroke Scale score and younger age.
Resumo:
Acromegaly is usually due to autonomous, excessive secretion of growth hormone from a pituitary adenoma. One would expect growth hormone-releasing factor (GHRH) in these patients to be suppressed. In the available literature referring to acromegaly, immunoreactive GHRH levels were determined in 259 acromegalic patients. When growth hormone was measured simultaneously, no correlation was found between serum growth hormone and plasma GHRH concentrations, irrespective of whether the acromegalic patients were treated or not. A possible explanation for this finding might be the lack of a feedback regulation between plasma growth hormone and GHRH. Also, since growth hormone is secreted in a pulsatile fashion the interpretation of single growth hormone values can be difficult. IGF I, which correlates well with mean growth hormone production, may therefore represent a more valuable criterion for the assessment of activity and GHRH plasma levels in acromegalics. However, no study has yet been performed to elucidate the relationship between GHRH and IGF I in acromegaly. To examine this relationship we measured the concentration of plasma GHRH and IGF I in 18 treated patients with acromegaly (age range 32-64 years median 50.5 years; median follow-up 6.5 years, range 3 months to 33 years). All immunoreactive GHRH levels were within the limits described as normal in the literature (mean +/- SD 22.89 +/- 2.72 pg/ml, range 19-28 pg/ml). The IGFI level was 396.78 +/- 224.26 ng/ml (mean +/- SD, range 71-876 ng/ml; reference ranges, age group 25-39 years: 114-492 ng/ml; 40-54 years: 90-360 ng/ml; > 55 years: 71-290 ng/ml). We found no correlation between IGF I and GHRH concentrations (r = 0.17). We therefore conclude that measuring plasma GHRH is not useful in the evaluation of the activity or therapy of acromegaly but may be helpful in its differential diagnosis since a massive elevation of GHRH is typically associated with the ectopic GHRH syndrome, a rare cause of acromegaly.
Resumo:
Aim of the study was to investigate the possible mechanisms leading to stunted growth and osteoporosis in experimental arthritis. Fourty-two female rats of 7-8 weeks of age were randomly assigned to three groups of 14 animals each: (a) controls; (b) adjuvant-inoculated (AA); and (c) adjuvant-inoculated rats receiving 10 mg cyclosporin A (CsA) orally for 30 days. Biological parameters studied were: hindpaw swelling; vertebral length progression expressed as Delta increments between days 1 and 30 as a parameter of skeletal growth, and estimation of total skeletal mineral content by dual energy X-ray absorptiometry (n=10 each group) on day 30. Endocrine parameters measured were pulsatile release of growth hormone (rGH) on day 30 following jugular cannulation and measurement of insulin-like growth factor (IGF-1) in pooled plasma from rGH profiles. Results can be summarized as follows: Untreated AA rats exhibited local signs of inflammation in comparison with controls (hindpaw diameter 8.1-8.9 mm vs. 5.3-5.6 mm in controls). Treatment with CsA normalized this parameter (4.9-5.6 mm). Vertebral growth was significantly retarded in AA rats in comparison with controls (214+/-32 vs. 473+/-33 microm; p<0.001). Administration of CsA normalized vertebral size increment with a clear tendency to overgrowth (523+/-43 microm, n.s.). There was also a marked reduction in total skeletal mineral content in diseased (AA) rats as compared to controls (5.8+/-0.1 vs. 7.5+/-0.1g [OH-apatite]; p<0.001), and a moderate but significant increment above controls in the group receiving CsA (8.0+/-0.1 vs. 7.5+/-0.1g [OH-appatite]; p<0.04). Integrated rGH profiles exhibited a significant fall in arthritic rats and were completely restored to normal under CsA treatment. A trend toward higher rGH values was observed in the latter group (2908+/-554 in AA vs. 8317+/-1492 ng/ml/240 min in controls; p<0.001, and 10940+/-222 ng/ml/240 min, n.s. in the CsA group). There was a good correlation between skeletal growth and rGH pulsatility (r=0.81; p<0.001). IGF-1 followed a similar pattern (630+/-44 in AA vs. 752+/-30 ng/ml in controls; p<0.04, and 769+/-59 ng/ml in the CsA group, n.s. vs. controls). Thus, a clear tendency to skeletal overgrowth following treatment was observed in agreement with the hormonal data. It can therefore be concluded that, in experimental arthritis, attenuated GH-spiking and reduced circulating IGF-1 appear to be causally related to growth retardation, probably mimicking signs and symptoms observed in juvenile arthritis. Therapy with CsA is followed by normalization of hormonal and biological parameters accompanied by a catch up phenomenon in skeletal growth which is also observed clinically in juvenile arthritis. Generalized osteopenia is a prominent feature seemingly connected with the growth abnormalities as they parallel each other during the evolution of the disease and respond equally to therapy.
Resumo:
STUDY DESIGN: In vitro testing of vertebroplasty techniques including pulsed jet-lavage for fat and marrow removal in human cadaveric lumbar and thoracic vertebrae. OBJECTIVE: To develop jet-lavage techniques for vertebroplasty and investigate their effect on cement distribution, injection forces, and fat embolism. SUMMARY OF BACKGROUND DATA: The main complications of cement vertebroplasty are cement leakage and pulmonary fat embolism, which can have fatal consequences and are difficult to prevent reliably by current vertebroplasty techniques. METHODS: Twenty-four vertebrae (Th8-L04) from 5 osteoporotic cadaver spines were grouped in triplets depending on bone mineral density (BMD). Before polymethylmethacrylate (PMMA) vertebroplasty, a pulsatile jet-lavage for removal of intertrabecular fat and bone marrow was performed in 2 groups with 8 specimens each, performing radial and axial irrigation from the biopsy needles. One hundred mL of Ringer solution were injected through 1 pedicle and regained by low vacuum via the contralateral pedicle. Eight control vertebrae were not irrigated. All specimens underwent standardized PMMA cement augmentation injecting 20% of the vertebral volume. Injection forces, cement distribution, and extravasations were quantified. RESULTS: All irrigation solution could be retrieved with the vacuum applied. A Kruskal-Wallis test revealed significantly higher injection forces of the control group as compared with the irrigated groups (P = 0.021). Dilatation of the syringe at forces above 300 N occurred in 75% of the untreated compared with 12.5% of the lavaged specimens. CT distribution analysis showed more homogenous cement distribution of the cement and significantly less extravasation in the irrigated specimens. CONCLUSION: The developed lavage technique for vertebroplasty showed to be feasible and reproducible. The reduction of injection forces would allow the use of more viscous PMMA cement lowering the risk for cement embolization and results in a safer procedure. The wash-out of bone marrow and the possible reduction of pulmonary fat embolism have to be verified with in vivo models.
Resumo:
BACKGROUND: Spontaneous cervicocephalic artery dissection (sCAD) of more than two cervical arteries is rare. PATIENTS AND METHODS: Vascular and potential sCAD risk factors, triggering events, clinical and neuroimaging findings, and outcome of patients with multiple sCAD were studied. Patients were drawn from prospective hospital-based sCAD registries. RESULTS: Of 740 consecutive patients with sCAD, 11 (1.5%) had three, and one had four (0.1%) sCAD. Eight of these 12 patients were women. One patient had additional dissections of the celiac trunk and hepatic artery. Vascular risk factors included hypertension (n = 1), hypercholesterolaemia (n = 6), current smoking (n = 5) and migraine (n = 6). No patient had a family history of sCAD, fibromuscular dysplasia (FMD) or connective tissue disease. SCAD was preceded by a minor trauma in five and infection in four patients. Clinical manifestations included ischaemic stroke (n = 8), transient ischaemic attack (n = 3), headache (n = 9), neck pain (n = 4), Horner syndrome (n = 5), pulsatile tinnitus (n = 2) and dysgeusia (n = 1). Brain MRI revealed ischaemic infarcts that affected one vessel territory in seven and two territories in two patients. The 3-month outcome was favourable (modified Rankin scale score 0-1) in 10 patients (83%). No new recurrent stroke or sCAD occurred during a mean follow-up of 50 (SD 29) months. CONCLUSION: Multiple sCAD occurred preferentially in women and caused clinical symptoms and signs mainly in one vascular territory. In none of the patients was FMD or any other underlying arteriopathy apparent. The majority of multiple sCAD was preceded by a minor trauma or infection. Clinical outcome was favourable in most patients, and long-term prognosis benign. The data suggest that transient vasculopathy may be a major mechanism for multiple sCAD.
Resumo:
Blood perfusion to the femoral head might be endangered during the surgical approach or the preparation of the femoral head or both in hip resurfacing arthroplasty. The contribution of the intramedullary blood supply to the femoral head in osteoarthritis is questionable. Therefore, the contribution of the extraosseous blood supply to osteoarthritic femoral heads was measured intraoperatively to question if there is measurable blood flow between the epiphysis and metaphysis in osteoarthritic hips in case of extraosseus vessel damage. At defined points during surgery we acquired the epiphyseal and metaphyseal femoral head perfusion by high-energy laser Doppler flowmetry. Complete femoral neck osteotomy sparing the retinacular vessels to simulate intraosseous blood disruption showed unchanged epiphyseal blood flow compared to initial measurement after capsulotomy. The pulsatile signal disappeared after transection of the retinacular vessels. Based on these acute measurements, we conclude intramedullary blood vessels to the femoral head do not provide measurable blood supply to the epiphysis once the medial femoral circumflex artery or the retinacular vessels have been damaged. We recommend the use of a safe surgical approach for hip resurfacing and careful implantation of the femoral component to respect blood supply to the femoral head and neck region in hip resurfacing arthroplasty.