983 resultados para Extraction techniques
Resumo:
There is not a specific test to diagnose Alzheimer`s disease (AD). Its diagnosis should be based upon clinical history, neuropsychological and laboratory tests, neuroimaging and electroencephalography (EEG). Therefore, new approaches are necessary to enable earlier and more accurate diagnosis and to follow treatment results. In this study we used a Machine Learning (ML) technique, named Support Vector Machine (SVM), to search patterns in EEG epochs to differentiate AD patients from controls. As a result, we developed a quantitative EEG (qEEG) processing method for automatic differentiation of patients with AD from normal individuals, as a complement to the diagnosis of probable dementia. We studied EEGs from 19 normal subjects (14 females/5 males, mean age 71.6 years) and 16 probable mild to moderate symptoms AD patients (14 females/2 males, mean age 73.4 years. The results obtained from analysis of EEG epochs were accuracy 79.9% and sensitivity 83.2%. The analysis considering the diagnosis of each individual patient reached 87.0% accuracy and 91.7% sensitivity.
Resumo:
Background/Aims: Cytokines have a significant role in the response to injury following liver transplantation, but the origin and course of such molecules are not completely known. The aim of this study was to evaluate the production and liver metabolism of the inflammatory cytokines interleukin (IL)-1 beta, IL-6, IL-8, interferon (IFN)-Y and tumor necrosis factor (TNF)-alpha in orthotopic liver transplantation (OLT), comparing the conventional and the piggyback methods. Methodology: We performed a study of 30 patients who underwent elective OLT and were randomized for the conventional or piggyback techniques at the beginning of the operation. The amount of cytokines and their hepatic metabolism were calculated based on plasma concentrations and vascular blood flow at 2, 5, 10, 15, 30, 60, 90, and 120 minutes after revascularization. Results: The amount of IL-1 beta in portal blood was higher in patients who underwent surgery using the conventional technique (estimate interest = 63,783.9 +/- 16,586.1 pg/min, versus 11,979.6 +/- 16,585.7 pg/min in the piggyback group, p=0.035). There were no significant differences between the two operative`s methods for IL-6, IL-8, IFN-Y and TNF-alpha production. The hepatic metabolism of cytokines was not different between groups. Although all the curves showed higher amounts of cytokines with the conventional technique, these were not statistically significant. Conclusion: The study shows the similarity between the two techniques concerning the stimuli for the production of inflammatory molecules.
Resumo:
Extraction of intracellular protein from Escherichia coli is traditionally achieved by mechanical disruption. A chemical treatment that destroys the integrity of the bacterial cell wall and could provide an alternative technique is examined in this study. Treatment with a combination of the chelating agent ethylenediaminetetraacetate (EDTA) (greater than 0.3 mM) and the chaotropic agent urea (6 M) is highly effective at releasing protein from uninduced E. coli. The 6 M urea in the presence of 3 mM EDTA can release cytoplasmic protein from both logarithmic-phase and stationary-phase E. coli cells at levels equivalent to mechanical disruption. The concentrations of the two chemical agents were the major variables affecting the maximum levels of protein release. Several minor variables and interactions were also identified. The kinetics of protein release is first order. For 2, 4, and 6 M urea with 3 mM EDTA, the time constant is approximately 2.5 min independent of urea concentration. Kinetics for 3 mM EDTA without urea is considerably slower, with a time constant of 12.3 min. (C) 1997 John Wiley & Sons, Inc.
Resumo:
Capillary C4d deposition has been recognized as a marker of antibody-mediated rejection (AMR). Although the detection of capillary C4d by means of immunofluorescence (IF) in cryostat sections is well established, frozen tissue is not always available, thus limiting the diagnosis of AMR. The aim of the present study was to analyze different techniques for C4d staining and the prevalence of C4d in renal allograft biopsies. Detection of C4d was carried out using IF or immunohistochemistry (IHC) on frozen and paraffin sections of renal allograft biopsies available from the same patients. Biopsies obtained from 20 patients were classified into 3 groups: no rejection, acute rejection, and chronic allograft nephropathy (CAN). The capillary C4d deposition prevalence in frozen-IF, considered the gold standard technique for C4d detection, was 45% (9/20 cases). Compared with frozen-IF, the frozen-IHC technique presented an 85% concordance rate (17/20 cases; r =.70; P <.001; sensitivity = 77.8%; specificity = 90.9%). The paraffin-IF technique showed similar results, with an 80% concordance rate (16/20 cases; r =.64; P <.005; sensitivity = 55.6%; specificity = 100%), whereas C4d detection occurred in only 65% of paraffin-IHC cases (13/20; r =.30; not significant; sensitivity = 66.7%; specificity = 63.6%). No capillary C4d deposition was detected in cases without evidence of rejection. However, 4/7 cases (57%) of acute rejection were C4d positive. In the CAN group, 5111 cases (45%) were C4d positive. In conclusion, these results demonstrated that frozen-IHC and paraffin-IF can be considered alternative techniques to frozen-IF for C4d detection. The paraffin-IHC technique displayed the lowest concordance rate for C4d detection.
Resumo:
Computer modelling has shown that electrical characteristics of individual pixels may be extracted from within multiple-frequency electrical impedance tomography (MFEIT) images formed using a reference data set obtained from a purely resistive, homogeneous medium. In some applications it is desirable to extract the electrical characteristics of individual pixels from images where a purely resistive, homogeneous reference data set is not available. One such application of the technique of MFEIT is to allow the acquisition of in vivo images using reference data sets obtained from a non-homogeneous medium with a reactive component. However, the reactive component of the reference data set introduces difficulties with the extraction of the true electrical characteristics from the image pixels. This study was a preliminary investigation of a technique to extract electrical parameters from multifrequency images when the reference data set has a reactive component. Unlike the situation in which a homogenous, resistive data set is available, it is not possible to obtain the impedance and phase information directly from the image pixel values of the MFEIT images data set, as the phase of the reactive reference is not known. The method reported here to extract the electrical characteristics (the Cole-Cole plot) initially assumes that this phase angle is zero. With this assumption, an impedance spectrum can be directly extracted from the image set. To obtain the true Cole-Cole plot a correction must be applied to account for the inherent rotation of the extracted impedance spectrum about the origin, which is a result of the assumption. This work shows that the angle of rotation associated with the reactive component of the reference data set may be determined using a priori knowledge of the distribution of frequencies of the Cole-Cole plot. Using this angle of rotation, the true Cole-Cole plot can be obtained from the impedance spectrum extracted from the MFEIT image data set. The method was investigated using simulated data, both with and without noise, and also for image data obtained in vitro. The in vitro studies involved 32 logarithmically spaced frequencies from 4 kHz up to 1 MHz and demonstrated that differences between the true characteristics and those of the impedance spectrum were reduced significantly after application of the correction technique. The differences between the extracted parameters and the true values prior to correction were in the range from 16% to 70%. Following application of the correction technique the differences were reduced to less than 5%. The parameters obtained from the Cole-Cole plot may be useful as a characterization of the nature and health of the imaged tissues.
Resumo:
Pattern recognition methods have been successfully applied in several functional neuroimaging studies. These methods can be used to infer cognitive states, so-called brain decoding. Using such approaches, it is possible to predict the mental state of a subject or a stimulus class by analyzing the spatial distribution of neural responses. In addition it is possible to identify the regions of the brain containing the information that underlies the classification. The Support Vector Machine (SVM) is one of the most popular methods used to carry out this type of analysis. The aim of the current study is the evaluation of SVM and Maximum uncertainty Linear Discrimination Analysis (MLDA) in extracting the voxels containing discriminative information for the prediction of mental states. The comparison has been carried out using fMRI data from 41 healthy control subjects who participated in two experiments, one involving visual-auditory stimulation and the other based on bimanual fingertapping sequences. The results suggest that MLDA uses significantly more voxels containing discriminative information (related to different experimental conditions) to classify the data. On the other hand, SVM is more parsimonious and uses less voxels to achieve similar classification accuracies. In conclusion, MLDA is mostly focused on extracting all discriminative information available, while SVM extracts the information which is sufficient for classification. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
INTRODUCTION The management of nonpalpable testicular masses is a challenging task, and coexisting infertility can further complicate the treatment decisions. We present our technique for microsurgical organ-sparing resection of incidental nonpalpable testicular nodules combined with microdissection for testicular sperm extraction and tissue cryopreservation in azoospermic patients. TECHNICAL CONSIDERATIONS Five infertile patients with azoospermia presented with nonpalpable hypoechoic testicular masses that were detected by Ultrasonography and underwent organ-sparing surgery. The testis was delivered through an inguinal incision, and the blood circulation was interrupted with a vascular clamp placed on the spermatic cord. Sludged ice was used to prevent warm ischemia, and a temperature probe was used to control the temperature at 12 degrees-15 degrees C. Real-time reflex ultrasonography was used to locate the tumor, and a stereotaxic hook-shaped needle was inserted under ultrasound guidance. The needle was placed adjacent to the tumor to guide the microsurgical resection. The tunica albuginea was incised over the tumor, which was dissected and removed, along with the adjoining parenchymal tissue. Frozen section studies were performed and, if malignancy was confirmed, biopsies of the tumor cavity margins and remaining parenchyma were obtained to ensure the absence of residual tumor. Microdissection was performed for excision of selected enlarged tubules that were processed and cryopreserved. CONCLUSIONS We present a technique for microsurgical organ-sparing resection of testicular tumor and sperm extraction that can be used in selected infertile patients with azoospermia in whom incidental masses have been diagnosed by ultrasonography. This conservative approach should be especially considered for patients with a solitary testis or bilateral tumors. UROLOGY 73: 887-892, 2009. (C) 2009 Elsevier Inc.
Resumo:
Background: In this study, we analyzed the time course of hemodynamic efficiency and follow-up in Fontan candidates who underwent the bidirectional Glenn procedure for staged intracardiac cavopulmonary connection (ICPC). Methods: Between 1991 and 2008, 52 patients with univentricular heart (mean age, 3.3 years; range, 2-8 years; 27 female patients [51.9%]) underwent ICPC. The cardiac malformations were as follows: tricuspid atresia, 25 cases (48.0%); common ventricle, 16 cases (30.7%); and pulmonary atresia with intact ventricular septum, 11 cases (21.1%). The intracardiac cavopulmonary procedure was indicated for all 52 cases. In 42 patients (80.7%), an intra-atrial lateral tunnel was constructed with a bovine pericardium patch. In the last 10 consecutive cases (19.3%), we performed a modified surgical technique in which we implanted an intra-atrial corrugated bovine pericardium tube sutured around the superior and inferior vena cava ostium. In all cases, a 4-mm fenestration was made to reduce the intratunnel pressure. All 52 patients had previously undergone a Glenn operation. Results: There were 2 hospital deaths (3.8%) and no recorded late deaths. During the follow-up, all patients were medicated with antiplatelet drugs. To evaluate the hemodynamic performance, we used Doppler echocardiography, computed tomography, and magnetic nuclear resonance studies. There were no prosthesis thromboses during this follow-up period. To evaluate cardiac arrhythmias, we conducted a Holter study. The last 10 patients with an intra-atrial conduit (IAC) presented with sinus rhythm and no arrhythmias during the last 4 years. The 50 surviving patients (96.1%) have been followed up for 6 to 204 months; all these patients are free of reoperation. Conclusion: The Glenn operation, which is performed at an early age, prepares the pulmonary bed to receive the ICPC. The midterm results of the intracardiac Fontan procedure seem to be good. The modified surgical procedure (IAC) can be a good alternative technique to the Fontan procedure in suitable patients.
Resumo:
Objective: To determine the effect of semen storage and separation techniques on sperm DNA fragmentation. Design: Controlled clinical study. Setting: An assisted reproductive technology laboratory. Patient(s): Thirty normoozospermic semen samples obtained from patients undergoing infertility evaluation. Intervention(s): One aliquot from each sample was immediately prepared (control) for the sperm chromatin dispersion assay (SCD). Aliquots used to assess storage techniques were treated in the following ways: snap frozen by liquid nitrogen immersion, slow frozen with Tris-yolk buffer and glycerol, kept on ice for 24 hours or maintained at room temperature for 4 and 24 hours. Aliquots used to assess separation techniques were processed by the following methods: washed and centrifuged in media, swim-up from washed sperm pellet, density gradient separation, density gradient followed by swim-up. DNA integrity was then measured by SCD. Main Outcome Measure(s): DNA fragmentation as measured by SCD. Result(s): There was no significant difference in fragmentation among the snap frozen, slow frozen, and wet-ice groups. Compared to other storage methods short-term storage at room temperature did not impact DNA fragmentation yet 24 hours storage significantly increased fragmentation. Swim-up, density gradient and density gradient/swim-up had significantly reduced DNA fragmentation levels compared with washed semen. Postincubation, density gradient/swim-up showed the lowest fragmentation levels. Conclusion(s): The effect of sperm processing methods on DNA fragmentation should be considered when selecting storage or separation techniques for clinical use. (Fertil Steril (R) 2010;94:2626-30. (C) 2010 by American Society for Reproductive Medicine.)
Resumo:
Experience with laparoscopic liver resections has increased in recent years, and so have the number of patients operated on by minimally invasive techniques. Specimen extraction is an important step of laparoscopic liver resection. The size of the specimen, is Usually a limitation for the use Of laparoscopy. The aim of this paper is to describe a new technique combining Pfannenstiel suprapubic incision and obstetric forceps to remove a large specimen from laparoscopic liver resections. The present technique allows an expeditious extraction of intact specimens, even huge ones, through a standard suprapubic Pfannenstiel incision. This technique has additional functional and cosmetic advantages over other techniques of specimen retrieval. We believe that the described technique is feasible, can be easily and rapidly performed, and facilitates laparoscopic liver resection by reducing the technical difficulties for specimen removal and may also be used in other abdominal laparoscopic interventions that deal with large surgical specimens.