967 resultados para Endoscopic Laser-surgery
Resumo:
Purpose: To compare the manifest refractive cylinder (MRC) predictability of myopic astigmatism laser in situ keratomileusis (LASIK) between eyes with low and high ocular residual astigmatism (ORA). Setting: London Vision Clinic, London, United Kingdom. Design: Retrospective case study. Methods: The ORA was considered the vector difference between the MRC and the corneal astigmatism. The index of success (IoS), difference vector ÷ MRC, was analyzed for different groups as follows: stage 1, low ORA (ORA ÷ MRC <1), high ORA (ORA ÷ MRC ≥1); stage 2, low ORA group reduced to match the high ORA group for MRC; stage 3, grouped by ORA magnitude with low ORA (<0.50 diopters [D]), mid ORA (0.50 to 1.24 D), and high ORA (≥1.25 D); stage 4, high ORA group subdivided into low (<0.75 D) and high (≥0.75 D) corneal astigmatism. Results: For stage 1, the mean preoperative MRC and mean IoS were −1.32 D ± 0.65 (SD) (range −0.55 to −3.77 D) and 0.27, respectively, for low ORA and −0.79 ± 0.20 D (range −0.56 to −2.05 D) and 0.37, respectively, for high ORA. For stage 2, the mean IoS increased to 0.32 for low ORA. For stage 3, the mean IoS was 0.28, 0.29, and 0.31 for low ORA, mid ORA, and high ORA, respectively. For stage 4, the mean IoS was 0.20 for high ORA/low corneal astigmatism and 0.35 for high ORA/high corneal astigmatism. Conclusions: The MRC predictability was slightly worse in eyes with high ORA when grouped by the ORA ÷ MRC. Matching for the MRC and grouping by ORA magnitude resulted in similar predictability; however, eyes with high ORA and high corneal astigmatism were less predictable.
Resumo:
PURPOSE: To evaluate in a pilot study the visual, refractive, corneal topographic, and aberrometric changes after wavefront-guided LASIK or photorefractive keratectomy (PRK) using a high-resolution aberrometer to calculate the treatment for aberrated eyes. METHODS: Twenty aberrated eyes of 18 patients undergoing wavefront-guided LASIK or PRK using the VISX STARS4IR excimer laser and the iDesign aberrometer (Abbott Medical Optics, Inc., Santa Ana, CA) were enrolled in this prospective study. Three groups were differentiated: keratoconus post-CXL group including 11 keratoconic eyes (10 patients), post-LASIK group including 5 eyes (5 patients) with previous decentered LASIK treatments, and post-RK group including 4 eyes (3 patients) with previous radial keratotomy. Visual, refractive, contrast sensitivity, corneal topographic, and ocular aberrometric changes were evaluated during a 6-month follow-up. RESULTS: An improvement in uncorrected (UDVA) and corrected visual acuity (CDVA) associated with a reduction in the spherical equivalent was observed in the three groups, but was only statistically significant in the keratoconus post-CXL and post-LASIK groups (P ≤ .04). All eyes gained one or more lines of CDVA after surgery. Improvements in contrast sensitivity were observed in the three groups, but they were only statistically significant in the keratoconus post-CXL and post-LASIK groups (P ≤ .04). Regarding aberrations, a reduction was observed in trefoil aberrations in the keratoconus post-CXL group (P = .05) and significant reductions in higher-order and primary coma aberrations in the post-LASIK group (P = .04). CONCLUSIONS: Wavefront-guided laser enhancements using the evaluated platform seem to be safe and effective to restore the visual function in aberrated eyes.
Resumo:
Purpose: From the experience of a large combined series of transperitoneal. (TP) and retroperitoneal (RP) endoscopic complete and partial nephroureterectornies in children, we present a logical selective endoscopic approach to benign renal pathology. Materials and Methods: During a 5-year period 122 complete nephrectomies and nephroureterectomies (bilateral 2, invisible ectopic 8) and 63 partial nephroureterectomies for duplex (52 upper, 8 lower) or singleton polar disease (xanthogranulomatous pyelonephritis 1, cyst 2) were performed. Of the partial nephrectomies, ureterectomy, bladder repair and lower moiety reimplantation were performed in 8. Patient age ranged from 2.7 months to 14 years (mean 2.9 years). Preoperative weight ranged from 2.7 to 98 kg (mean 12.3). The position of the renal remnant, the presence or absence of a refluxing ureter and the need for ureterectomy were the major determining factors affecting choice of endoscopic approach. Results: A total of 179 (96.7%) procedures were successfully completed endoscopically. The 6 open conversions (3.2%) occurred early in our experience. The operating time reflected the complexity of the excision and lower urinary reconstruction (lateral and posterior RP 25 to 145 minutes [mean 921) TP with ureterocelectomy and bladder neck repair 105 to 355 minutes [mean 153]. Hospital stay for RP and simple TP was 1.5 days (mean 1 to 4) and for complicated TP 2 to 8 days (mean 3.5). Conclusions: We suggest a posterior retroperitoneal approach with isolated renal excision without extended ureterectomy. The lateral retroperitoneal approach allows complete ureterectomy as well as better exposure to horseshoe and pelvic kidneys and, therefore, avoids exposure to intraperitoneal. structures. Finally, the transperitoneal approach is recommended when complete moiety excision with lower urinary reconstruction is anticipated.
Resumo:
Objective: This study aimed to investigate how local pain relief is mediated by laser therapy and how dose affects the relationship. Methods: Inflammation was induced in the hind-paws of Wistar rats. Two groups of rats received 780-nm laser therapy (Spectra-Medics Pty Ltd.) at one of two doses (2.5 and 1 J/cm(2)). One group acted as a control. Scores of nociceptive threshold were recorded using paw pressure and paw thermal threshold measures. Results: A dose of 1 J/cm(2) had no statistically significant effect on antinociceptive responses. A dose of 2.5 J/cm(2) demonstrated a statistically significant effect on paw pressure threshold (p < 0.029) compared to controls. There was no difference in paw thermal threshold responses and paw volumes at either dose. Immunohistochemistry in control animals demonstrated normal beta-endorphin containing lymphocytes in control inflamed paws but no beta-endorphin containing lymphocytes in rats that received laser at 2.5 J/cm(2). Conclusion: The results confirm previous findings that the effect of laser therapy is dose-related. The mechanism of effect may occur via a differentiated pressure-sensitive neural pathway rather than a thermal-sensitive neural pathway. The significance of the immunohistochemistry findings remains unknown.
Resumo:
Study Design. Prospective clinical case series. Objective. To evaluate the clinical outcome of anterior endoscopic instrumention for scoliosis using the SRS-24 questionnaire and to examine how these scores change over a 2-year follow-up period. Summary of Background Data. Anterior endoscopic instrumentation correction has several advantages compared with open procedures. However, the clinical results of this technique using a validated outcome measure have rarely been reported in the literature. Methods. A total of 83 consecutive patients underwent endoscopic anterior instrumentation performed at a single unit. Patients completed the SRS-24 questionnaire before surgery and at 3, 6, 12, and 24 months after surgery. The SRS-24 scores were compared between each of the follow-up intervals. Results. The pain, general self-image, and function from back condition domains improved after surgery (P < 0.05). Activity level significantly improved between 3 and 6 months, and both function domains improved between 6 and 12 months (P < 0.05). None of the domains increased significantly after 1 year. Conclusions. Endoscopic anterior instrumentation for scoliosis significantly improved pain, self-image, and function. The greatest improvement in function occurred between 6 and 12 months after surgery. The SRS-24 scores at 1 year from surgery may provide a good indicator of patient outcome in the long-term.
Resumo:
To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.
Resumo:
Retinal burns of subthreshold intensity created using micropulsed diode laser, which remain clinically invisible, have been shown to be successful in treating macular edema while minimizing the risk of collateral damage to the retina. A study was conducted to determine whether spectral domain optical coherence tomography (SD-OCT) could be used to detect subthreshold retinal burns created using the 532-nm green wavelength laser. A series of retinal burns of gradually decreasing intensity were created in 10 eyes. Retinal burns produced with duration of laser exposure of 0.03 second or less, although clinically invisible, were detectable on the SD-OCT scan as increased retinal reflectivity confined to the outer retinal layers. This series demonstrates the potential of using SD-OCT imaging to verify delivery of subthreshold laser burns.
Surface roughness after excimer laser ablation using a PMMA model:profilometry and effects on vision
Resumo:
PURPOSE: To show that the limited quality of surfaces produced by one model of excimer laser systems can degrade visual performance with a polymethylmethacrylate (PMMA) model. METHODS: A range of lenses of different powers was ablated in PMMA sheets using five DOS-based Nidek EC-5000 laser systems (Nidek Technologies, Gamagori, Japan) from different clinics. Surface quality was objectively assessed using profilometry. Contrast sensitivity and visual acuity were measured through the lenses when their powers were neutralized with suitable spectacle trial lenses. RESULTS: Average surface roughness was found to increase with lens power, roughness values being higher for negative lenses than for positive lenses. Losses in visual contrast sensitivity and acuity measured in two subjects were found to follow a similar pattern. Findings are similar to those previously published with other excimer laser systems. CONCLUSIONS: Levels of surface roughness produced by some laser systems may be sufficient to degrade visual performance under some circumstances.
Resumo:
Purpose: To evaluate lenses produced by excimer laser ablation of poly(methyl methacrylate) (PMMA) plates. Setting: University research laboratory. Methods: Two Nidek EC-5000 scanning-slit excimer laser systems were used to ablate plane-parallel plates of PMMA. The ablated lenses were examined by focimetry, interferometry, and mechanical surface profiling. Results: The spherical optical powers of the lenses matched the expected values, but the cylindrical powers were generally lower than intended. Interferometry revealed marked irregularity in the surface of negative corrections, which often had a positive “island” at their center. Positive corrections were generally smoother. These findings were supported by the results of mechanical profiling. Contrast sensitivity measurements carried out when observing through ablated lenses whose power had been neutralized with a suitable spectacle lens of opposite sign confirmed that the surface irregularities of the ablated lenses markedly reduced contrast sensitivity over a range of spatial frequencies. Conclusion: Improvements in beam delivery systems seem desirable.
Resumo:
For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.
Resumo:
An important field of application of lasers is biomedical optics. Here, they offer great utility for diagnosis, therapy and surgery. For the development of novel methods of laser-based biomedical diagnostics careful study of light propagation in biological tissues is necessary to enhance our understanding of the optical measurements undertaken, increase research and development capacity and the diagnostic reliability of optical technologies. Ultimately, fulfilling these requirements will increase uptake in clinical applications of laser based diagnostics and therapeutics. To address these challenges informative biomarkers relevant to the biological and physiological function or disease state of the organism must be selected. These indicators are the results of the analysis of tissues and cells, such as blood. For non-invasive diagnostics peripheral blood, cells and tissue can potentially provide comprehensive information on the condition of the human organism. A detailed study of the light scattering and absorption characteristics can quickly detect physiological and morphological changes in the cells due to thermal, chemical, antibiotic treatments, etc [1-5]. The selection of a laser source to study the structure of biological particles also benefits from the fact that gross pathological changes are not induced and diagnostics make effective use of the monochromatic directional coherence properties of laser radiation.
Resumo:
Corneal surface laser ablation procedures for the correction of refractive error have enjoyed a resurgence of interest, especially in patients with a possible increased risk of complications after lamellar surgery. Improvements in the understanding of corneal biomechanical changes, the modulation of wound healing, laser technology including ablation profiles and different methods for epithelial removal have widened the scope for surface ablation. This article discusses photorefractive keratectomy, trans-epithelial photorefractive keratectomy, laser-assisted sub-epithelial keratomileusis and epithelial-laser-assisted in situ keratomileusis. © 2010 The Authors. Journal compilation © 2010 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
Objective Patients can experience urinary retention (UR) after Holmium laser enucleation of the prostate (HoLEP) that requires bladder distension during the procedure. The aim of this retrospective study is to identify factors affecting the UR after HoLEP. Materials and Methods 336 patients, which underwent HoLEP for a symptomatic benign prostatic hyperplasia between July 2008 and March 2012, were included in this study. Urethral catheters were routinely removed one or two days after surgery. UR was defined as the need for an indwelling catheter placement following a failure to void after catheter removal. Demographic and clinical parameters were compared between the UR (n = 37) and the non-urinary retention (non-UR; n = 299) groups. Results The mean age of patients was 68.3 (±6.5) years and the mean operative time was 75.3 (±37.4) min. Thirty seven patients (11.0%) experienced a postoperative UR. UR patients voided catheter free an average of 1.9 (±1.7) days after UR. With regard to the causes of UR, 24 (7.1%) and 13 (3.9%) patients experienced a blood clot-related UR and a non-clot related UR respectively. Using multivariate analysis (p<0.05), we found significant differences between the UR and the non-UR groups with regard to a morcellation efficiency (OR 0.701, 95% CI 0.498–0.988) and a bleeding-related complication, such as, a reoperation for bleeding (OR 0.039, 95% CI 0.004–0.383) or a transfusion (OR 0.144, 95% CI 0.027–0.877). Age, history of diabetes, prostate volume, pre-operative post-void residual, bladder contractility index, learning curve, and operative time were not significantly associated with the UR (p>0.05). Conclusions De novo UR after HoLEP was found to be self-limited and it was not related to learning curve, patient age, diabetes, or operative time. Efficient morcellation and careful control of bleeding, which reduces clot formation, decrease the risk of UR after HoLEP.
Resumo:
Purpose: To study the concentrations of diadenosine polyphosphates in the ocular surface after PRK and LASIK. Methods: Sixty-one patients (30 males and 31 females) with ages ranging from 20 to 63 (34.04 ± 9.13 years) were recruited in Balear Institute of Ophthalmology, Palma de Mallorca, Spain. LASIK was performed in 92 eyes of 46 patients and PRK in 25 eyes of 15 patients. Variations in the levels of diadenosine polyphosphate (Ap4A and Ap5A), Schirmer I (Jones test), TBUT, corneal staining together with the Dry Eye Questionnaire to evaluate discomfort and dryness were studied. All tests were performed at the preoperative visit and at 1-day, 2-week, 1-month and 3-month postoperative visits. Results: Ap4A showed a 5 and 3.5 fold increase at the 1-day visit for LASIK and PRK, respectively. LASIK patients continued having higher statistically significant concentrations (p = 0.01) all over the follow-up. Ap5A showed no significant differences at any visit. Tear volume decreased during the 3 months in LASIK. The PRK cases had a normal volume at 1 month. TBUT in LASIK increased at the 1-day visit (p = 0,002) and decreased from the 2 weeks onwards and for the PRK, decreased by a 35% at the 1-day visit and kept reduced for a month. Discomfort only increased at the 1-day visit (p = 0.007). Dryness frequency was similar in all visits. Conclusions: Ap4A levels only are increased in refractive surgery patients during the first day after the surgery. This increasing suggests that Ap4A may help accelerating the healing process.
Resumo:
We report the high-energy flat-top supercontinuum covering the mid-infrared wavelength range of 1.9-2.5 μm as well as electronically tunable femtosecond pulses between 1.98-2.22 μm directly from the thulium-doped fiber laser amplifier. Comparison of experimental results with numerical simulations confirms that both sources employ the same nonlinear optical mechanism - Raman soliton frequency shift occurring inside the Tm-fiber amplifier. To illustrate that, we investigate two versions of the compact diode-pumped SESAM mode-locked femtosecond thulium-doped all-silica-fiber-based laser system providing either broadband supercontinuum or tunable Raman soliton output, depending on the parameters of the system. The first system operates in the Raman soliton regime providing femtosecond pulses tunable between 1.98-2.22 μm. Wide and continuous spectral tunability over 240 nm was realized by changing only the amplifier pump diode current. The second system generates high-energy supercontinuum with the superior spectral flatness of better than 1 dB covering the wavelength range of 1.9-2.5 μm, with the total output energy as high as 0.284 μJ, the average power of 2.1 W at 7.5 MHz repetition rate. We simulate the amplifier operation in the Raman soliton self-frequency shift regime and discuss the role of induced Raman scattering in supercontinuum formation inside the fiber amplifier. We compare this system with a more traditional 1.85-2.53 μm supercontinuum source in the external highly-nonlinear commercial chalcogenide fiber using the Raman soliton MOPA as an excitation source. The reported systems1 can be readily applied to a number of industrial applications in the mid-IR, including sensing, stand-off detection, medical surgery and fine material processing.