494 resultados para Endoprothèse (stent)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: We investigated the impact of arterial injury on neointimal hyperplasia following implantation of drug-eluting stents (DES). Methods and results: A total of 196 patients with 223 segments (sirolimus-eluting stents [SES]: 104, paclitaxel-eluting stents [PES]: 119) underwent intravascular ultrasound eight months after DES implantation. Arterial injury was defined as the balloon-to-artery ratio (BAR). Segments were categorised into two groups: high BAR defined as BAR>1.1 (120 segments), and low BAR defined as BAR ≤1.1 (103 segments). Baseline clinical characteristics were similar for both groups. Although reference vessel diameter was smaller, stent diameter, maximal balloon pressure and balloon diameter were higher in the high BAR compared with the low BAR group. Lumen (7.10±1.91 vs. 6.25±1.69, p=0.001), stent (7.31±1.95 vs. 6.41±1.80, p=0.001), and external elastic membrane (17.1±4.9 vs. 14.8±4.0, p<0.0001) areas (mm2) were higher, but neointimal hyperplasia (0.21±0.36 vs. 0.16±0.48, p=0.42) area (mm2) was similar in the high BAR compared with the low BAR group. Arterial injury as assessed by BAR was not associated with the amount of neointimal hyperplasia (R2=0.003, p=0.40). Conclusions: Arterial injury does not correlate with the amount of neointimal hyperplasia following DES implantation. Conventionally aggressive DES implantation techniques do not adversely affect long-term outcome with respect to restenosis. - See more at: http://www.pcronline.com/eurointervention/30th_issue/79/#sthash.1do4X31G.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We performed a pooled analysis of three trials comparing titanium-nitride-oxide-coated bioactive stents (BAS) with paclitaxel-eluting stents (PES) in 1,774 patients. All patients were followed for 12 months. The primary outcomes of interest were recurrent myocardial infarction (MI), death and target lesion revascularization (TLR). Secondary endpoints were stent thrombosis (ST) and major adverse cardiac events (MACE) including MI, death and TLR. There were 922 patients in the BAS group and 852 in the PES group. BAS significantly reduced the risk of recurrent MI (2.7% vs. 5.6%; risk ratio 0.50, 95% CI 0.31-0.81; p = 0.004) and MACE (8.9% vs. 12.6%; risk ratio 0.71, 95% CI 0.54-0.94; p = 0.02) during the 12 months of follow up. In contrast, the differences between BAS and PES were not statistically significant with respect to TLR (risk ratio 0.98, 95% CI 0.68-1.41), death (risk ratio 0.96, 95% CI 0.61-1.51) and definite ST (risk ratio 0.28, 95% CI 0.05-1.47). In conclusion, the results of this analysis suggest that BAS is effective in reducing TLR and improves clinical outcomes by reducing MI and MACE compared with PES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Drug-drug interaction between statins metabolised by cytochrome P450 3A4 and clopidogrel have been claimed to attenuate the inhibitory effect of clopidogrel. However, published data regarding this drug-drug interaction are controversial. We aimed to determine the effect of fluvastatin and atorvastatin on the inhibitory effect of dual antiplatelet therapy with acetylsalicylic acid (ASA) and clopidogrel. One hundred one patients with symptomatic stable coronary artery disease undergoing percutaneous coronary intervention and drug-eluting stent implantation were enrolled in this prospective randomised study. After an interval of two weeks under dual antiplatelet therapy with ASA and clopidogrel, without any lipid-lowering drug, 87 patients were randomised to receive a treatment with either fluvastatin 80 mg daily or atorvastatin 40 mg daily in addition to the dual antiplatelet therapy for one month. Platelet aggregation was assessed using light transmission aggregometry and whole blood impedance platelet aggregometry prior to randomisation and after one month of receiving assigned statin and dual antiplatelet treatment. Platelet function assessment after one month of statin and dual antiplatelet therapy did not show a significant change in platelet aggregation from 1st to 2nd assessment for either statin group. There was also no difference between atorvastatin and fluvastatin treatment arms. In conclusion, neither atorvastatin 40 mg daily nor fluvastatin 80 mg daily administered in combination with standard dual antiplatelet therapy following coronary drug-eluting stent implantation significantly interfere with the antiaggregatory effect of ASA and clopidogrel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

First-generation drug-eluting stents (DES) with controlled release of sirolimus or paclitaxel from durable polymers compared with bare-metal stents have been consistently shown to reduce the risk of repeat revascularization procedures due to restenosis. The superior efficacy was found across a wide range of patients and lesion subsets and persisted up to 5 years whereas similar outcomes have been observed in terms of death and myocardial infarction. Newer generation DES have been developed with the goal to further improve upon the safety profile of first-generation DES while maintaining efficacy. These platforms include DES with improved and more biocompatible durable polymers, DES using bioabsorbable polymers for drug release, DES with polymer-free drug release, and fully bioabsorbable DES. Newer generation DES with durable polymers such as zotarolimus-eluting or everolimus-eluting XIENCE V stents have been directly compared with first-generation DES. Most recent results of large scale clinical trials are encouraging in terms of similar or increased efficacy while improving safety by reducing the rates of myocardial infarctions and stent thrombosis. DES using biodegradable polymers for drug release represent the next technological modification and preliminary results are favorable and demonstrate similar angiographic and clinical efficacy as first-generation DES, but only longer term follow-up and investigation in larger patient cohorts will determine whether their use is associated with improved long-term safety. Fully bioabsorbable stents represent another innovative approach. Whether this innovative concept will enter into clinical routine remains yet to be determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the differences in terms of curvature and angulation of the treated vessel after the deployment of either a metallic stent or a polymeric scaffold device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm(2) vs. 3.19 ± 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm(2) vs. 14.76 ± 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm(2) vs. 1.21 ± 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm(2) vs. 1.15 ± 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of self-expanding retrievable stents is an emerging and promising treatment strategy for acute stroke treatment. The concept combines the advantages of stent deployment with immediate flow-restoration and of mechanical thrombectomy with definitive thrombus removal. The present study was performed to gain more knowledge about the principle of combined flow restoration and thrombectomy in an established animal model using radiopaque thrombi evaluating efficiency, thrombus-device interaction and possible complications of the first dedicated flow-restoration and mechanical thrombectomy device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to review the results and clinical outcome of patients with surgically treated lesions within the trigone of the lateral ventricle. This is a retrospective case series of 20 (eight male, 12 female) patients with lesions of the trigone of the lateral ventricle operated between 1998 and 2008. All lesions were removed via the transcortical temporal and transcortical parietal route. Surgical complications and outcome were assessed using the modified Rankin Scale (mRS). There were four children and 16 adults with a mean age of 42?±?22 years (min?=?1, max?=?74). Eight (40%) lesions grew within the trigone of the dominant hemisphere. In 17 cases, the lesion was purely intraventricular, and in three cases, a slight paraventricular extension was seen. The mean size was 4.5 cm of maximal diameter. Surgical removal was achieved via the transcortical parietal route in 13 cases (65%) and the transcortical temporal route in seven cases (35%). In all cases, complete resection was possible. According to the mRS, 13 patients improved, five remained the same, and two were lost to follow-up. One patient had an increased visual field deficit postoperatively and new hemiparesis and aphasia, but returned to the preoperative level within a few weeks. In one patient, an acute myocardial infarction occurred due to previous cardiac stent placement and in-stent stenosis. Even large trigonal lesions can be resected with low morbidity using a transcortical approach depending on the peritrigonal extension of the tumor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background—Long-term comparative data of first-generation drug-eluting stents are scarce. We investigated clinical and angiographic outcomes of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) at 5 years as part of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) LATE study. Methods and Results—A total of 1012 patients were randomly assigned to SES or PES. Repeat angiography was completed in 444 of 1012 patients (43.8%) at 5 years. Major adverse cardiac events occurred in 19.7% of SES- and 21.4% of PES-treated patients (hazard ratio, 0.89; 95% confidence interval, 0.68 to 1.17; P=0.39) at 5 years. There were no differences between SES and PES in terms of cardiac death (5.8% versus 5.7%; P=0.35), myocardial infarction (6.6% versus 6.9%; P=0.51), and target lesion revascularization (13.1% versus 15.1%; P=0.29). Between 1 and 5 years, the annual rate of target lesion revascularization was 2.0% (95% confidence interval, 1.4% to 2.6%) for SES and 1.4% (95% confidence interval, 0.9% to 2.0%) for PES. Among patients undergoing paired angiography at 8 months and 5 years, delayed lumen loss amounted to 0.37±0.73 mm for SES and 0.29±0.59 mm for PES (P=0.32). The overall rate of definite stent thrombosis was 4.6% for SES and 4.1% for PES (P=0.74), and very late definite stent thrombosis occurred at an annual rate of 0.65% (95% confidence interval, 0.40% to 0.90%). Conclusions—Long-term follow-up of first-generation drug-eluting stents shows no significant differences in clinical and angiographic outcomes between SES and PES. The continuous increase in late lumen loss in conjunction with the ongoing risk of very late stent thrombosis suggests that vascular healing remains incomplete up to 5 years after implantation of first-generation drug-eluting stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives This study sought to compare the unrestricted use of everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing percutaneous coronary intervention. Background It is unclear whether there are differences in safety and efficacy between EES and SES during long-term follow-up. Methods Using propensity score matching, clinical outcome was compared among 1,342 propensity score–matched pairs of patients treated with EES and SES. The primary outcome was a composite of death, MI, and target vessel revascularization. Results The median follow-up was 1.5 years with a maximum of 3 years. The primary outcome occurred in 14.9% of EES- and 18.0% of SES-treated patients up to 3 years (hazard ratio [HR]: 0.83, 95% confidence interval [CI]: 0.68 to 1.00, p = 0.056). All-cause mortality (6.0% vs. 6.5%, HR: 0.92, 95% CI: 0.68 to 1.25, p = 0.59) was similar, risks of myocardial infarction (MI) (3.3% vs. 5.0%, HR: 0.62, 95% CI: 0.42 to 0.92, p = 0.017), and target vessel revascularization (7.0% vs. 9.6%, HR: 0.75, 95% CI: 0.57 to 0.99, p = 0.039) were lower with EES than SES. Definite stent thrombosis (ST) (HR: 0.30, 95% CI: 0.12 to 0.75, p = 0.01) was less frequent among patients treated with EES. The reduced rate of MI with EES was explained in part by the lower risk of definite ST and the corresponding decrease in events associated with ST (HR: 0.25, 95% CI: 0.08 to 0.75, p = 0.013). Conclusions The unrestricted use of EES appears to be associated with improved clinical long-term outcome compared with SES. Differences in favor of EES are driven in part by a lower risk of MI associated with ST.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Background: Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Methods: Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). Results: At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50–0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). Conclusions: SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thoracic endovascular aortic repair is increasingly becoming the standard treatment of many thoracic aortic pathologies. New reliable and accurate stent grafts are emerging to widen the endovascular treatment options. We report the results of RELAY (Bolton Medical, Barcelona, Spain) in the large RELAY Endovascular Registry for Thoracic Disease (RESTORE) European registry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Angioplasty and stenting of the IA have been reported with high technical and clinical success rates, low complication rates and good mid-term patency rates. Different antegrade or retrograde endovascular catheter-based approaches and combinations with surgical exposure of the CCA are used. The purpose of this study was to determine safety, efficacy and mid-term clinical and radiological outcome of the stent-assisted treatment of atherosclerotic stenotic disease of the IA with special focus on the different technical approaches.