332 resultados para Electrocardiogram
Resumo:
Brugada syndrome (BS) is a genetic disease identified by an abnormal electrocardiogram ( ECG) ( mainly abnormal ECGs associated with right bundle branch block and ST-elevation in right precordial leads). BS can lead to increased risk of sudden cardiac death. Experimental studies on human ventricular myocardium with BS have been limited due to difficulties in obtaining data. Thus, the use of computer simulation is an important alternative. Most previous BS simulations were based on animal heart cell models. However, due to species differences, the use of human heart cell models, especially a model with three-dimensional whole-heart anatomical structure, is needed. In this study, we developed a model of the human ventricular action potential (AP) based on refining the ten Tusscher et al (2004 Am. J. Physiol. Heart Circ. Physiol. 286 H1573 - 89) model to incorporate newly available experimental data of some major ionic currents of human ventricular myocytes. These modified channels include the L-type calcium current (ICaL), fast sodium current (I-Na), transient outward potassium current (I-to), rapidly and slowly delayed rectifier potassium currents (I-Kr and I-Ks) and inward rectifier potassium current (I-Ki). Transmural heterogeneity of APs for epicardial, endocardial and mid-myocardial (M) cells was simulated by varying the maximum conductance of IKs and Ito. The modified AP models were then used to simulate the effects of BS on cellular AP and body surface potentials using a three-dimensional dynamic heart - torso model. Our main findings are as follows. (1) BS has little effect on the AP of endocardial or mid-myocardial cells, but has a large impact on the AP of epicardial cells. (2) A likely region of BS with abnormal cell AP is near the right ventricular outflow track, and the resulting ST-segment elevation is located in the median precordium area. These simulation results are consistent with experimental findings reported in the literature. The model can reproduce a variety of electrophysiological behaviors and provides a good basis for understanding the genesis of abnormal ECG under the condition of BS disease.
Resumo:
Understanding arterial distensibility has shown to be important in the pathogenesis of cardiovascular abnormalities like hypertension. It is also known that arterial pulse wave velocity (PWV) is a measure of the elasticity or stiffness of peripheral arterial blood vessels. However, it generally requires complex instrumentations to have an accurate measurement and not suited for continual monitoring. In this paper, it describes a simple and non-intrusive method to detect the cardiovascular pulse from a human wrist above the radial artery and a fingertip. The main components of this proposed method are a piezoelectric transducer and a photo-plethysmography circuitry. 5 healthy adults (4 male) with age ranging from 25 to 38 years were recruited. The timing consistency of the detected pulsations is first evaluated and compared to that obtained from a commercial electrocardiogram. Furthermore, the derived PWV is then assessed by the predicted values attained from regression equations of two previous similar studies. The results show good correlations (p < 0.05) and similarities for the former and latter respectively. The simplicity and non-invasive nature of the proposed method can be attractive for even younger or badly disturbed patients. Moreover, it can be used for prolonged monitoring for the comfort of the patients.
Resumo:
Pulse transit time (PTT) is a non-invasive measure, defined as time taken for the pulse pressure waves to travel from the R-wave of electrocardiogram to a selected peripheral site. Baseline PTT value is known to be influenced by physiologic variables like heart rate (HR), blood pressure (BP) and arterial compliance (AC). However, few quantitative data are available describing the factors which can influence PTT measurements in a child during breathing. The aim of this study was to investigate the effects of changes in breathing efforts on PTT baseline and fluctuations. Two different inspiratory resistive loading (IRL) devices were used to simulate loaded breathing in order to induce these effects. It is known that HR can influence the normative PTT value however the effect of HR variability (HRV) is not well-studied. Two groups of 3 healthy children ( 0.05) HR changes during all test activities. Results showed that HRV is not the sole contributor to PTT variations and suggest that changes in other physiologic parameters are also equally important. Hence, monitoring PTT measurement can be indicative of these associated changes during tidal or increased breathing efforts in healthy children.
Resumo:
The purpose of this paper is twofold: first, we compute quality-adjusted measures of productivity change for the three most important diagnostic technologies (i.e., the Computerised Tomography Scan, Electrocardiogram and Echocardiogram) in the major Portuguese hospitals. We use the Malmquist–Luenberger index, which allows to measure productivity growth while controlling for the quality of the production. Second, using non-parametric tests, we analyse whether the implementation of the Prospective Payment System may have had a positive impact on the movements of productivity over time. The results show that the PPS has helped hospitals to use these tools more efficiently and to improve their effectiveness.
Autonomic dysfunction in unselected and untreated primary open angle glaucoma patients:A pilot study
Resumo:
Purpose: To investigate the presence of silent cardiac ischaemic episodes and the status of autonomic function in consecutive, newly diagnosed and untreated primary open-angle glaucoma patients. Methods: Twenty-four consecutively diagnosed glaucoma patients and 22 age-matched controls were subjected to ambulatory 24-h blood pressure (BP) and electrocardiogram (ECG) monitoring by using Cardiotens-01 (Meditech Ltd). Based on the ECG recordings, heart rate variability (HRV) frequency domain parameters [low-frequency (LF), high-frequency (HF) and LF/HF ratio] were calculated and analysed in the two study groups. Results: Glaucoma patients demonstrated higher LF and LF/HF values than normal subjects for both the active period (p = 0.020 and 0.029) and the passive period (p = 0.044 and 0.049 respectively). HRV parameters were similar in patients and controls suffering from silent cardiac ischaemia (p > 0.05); however, glaucoma patients with normal ECG demonstrated higher LF and LF/HF values during the active period of the 24-h measurement period than control subjects characterized by the same cardiac activity (p = 0.010 and 0.021 respectively). Conclusion: Independent of a history and/or clinical signs of cardiovascular disease, glaucoma patients exhibit abnormal autonomic function. © 2007 The Authors.
Resumo:
Background - Several antipsychotic agents are known to prolong the QT interval in a dose dependent manner. Corrected QT interval (QTc) exceeding a threshold value of 450 ms may be associated with an increased risk of life threatening arrhythmias. Antipsychotic agents are often given in combination with other psychotropic drugs, such as antidepressants, that may also contribute to QT prolongation. This observational study compares the effects observed on QT interval between antipsychotic monotherapy and psychoactive polytherapy, which included an additional antidepressant or lithium treatment. Method - We examined two groups of hospitalized women with Schizophrenia, Bipolar Disorder and Schizoaffective Disorder in a naturalistic setting. Group 1 was composed of nineteen hospitalized women treated with antipsychotic monotherapy (either haloperidol, olanzapine, risperidone or clozapine) and Group 2 was composed of nineteen hospitalized women treated with an antipsychotic (either haloperidol, olanzapine, risperidone or quetiapine) with an additional antidepressant (citalopram, escitalopram, sertraline, paroxetine, fluvoxamine, mirtazapine, venlafaxine or clomipramine) or lithium. An Electrocardiogram (ECG) was carried out before the beginning of the treatment for both groups and at a second time after four days of therapy at full dosage, when blood was also drawn for determination of serum levels of the antipsychotic. Statistical analysis included repeated measures ANOVA, Fisher Exact Test and Indipendent T Test. Results - Mean QTc intervals significantly increased in Group 2 (24 ± 21 ms) however this was not the case in Group 1 (-1 ± 30 ms) (Repeated measures ANOVA p < 0,01). Furthermore we found a significant difference in the number of patients who exceeded the threshold of borderline QTc interval value (450 ms) between the two groups, with seven patients in Group 2 (38%) compared to one patient in Group 1 (7%) (Fisher Exact Text, p < 0,05). Conclusions - No significant prolongation of the QT interval was found following monotherapy with an antipsychotic agent, while combination of these drugs with antidepressants caused a significant QT prolongation. Careful monitoring of the QT interval is suggested in patients taking a combined treatment of antipsychotic and antidepressant agents.
Resumo:
Mechanical physiological pulsations are movements of a body surface incited by the movements of muscles in organs inside the body. Here we demonstrate the use of long-period grating sensors in the detection of cardio-vascular pulsations (CVP), in particular apex and carotid pulsations. To calibrate the sensors, we use a mechanical tool designed specifically to measure the sensor response to a localized perturbation at different grating curvatures as working points. From the data we infer the amplitude of the CVP. Together with the electrophysiological signals, the CVP signals obtained from the sensors can provide significant information on heart function which is inaccessible to the electrocardiogram. The low cost and easy handling of the fibre sensors increase their prospects to become the sensors of choice for novel diagnostic devices. © 2013 The Royal Swedish Academy of Sciences.
Resumo:
A novel approach of normal ECG recognition based on scale-space signal representation is proposed. The approach utilizes curvature scale-space signal representation used to match visual objects shapes previously and dynamic programming algorithm for matching CSS representations of ECG signals. Extraction and matching processes are fast and experimental results show that the approach is quite robust for preliminary normal ECG recognition.
Resumo:
Summarizing the accumulated experience for a long time in the polyparametric cognitive modeling of different physiological processes (electrocardiogram, electroencephalogram, electroreovasogram and others) and the development on this basis some diagnostics methods give ground for formulating a new methodology of the system analysis in biology. The gist of the methodology consists of parametrization of fractals of electrophysiological processes, matrix description of functional state of an object with a unified set of parameters, construction of the polyparametric cognitive geometric model with artificial intelligence algorithms. The geometry model enables to display the parameter relationships are adequate to requirements of the system approach. The objective character of the elements of the models and high degree of formalization which facilitate the use of the mathematical methods are advantages of these models. At the same time the geometric images are easily interpreted in physiological and clinical terms. The polyparametric modeling is an object oriented tool possessed advances functional facilities and some principal features.
Resumo:
A novel approach of automatic ECG analysis based on scale-scale signal representation is proposed. The approach uses curvature scale-space representation to locate main ECG waveform limits and peaks and may be used to correct results of other ECG analysis techniques or independently. Moreover dynamic matching of ECG CSS representations provides robust preliminary recognition of ECG abnormalities which has been proven by experimental results.
Resumo:
BACKGROUND: It is unclear whether diagnostic protocols based on cardiac markers to identify low-risk chest pain patients suitable for early release from the emergency department can be applied to patients older than 65 years or with traditional cardiac risk factors. METHODS AND RESULTS: In a single-center retrospective study of 231 consecutive patients with high-risk factor burden in which a first cardiac troponin (cTn) level was measured in the emergency department and a second cTn sample was drawn 4 to 14 hours later, we compared the performance of a modified 2-Hour Accelerated Diagnostic Protocol to Assess Patients with Chest Pain Using Contemporary Troponins as the Only Biomarker (ADAPT) rule to a new risk classification scheme that identifies patients as low risk if they have no known coronary artery disease, a nonischemic electrocardiogram, and 2 cTn levels below the assay's limit of detection. Demographic and outcome data were abstracted through chart review. The median age of our population was 64 years, and 75% had Thrombosis In Myocardial Infarction risk score ≥2. Using our risk classification rule, 53 (23%) patients were low risk with a negative predictive value for 30-day cardiac events of 98%. Applying a modified ADAPT rule to our cohort, 18 (8%) patients were identified as low risk with a negative predictive value of 100%. In a sensitivity analysis, the negative predictive value of our risk algorithm did not change when we relied only on undetectable baseline cTn and eliminated the second cTn assessment. CONCLUSIONS: If confirmed in prospective studies, this less-restrictive risk classification strategy could be used to safely identify chest pain patients with more traditional cardiac risk factors for early emergency department release.
Resumo:
This paper is based on the novel use of a very high fidelity decimation filter chain for Electrocardiogram (ECG) signal acquisition and data conversion. The multiplier-free and multi-stage structure of the proposed filters lower the power dissipation while minimizing the circuit area which are crucial design constraints to the wireless noninvasive wearable health monitoring products due to the scarce operational resources in their electronic implementation. The decimation ratio of the presented filter is 128, working in tandem with a 1-bit 3rd order Sigma Delta (ΣΔ) modulator which achieves 0.04 dB passband ripples and -74 dB stopband attenuation. The work reported here investigates the non-linear phase effects of the proposed decimation filters on the ECG signal by carrying out a comparative study after phase correction. It concludes that the enhanced phase linearity is not crucial for ECG acquisition and data conversion applications since the signal distortion of the acquired signal, due to phase non-linearity, is insignificant for both original and phase compensated filters. To the best of the authors’ knowledge, being free of signal distortion is essential as this might lead to misdiagnosis as stated in the state of the art. This article demonstrates that with their minimal power consumption and minimal signal distortion features, the proposed decimation filters can effectively be employed in biosignal data processing units.
Resumo:
A 74-year-old man presented to our Emergency Department with acute dyspnoea. His electrocardiogram showed atrial flutter with 2:1 block and a rate of 150 bpm. Initial investigations revealed a D-dimer level of 6.01 mg/dl. Based on the patient’s complaints and the high D-dimer level, computed tomography pulmonary angiography was immediately performed. This showed no evidence of pulmonary embolism, but there were pneumatic changes in the right upper lung lobe. Antibiotics treatment was started with pipracillin/tazobactam, after which the patient’s condition improved. However, on the third day after admission he developed acute dyspnoea, diaphoresis and cardiopulmonary instability immediately after defecation. To promptly confirm our clinical suspicion of pulmonary embolism, a transthoracic echocardiography was carried out. This demonstrated a worm-like, mobile mass in the right heart. The right ventricle was enlarged, and paradoxical septal motion was present, indicating right ventricular pressure overload. The systolic tricuspid valvular gradient was 56 mmHg. The patient was treated with thrombolysis. His condition was greatly clinically improved after 3 hours. After 10 days of hospitalization, the patient was discharged.
Resumo:
A Miocardiopatia Takotsubo (MT) ocorre maioritariamente em doentes idosos do género feminino, com associação causal a fatores de stress emocional ou físico. O stress poderá provocar elevações nos níveis de catecolaminas e hiperexpressividade do sistema nervoso simpático, resultando num quadro semelhante a stunning miocárdico neurogénico, onde ocorre “balonamento” dos segmentos meso‐apicais do ventrículo esquerdo (VE). Este traduz‐se em alterações da cinética das paredes do VE e é identificado por ecocardiografia ou ventriculografia. A coronariografia, tipicamente, revela ausência de estenose superior a 50%, oclusões do lúmen ou rutura de placa, mas a apresentação clínica na fase aguda é sugestiva de Síndrome Coronário Agudo (SCA) e o eletrocardiograma (ECG) apresenta alterações sugestivas de Enfarte Agudo do Miocárdio (EAM) anterior. Os achados mais comuns são o supradesnivelamento do segmento ST e inversão da onda T nas derivações pré‐cordiais. Alterações de repolarização nas derivações inferiores ou laterais, ausência de alterações eletrocardiográficas, bloqueio de ramo de novo, taquicardia ventricular (TV) ou fibrilhação ventricular (FV) podem ocorrer, ainda que com menor frequência. O supradesnivelamento do segmento ST reverte ao fim de poucos dias, mas persistem ondas T negativas e um prolongamento do intervalo QT com duração que pode ir até quatro meses. Este prolongamento do intervalo QT indicia um maior risco de disritmias ventriculares malignas em doentes com vulnerabilidade por QT longo prévio. Assim, o ECG tem utilidade limitada no diagnóstico da MT, mas permite avaliar a sua evolução e identificar os doentes em risco de desenvolver arritmias malignas
Resumo:
Introduction: Abdominal pain, in etiology sometimes difficult to be defined, is a frequent complaint in childhood. Abdominal epilepsy is a rare cause of abdominal pain. Objectives: In this article, we report on 5 year old girl patient with abdominal epilepsy. Methods: Some investigations (stool investigation, routine blood tests, ultrasonography (USG), electrocardiogram (ECHO) and electrocardiograpy (ECG), holter for 24hr.) were done to understand the origin of these complaints; but no abnormalities were found. Finally an EEG was done during an episode of abdominal pain and it was shown that there were generalized spikes especially precipitated by hyperventilation. The patient did well on valproic acid therapy and EEG was normal 1 month after beginning of the treatment. Discussion: The cause of chronic recurrent paroxymal abdominal pain is difficult for the clinicians to diagnose in childhood. A lot of disease may lead to paroxysmal gastrointestinal symptoms like familial mediterranean fever and porfiria. Abdominal epilepsy is one of the rare but easily treatable cause of abdominal pain. Conclusion: In conclusion, abdominal epilepsy should be suspected in children with recurrent abdominal pain.