959 resultados para ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY(ESI-MSn)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phospholipids are complex and varied biomolecules that are susceptible to lipid peroxidation after attack by free radicals or electrophilic oxidants and can yield a large number of different oxidation products. There are many available methods for detecting phospholipid oxidation products, but also various limitations and problems. Electrospray ionization mass spectrometry allows the simultaneous but specific analysis of multiple species with good sensitivity and has a further advantage that it can be coupled to liquid chromatography for separation of oxidation products. Here, we explain the principles of oxidized phospholipid analysis by electrospray mass spectrometry and describe fragmentation routines for surveying the structural properties of the analytes, in particular precursor ion and neutral loss scanning. These allow targeted detection of phospholipid headgroups and identification of phospholipids containing hydroperoxides and chlorine, as well as the detection of some individual oxidation products by their specific fragmentation patterns. We describe instrument protocols for carrying out these survey routines on a QTrap5500 mass spectrometer and also for interfacing with reverse-phase liquid chromatography. The article highlights critical aspects of the analysis as well as some limitations of the methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Miniaturized analytical devices, such as heated nebulizer (HN) microchips studied in this work, are of increasing interest owing to benefits like faster operation, better performance, and lower cost relative to conventional systems. HN microchips are microfabricated devices that vaporize liquid and mix it with gas. They are used with low liquid flow rates, typically a few µL/min, and have previously been utilized as ion sources for mass spectrometry (MS). Conventional ion sources are seldom feasible at such low flow rates. In this work HN chips were developed further and new applications were introduced. First, a new method for thermal and fluidic characterization of the HN microchips was developed and used to study the chips. Thermal behavior of the chips was also studied by temperature measurements and infrared imaging. An HN chip was applied to the analysis of crude oil – an extremely complex sample – by microchip atmospheric pressure photoionization (APPI) high resolution mass spectrometry. With the chip, the sample flow rate could be reduced significantly without loss of performance and with greatly reduced contamination of the MS instrument. Thanks to its suitability to high temperature, microchip APPI provided efficient vaporization of nonvolatile compounds in crude oil. The first microchip version of sonic spray ionization (SSI) was presented. Ionization was achieved by applying only high (sonic) speed nebulizer gas to an HN microchip. SSI significantly broadens the range of analytes ionizable with the HN chips, from small stable molecules to labile biomolecules. The analytical performance of the microchip SSI source was confirmed to be acceptable. The HN microchips were also used to connect gas chromatography (GC) and capillary liquid chromatography (LC) to MS, using APPI for ionization. Microchip APPI allows efficient ionization of both polar and nonpolar compounds whereas with the most popular electrospray ionization (ESI) only polar and ionic molecules are ionized efficiently. The combination of GC with MS showed that, with HN microchips, GCs can easily be used with MS instruments designed for LC-MS. The presented analytical methods showed good performance. The first integrated LC–HN microchip was developed and presented. In a single microdevice, there were structures for a packed LC column and a heated nebulizer. Nonpolar and polar analytes were efficiently ionized by APPI. Ionization of nonpolar and polar analytes is not possible with previously presented chips for LC–MS since they rely on ESI. Preliminary quantitative performance of the new chip was evaluated and the chip was also demonstrated with optical detection. A new ambient ionization technique for mass spectrometry, desorption atmospheric pressure photoionization (DAPPI), was presented. The DAPPI technique is based on an HN microchip providing desorption of analytes from a surface. Photons from a photoionization lamp ionize the analytes via gas-phase chemical reactions, and the ions are directed into an MS. Rapid analysis of pharmaceuticals from tablets was successfully demonstrated as an application of DAPPI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本论文由四部分组成。第一部分报道了佛手参提取物的化学成分研究,建立了活性成分含量测定的高效液相测定和指纹图谱研究,采用液质联用技术鉴定了主要色谱峰;第二部分报道了丹参及其复方制剂的特征图谱研究;第三部分探讨了两面针生物碱的电喷雾质谱裂解规律,并采用液质联用技术分离鉴定了提取物中的多种生物碱。第四部分概述了液质联用在药物代谢研究中的运用。 第一部分包括第一、第二和第三章。第一章针对佛手参(Gymnadeniaconopsea)块茎的甲醇提取物,采用大孔树脂和反相硅胶柱层析等各种分离方法,共分离鉴定出4 个化合物,通过波谱分析将它们的结构确定为dactylorhin B (1)、loroglossin (2)、dactylorhin A (3)和militarine (4)。这4 个化合物均是首次从佛手参中分离得到的琥珀酸葡萄糖苷类成分。第二章采用高效液相色谱法对西藏、四川、河北、青海和尼泊尔等不同地区产的十个佛手参样品进行腺嘌呤核苷和对羟基苯甲醇的定量分析,结果表明这2 个成份可视为佛手参的特征成分,但也注意到产地不同该2 个特征成分的含量也有所不同。第三章采用标准中药指纹图谱相似度计算软件,以10 个佛手参样品HPLC 图谱的平均值为相似性评价对照模板,对10 个样品进行了相似度评价,并经液质联用分析指认了7 个共有峰,分别为腺嘌呤核苷(1)、对羟基苯甲醇(2)、对羟基苯甲醛(3) 、dactylorhin B(4) 、loroglossin(5)、dactylorhin A(6)和militarine(7)。 第二部分包括第四、第五、第六和第七章。第四章运用电喷雾质谱检测了对照药材和五个不同产地的丹参药材中脂溶性和水溶性成分,系统地探讨了多种成分的电喷雾质谱规律,并以对照药材为标准建立了特征指纹图谱。五个产地的药II材通过与对照药材相对比,采用聚类分析的方法,得到了定性的鉴别与判断。并采用液质联用技术对丹参药材提取液中的化学成份进行分析,推测了九个特征峰,并对六样品的液相色谱图进行了聚类分析。第五章探讨了三七皂苷的电喷雾质谱电离和裂解规律,并采用电喷雾质谱法对三七标准药材,血通片中的皂苷成分进行了分析。第六章运用电喷雾质谱研究复方丹参片提取液的特征图谱,并和单味药材丹参和三七的特征图谱进行了对比研究。并运用HPLC-ESI MSn 分析鉴定了复方丹参片提取液中的化学成分,推测了12 个色谱峰。第七章总结了电喷雾质谱和液质联用技术在丹参药材,三七药材及复方丹参制剂中的运用的优势和局限性。 第三部分(第八章)研究了两面针生物碱中二氢白屈菜红碱(1)、二氢两面针碱(2)、8-酮基二氢白屈菜红碱(3)、8-丙酮基二氢两面针碱(4)、两面针碱(5)、和1,3-二(8-二氢两面针碱)丙酮(6)等六个苯并菲啶型生物碱的电喷雾质谱裂解规律,其中二氢两面针碱和二氢白屈菜红碱,8-丙酮基二氢两面针碱和8-酮基二氢白屈菜红碱是两对二个甲氧基分别在C-9 和C-10,C-10 和C-11 的同分异构体。实验结果表明,在相同的碰撞能下,这类位置异构体的ESI MS2 质谱二级碎片离子的相对峰度存在很大差异,这可以用于区分该类同分异构体,采用液-质联用可以对两面针的总生物碱提取物中的这些同分异构体加于区分。同时在本实验采用的液相色谱条件下,多种生物碱得到较好的分离,通过和对照品的保留时间,紫外吸收光谱及电喷雾质谱图对照,鉴定了11 个主要色谱峰。 第四部分(第九章)对液质联用技术在药物代谢中的运用进行了综述。 This dissertation consisted of four sections. The first two sections elaborated thephytochemical investigation of the rhizomes Gymnadenia conopsea R. Br., methoddevelopment for rapid identifying and qutifying the chemical condtituent of thistibetant medicine, and the chemical fingerprint analysis of rhizomes of G. conopsea,Salviae miltiorrhiza and P. notoginseng. The third section studied the fragmentationmechanism of six alkaloids from Zanthoxylum nitidium and method development forrapid identifying varieties of alkaloids from the extract of this herbal medicine. Thefourth section reviewed HPLC- MS method in drug metabolism studies. The first section consisted of chapters 1, 2, 3. Chapter 1 elaborated the phytochemicalinvestigation of Gymnadenia conopsea R. Br. Four succinate derivative esters wereisolated from the methanol extract of the rhizomes of G. conopsea through repeatedcolumn chromatography on normal and reversed phase silica gel, their structures weredetermined by ESI-MS, 1D and 2D NMR evidence. They were firstly discoveredfrom this species. In chapter 2, a high-performance liquid chromatography.diodearray detection (HPLC-DAD) method has been firstly developed for quantitation oftwo characteristic constituents, adenosine and 4-hydroxybenzyl alcohol, from theextract of rhizomes of G. conopsea. All 10 samples of G. conopsea contained differentamount of adenosine and 4-hydroxybenzyl alcohol. Adenosine and the4-hydroxybenzyl alcohol can be applied in identification and quality control for theroots of G. conopsea. In chapter 3, a high-performance liquid chromatography.diodearray detection.tandem mass spectrometry (HPLC-DAD-MSn) method has been firstly developed for chemical fingerprint analysis of rhizomes of G. conopsea andrapid identification of major compounds in the fingerprints. Comparing the UV andMS spectra with those of authentic compounds, seven main peaks in the fingerprintswere identified as adenosine, 4-hydroxybenzyl alcohol, 4-hydroxybenzyl aldehyde,dactylorhin B, loroglossin, dactylorhin A and militarine. The Computer AidedSimilarity Evaluation System for Chromatographic Fingerprint of TraditionalChinese Medicine (CASES) was employed to evaluate the similarities of 10 samplesof the rhizomes of G. conopsea collected from Sichuan, Qinghai and Hebei provincesand Tibet autonomous region of China, and Nepal. These samples from differentsources had similar chemical fingerprints to each other. The second section consisted of chapters 4, 5, 6 and 7. In chapter 4,both thecharacteristic spectra of liposoluble tanshinones and aqueous-soluble salvianolic acidswere established by the electrospray ionization mass spectrometry (ESI MS)technique and the differences between standard and crude rhizomes of Salviaemiltiorrhiza Bge. from 5 sources were analyzed. The law of electrospray ion trap mass(ESI ITMS) of typical tanshinones and salvianolic acids is studied.The analysis of the chemical constituent of rhizomes of Salviae miltiorrhiza Bge. byliquid chromatography coupled with mass spectrum (LC/MS) technique wasestablished,and the distances among standard herb and crude herb from 5 sourceswere calculated by clustering analysis. According the DAD spectra and MS2 data,9tanshinones could be speculated. In chapter 5, the character spectra of total saponinsin P. notoginseng extracts were established by ESI ITMS and selective ion monitoring(SIM) technology. The law of notoginsenosides by ESI MS2 was studied. In chapter 6,the characteristic spectra of Compound Danshen Tablet established and compared byESI-MS and HPLC/DAD/MS, 6 known tanshinones and 3 saponins were speculated.In chapter 7, the advantage and disadvantage of the strategy, using the ESI ITMS andLC/MS techniques for study of characteristic spetra of danshen and Compound Danshen Tablet, were summerized. The third section (chapter 8) studied the fragmentation mechanism of six alkaloids,dihydronitidine, dihydrochelerythrine, 8-acetonyl dihydronitidine,8-acetonyldrochelerythrine, nitidine and 1,3-bis (8-dihydronitidinyl)-acetone, by ESIMSn. Tandem mass spectrometry experiments indicated that different substitutionsites of the methoxyl groups at C-9 and C-10 or at C-10 and C-11 determined thedifferent abundances of the MS2 fragmentation ions using the same collision energy.According to the different abundances of MS2 product ions, positional isomericbenzo[c] phenanthridine alkaloids can be differentiated. Moreover, ten constituents inthe crude alkaloids extract from the roots of Zanthoxylum nitidium were rapidlyidentified by high-performance liquid chromatography coupled with tandem massspectrometry (HPLC-MSn), through comparing the retention times and ESI MSn spectra with the authentic standards. The fourth section (chapter 9) is a review on HPLC-MS method development in drug metabolism studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid method was developed to analyze the extract of the Gentiana scabra Bge. by using high performance liquid chromatograghy-electrospray ionization multi-stage tandem mass spectrometry (HPLC-ESI-MSn). 5 compounds in Gentiana scabra Bge. are identified in the positive and negative mode. The research results demonstrate that the HPLC-ESI-MSn can quickly identified the components in Gentiana scabra Bge. . It also can provide the information of the relative molecular mass and chemical structure of the compounds in the extract of the Gentiana scabra Bge. .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The composition of a dynamic mixture of similar 2,2'-bipyridine complexes of iron(II) bearing either an amide (5-benzylamido-2,2'-bipyridine and 5-(2-methoxyethane)amido-2,2'-bipyridine) or an ester (2,2'-bipyridine-5-carboxylic acid benzylester and 2,2'-bipyridine-5-carboxylic acid 2-methoxyethane ester) side chain have been evaluated by electrospray mass spectroscopy in acetonitrile. The time taken for the complexes to come to equilibrium appears to be dependent on the counteranion, with chloride causing a rapid redistribution of two preformed heteroleptic complexes (of the order of 1 hour), whereas the time it takes in the presence of tetrafluoroborate salts is in excess of 24^^h. Similarly the final distribution of products is dependent on the anion present, with the presence of chloride, and to a lesser extent bromide, preferring three amide-functionalized ligands, and a slight preference for an appended benzyl over a methoxyethyl group. Furthermore, for the first time, this study shows that the distribution of a dynamic library of metal complexes monitored by ESI-MS can adapt following the introduction of a different anion, in this case tetrabutylammonium chloride to give the most favoured heteroleptic complex despite the increasing ionic strength of the solution. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microsomal glutathione transferase-1 (MGST1) is a membrane-bound enzyme involved in the detoxification of xenobiotics and the protection of cells against oxidative stress. The proposed active form of the enzyme is a noncovalently associated homotrimer that binds one substrate glutathione molecule/trimer. In this study, this complex has been directly observed by electrospray mass spectrometry analysis of active rat liver MGST1 reconstituted in a minimum amount of detergent. The measured mass of the homotrimer is 53 kDa, allowing for the mass of three MGST molecules in complex with one glutathione molecule. Collision-induced dissociation of the trimer complex resulted in the formation of monomer and homodimer ion species. Two distinct species of homodimer were observed, one unliganded and one identified as a homodimer.glutathione complex. Activation of the enzyme by N-ethylmaleimide through modification of Cys(49) (Svensson, R., Rinaldi, R., Swedmark, S., and Morgenstern, R. (2000) Biochemistry 39, 15144-15149) was monitored by the observation of an appropriate increase in mass in both the denatured monomeric and native trimeric forms of MGST1. Together, the data correspond well with the proposed functional organization of MGST1. These results also represent the first example of direct electrospray mass spectrometry analysis of a detergent-solubilized multimeric membrane protein complex in its native state.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amazonian oils and fats display unique triacylglycerol (TAG) profiles and, because of their economic importance as renewable raw materials and use by the cosmetic and food industries, are often subject to adulteration and forgery. Representative samples of these oils (andiroba, Brazil nut, buriti, and passion fruit) and fats (cupuacu, murumuru, and ucuba) were characterized without pre-separation or derivatization via dry (solvent-free) matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Characteristic profiles of TAG were obtained for each oil and tat. Dry MALDI-TOF MS provides typification and direct and detailed information, via TAG profiles, of their variable combinations of fatty acids. A database from spectra could be developed and may be used for their fast and reliable typification, application screening, and quality control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A general mass spectrometry technique for the characterization of alkanethiol-modified surfaces is presented. Alkanethiol self-assembled onto a gold surface (in this case, peptides were attached to the gold surface via a thiolate bond) was reductively desorbed in 0.05 M KOH in the presence of octadecyl-derivatized silica gel. The peptide adsorbed onto the silica gel, whereupon it could be filtered, washed to remove any salts, and then eluted using a mixture of 4:1 v/v methanol/water. The eluant containing the peptide was injected into a Fourier transform ion-cyclotron resonance mass spectrometer (FTICR/MS) via electrospray ionization. The spectrum showed no fragmentation of the peptide, demonstrating the gentleness of the technique. This simple procedure is not limited to FTICR/MS and could be adapted to other mass spectrometers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The enzyme 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) catalyzes the reaction between shikimate 3-phosphate and phosphoenolpyruvate to form 5-enolpyruvylshikimate 3-phosphate, an intermediate in the shikimate pathway, which leads to the biosynthesis of aromatic amino acids. EPSPS exists in an open conformation in the absence of substrates and/or inhibitors and in a closed conformation when bound to the substrate and/or inhibitor. In the present report, the H/D exchange properties of EPSPS from Mycobacterium tuberculosis (Mt) were investigated for both enzyme conformations using ESI mass spectrometry and circular dichroism (CD). When the conformational changes identified by H/D exchanges were mapped on the 3-D structure, it was observed that the apoenzyme underwent extensive conformational changes due to glyphosate complexation, characterized by an increase in the content of alpha-helices from 40% to 57%, while the beta-sheet content decreased from 30% to 23%. These results indicate that the enzyme underwent a series of rearrangements of its secondary structure that were accompanied by a large decrease in solvent access to many different regions of the protein. This was attributed to the compaction of 71% of alpha-helices and 57% of beta-sheets as a consequence of glyphosate binding to the enzyme. Apparently, MtEPSPS undergoes a series of inhibitor-induced conformational changes, which seem to have caused synergistic effects in preventing solvent access to the core of molecule, especially in the cleft region. This may be part of the mechanism of inhibition of the enzyme, which is required to prevent the hydration of the substrate binding site and also to induce the cleft closure to avoid entrance of the substrates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of salts, detergents and chaotropic agents on mass spectrometric analysis are relatively well understood, mainly due to their actions decreasing the performance of ESI interface in mass spectrometric analysis. However, there are few studies in the literature characterizing the effect of protein stabilization by glycerol, followed in some circumstances by the suppression of protein signal when ESI interface is used. The aim of the present research was to investigate in details the mass spectrometric behavior of some proteins in presence of high levels of glycerol during ESI-MS analysis. Thus, horse heart myoglobin and chicken ovalbumin were used as standard proteins. It was demonstrated that the presence of 1% (v/v) glycerol suppressed the signal of these proteins during the ESI-MS analysis, even when the sample nozzle potential was scanned from 28 to 80 V. However, when the glycerol concentration was decreased to 0.5% (v/v) and the sample cone voltage adjusted to 50 V, a perfect envelope of peaks was observed, allowing the spectrum deconvolution and the molecular mass determination with mass accuracy lower than 0.01% in each situation. A molecular explanation for this suppressive effect and for the analytical overcoming of this difficult is proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)