969 resultados para Dosimeter glasses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

At a party of a sports club, an argument started between two groups of young men, in the course of which one of the persons involved threw a beer glass hitting a young man of the other group, who collapsed with a profusely bleeding wound. Although resuscitation measures were initiated immediately, the victim died at the scene due to exsanguination from the completely severed left external carotid artery in combination with the aspiration of blood. Tests with drinking glasses thrown at a skull-neck model suggested that an undamaged beer glass thrown at the head of the victim could not cause the fatal injuries on the neck because of its splintering behaviour. In fact, it seemed that the beer glass had been damaged prior to throwing it and that its sharp edges perforated the skin on hitting the neck.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Narcissists’ perception of others is marked by a negative bias in the service of their own self-enhancement. The aim of this study was to determine whether narcissists’ negative bias extends to the perception of romantic partners too. In addition, we explored whether partners of narcissists succumb to specific perception biases as well. During 14 days, 86 couples completed measures of support given to and received from their partners. The results indicated that both male and female narcissists were more accurate in detecting negative support (e.g., blaming the partner for his or her problems) received from their partners, while female narcissists only were less accurate in perceiving altruistic support motives (e.g., truly enjoying to help the partner) of their male partner. Moreover, narcissists as well as their partners displayed a negative bias by underestimating the amount of altruistic support motives reported by each of them. On the other hand, partners of narcissists were positively biased as well and underestimated the negative support given by the narcissists. Results are discussed in relation to the self-regulatory goals of narcissists and of their partners and with respect to the possible impact of their accuracy and biases on the couple wellbeing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could serve a dual function as a fiducial marker for image guided radiation therapy (IGRT) treatment if it could be modified to be visible on x-rays. In this study, modifications to the MOSFET dosimeter were made to increase its visibility for IGRT treatment. To test whether the modifications hindered the dosimeter’s ability to accurately measure and transmit dose information, the energy dependence, angular dependence and wireless read range of the modified dosimeter were measured and compared to unmodified dosimeters. It was found that the modified dosimeter performed as well as the unmodified dosimeter while also being suitable for use as a fiducial marker for IGRT treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^