889 resultados para Digital Forensics, Forensic Computing, Forensic Science
Resumo:
Here we report the case of a 70-year-old woman who committed suicide by cyanide poisoning. During resuscitation cares, she underwent an antidote treatment by hydroxocobalamin. Postmortem investigations showed marked bright pink discolouration of organs and fluids, and a lethal cyanide blood concentration of 43 mg/L was detected by toxicological investigation. Discolouration of hypostasis and organs has widely been studied in forensic literature. In our case, we interpreted the unusual pink coloration as the result of the presence of hydroxocobalamin. This substance is a known antidote against cyanide poisoning, indicated because of its efficiency and poor adverse effects. However, its main drawback is to interfere with measurements of many routine biochemical parameters. We have tested the potential influence of this molecule in some routine postmortem investigations. The results are discussed.
Resumo:
β-hydroxybutyrate concentrations were determined in blood and synovial fluid in a series of medico-legal cases including hypothermia fatalities, individuals found dead in a cold environment and non-hypothermia cases with various, non-traumatic causes of death. Hypothermia was considered to be the cause of death according to circumstantial elements indicating exposure to cold, autopsy findings, biochemical investigation results and exclusion of other causes of death. The intention of this study was to characterize β-hydroxybutyrate distribution in synovial fluid and assess its usefulness for the postmortem diagnosis of antemortem abnormalities in blood β-hydroxybutyrate levels. Unenhanced CT scans, autopsies, histology, neuropathology, toxicology, and biochemistry were systematically performed. Within the limited number of subjects included in the study, the results indicate that abnormalities in antemortem β-hydroxybutyrate blood levels, as may be observed in hypothermia fatalities, are reflected in postmortem synovial fluid values. These preliminary findings notwithstanding, synovial fluid analysis to determine β-hydroxybutyrate is unlikely to be generally applied due to the more invasive collection technique it requires and could be limited to special cases in which biological fluids systematically collected upon autopsy are unavailable.
Resumo:
The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces.
Resumo:
Unlike the evaluation of single items of scientific evidence, the formal study and analysis of the jointevaluation of several distinct items of forensic evidence has to date received some punctual, ratherthan systematic, attention. Questions about the (i) relationships among a set of (usually unobservable)propositions and a set of (observable) items of scientific evidence, (ii) the joint probative valueof a collection of distinct items of evidence as well as (iii) the contribution of each individual itemwithin a given group of pieces of evidence still represent fundamental areas of research. To somedegree, this is remarkable since both, forensic science theory and practice, yet many daily inferencetasks, require the consideration of multiple items if not masses of evidence. A recurrent and particularcomplication that arises in such settings is that the application of probability theory, i.e. the referencemethod for reasoning under uncertainty, becomes increasingly demanding. The present paper takesthis as a starting point and discusses graphical probability models, i.e. Bayesian networks, as frameworkwithin which the joint evaluation of scientific evidence can be approached in some viable way.Based on a review of existing main contributions in this area, the article here aims at presentinginstances of real case studies from the author's institution in order to point out the usefulness andcapacities of Bayesian networks for the probabilistic assessment of the probative value of multipleand interrelated items of evidence. A main emphasis is placed on underlying general patterns of inference,their representation as well as their graphical probabilistic analysis. Attention is also drawnto inferential interactions, such as redundancy, synergy and directional change. These distinguish thejoint evaluation of evidence from assessments of isolated items of evidence. Together, these topicspresent aspects of interest to both, domain experts and recipients of expert information, because theyhave bearing on how multiple items of evidence are meaningfully and appropriately set into context.
Resumo:
Recent ink dating methods focused mainly on changes in solvent amounts occurring over time. A promising method was developed at the Landeskriminalamt of Munich using thermal desorption (TD) followed by gas chromatography / mass spectrometry (GC/MS) analysis. Sequential extractions of the phenoxyethanol present in ballpoint pen ink entries were carried out at two different temperatures. This method is applied in forensic practice and is currently implemented in several laboratories participating to the InCID group (International Collaboration on Ink Dating). However, harmonization of the method between the laboratories proved to be a particularly sensitive and time consuming task. The main aim of this work was therefore to implement the TD-GC/MS method at the Bundeskriminalamt (Wiesbaden, Germany) in order to evaluate if results were comparable to those obtained in Munich. At first validation criteria such as limits of reliable measurements, linearity and repeatability were determined. Samples were prepared in three different laboratories using the same inks and analyzed using two TDS-GC/MS instruments (one in Munich and one in Wiesbaden). The inter- and intra-laboratory variability of the ageing parameter was determined and ageing curves were compared. While inks stored in similar conditions yielded comparable ageing curves, it was observed that significantly different storage conditions had an influence on the resulting ageing curves. Finally, interpretation models, such as thresholds and trend tests, were evaluated and discussed in view of the obtained results. Trend tests were considered more suitable than threshold models. As both approaches showed limitations, an alternative model, based on the slopes of the ageing curves, was also proposed.
Resumo:
Low-molecular-weight heparins have become the predominant choice for deep venous thrombosis prophylaxis and treatment. However, their use may cause bleeding complications. Intrahepatic bleeding is exceptional and only very few cases have been described. The authors present a unique case of fatal intrahepatic hematoma complicating nadroparin use in a 65-year-old woman with a hepatic cyst who was admitted to hospital for unilateral total hip arthroplasty. At autopsy, hemoperitoneum (2,000 ml of blood and clots) was evident. A ruptured sub-capsular hematoma involving the right lobe of the liver was observed. The hemorrhage within the cyst induced by the nadroparin use was likely responsible for the subsequent hepatic hematoma, liver rupture, and death. This case highlights the need for pathologists and surgeons to be aware of the possibility of intrahepatic hematoma in patients who have received low-molecular-weight heparins, undergone major surgery and present postoperative hemodynamic instability, especially in those with preoperative diagnosis of hepatic cyst.
Resumo:
The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.
Resumo:
Well developed experimental procedures currently exist for retrieving and analyzing particle evidence from hands of individuals suspected of being associated with the discharge of a firearm. Although analytical approaches (e.g. automated Scanning Electron Microscopy with Energy Dispersive X-ray (SEM-EDS) microanalysis) allow the determination of the presence of elements typically found in gunshot residue (GSR) particles, such analyses provide no information about a given particle's actual source. Possible origins for which scientists may need to account for are a primary exposure to the discharge of a firearm or a secondary transfer due to a contaminated environment. In order to approach such sources of uncertainty in the context of evidential assessment, this paper studies the construction and practical implementation of graphical probability models (i.e. Bayesian networks). These can assist forensic scientists in making the issue tractable within a probabilistic perspective. The proposed models focus on likelihood ratio calculations at various levels of detail as well as case pre-assessment.
Resumo:
A recent publication in this journal [Neumann et al., Forensic Sci. Int. 212 (2011) 32-46] presented the results of a field study that revealed the data provided by the fingermarks not processed in a forensic science laboratory. In their study, the authors were interested in the usefulness of this additional data in order to determine whether such fingermarks would have been worth submitting to the fingermark processing workflow. Taking these ideas as a starting point, this communication here places the fingermark in its context of a case brought before a court, and examines the question of processing or not processing a fingermark from a decision-theoretic point of view. The decision-theoretic framework presented provides an answer to this question in the form of a quantified expression of the expected value of information (EVOI) associated with the processed fingermark, which can then be compared with the cost of processing the mark.
Resumo:
An analysis of latent fingermark residues by Sodium-Dodecyl-Sulfate PolyAcrylamide Gel Electrophoresis (SDS-PAGE) followed by silver staining allowed the detection of different proteins, from which two major bands, corresponding to proteins of 56 and 64 kDa molecular weight, could be identified. Two other bands, corresponding to proteins of 52 and 48 kDa were also visualizable along with some other weaker bands of lower molecular weights. In order to identify these proteins, three antibodies directed against human proteins were tested on western blots of fingermarks residues: anti-keratin 1 and 10 (K1/10), anti-cathepsin-D (Cat.D) and anti-dermcidin (Derm.). The corresponding antigens are known to be present in the stratum corneum of desquamating stratified epithelium (K1/10, Cat.D) and/or in eccrine sweat (Cat.D, Derm.). The two major bands were identified as consistent with keratin 1 and 10. The pro-form and the active form of the cathepsin-D have also been identified from two other bands. Dermcidin could not be detected in the western blot. In addition, these antibodies have been tested on latent fingermarks left on polyvinylidene fluoride (PVDF) membrane, as well as on whitened and non-whitened paper. The detection of fingermarks was successful with all three antibodies.
Resumo:
Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
A case of sustained combustion of a human body that occurred in 2006 in Geneva, Switzerland, is presented. The body of a man was discovered at home and found to have been almost completely incinerated between the knees and the mid-chest, with less damage to the head, arms, lower legs and feet. His dog was also found dead just behind the house door. The external source of ignition was most likely a cigarette or a cigar. The chair in which the man had been sitting was largely consumed while other objects in the room exhibited only a brown oily or greasy coating and were virtually undamaged. Toxicological analyses carried out on the blood from the lower legs showed low levels of desalkylflurazepam. Alcohol concentration was 1.10 per thousand, carboxyhaemoglobin levels were 12% and cyanide concentration was 0.05 mg/L. Toxicological analyses carried out on the dog's blood showed carboxyhaemoglobin levels at 65%.